Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Prijanto, Teguh Budi" wg kryterium: Wszystkie pola


Wyświetlanie 1-2 z 2
Tytuł:
Study of Liquid Waste Quality and Potential Pollution Load of Motor Vehicle Wash Business in Bekasi City (Indonesia)
Autorzy:
Fikri, Elanda
Putri, Arifah Nur Shabrina
Prijanto, Teguh Budi
Syarief, Osman
Powiązania:
https://bibliotekanauki.pl/articles/123217.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
liquid waste quality
pollution load
motor vehicle wash business
Opis:
The increasing number of motor vehicles in Bekasi city each year has led to the development of the motor vehicle wash business that can cause water pollution due to the resulting liquid waste. The use of various chemicals in these activities is one factor that affects the quality of liquid waste. This study aims to identify the quality of the liquid waste from motor vehicles wash in Bekasi city. The sample in this study was the liquid waste from the semi-automatic motor vehicles wash business in the North Bekasi region. The result of the research conducted in 3 locations showed that the processing of liquid waste produced was not carried out before being discharged into the environment. The results of test parameter presented in location 1, location 2, and location 3, respectively, were pH around 6.0, 5.0, and 4.8. TSS was 279.7 mg/l, 259.4 mg/l, 333.6 mg/l, COD was 657.1 mg/l, 182.1, 460.0 mg/l, oil and fat were 79.1 mg/l, 46.2 mg/l, 86.7 mg/l, phenol was 2.7 mg/l, 1.5 mg/l, 3.2 mg/l, and the highest potential pollution load was in COD parameter and TSS. Therefore, it is recommended that a motor vehicle wash business begins to pay attention to the impact of liquid waste by processing it before discharging into the environment and the Bekasi City government should begin to control water pollution, especially in those businesses.
Źródło:
Journal of Ecological Engineering; 2020, 21, 3; 128-134
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Phenomenon of Medical Waste Recycling in Indonesia: Contact Time and Chlorine Dose as a Disinfectant with the Bio-Indicator Bacillus subtilis and Bacillus stearothermophilus
Autorzy:
Fikri, Elanda
Kurniati, Iis
Wartiniyati, -
Prijanto, Teguh Budi
Pujiono, -
Syarief, Osman
Khair, Amar Sharaf Eldin
Powiązania:
https://bibliotekanauki.pl/articles/1839585.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
recycling
medical waste
dosage
duration of contact
chlorine
disinfection
Opis:
Efforts that have been done to manage the Hazardous and Toxic waste into non-Hazardous and Toxic waste are done by emptying, shredding, washing, and rinsing at least 3 times and disinfecting using chlorine. This is in accordance with the Indonesian Regulation of Ministry of Health No. 27 of 2017, which has stated that surface cleaning is permitted to use 0.05% chlorine during the process. Furthermore, in the Indonesian Regulation of the Ministry of Environment and Forestry No.56 of 2015, the chemical disinfection process is permitted to use an additional 3–6% sodium hypochlorite (NaOCl). However, there are still differences in dosage and it has not been mentioned regarding the immersion period during the disinfection process on both of the regulations. The purpose of this study was to determine the difference in contact time and the dose of chlorine as a disinfectant on the number of Bacillus subtilis and Bacillus stearothermophilus in the medical waste recycling process. The research design used in this study was a Randomized Factorial Design with experimental research type. A total of 104 recyclable medical waste samples were taken, using 3 treatments and 6 repetitions. The average temperature of the chlorine solution at the contact time of 15 minutes, 30 minutes, and 45 minutes was 24.34 °C; 24,53 °C; and 24,54 °C respectively, while the average pH of the chlorine solution at the contact time of 15 minutes, 30 minutes, and 45 minutes was 8.344; 8,375; and 8,461 respectively. The results showed that there was no difference in the duration of contact and the dose of chlorine as a disinfectant in the medical waste recycling process with a p-value of 0.377. The percentage reduction in the number of Bacillus subtilis and Bacillus stearothermophilus before and after treatment was 99.99% based on 4 positive controls. The findings in this study were the duration of contact time and the effective dose used in the recycling process of medical waste, which was at a dosage of 0.03% with 45 minutes of contact time. The government needs to conduct a re-assessment regarding the recommended ideal dosage in the surface disinfection process so that it would not cause a potential risk to humans or the environment.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 47-58
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies