Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "PV/T" wg kryterium: Wszystkie pola


Tytuł:
Cooling techniques for PV panels: A review
Autorzy:
Kozak-Jagieła, Ewa
Cisek, Piotr
Ocłoń, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/35126202.pdf
Data publikacji:
2023
Wydawca:
Radomskie Towarzystwo Naukowe
Tematy:
PV cooling methods
solar energy
photovoltaics cooling efficiency enhancement
performance
PV/T
metody chłodzenia paneli fotowoltaicznych
energia słoneczna
zwiększenie wydajności chłodzenia
wydajność
Opis:
Solar energy is considered one of the most dominant renewable energy sources. It can be used to produce electricity through PV panels. Unfortunatly, this technology is subject to limitations. High operating temperature exceeding 25°C, causes the PV panels to overheat, reducing their lifetime and efficiency. Various approaches to PV cooling are used to overcome these challenges.This paper presents a comprehensive overview of different cooling techniques to increase the performance of PV panels. Passive and active PV cooling systems are analysed using air, water, phase change materials (PCMs) and nanofluids as working agents. A review analysis showed that water cooling is better than air cooling. PCMs, which have recently been gaining in popularity, also deserve attention.
Źródło:
Scientiae Radices; 2023, 2, 1; 47-68
2956-4808
Pojawia się w:
Scientiae Radices
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Study of Temperature Influence on the Performance of PV/T Cell under Jordan Climate Conditions
Autorzy:
Al-Odat, Mohammed Qassim
Powiązania:
https://bibliotekanauki.pl/articles/2202185.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PV module
electrical conversion
electrical efficiency
water cooling
cooling
cell temperature
Opis:
The electrical performance and the productivity of PV module depend on two main parameters, i.e. the radiation intensity and the cell operating temperature. The module electrical efficiency and productivity are significantly reduced as its temperature increases. Accordingly, cooling of PV modules is one of the most effective techniques to obtain higher efficiency and productivity as well as to reduce the degradation modes of PV modules due to high temperatures. This research work presents an experimental study carried out to investigate the effect of PV module cooling on the performance of PV module under Irbid city (Jordan) climate conditions. It was found that the electrical efficiency and the productivity of the PV modules were approximately enhanced by 14%. Therefore, water cooling of the PV modules is essential to enhance their performance.
Źródło:
Journal of Ecological Engineering; 2022, 23, 10; 80--88
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solar Hot Water Heating and Electricity Generation Using PV/T Hybrid System
Autorzy:
Badran, Ali A.
Obeidat, Firas A.
Powiązania:
https://bibliotekanauki.pl/articles/2086426.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
solar energy system
water heating system
PV module
flat plate solar collector
Opis:
Experimental work has been carried out to study the possibility of combining a conventional solar water collector with a hybrid device, developed previously and known as PV/T system, in order to obtain hot water with temperature above 40 °C. The effect of the combination on the productivity of hot water and the produced electricity was found. The formerly developed device, in which there was a multi-purpose solar collector, can produce hot water and electricity. It was connected to the conventional fin-tube collector in series in order to raise the product temperature to a higher level. This development was achieved for the first time as a combination between a PV/T and a conventional fin-tube collector. Instrumentation to measure temperatures, solar radiation, wind speed and flow rate was installed on the system. It was found that the water temperature was raised from 29 °C to 32 °C in the PV/T collector system and, after flowing through the conventional collector, it was raised to 50 °C and above. It was also found that the power efficiency in the case of water flow is always higher than in the case of no water flow.
Źródło:
Journal of Ecological Engineering; 2022, 23, 5; 196--206
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical procedures and their practical application in PV module analyses. Part 3, Parameters of atmospheric transparency : determining and correlations
Autorzy:
Rodziewicz, T.
Rajfur, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818226.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
solar radiation spectrum
sky clearness index
diffused component content index
solar energy
photovoltaics
Opis:
The presented article examines aspects of a PV module testing using natural sunlight in outdoor conditions. The article discusses the physical sense of indexes: atmosphere purity, diffused component content, beam clear sky index. Procedures for their determination are given in relation to both instantaneous and daily values. Their close connection with the values of solar irradiance spectral distribution such as Average Photon Energy and Useful Fraction is demonstrated, as well as their usefulness in module testing in outdoor conditions. Their influence on the conversion of modules made from various absorbers and various technologies is demonstrated.
Źródło:
Opto-Electronics Review; 2020, 28, 1; 15--34
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photovoltaic systems - types of installations, materials, monitoring and modeling - review
Autorzy:
Andula, Angelika
Heim, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/105804.pdf
Data publikacji:
2020
Wydawca:
Centrum Badań i Innowacji Pro-Akademia
Tematy:
photovoltaic systems
BIPV
BAPV
PV/T
energy sources
modeling
systemy fotowoltaiczne
źródła energii
modelowanie
Opis:
Photovoltaic systems have become a common solution for, both small residential buildings as well as large service buildings. When buildings are being designed, it is important to focus on the aspect of the object's energy efficiency as lowering the energy consumption of a given facility is crucial. The article discusses the use of photovoltaic panels such as so-called BAPV (Building Applied Photovoltaics) and BIPV (Building Installed Photovoltaics) installations as well as photovoltaic thermal systems (PV/T), which generate both electricity and heat. The role of PV installation in so-called zero energy buildings and proposals for future research and solutions are also discussed.
Źródło:
Acta Innovations; 2020, 34; 40-49
2300-5599
Pojawia się w:
Acta Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of changes in the growth and chemical constituents of Anoectochilus formosanus Hayata grown under hydroponic conditions
Autorzy:
Nguyen, H.C.
Nhu, T.Q.M.
Dung, P.V.
Hieu, N.D.
Tuan, T.T.
Huyen, P.X.
Truong, D.-H.
Powiązania:
https://bibliotekanauki.pl/articles/80522.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Anoectochilus formosanus
medicinal plant
mineral nutrition
hydroponic cultivation
chemical constituent
antioxidant activity
phytochemical screening
alkaloid content
flavonoids
glycoside
terpenoid
steroid
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2018, 99, 4
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the potential yield and primary symptoms of Xanthomonas campestris pv. campestris infection in Asian vegetables grown in the Czech Republic
Ocena plonowania oraz symptomów infekcji bakteryjnej Xanthomonas campestris pv. campestris wybranych odmian azjatyckich warzyw z rodziny kapustowatych uprawianych w Republice Czeskiej
Autorzy:
Kopta, T.
Penazova, E.
Jurica, M.
Pokluda, R.
Powiązania:
https://bibliotekanauki.pl/articles/28483.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Botaniczne
Opis:
Selected cultivars of Asian brassicacean vegetables were evaluated for their yield potential and susceptibility to bacterial infection. Chinese broccoli, two cultivars of Chinese cabbage (‘Dwarf milk cabbage’ and improved ‘Tahtsai’), and mizuna were grown in the conditions of the Czech Republic. Morphological and yield parameters for the field conditions (plant height, plant diameter, and marketable weight) were verified. In addition, genotypes were tested for resistance to black rot [Xanthomonas campestris pv. campestris (Xcc)] at the planting stage. The results show that a very promising genotype of mizuna, which yielded best (1,478 g per plant). Chinese cabbage (cultivar ‘Dwarf milk cabbage’) also showed high yield values (2,839 g per plant), especially when compared to the reference value for Napa cabbage. Chinese Cabbage 1 (‘Dwarf milk cabbage’) and mizuna also showed a low susceptibility to infection by bacterial black rot at the planting stage. Both cultivars reached Level 2 (median) of infection, which corresponds to the extent of the symptoms on 25% of the leaf surface.
W doświadczeniu oceniano pod względem plonowania oraz podatności na infekcję bakteryjną wybrane odmiany azjatyckich warzyw z rodziny kapustowatych. Materiał badawczy stanowiły brokuł chiński, kapusta chińska w typie Tahtsai (odmiany ‘Dwarf milk cabbage’ i ulepszona ‘Tahtsai’) oraz kapusta chińska mizuna. W stadium rozsady analizowano również podatność wymienionych warzyw na Xanthomonas campestris pv. Campestris (Xcc). Najwyższy plon uzyskano w przypadku kapusty chińskiej mizuna (1478 g z rośliny). Kapusta chińska ‘Dwarf milk cabbage’ również wydała wysoki plon (2839 g z rośliny), szczególnie w porównaniu do powszechnie uprawianej kapusty pekińskiej. Odmiany kapusty chińskiej ‘Dwarf milk cabbage’ i mizuna wykazały w stadium rozsady niską podatność na infekcję bakteryjną wywołaną przez Xanthomonas campestris pv. Campestris (Xcc). Dla wymienionych odmian odnotowano 2-gi (mediana) poziom infekcji, który odpowiada wystąpieniu symptomów chorobowych na 25% powierzchni liści.
Źródło:
Acta Agrobotanica; 2018, 71, 4
0065-0951
2300-357X
Pojawia się w:
Acta Agrobotanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergetic Analysis of Hybrid Photovoltaic - Thermal Solar Collectors Coupled to Organic Rankine Cycles
Analiza ekologiczna hybrydowego układu fotowoltaika - kolektory słoneczne związanych organicznym cyklem Rankine’a
Autorzy:
Pinto, C.
Mady, C. E.
Powiązania:
https://bibliotekanauki.pl/articles/395979.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
exergy analysis
Organic Rankine Cycle
photovoltaic
thermal collector PV
solar thermal
analiza egzergii
cykl Rankine’a
fotowoltaika
kolektor PV/T
energia słoneczna
Opis:
In this work, the application of hybrid solar modules that combine photovoltaic panels and solar thermal collectors coupled with a low-temperature thermal cycle such as the Organic Rankine Cycle is discussed, their main purpose being an increase in the total electric power production per available area. This work will study the thermal and electrical power production efficiency of the hybrid system, the increase in the PV module electric conversion efficiency due to their cooling through heat transfer to the thermal cycle and the total exergetic efficiency of the system. A simplified simulation of the system in steady state conditions based on a thermal efficiency model will be performed with the aid of the EES (Engineering Equation Solver) software using climate data from Campinas, São Paulo, Brazil. The study shows that while the PV/T+ORC system does fulfill the purpose of increasing the electrical power generation both from the generator coupled to the thermal cycle and from the increase in the PV module efficiency due to its cooling. Thus, there is an increase the overall exergy efficiency of the system compared to uncoupled PV/T collectors.
W pracy omówiono zastosowanie hybrydowych modułów słonecznych łączących panele fotowoltaiczne z kolektorami słonecznymi w połączeniu z niskotemperaturowym cyklem termicznym, takim jak cykl organiczny Rankine'a, którego głównym celem jest zwiększenie całkowitej produkcji energii elektrycznej. W pracy zbadano wydajność produkcji energii cieplnej i elektrycznej w systemie hybrydowym, wzrost sprawności konwersji energii modułu fotowoltaicznego ze względu na ich chłodzenie poprzez przeniesienie ciepła do cyklu termicznego i całkowitą efektywność energetyczną układu. Uproszczona symulacja systemu w warunkach stanu ustalonego w oparciu o model sprawności cieplnej została przeprowadzona za pomocą oprogramowania EES (Engineering Equation Solver) wykorzystującego dane klimatyczne z Campinas, São Paulo, Brazylia. Badania wykazały, że system PV/T + ORC spełnia cel zwiększenia wytwarzania energii elektrycznej zarówno z generatora połączonego z cyklem termicznym, jak i ze wzrostu sprawności modułu PV ze względu na jego chłodzenie. W ten sposób zwiększa się ogólna efektywność egzergii systemu w porównaniu z niezwiązanymi kolektorami PV/T.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(4); 1-12
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parameters estimation and life cycle economic analysis of a PV powered tri-cycle in India
Autorzy:
Das, S.
Sadhu, P. K.
Majhi, A.
Ghatak, U.
Bandyopadhya, T.
Powiązania:
https://bibliotekanauki.pl/articles/141519.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PV
tri-cycle
LCEA
fuel-based
Opis:
This paper is devoted towards life cycle economic analysis (LCEA) of a solar photovoltaic (PV) powered tri-cycle. The paper is meant to propose a more systematic approach in determining the optimum use of scarce resources in order to determine the most cost-effective option of the solar tri-cycle. This analysis is based on the life cycle cost of this solar vehicle, involving its comparison with the customary fuel-based tri-cycle which exhibits the relatively less expenditure of the solar alternative. The economic analysis takes into account the fact that over 20 years, the overall price of solar component, replacement and electricity charges, is much lower as compared to that of a fuel-based tri-cycle in India taking into consideration the fuel cost, maintenance and annual inflation over the same period.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 655--665
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
PV/T Systems for Renewable Energy Storage: A Review
Autorzy:
Avijit, Mallik
Hasan, Md. Zahid
Powiązania:
https://bibliotekanauki.pl/articles/1177985.pdf
Data publikacji:
2018
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
HVAC
PV/T System
Solar Heat Radiation
Solar Power
Thermal Energy System
Opis:
Sunlight is converted into electricity and heat simultaneously with the help of PV thermal panels. It is examined that the efficiency of the PV/T panel is higher than the separate PV panels and solar thermal collectors’ efficiency. The electricity conversion-efficiency for a PV system is about 6% to 15% and in moreover cases 85% of the incoming solar energy is either reflected or absorbed as heat energy. Now a day’s Renewable energy has become a hot topic. The energy researchers day by day making advanced researches to make this type of system a useable one. Non-renewable sources will be approximately finished within next 100-150 years. So this type of energy is very important for everyone. Normally researches are made on producing electricity from renewable sources like sun-light, wind energy, tidal energy and etc. In this paper there is a compact review of solar photovoltaic thermal system. The performance of the solar cell decreases with the increasing of temperature. Both the electrical efficiency and the power output of PV module depend on the operating temperature. Photovoltaic thermal hybrid solar collectors, also known as hybrid PV/T systems are systems in which sunlight is converted into thermal and electrical energy both. This paper contains a combination of basic and advanced hybrid PV/T systems that are usable in Asian region.
Źródło:
World Scientific News; 2018, 96; 83-95
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Roczna wydajność instalacji PV zamontowanej na dachu budynku dydaktycznego Uniwersytetu Opolskiego
Annual efficiency of a PV installation mounted on the roof of the University of Opole didactic building
Autorzy:
Świsłowski, P.
Dębska, L.
Rajfur, M.
Rodziewicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/126628.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
alternatywne źródła energii
fotowoltaika
PV
moduł fotowoltaiczny
uzysk energetyczny
ekologia
renewable energy sources
photovoltaics
photovoltaic module
energy yield
ecology
Opis:
Celem badań była analiza i ocena sprawności pracy instalacji fotowoltaicznej zamontowanej na dachu budynku dydaktycznego Uniwersytetu Opolskiego mieszczącego się przy ul. Kominka 6 w Opolu. Zakres pracy obejmował ocenę: energetyczną - uzysku energetycznego (ilość wyprodukowanego prądu a położenie geograficzne paneli fotowoltaicznych) i ekologiczną - redukcja emisji szkodliwych substancji niewyemitowanych do aerozolu atmosferycznego z powodu produkcji prądu przez instalację PV, a niedostarczonej przez elektrownię opalaną węglem. Badania wykazały dobry wynik uzysku energetycznego w ciągu roku - 5,30 MWh energii z tego systemu oraz znaczną redukcję emisji CO2 do atmosfery - 4,27 Mg/rok, co potwierdza ekologiczny charakter instalacji fotowoltaicznych.
The objective of the carried out study was to analysis of operation and effectiveness assessment of the photovoltaic system installed on the roof of the University of Opole building located at Kominka 6 street in Opole. The scope of the study included an assessment of: power generation - energy yield (quantity of generated electricity and geographical location of photovoltaic panels) and ecological - reduction of emission of harmful substances not emitted to the atmospheric aerosol for the production of electricity by the PV installation and not provided by the coal-fired power plant. The studies showed good result of energy production during the year 5.30 MWh energy from this system, and significant reduction of CO2 emission to atmosphere 4.27 Mg/year which indicates the ecological motivation of projects fort the installation of renewable energy sources.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 253-263
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacja pracy hybrydowego układu zasilania typu solarno–wiatrowego z elektrochemicznym magazynem energii
Simulation of a solar–wind hybrid power system with energy storage
Autorzy:
Głuchy, D.
Jarmuda, T.
Tomczewski, A.
Powiązania:
https://bibliotekanauki.pl/articles/377559.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
system hybrydowy
moduł PV
turbina wiatrowa
elektrochemiczny magazyn energii
środowisko MATLAB & SIMULINK
Opis:
W pracy przedstawiono model hybrydowego układu zasilania typu solarno–wiatrowego z elektrochemicznym magazynem energii opracowany z zastosowaniem środowiska MATLAB & SIMULINK oraz MS Visual Studio. Przeprowadzono badania symulacyjne układu o łącznej mocy znamionowej 60 kW oraz odbiornika o znanej charakterystyce obciążenia. Dla danych pomiarowych irradiancji i prędkości wiatru z obszaru Polski południowo–wschodniej z roku 2011, przeprowadzono obliczenia ilości energii elektrycznej wytwarzanej przez badany układ. Sporządzono bilans energetyczny dla poszczególnych miesięcy. Dla dwóch konfiguracji układu: z magazynem elektrochemicznym i bez magazynu wyznaczono długość okresów braku zasilania odbiornika oraz wartość energii pobranej i oddanej do sieci energetycznej.
The paper presents a model and simulation of hybrid solar-wind power supply system with energy storage, developed using the MATLAB & SIMULINK environment. Simulation tests were carried out for sources with a combined rated power of 60 kW and a receiver with known load characteristics. For the extortion given in the form of irradiance measurements and wind speed from the area of south-eastern Poland for 2011, calculations of the amount of electricity generated by the tested system were carried out. An energy analysis was prepared for individual months. For the system with and without the electrochemical storage, the length of the power failure period and the value of energy collected and delivered to the grid were also determined.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 94; 305-317
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System awaryjnego zasilania domu jednorodzinnego z autonomicznym systemem fotowoltaicznym
Emergency supply system single-family house with an autonomous photovoltaic system
Autorzy:
Noszczyk, T.
Wolny, Ł.
Dyjakon, A.
Powiązania:
https://bibliotekanauki.pl/articles/2065513.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska
Tematy:
zasilanie awaryjne
instalacja PV
off-grid
gospodarstwo domowe
emergency supply
photovoltaic system
off-grid system
household
Opis:
Wiele regionów kraju a szczególnie obszary wiejskie, narażonych jest na przerwy w dostawie energii elektrycznej. Wynika to głównie z przestarzałej infrastruktury energetycznej oraz występujących przeciążeń w okresach szczytowego zapotrzebowania na energię elektryczną. W celu zapewnienia podstawowego funkcjonowania gospodarstwa domowego w awaryjnych warunkach, coraz częściej stosuje się systemy dodatkowego zasilania, w tym także oparte na energii promieniowania słonecznego. W pracy przedstawiono koncepcję mikroinstalacji fotowoltaicznej z układem magazynowania energii w akumulatorach pozwalającej na awaryjne zasilanie podstawowych urządzeń elektrycznych w gospodarstwie domowym. Na podstawie przyjętych założeń i wymaganego zapotrzebowania energetycznego, dobrano podstawowe elementy instalacji, określono koszty inwestycyjne oraz obliczono prosty okres zwrotu SPBT.
Many regions of the country and especially rural areas are exposed to power outages. This is mainly due to outdated energy infrastructure and occurring overloads in periods of peak demand for electricity. In order to ensure the basic functioning of a households in emergency conditions, additional power systems based on solar energy are used. The work presents the concept of photovoltaic micro-solar system with energy storage in batteries that allows for emergency supply of basic electrical appliances in the household. Based on the adopted assumptions and the required energy demand, the basic elements of the installation were selected, the investment costs were determined and the simple payback time (SPBT) was calculated.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2018, 7, 2; 91--98
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and economic evaluation of a heating system based on air-to-water heat pumps with photovoltaic - micro-installation within the Prosument program
Ocena techniczno-ekonomiczna systemu grzewczego opartego na pompach ciepła typu powietrze woda współpracującego z mikroinstalacją fotowoltaiczną w ramach programu Prosument
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/334685.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
final energy consumption
building
air-water heat pump
PV micro-installation
Prosumer program
economic analysis
zużycie energii końcowej
budynek
pompa ciepła typu powietrze-woda
mikroinstalacja PV
program Prosument
analiza ekonomiczna
Opis:
For an exemplary single-family residential building, final energy consumption for heating and domestic hot water preparation was calculated using an air / water heat pump, consumption of electricity for household purposes (lighting, household appliances, RTV, etc.) was also calculated as based on statistical summaries. On this basis, power was selected and the annual production volume was determined by a photovoltaic micro-installation working in the ON-GIRD system pursuant to prosumer regulations contained in the Act on Renewable Energy. Then, an economic analysis was carried out basing on such static and dynamic methods as SPBT, PBP, NPV, IRR and CCE. The calculations were made for two variants, i.e.: the investment costs of the system are borne entirely by the investor, or the installation is purchased within the "EKOkredyt Prosument II" NFEP&WM program. As a result of the calculations, it was found that the investment in PV microinstallation will be profitable only if the support instruments offered by the NFEP&WM program are used. If the investor uses co-financing, the investment will pay back within 16 years at the latest and if he wants to invest his own funds, the waiting period for the return on investments can be extended to up to 21 years, which, given the twenty-five year period of operation, can turn out to be the risk that the funds invested can never be returned.
Dla przykładowego budynku mieszkalnego jednorodzinnego obliczono zużycie energii końcowej do ogrzewania i przygotowania ciepłej wody użytkowej za pomocą pompy ciepła typu powietrze/woda. Określono również w oparciu o zestawienia statystyczne wielkość zużycia energii elektrycznej na cele bytowe (oświetlenie, AGD, RTV, itp.) Na tej podstawie dobrano moc i określono roczną wielkość produkcji przez mikroinstalację fotowoltaiczną pracującą w systemie ON-GIRD w ramach przepisów dotyczących prosumentów zawartych w ustawie o OZE. Następnie przeprowadzono analizę ekonomiczną w oparciu o metody statyczne i dynamiczne takie jak: SPBT, PBP, NPV, IRR oraz CCE. Obliczenia wykonano dla dwóch wariantów, tj.: koszty inwestycyjne systemu ponoszone są w całości przez inwestora lub instalacja jest zakupiona w ramach programu NFOŚiGW „EKOkredyt Prosument II”. W wyniku przeprowadzonych obliczeń stwierdzono, że inwestycja w mikroinstalację PV będzie opłacalna jedynie w przypadku skorzystania z instrumentów wsparcia oferowanych przez program NFOŚiGW. Jeżeli inwestor skorzysta z dofinansowania to inwestycja zwróci się najpóźniej w ciągu 16 lat, natomiast jeżeli będzie chciał zainwestować środki własne okres oczekiwania na zwrot nakładów może wydłużyć się nawet do 21 lat, co przy zakładanym dwudziestopięcioletnim okresie eksploatacji może okazać się, że inwestycja ta będzie niosła za sobą ryzyko, iż zainwestowane środki mogą się nie zwrócić.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2018, 63, 4; 197-202
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of effectiveness of the photovoltaic system Installed on the roof of the University of Opole building
Ocena efektywności systemu fotowoltaicznego zainstalowanego na dachu budynku Uniwersytetu Opolskiego
Autorzy:
Świsłowski, P.
Rajfur, M.
Rodziewicz, T.
Powiązania:
https://bibliotekanauki.pl/articles/387778.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
renewable energy sources
RES
photovoltaics
photovoltaic panels
effectiveness of PV system
PV cell
odnawialne źródła energii
OZE
fotowoltaika
panele fotowoltaiczne
efektywność systemu
PV
ogniwo PV
Opis:
The objective of the carried out study was to analyse and assess effectiveness of the photovoltaic system installed on the roof of the University of Opole building at ul. Kominka 6 in Opole. The scope of the study included an assessment of: power generation – the relation between the panels location and energy yield (quantity of generated electric power and geographical location of photovoltaic panels), economic – the period of return on investment and ecological – ie how much larger the emission of carbon dioxide by the power plant would be during electric power generation, without work of the photovoltaic system. The studies showed good energy yield of the PV installation, typical return on investment period and ecological aspect of the project, ie a considerable reduction of CO2 emission to atmosphere.
Celem przeprowadzonych badań była analiza i ocena pracy wydajności systemu fotowoltaicznego zainstalowanego na dachu budynku Uniwersytetu Opolskiego przy ul. Kominka 6 w Opolu. Zakres pracy obejmował ocenę: energetyczną – zależność usytuowania paneli a uzysk energetyczny (ilość wyprodukowanej energii elektrycznej a położenie geograficzne paneli fotowoltaicznych), ekonomiczną – czas zwrotu poniesionych nakładów inwestycyjnych oraz ekologiczną: tj. ile elektrownia wyemitowałaby więcej dwutlenku węgla do atmosfery w wyniku produkcji energii elektrycznej bez udziału tego systemu fotowoltaicznego. Badania wykazały dobry uzysk energetyczny instalacji PV, typowy okres zwrotu poniesionych nakładów na inwestycję oraz na ekologię przedsięwzięcia w postaci znacznej redukcji emisji CO2 do atmosfery.
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 1; 7-18
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies