Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Photovoltaic Systems" wg kryterium: Wszystkie pola


Tytuł:
Multi-objective optimal allocation and sizing of hybrid photovoltaic distributed generators and distribution static var compensators in radial distribution systems using various optimization algorithms
Autorzy:
Zellagui, Mohamed
Belbachir, Nasreddine
El-Bayeh, Claude Ziad
Bekkouche, Benaissa
Powiązania:
https://bibliotekanauki.pl/articles/41185993.pdf
Data publikacji:
2023
Wydawca:
Politechnika Warszawska, Instytut Techniki Cieplnej
Tematy:
renewable sources
radial distribution system
photovoltaic distributed enerators
distribution static var compensator
źródła odnawialne
systemy dystrybucji promieniowej
generator fotowoltaiczny
Opis:
In the recent years, a considerable growth was about the integration of renewable sources in the Radial Distribution Systems (RDS), as Photovoltaic Distributed Generators (PVDG) due to their importance in achieving plenty desired technical and economic benefits. Implementation of the Distribution Static Var Compensator (DSVC) in addition to the PVDG would be one of the best choices that may provide the maximum of those benefits. Hence, it is crucial to determine the optimal allocation of the devices (PVDG and DSVC) into RDS to get satisfactory results and solutions. This paper is devoted to solving the allocation problem (location and sizing) of hybrid PVDG and DSVC units into the standards test systems IEEE 33-bus and 69-bus RDSs. Solving the formulated problem of the optimal integration of hybrid PVDG and DSVC units are based on minimizing the proposed Multi-Objective Functions (MOF) which is represented as the sum of the technical-economic parameters of Total Active Power Loss (TAPL), Total Reactive Power Loss (TRPL), Total Voltage Deviation (TVD), Total Operation Time (TOT) of the overcurrent relays (OCRs) installed in the RDS, the Investment Cost of PVDGs (ICPVDG) and the Investment Cost of DSVC (ICDSVC)), by applying various recent metaheuristic optimization algorithms. The simulation results reveal the superiority and the effectiveness of the Slime Mould Algorithm (SMA) in providing the minimum of MOF, including minimization of the powers losses until 16.209 kW and 12.110 kVar for the first RDS, 4.756 kW and 7.003 kVar for the second RDS, enhancing the voltage profiles and the overcurrent protection system. Based on the paper’s results it is recommended to optimally integrate both PVDG and DSVC units into practical distribution networks.
Źródło:
Journal of Power Technologies; 2023, 103, 2; 89-103
1425-1353
Pojawia się w:
Journal of Power Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Systemy fotowoltaiczne w budynkach – model pracy w warunkach klimatycznych Lublina a aspekty środowiskowe
Photovoltaic systems in buildings – model of work in Lublin climate conditions and environmental aspects
Autorzy:
Żelazna, A.
Powiązania:
https://bibliotekanauki.pl/articles/408400.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
ślad węglowy
energia słoneczna
konwersja fotowoltaiczna
ocena cyklu życia
zarządzanie środowiskowe
wskaźnik Global Warming Potential
carbon footprint
solar energy
photovoltaic
life cycle assessment (LCA)
environmental management
Global Warming Potential
Opis:
Z uwagi na rosnącą konsumpcję oraz wyczerpywanie złóż kopalin jednym z istotnych problemów jest zaopatrzenie w energię. W związku z tym odnawialne źródła energii, takie jak energia słoneczna, stają się coraz bardziej popularne, jednak wprowadzaniu na rynek nowych technologii powinna zawsze towarzyszyć analiza ich oddziaływania na środowisko. W niniejszym artykule przedstawiono wyniki porównania emisji ditlenku węgla na bazie metodologii zarządzania środowiskowego Life Cycle Assessment (Ocena Cyklu Życia) wybranych systemów fotowoltaicznych. Symulacja pracy instalacji obejmowała uwzględnienie lokalnych warunków klimatycznych. W porównaniu ze wskaźnikami emisji dla konwencjonalnych źródeł energii, wymienione technologie wykazują znaczny spadek wskaźników emisji gazów cieplarnianych w perspektywie cyklu życia i dlatego też mogą być stosowane w celu realizacji uregulowań międzynarodowych w tym zakresie.
Due to the increasing consumption and depletion of fossil fuels’ resources, one of the nowadays major problems is energy supply. Consequently, renewable energy sources, such as solar energy, are becoming more and more popular. However, introduction of new technologies should always be accompanied by the analysis of their impact on the environment. This article presents the results of the comparison of carbon dioxide emissions from selected photovoltaic systems on the basis of the environmental management method Life Cycle Assessment. Model of the installation work included local climate conditions. In comparison with the emission indicators of conventional energy sources, solar technologies bring a significant decrease of greenhouse gas emissions throughout the life cycle, and therefore can be used for the implementation of the international regulations in this area.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2015, 2; 64-71
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Selected Factors on PV Systems Environmental Indicators
Wpływ wybranych czynników na wskaźniki oddziaływania na środowisko instalacji fotowoltaicznych
Autorzy:
Żelazna, A.
Zdyb, A.
Pawłowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1817988.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
photovoltaic systems
environmental indicators
life cycle assessment (LCA)
ecoindicator
GHG
instalacje fotowoltaiczne
wskaźniki środowiskowe
Ocena Cyklu Życia
ekowskaźnik
gazy cieplarniane
Opis:
Rosnąca świadomość zagrożeń dla środowiska naturalnego i klimatu powodowanych przez działalność człowieka stała się motorem zmian w sposobie eksploatacji zasobów naturalnych. Wiele porozumień międzynarodowych, począwszy od Deklaracji podsumowującej konferencję Narodów Zjednoczonych z 1972 roku, a skończywszy na Porozumieniu Paryskim (2015) zostało podpisanych w celu minimalizacji negatywnego oddziaływania na środowisko, związanego w szczególności z energetyką. Jednym z podstawowych celów stawianych przed tą branżą jest spełnienie kryteriów rozwoju zrównoważonego. Instalacje fotowoltaiczne są jednym z odnawialnych źródeł energii, dotowanym z budżetu organizacji międzynarodowych oraz poszczególnych państw jako zmniejszające potencjalne oddziaływanie sektora energetycznego na środowisko. Jednakże produkcja, użytkowanie i zagospodarowanie końcowe modułów fotowoltaicznych nie są obojętne dla środowiska, istnieje więc konieczność porównania pozytywnych i negatywnych efektów powodowanych przez wymienione procesy. Bilans środowiskowy tego rodzaju instalacji może zostać oceniony za pomocą Oceny Cyklu Życia (Life Cycle Assessment). Celem pracy jest porównanie aspektów środowiskowych wybranych systemów fotowoltaicznych pracujących w różnych lokalizacjach.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 722-732
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Web data scraping for digital public relations analysis based on the example of companies installing photovoltaic systems
Autorzy:
Zdonek, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/27313485.pdf
Data publikacji:
2022
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
digital public relations
Polska
cities
photovoltaics
web scraping
cyfrowe public relations
Polska
miasta
fotowoltaika
Opis:
Purpose: The first objective of this article was an attempt at identifying the major differences between such terms as public relations (PR), digital public relations (DPR) and digital marketing (DM). The second objective was to employ selected web data scraping techniques to analyse DPR of service providers installing photovoltaic systems. Design/methodology/approach: The first objective of this article was achieved by analysing reference works. To achieve the second objective, the author used MS Excel, web scraping and proprietary computer scripts in R and Python. In this way, selected details were obtained from the companies catalogue at panoramafirm.pl and Google search engine, and then the received results were compared and analysed. What is more, the results from Google search engine were obtained and analysed for 964 towns and cities entered in the engine with the “photovoltaics” phrase. Findings: 50 thousand URLs were obtained and 1,755 unique website domain addresses were extracted. Analysing the content of websites at the obtained Internet domains, 6 major categories of websites were identified, which appeared in the first 10 search results for the photovoltaic-related queries. These are: Company Websites (CW), Blog Websites (BW), Announcement Services (AS), SEO Landing Pages (SLP), Public Announcement Pages (PAP) and Social Media Page (SMP). Each of these categories is characterised briefly and a few examples are provided for each of them. Research limitations/implications: The limitations of this article include the focus on one companies catalogue, i.e., panoramafirm.pl, and the results from Google search engine solely for the Polish language. Moreover, only the results of the first 10 links from Google engine for the single “photovoltaics” phrase and town/city name were taken into consideration. Originality/value: This article has a theoretical and practical value. The analysis allowed to identify six categories of websites, which may be analysed with respect to digital public relations in the area of photovoltaic system installation. The most important of them are the websites belonging to the Company Website (CW) and Social Media Page (SMP) types. This article is addressed to anyone interested in obtaining data from the Internet using web scraping technique and data analysis in the area of digital public relations (DPR).
Źródło:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska; 2022, 161; 365--380
1641-3466
Pojawia się w:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementacja algorytmu sterowania rozmytego do utrzymywania maksymalnego punktu pracy elektrowni fotowoltaicznej
Implementation of fuzzy control algorithm for photovoltaic array maximum power point tracking
Autorzy:
Zawistowski, M.
Wójtowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/408372.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
sterowanie rozmyte
systemy fotowoltaiczne
śledzenie maksymalnego punktu pracy
fuzzy control
photovoltaic systems
maximum power point trackers
Opis:
Ze względu na swoje nieliniowe charakterystyki prądu I i napięcia U, elektrownia fotowoltaiczna powinna być wyposażona w algorytm śledzenia maksymalnego punktu wydajności. Pozwala to na uzyskiwanie maksymalnych wartości energii w szerokim spektrum zmieniających się warunków oświetlenia. Obecnie istnieje wiele algorytmów wyznaczania maksymalnego punktu pracy elektrowni fotowoltaicznej, celem artykułu jest przedstawienie metody wyznaczania trajektorii punktu maksymalnej wydajności elektrowni fotowoltaicznej za pomocą sterowania rozmytego.
Due to the non-linear characteristics of the current I and voltage U, a PV plant should be equipped with a maximum power point tracking algorithm. This allows obtaining the maximum amount of energy in a large range of illumination. Presently there are many algorithms for determining the maximum operating point of the photovoltaic power plant. This paper is aimed to present the determination of the maximum operating point of the photovoltaic power plant using fuzzy control.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2015, 1; 33-36
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytmy śledzenia punktu mocy maksymalnej (MPPT) w systemach fotowoltaicznych
Algorithms of maximum power point tracking (MPPT) in photovoltaic systems
Autorzy:
Zaremba, A.
Rodziewicz, T.
Wacławek, M.
Powiązania:
https://bibliotekanauki.pl/articles/126793.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
metody śledzenia
punkt mocy maksymalnej
systemy fotowoltaiczne
tracking algorithm
maximal power point
photovoltaic systems
Opis:
Przedstawiono przegląd podstawowych metod śledzenia punktu mocy maksymalnej w systemach fotowoltaicznych, tj.: metody pośrednie oraz bezpośrednie. Zagadnienie to jest bardzo ważne w nowoczesnych systemach fotowoltaicznych, ponieważ pozwala ono na zoptymalizowanie uzysku energii przy danych parametrach wejściowych (napromieniowanie, warunki pogodowe, temperatura itp.). Pokazano sposób działania poszczególnych algorytmów, a dla wybranych podano wzory opisujące ich działanie. Przeanalizowano słabe i silne strony wybranych metod oraz możliwości ich zastosowania w nowoczesnych systemach fotowoltaicznych.
Paper shows an overview of the basic algorithms of maximum power point tracking (MPPT) in the photovoltaic systems, ie the direct and indirect methods. This issue is very important in modern photovoltaic systems because it allows to optimize the energy yield for given input parameters (irradiation, weather conditions, temperature, etc.). Paper shows how the different algorithms work, and for selected models gives equations describing their results. Also examines the strengths and weaknesses of selected methods and their applicability in modern photovoltaic systems.
Źródło:
Proceedings of ECOpole; 2012, 6, 2; 805-810
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency analysis of 1 MW PV farm mounted on fixed and tracking systems
Autorzy:
Walichnowska, Patrycja
Mroziński, Adam
Idzikowski, Adam
Fröhlich, Siegmund Richard
Powiązania:
https://bibliotekanauki.pl/articles/31342637.pdf
Data publikacji:
2022
Wydawca:
Politechnika Częstochowska
Tematy:
farma fotowoltaiczna
efektywność
system śledzący słońce
photovoltaic farm
efficiency
solar-tracking system
Opis:
The article presents a comparison of results from a simulation of the energy production by a photovoltaic installation with a tracking system and a stationary PV farm in the PVSyst program. The analyzed 1 MW PV installations were located in the Kuyavian-Pomeranian Voivodeship in Poland. Energy production results obtained from the installation with a tracking system were compared with a stationary farm with panels placed at an angle of 20° and an azimuth 0°. The paper also presents the types of tracking systems and discusses the advantages of this solution and its risks compared to traditional panel mounting. The results obtained in the study indicated that the use of a tracking system increased the annual energy production compared to a stationary farm.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2022, 11; 75-83
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instalacje fotowoltaiczne jako nowe wyzwanie dla straży pożarnej. Część I: Budowa i zasada działania systemów fotowoltaicznych
Photovoltaic Installations as New Challenge for the Fire Service. Part I: Design and Operation of Photovoltaic Systems
Autorzy:
Urbańczyk, Mateusz
Hajdas, Damian
Barasiński, Adrian
Powiązania:
https://bibliotekanauki.pl/articles/1838222.pdf
Data publikacji:
2020
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
fotowoltaika
odnawialne źrodła energii
zarządzanie działaniami ratowniczo-gaśniczymi
ochrona przeciwpożarowa
photovoltaics
renewable energy sources
management of rescue and extinguishing systems
fire protection
Opis:
Instalacje fotowoltaiczne (PV) stały się integralną częścią instalacji elektroenergetycznej niskiego napięcia (nn) w gospodarstwach domowych i zakładach pracy. Coraz więcej osób decyduje się na korzystanie z alternatywnych systemów opartych na odnawialnych źródłach energii. Energia ta w zależności od sposobu pracy instalacji, oprócz bieżącego zapotrzebowania, może być gromadzona w akumulatorach bądź przesyłana do sieci elektroenergetycznej niskiego napięcia. Produkcja energii elektrycznej z wykorzystaniem modułów fotowoltaicznych jest przyjaznym rozwiązaniem dla właścicieli takich systemów, jak i środowiska, jednakże w przypadku wystąpienia sytuacji awaryjnej spowodowanej niewłaściwą pracą systemu może doprowadzić do powstania np. pożaru. Dlatego niezbędne jest kształcenie strażaków na temat zasad funkcjonowania takich systemów, mogących wystąpić zagrożeniach, sposobach ich dezaktywacji oraz wytycznych dotyczących postępowania podczas prowadzonych akcji. Celem pierwszej części artykułu jest przedstawienie ratownikom biorącym czynny udział w działaniach ratowniczo-gaśniczych budowy i zasady działania instalacji PV. Dobre zrozumienie zasad funkcjonowania umożliwi podejmowanie skuteczniejszych decyzji oraz zwiększy bezpieczeństwo strażaków.
Photovoltaic systems (PV) have become an integral part of low voltage (LV) powering lines used in households and work establishments. More and more people are interested in alternative systems based on renewable energy sources. Depending on the way the installation is meant to operate, apart from covering the current powering needs, this energy may also be accumulated in batteries or transmitted to the low voltage power grid. Generation of power with the use of photovoltaic modules is a friendly solution for owners of such systems and for the environment, yet in the event of an emergency situation caused by incorrect operation of the system it could among others cause a fire. This makes it necessary to assure training and education to firefighters so that they could become familiar with the functioning of such systems, potential hazards, methods to be adopted to deactivate them as well as guidelines for actions to be implemented during executed actions. The first section of the article presents rescuers actively involved in rescue and extinguishing actions with information concerning the design and principles of operation of the PV installation. Familiarisation with the functioning of the system would contribute to making better and more effective decisions, and is also expected to enhance the safety of firefighters.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2020, 4, 76; 7-27
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układy śledzące punkt maksymalnej mocy w inwerterach stosowanych w instalacjach fotowoltaicznych
Systems follow the maximum power point in inverters used in photovoltaic installations
Autorzy:
Trzmiel, G.
Powiązania:
https://bibliotekanauki.pl/articles/377415.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
instalacja fotowoltaiczna
PV
inwerter
MPP tracker
punkt maksymalnej mocy
Opis:
W pracy przedstawiono możliwości stosowania różnych algorytmów poszukiwania punktów maksymalnej mocy w instalacjach fotowoltaicznych (PV). Wspomniano o różnych sposobach zwiększania sprawności systemów PV i uzysków energii elektrycznej. Dokonano przeglądu stosowanych inwerterów (falowników) ze względu na kilka kryteriów. Przedstawiono również celowość stosowania oraz funkcjonalność układów śledzących punkt maksymalnej mocy, które wchodzą w skład inwerterów. Zwrócono uwagę na podstawowe zasady doboru różnych rodzajów inwerterów. Główną częścią pracy jest charakterystyka najczęściej stosowanych algorytmów pracy układów śledzących punkt maksymalnej mocy.
The paper presents the possibility of using different algorithms to search for the point of maximum power in installations of photovoltaic (PV). Mentioned about different ways to increase the efficiency of PV systems and electricity yields. Overview of the inverters due to several criteria was made. Also presented the desirability of the use and functionality of the systems tracking the maximum power point, which are included in the inverters. Attention was drawn to the basic principles for the selection of different types of inverters. The main part of the paper is the characteristic of the most commonly used circuits tracking the maximum power point algorithms.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 87; 23-35
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamics model of interleaved step-up DC-DC converter used in photovoltaic systems
Modelowanie dynamiki wielosekcyjnego podwyższającego przekształtnika DC-DC do zastosowań w systemach fotowoltaicznych
Autorzy:
Tomaszuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/152249.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
PV systems
step-up DC-DC converters
modeling
stability
controllability
systemy fotowoltaiczne
podwyższające przekształtniki DC-DC
modelowanie
stabilność
sterowalność
Opis:
Step-up DC-DC converters are the key parts of low voltage PV systems. Since parallel connected PV modules are connected directly to the converter, its driving algorithm should utilize maximum power point tracking (MPPT). Prior to implement such algorithms the dynamics of step-up DC-DC converter need to be investigated. On the example of an interleaved step-up DC-DC converter the paper presents a procedure to determine the converter stability, controllability and its dynamic characteristics.
Przekształtniki podwyższające DC-DC są kluczowymi elementami niskonapięciowych systemów fotowoltaicznych (PV), w których moduły fotowoltaiczne są ze sobą połączone równolegle tworząc panel. Ponieważ panel fotowoltaiczny znajduje się bezpośrednio na wejściu przekształtnika w jego sterowaniu powinien zostać użyty algorytm śledzący punkt maksymalnej mocy panela PV (MPPT). Zaimplementowanie takiego algorytmu jak też syntezę regulatora w zamkniętej pętli sprzężenia zwrotnego powinno poprzedzać zbadanie dynamicznych właściwości przekształtnika takich, jak: charakterystyki częstotliwościowe (Bodego), odpowiedź na skok jednostkowy oraz stabilność i sterowalność. Zasadniczym zadaniem jest opracowanie modelu przekształtnika czyli wyznaczenie równań stanu oraz na ich podstawie transmitancji. Niniejszy artykuł prezentuje na przykładzie wielosekcyjnego przekształtnika podwyższającego DC-DC procedurę sprawdzania stabilności i sterowalności przekształtnika oraz wyznaczania jego charakterystyk dynamicznych w celu weryfikacji projektu.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 2, 2; 83-86
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low voltage PV array model verification on computer aided test setup
Autorzy:
Tomaszuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/376132.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
PV module model
Photovoltaic Systems
Opis:
Low voltage photovoltaic (PV) array delivers electric power to the renewable energy systems which utilize step-up DC-DC converters. The performance of PV array is strictly dependent on environmental conditions such as solar radiation and ambient temperature. In this paper presented is MATLAB model of low voltage 3.2 kWp PV array composed of ten PV panels connected in parallel. The model itself is based on photodiode model and is supported by datasheet parameters of examined PV panels. Presented P-V curves show an influence of solar radiation and temperature on electric power produced by the array. The model simulation results were verified on computer aided laboratory test setup built upon LabVIEW environment. The test setup comprised PV array connected to 6 kW electronic DC load which was controlled by LabVIEW application. Since test conditions should be steady during test time each measurement of real PV array full P-V curve has to be done as quick as possible. This can be assured by computer aided measurement approach where time consumming tests can be easily automated and shortened. This paper presents PV array model, describes test setup and discusses laboratory test results.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 84; 183-189
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microcontroller based step-up DC-DC converter driver with MPPT algorithm implemenation
Autorzy:
Tomaszuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/376343.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
MPPT algorithms
photovoltaic systems
Opis:
Energy efficiency is one of most critical parameters in photovoltaic (PV) systems. Overall PV system efficiency improvement may be achieved by such means as topological changes, new generations of transistor switches and/or planar magnetic components use. But on the other hand whole system must follow the wheather changes such as solar energy delivery variation due to cloud shading as well as temperature fluctuations. In such conditions a driver should dynamically track maximum power point (MPPT) of a PV array. For the purposes of better understanding PV array performance the paper shows MatLab simulation of 3.2 kWp PV array. The driver discussed works with a range of different step up DC-DC converter topologies such as bridge based topologies as well as interleaved ones. The ASCII protocol which can be implemented in PC application is responsible for working parameters settings carrying and output data logging as well as current software status check. The paper presents practical implementation of the driver as a part of larger PV system where the interleaved DC-DC converter works with 3.2 kWp PV array of ten PV modules connected in parallel. Described MPPT algorithm takes advantage of modified Perturb and Observe (P&O) method. Presented are microcontroller hardware resources utilization, functional software architecture and developped MPPT algorithm which performance is shown on the plot.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 78; 233-240
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of high-efficiency interleaved step-up DC-DC boost-flyback converter to use in photovoltaic system
Autorzy:
Tomaszuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/378212.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
step-up DC-DC converters
high efficiency
photovoltaic systems
Opis:
In low-voltage photovoltaic (PV) systems high-efficiency high voltage gain step-up DC-DC converters are required as the interface between the PV panel and the load. Therefore overall performance of the PV system is essentially affected by the efficiency of step-up DC-DC converter itself. This paper presents the results of PSpice simulation of high-efficiency interleaved step-up DC-DC converter. The converter integrates boost and flyback topologies. Interleaved approach minimizes the current stress on the switches as well as allows reducing a sizes of the inductors but also decreases input current ripples. The other advantage of interleaving structure is flexibility of number of working phases extension. The number of working phases can be dynamically determined depending on the power requirements of the load. High efficiency assured by boost-flyback topology is achieved by the means of recycling the energy from input leakage inductance and relatively low voltage stress across the transistor switches which enables low drain-to-source resistance transistors application. The simulation carried out will present transient and performance characteristics of interleaved step-up DC-DC boost-flyback converter.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 79; 97-104
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of maximum power point tracking methods for photovoltaic systems
Autorzy:
Talha, A.
Boumaaraf, H.
Bouhali, O.
Powiązania:
https://bibliotekanauki.pl/articles/229456.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
maximum power point tracking (PPT)
PV
P&O
incremental conductance
fuzzy logic
converter
Opis:
The output characteristics of photovoltaic (PV) arrays are nonlinear and change with the solar irradiance and the cell's temperature. Therefore, a maximum power point tracking (MPPT) technique is needed to draw peak power from the solar array to maximize the produced energy. Among the hill climbing methods, the perturb and observe (P&O) method tracks the maximum power point (MPP) by repeatedly increasing or decreasing the output voltage at the MPP of the PV module. The implementation of the method is relatively simple, but it cannot track the MPP when the irradiance varies quickly with time. In addition, itmay cause system oscillation around the peak power points due to the effect of measurement noise. The incremental conductance (IncCond) method is also often used in PV systems. This method tracks the MPPs by comparing the incremental and instantaneous conductances of the solar array. This method requires longer conversion time, and a large amount of power loss results. In addition, extra hardware circuitry is required to implement the system. In this paper, it is shown that the negative effects associated with such a drawback can be greatly reduced if the intelligent method is used to improve P&O and IncCond algorithms. The perturbation step is continuously approximated by using fuzzy logic controller (FLC). By the digital simulation, the validity of the proposed control algorithm is proved.
Źródło:
Archives of Control Sciences; 2011, 21, 2; 151-165
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena techniczno-ekonomiczna systemów grzewczych w budynku o niemal zerowym zużyciu energii współpracujących z mikroinstalacją fotowoltaiczną
Technical and economic evaluation of heating systems in a nearly zero energy building cooperating with a photovoltaic microinstalation
Autorzy:
Szul, Tomasz
Kokoszka, Stanisław
Powiązania:
https://bibliotekanauki.pl/articles/946857.pdf
Data publikacji:
2020-06-30
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
zużycie energii końcowej w budynku
budynek o niemal zerowym zużyciu energii
pompy ciepła typu powietrze/woda
pa-nele grzewcze
mikroinstalacja PV
analiza ekonomiczna
koszty cyklu życia LCC
final energy consumption in a building
nearly zero energy building
air/water heat pumps
heating panels
PV microin-stallation
economic analysis
LCC life cycle costs
Opis:
Dla przykładowego budynku mieszkalnego jednorodzinnego obliczono zapotrzebowanie na moc i sezonowe zużycie energii do ogrzewania i przygotowania ciepłej wody użytkowej, określono również w oparciu o zestawienia statystyczne wielkość zużycia energii elektrycznej na cele bytowe (oświetlenie, AGD, RTV, itp.). Na tej podstawie dobrano moc i określono roczną wielkość produkcji przez mikroinstalację fotowoltaiczną pracującą w systemie ON-GIRD w ramach przepisów do-tyczących prosumentów zawartych w ustawie o OZE. Następnie przeprowadzono analizę ekonomiczną zgodnie z metodą opartą na kosztach cyklu życia LCC. Jako poziom odniesienia przyjęto budynek, w którym ogrzewanie i przygotowanie ciepłej wody użytkowej odbywa się za pomocą kotła gazowego kondensacyjnego, natomiast instalacja PV służy do pokrycia zapotrzebowania na energię elektryczną w budynku. Do analizy porównawczej przyjęto dwa systemy grzewcze, tj. pompę ciepła typu powietrze/woda oraz panele grzewcze. W tym przypadku instalacja PV miała pokryć wszystkie potrzeby energetyczne w budynku. W celu określenia zasadności montażu instalacji fotowoltaicznej służącej do pokrycia potrzeb energetycznych budynku dla poszczególnych wariantów, wykonano analizę ekonomiczną w oparciu o koszty cyklu życia LCC. Wyniki analizy wskazały, że lepszym wyborem dla inwestora będzie, jeżeli zdecyduje się na montaż systemu ogrzewania opartego na panelach grzewczych, m.in. ze względu na najkrótszy okres zwrotu nakładów inwestycyjnych.
For an exemplary single-family residential building, the power demand and seasonal energy consumption for heating and domestic hot water preparation were calculated, and the amount of electricity consumption for domestic purposes was also determined on the basis of statistical summaries. On this basis, the power was selected and the annual production volume of the photovoltaic microinstallation operating in the ON-GIRD system was determined under the Prospectus Reg-ulations of the Renewable Energy Sources Act. An economic analysis was then carried out based on methods based on LCC life cycle costs. A building where heating and domestic hot water preparation is carried out by means of a condens-ing gas boiler, while a photovoltaic installation serves to cover the electricity demand of the building was taken as a reference. Two heating systems were used for the comparison analysis, i.e. the air-water heat pump and the heating panels. In this case, the PV installation was to cover all energy needs in the building. In order to determine the validity of in-stalling a photovoltaic installation to cover the energy needs of the building for each variant, an economic analysis based on LCC life cycle costs was performed. The results of the analysis showed that a better choice for the investor will be if he decides to install a heating system based on heating panels, among others because of the shortest period of return on investment.
Źródło:
Technika Rolnicza Ogrodnicza Leśna; 2020, 1; 13-17
1732-1719
2719-4221
Pojawia się w:
Technika Rolnicza Ogrodnicza Leśna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies