Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Piątkowski, J. S" wg kryterium: Wszystkie pola


Wyświetlanie 1-6 z 6
Tytuł:
Timed models of security protocols including delays in the network
Autorzy:
Szymoniak, S.
Kurkowski, M.
Piątkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/122609.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
computer science
mathematical models
informatyka
modele matematyczne
Opis:
A very important part of the network and computer systems is to ensure an appropriate level of information transmission security. Security is based primarily on properly selected communication in security protocol. Unfortunately, the time-dependent protocols are vulnerable to attacks; therefore there is a need to verify these protocols. For verification purposes, protocols can be modeled using timed automata. During the modeling and verification of the protocols, one should also keep in mind delays in the network. So far, delays in the network were not modeled.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2015, 14, 3; 127-139
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroskopia konfokalna SIL
Autorzy:
Krajnik, B.
Piątkowski, D.
Maćkowski, S.
Gagoś, M.
Tomaszewska, E.
Grobelny, J.
Powiązania:
https://bibliotekanauki.pl/articles/274059.pdf
Data publikacji:
2011
Wydawca:
Roble
Tematy:
mikroskopia konfokalna
SIL
szklana soczewka imersyjna
kompleks PCP
confocal microscopy
solid immersion lens
PCP complex
Opis:
Przedstawiamy układ mikroskopu konfokalnego wyposażonego w szklaną soczewkę imersyjną do wysokorozdzielczych pomiarów spektroskopowych. Zaprezentujemy rezultat wykorzystania mikroskopu do pomiarów map fluorescencji pojedynczej monowarstwy Langmuira-Blodgetta zawierającej kompleksy fotosyntetyczne oraz nanocząstki srebra. Obecność nanocząstek srebra istotnie wpływa na wydajność fluorescencji chromoforów w badanych warstwach.
Źródło:
LAB Laboratoria, Aparatura, Badania; 2011, 16, 6; 6-8
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fluorescence Microscopy of Corrole-Single Silver Nanowire Hybrid Nanostructures
Autorzy:
Czechowski, N.
Olejnik, M.
Nowak-Król, A.
Piątkowski, D.
Heiss, W.
Gryko, D.
Mackowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/1419537.pdf
Data publikacji:
2012-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
33.50.-j
78.67.Uh
73.20.Mf
81.07.Pr
81.07.-b
Opis:
We report on confocal microscopy imaging of hybrid nanostructures composed of silver nanowires and corroles. Both nanomaterials were separated by a 30 nm thick $SiO_2$ spacer in order to inhibit fluorescence quenching. The results show that for such a hybrid nanostructure the average enhancement of the fluorescence intensity reached 2.5. Importantly, the coupling to plasmon excitations in metallic nanowires leaves no effect on the fluorescence spectrum of the organic molecules.
Źródło:
Acta Physica Polonica A; 2012, 122, 2; 333-336
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Plasmon Resonance in Silver Island Film on the Optical Properties of Peridinin-Chlorophyll-Protein Light-Harvesting Complexes
Autorzy:
Ciszak, K.
Olejnik, M.
Strzelecki, J.
Krajnik, B.
Piątkowski, D.
Hofmann, E.
Mackowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/1419506.pdf
Data publikacji:
2012-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
33.50.Dq
73.20.Mf
87.15.M-
81.07.Pr
Opis:
We study the effect of plasmon excitations in silver island film on the optical properties of peridinin-chlorophyll-protein light-harvesting complex using scanning fluorescence microscopy. With this technique we can unambiguously locate areas where the biomolecules are deposited on the metallic nanostructures from the areas where they stick to the glass surface. The enhancement factor of fluorescence intensity obtained for such a hybrid nanostructure is found to be 3. Plasmon excitations in the SIF layer also influence the dynamics of the emission, but in this case the interpretation of the results is more complex.
Źródło:
Acta Physica Polonica A; 2012, 122, 2; 275-278
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of X-S Control Cards to Parameter Control in the Machining Process of Piston Castings for Internal Combustion Engines
Autorzy:
Krępa, Adam
Piątkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/2126905.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
control cards
casting quality
machining of castings
SPC
Statistical Process Control
karty kontrolne
jakość odlewów
obróbka odlewów
statystyczna kontrola procesu
Opis:
This article discusses the possibility of using a two-track X-S control card on a Mesas device to control the production process parameters of piston castings for combustion engines. The research was carried out at the Federal-Mogul Gorzyce company. The basis for estimating the variability of the process results from the mean value (X) is the standard deviation (S). Thanks to specially designed measuring stations that use algorithms to calculate process indicators (Cp and/or Cpk) and their visualization, the cost of manufacturing products and the number of non-compliant products (scraps) are reduced. The process stability was investigated by measuring the key dimensions of the piston casting in a specific population and a given measurement cycle. Taking into account the precision of details, their technical condition, and surface quality, the production machines and cutting tools were optimally selected. It has been found that an important element of the effective use of Statistical Process Control (SPC) are trained/experienced operators who can correctly interpret the resulting control chart forms.
Źródło:
Archives of Foundry Engineering; 2021, 21, 4; 116--120
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena toksyczności mieszanin gazowych z okolic szybu sg-2 KGHM Polska Miedź S.A. w aspekcie uciążliwości zapachowej dla lokalnej społeczności
Evaluation of toxicity of gaseous mixtures emitted by KGHM POLSKA MIEDŹ S.A. SG-2 exhaust shaft in the aspect of odour problem for local community
Autorzy:
Bachowski, C.
Janicka, A.
Piątkowski, J.
Skrętowicz, M.
Zawiślak, M.
Powiązania:
https://bibliotekanauki.pl/articles/167485.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
problemy odorowe w górnictwie
toksyczność mieszanin gazowych
rozprzestrzenianie zanieczyszczeń
siarkowodór
lotne związki organiczne (LZO)
odour problems in mining industry
gaseous mixtures toxicity
pollution distribution
sewer gases
volatile organic compounds (VOCs)
Opis:
Zgłaszany przez mieszkańców gminy Jerzmanowa problem uciążliwości zapachowej w okolicach szybu SG-2 budzi zaniepokojenie zgłaszających, nie tylko w aspekcie wpływu emitowanych gazów na jakość środowiska, ale przede wszystkim w zakresie potencjalnie niekorzystnego wpływu na zdrowie. W artykule przedstawiono wyniki pracy badawczej realizowanej przez Politechnikę Wrocławską na zlecenie KGHM, której celem było wykonanie oceny toksyczności mieszanin gazowych z okolicy szybu SG2 w korelacji z określeniem stężenia zapachowego, subiektywnymi odczuciami mieszkańców gminy Jerzmanowa oraz badaniami modelowymi. Na podstawie przeprowadzonej pracy stwierdzono, że stopień toksyczności gazów emitowanych z szybu SG2 (w testach in vitro, metodą BAT-CELL®) określa się od słabego i umiarkowanego (w przypadku referencyjnej linii komórkowej nabłonka płuc ludzkich A549) po średni (w przypadku referencyjnej linii komórkowej tkanki podskórnej myszy L929), co może wskazywać na większe powinowactwo gazów w stosunku do negatywnego wpływu na skórę niż na drogi oddechowe) oraz, że emitowane gazy z szybu SG2 nie wykazują charakteru toksycznego w imisji, w przypadku obu linii komórkowych, w badanych punktach zidentyfikowanych jako najbardziej narażone na działanie gazów pochodzących z emitora.
The reported odour problem in Jerzmanowa district, where SG-2 exhaust shaft is located, concerns local citizens especially in the health aspect. The paper presents the results of the researches, provided by Wroclaw University of Technology for KGHM POLSKA MIEDŹ S.A., which are aimed at the evaluatation the gaseous mixture toxicity in emission (SG-2 shaft) and immision (Jerzmanowa district area) in correlation with the measured odours intensity, subjective feelings of local citizens and emitted substances distribution. The researches results indicate that toxicity level of gaseous mixtures emitted directly from the SG-2 shaft (based on In vitro tests delivered thanks to innovative BAT-CELL® method) ranges from low (A549 – standard human lung cells line) to medium (L929 – standard mouse skin cells line). What is important – the mixture of gases in immision (area of Jerzmanowa district) is not toxic in any tested location, despite the fact that citizens feelings indicato that the odour problem exists.
Źródło:
Przegląd Górniczy; 2017, 73, 1; 13-19
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies