Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Mika, Łukasz" wg kryterium: Wszystkie pola


Wyświetlanie 1-10 z 10
Tytuł:
The efficacy of mud pack treatment on ailments related to gonarthrosis
Wpływ terapii z zastosowaniem okładów borowinowych na dolegliwości związane z chorobą zwyrodnieniową stawu kolanowego
Autorzy:
Mika, Anna
Dąbal, Ewa
Mika, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/1935833.pdf
Data publikacji:
2006
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
osteoarthrosis
Knee
mud-pack
therapy
choroba zwyrodnieniowa
Staw kolanowy
borowina
leczenie
Opis:
Background: The aim of this study was to evaluate whether mud pack application as a supplementary treatment to physiotherapy and therapy with physical agents allow to achieve better outcome than physiotherapy and therapy with physical agents alone in patients suffering from gonarthrosis.Methods: Twenty patients aged 49 to 70 at II and III stage of gonarthrosis were divided into experimental and control groups each comprising 10 patients. The experimental group was treated by mud pack, exercises and therapy with physical agents, whereas the control group only by exercises and therapy with physical agents. The following parameters were evaluated in all patients before and two weeks after the therapy: range of motion in the knee, leg circumference, self-assessment of disease severity (using WOMAC questionnaire), and pain level (using VAS scale).Results: We observed that joint stiffness (assessed using WOMAC questionnaire) decreased significantly only in the experimental group (p<0.05). Significant decrease in pain level assessed by means of VAS scale was noticed in both groups (p<0.05). After the therapy, a significant improvement in knee flexion (p<0.05) was observed only in the control group.Conclusion: Both treatment modalities had similar effects on pain severity. Reduction of joints stiffness observed 2 weeks following the treatment may suggest that mud pack may be used as a supplementary component in the therapy of osteoarthrosis.
Cel: Celem niniejszej pracy było ustalenie czy zastosowanie okładów borowinowych jako elementu uzupełniającego kinezyterapię i fizykoterapię pozwoli uzyskać lepszy efekt terapeutyczny u pacjentów z chorobą zwyrodnieniową stawów kolanowych niż zastosowanie leczenia opartego tylko na kinezyterapii i fizykoterapii. Materiał i metoda: Badaniami objęto 20 kobiet w wieku 49-70 lat, u których stwierdzono II° i III° (wg klasyfikacji Seyfrieda) choroby zwyrodnieniowej stawu kolanowego. Wszystkich badanych losowo podzielono na dwie grupy: badaną (n=10) i kontrolną (n=10). W grupie badanej zastosowano: okłady borowinowe, kinezyterapię i fizykoterapię, a w kontrolnej tylko kinezyterapię i fizykoterapię. Pacjentów badano dwukrotnie: bezpośrednio przed rozpoczęciem leczenia i po 2 tygodniach w ostatnim dniu zabiegów. U każdego z badanych przeprowadzono pomiar: zakresu ruchomości w stawie kolanowym i obwodu kończyny, ocenę stopnia dolegliwości wynikających z choroby zwyrodnieniowej przy użyciu kwestionariusza WOMAC, oraz pomiar stopnia intensywności odczuwania bólu za pomocą skali VAS. Wyniki: Stwierdzono, iż odczuwana przez pacjentów sztywność w stawie (badana przy pomocy kwestionariusza WOMAC) statystycznie istotnie zmniejszyła się tylko w grupie badanej (p<0.05). Zauważono, iż w obu grupach po zastosowanej terapii nastąpiło statystycznie istotne zmniejszenie poziomu bólu (p<0.05), ocenianego za pomocą skali VAS. Po 2 tygodniach terapii statystycznie istotny przyrost w zakresie zgięcia (p<0.05) zaobserwowano tylko w grupie kontrolnej. Wnioski: Zarówno leczenie oparte tylko na kinezyterapii i fizykoterapii jak i model uzupełniony o okłady borowinowe wykazuje zbliżone działanie przeciwbólowe. Obserwowane po 2 tygodniach zabiegów obniżenie sztywności stawowej pozwala sugerować, że borowina może być włączona jako element uzupełniający terapię choroby zwyrodnieniowej stawów.
Źródło:
Medical Rehabilitation; 2006, 10(1); 57-66
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chłodzenie adsorpcyjne z wykorzystaniem złóż fluidalnych
Autorzy:
Boruta, Piotr
Bujok, Tomasz
Mika, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/37226384.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
chłodziarki adsorpcyjne
złoża fluidalne
przegląd rozwiązań
Opis:
Jednym z perspektywicznych rozwiązań dla branży chłodniczej jest chłodzenie wykorzystujące zjawisko adsorpcji. Technologia ta umożliwia ograniczenie zużycia energii w chłodnictwie, które w znacznej mierze odpowiada za rosnącą globalną konsumpcję energii. Przedmiotem artykułu jest analiza możliwości rozwoju technologii adsorpcyjnych. Głównym ograniczeniem chłodziarek adsorpcyjnych jest niska intensywność wymiany ciepła i masy w złożu, co prowadzi do niskiej wydajności, a w konsekwencji problemów z komercjalizacją tego rozwiązania. Głównym celem opracowania jest analiza możliwości poprawy transportu ciepła i masy w złożu adsorpcyjnym poprzez zastosowanie złoża fluidalnego. W pracy poddano dyskusji różne stosowane obecnie w przemyśle konstrukcje złóż fluidalnych i oceniono je pod względem możliwości aplikacji w chłodziarkach adsorpcyjnych. Przeanalizowano działanie chłodziarki adsorpcyjnej z czynnikiem pośredniczącym, jak i zapewniającej chłodzenie bezpośrednie. Po przeglądzie dostępnych danych literaturowych przedstawiono możliwości oraz potencjalne ograniczenia związane z rozwojem tej technologii. Ponadto wskazano przypuszczalny kierunek prowadzenia badań doświadczalnych, który obejmuje mechaniczne mieszanie materiału w złożu.
Źródło:
Zeszyty Energetyczne; 2020, 7; 17-38
2658-0799
Pojawia się w:
Zeszyty Energetyczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of adsorption chillers for waste heat recovery
Wykorzystanie chłodziarek adsorpcyjnych do zagospodarowania ciepła odpadowego
Autorzy:
Kuchmacz, Jan
Bieniek, Artur
Mika, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/283345.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
waste heat
heat recovery
energy efficiency
adsorption refrigerators
ciepło odpadowe
odzysk ciepła
efektywność energetyczna
chłodziarka adsorpcyjna
Opis:
The purpose of this article was to discuss the use of adsorption chillers for waste heat recovery. The introduction discusses the need to undertake broader measures for the effective management of waste heat in the industry and discusses the benefits and technical problems related to heat recovery in industrial plants. In addition, heat sources for adsorption chillers and their application examples were described. The principle of operation of adsorption chillers is explained in the next chapter. Heat sources for adsorption chillers are indicated and their application examples are described. The above considerations have allowed the benefits and technical obstacles related to the use of adsorption chillers to be highlighted. The currently used adsorbents and adsorbates are discussed later in the article. The main part of the paper discusses the use of adsorption chillers for waste heat management in the glassworks. The calculations assumed the natural gas demand of 20.1 million m3 per year and the electricity demand of 20,000 MWh/year. As a result of conducted calculations, a 231 kW adsorption chiller, ensuring the annual cold production of 2,021 MWh, was selected. The economic analysis of the proposed solution has shown that the investment in the adsorption chiller supplied with waste heat from the heat recovery system will bring significant economic benefits after 10 years from its implementation, even with total investment costs of PLN 1,900,000. However, it was noted that in order to obtain satisfactory economic results the production must meet the demand while the cost of building a heat recovery system shall not exceed PLN 1 million.
Celem artykułu było rozważenie problemu zagospodarowywania ciepła odpadowego przy wykorzystaniu chłodziarek adsorpcyjnych. Na początku wskazano genezę potrzeby podjęcia szerszych działań na rzecz efektywnego zagospodarowywania ciepła odpadowego w przemyśle oraz omówiono korzyści i problemy techniczne związane z odzyskiem ciepła w zakładach przemysłowych. W następnym rozdziale objaśniono zasadę działania chłodziarek adsorpcyjnych. Z kolei wskazano źródła ciepła dla chłodziarek adsorpcyjnych oraz opisano ich przykładowe zastosowania. Powyższe rozważania pozwoliły na uwypuklenie korzyści i barier technicznych związanych z wykorzystywaniem adsorpcyjnych urządzeń chłodniczych. W następnej części pracy scharakteryzowano stosowane obecnie adsorbenty i adsorbaty. W zasadniczej części pracy przeprowadzono analizę wykorzystania chłodziarek adsorpcyjnych do zagospodarowania ciepła odpadowego w hucie szkła. W obliczeniach rozważono przykładową hutę szkła, której zapotrzebowanie na gaz ziemny wynosi 20,1 mln m3/rok, a zapotrzebowanie na energię elektryczną wynosi 20 000 MWh/rok. W efekcie przeprowadzonych kalkulacji dobrano chłodziarkę adsorpcyjną o mocy 231 kW, która zapewni roczną produkcję chłodu wynoszącą 2021 MWh. Analiza ekonomiczna zaproponowanego rozwiązania wykazała, że inwestycja w chłodziarkę adsorpcyjną zasilaną ciepłem odpadowym z instalacji odzysku ciepła przyniesie znaczące korzyści ekonomiczne po 10 latach od jej zrealizowania nawet przy sumarycznych nakładach inwestycyjnych wynoszących 1 900 000 zł. Zaznaczono jednak, że uzyskanie tak zadawalających wyników ekonomicznych będzie możliwe tylko wtedy, gdy w hucie szkła będzie zapewniony ciągły odbiór chłodu, a koszt budowy instalacji odzysku ciepła nie przekroczy 1 mln zł.
Źródło:
Polityka Energetyczna; 2019, 22, 2; 89-106
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption chiller in a combined heating and cooling system: simulation and optimization by neural networks
Autorzy:
Krzywanski, Jarosław
Sztekler, Karol
Bugaj, Marcin
Kalawa, Wojciech
Grabowska, Karolina
Chaja, Patryk Robert
Sosnowski, Marcin
Nowak, Wojciech
Mika, Łukasz
Bykuć, Sebastian
Powiązania:
https://bibliotekanauki.pl/articles/2128167.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
adsorption heat pump
polygeneration
cooling capacity
low grade thermal energy
artificial neural networks
soft computing
absorpcyjna pompa ciepła
poligeneracja
wydajność chłodnicza
energia cieplna niskiej jakości
sztuczne sieci neuronowe
przetwarzanie miękkie
Opis:
Adsorption cooling and desalination technologies have recently received more attention. Adsorption chillers, using eco-friendly refrigerants, provide promising abilities for low-grade waste heat recovery and utilization, especially renewable and waste heat of the near ambient temperature. However, due to the low coefficient of performance (COP) and cooling capacity (CC) of the chillers, they have not been widely commercialized. Although operating in combined heating and cooling (HC) systems, adsorption chillers allow more efficient conversion and management of low-grade sources of thermal energy, their operation is still not sufficiently recognized, and the improvement of their performance is still a challenging task. The paper introduces an artificial intelligence (AI) approach for the optimization study of a two-bed adsorption chiller operating in an existing combined HC system, driven by low-temperature heat from cogeneration. Artificial neural networks are employed to develop a model that allows estimating the behavior of the chiller. Two crucial energy efficiency and performance indicators of the adsorption chiller, i.e., CC and the COP, are examined during the study for different operating sceneries and a wide range of operating conditions. Thus this work provides useful guidance for the operating conditions of the adsorption chiller integrated into the HC system. For the considered range of input parameters, the highest CC and COP are equal to 12.7 and 0.65 kW, respectively. The developed model, based on the neurocomputing approach, constitutes an easy-to-use and powerful optimization tool for the adsorption chiller operating in the complex HC system.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; e137054, 1--11
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adsorption chiller in a combined heating and cooling system: simulation and optimization by neural networks
Autorzy:
Krzywanski, Jarosław
Sztekler, Karol
Bugaj, Marcin
Kalawa, Wojciech
Grabowska, Karolina
Chaja, Patryk Robert
Sosnowski, Marcin
Nowak, Wojciech
Mika, Łukasz
Bykuć, Sebastian
Powiązania:
https://bibliotekanauki.pl/articles/2173577.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
adsorption heat pump
polygeneration
cooling capacity
low grade thermal energy
artificial neural networks
soft computing
absorpcyjna pompa ciepła
poligeneracja
wydajność chłodnicza
energia cieplna niskiej jakości
sztuczne sieci neuronowe
przetwarzanie miękkie
Opis:
Adsorption cooling and desalination technologies have recently received more attention. Adsorption chillers, using eco-friendly refrigerants, provide promising abilities for low-grade waste heat recovery and utilization, especially renewable and waste heat of the near ambient temperature. However, due to the low coefficient of performance (COP) and cooling capacity (CC) of the chillers, they have not been widely commercialized. Although operating in combined heating and cooling (HC) systems, adsorption chillers allow more efficient conversion and management of low-grade sources of thermal energy, their operation is still not sufficiently recognized, and the improvement of their performance is still a challenging task. The paper introduces an artificial intelligence (AI) approach for the optimization study of a two-bed adsorption chiller operating in an existing combined HC system, driven by low-temperature heat from cogeneration. Artificial neural networks are employed to develop a model that allows estimating the behavior of the chiller. Two crucial energy efficiency and performance indicators of the adsorption chiller, i.e., CC and the COP, are examined during the study for different operating sceneries and a wide range of operating conditions. Thus this work provides useful guidance for the operating conditions of the adsorption chiller integrated into the HC system. For the considered range of input parameters, the highest CC and COP are equal to 12.7 and 0.65 kW, respectively. The developed model, based on the neurocomputing approach, constitutes an easy-to-use and powerful optimization tool for the adsorption chiller operating in the complex HC system.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; art. no. e137054
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The dependence on posture of temporalis and masseter bioelectrical muscle activity
Ocena aktywności bioelektrycznej mięśni skroniowych i żwaczy w zależności od postawy ciała
Autorzy:
Kielnar, Renata
Mika, Anna
Oleksy, Łukasz
Jureczko, Paweł
Marchewka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1963078.pdf
Data publikacji:
2011
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
SEMG
cervical spine
masticatory system
Opis:
Background: Masticatory dysfunctions are a common problem in society today. Disorders such as clenching, bruxism can lead to a loosening of teeth in the jaw, abrasion of the tooth crowns, inflammatory changes, and ultimately degenerative changes in the temporo-mandibular joints.Aim: The aim of this study was to assess the relationship between masseter and temporalis anterior muscles activity and body posture.Material and Methods: In 20 subjects (20-35 years) the sEMG of the masseter and temporalis anterior muscles was measured twice during functional clenching: in casual posture and in posture with the head in retraction. The study was conducted using sEMG Tele-Myo (Noraxon). Results: The bioelectrical activity of the evaluated muscles was significantly higher in the casual posture than in retraction (p<0.05). Temporomandibular disorders appear not only due to facial muscle activity abnormalities, but also due to incorrect body posture, especially a head forward posture. The measurement was performed twice in a sitting position: in casual posture and in a posture with the head in retraction. Mean masseter activity during teeth clenching was statistically significant in retraction compared to the habitual position (p<0.05), both for the left and right side. There was also statistically significant activity in the temporalis muscles in retraction compared to the habitual position.Conclusion: The observed decreased activities in both the masseters and temporalis muscles suggest that masticatory system dysfunctions may not only be the result of dysfunction in the craniofacial region but also may be posture dependent.
Źródło:
Medical Rehabilitation; 2011, 15(4); 10-14
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
From the treadmill to the exoskeleton. Evolution of mechanical gait assistance methods
Od bieżni do egzoszkieletów – ewolucja metod mechanicznego wspomagania chodu
Autorzy:
Rojek, Anna
Zwolińska-Mirek, Katarzyna
Oleksy, Łukasz
Cygoń, Krzysztof
Michałek, Adrian
Janiszewska, Natalia
Mika, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1808040.pdf
Data publikacji:
2015
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
Gait
e-education
robot
Exoskeleton
chód
reedukacja
egzoszkielet
Opis:
Limited independent walking and the resulting disabilities are a serious issue for a growing group of patients. These patients are often dependent on a wheelchair, or are bedridden until the end of their lives. For this reason, the development of gait re-education methods and devices for mechanical gait assistance are very important elements in maintaining or regaining a high quality of daily and social life. New technologies allow for the construction of devices that support the rehabilitation process, which reduce the workload of therapists and ensure the best execution of the patients’ movement patterns. This paper presents the development of devices used for the mechanical support of gait starting from the simplest ones like treadmills or standing frames, through stationary robots, to the most technologically advanced ones, i.e. exoskeletons. An exoskeleton is a wearable robot which supports, or in some cases, substitutes for the user’s own movements. The first attempts to create such devices were undertaken 40 years ago. This paper discusses their clinical applications and their effectiveness in gait re-education based on the existing scientific evidence. These new technologies in gait re-education are now becoming an integral part of the rehabilitation process.
Źródło:
Medical Rehabilitation; 2015, 19(4); 25-33
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intrarater reliability of the Foot Posture Index (FPI-6) applied as a tool in foot assessment in children and adolescents
Foot Posture Index (FPI-6) w badaniu stóp u dzieci i młodzieży – rzetelność testu powtarzanego przez tego samego badającego
Autorzy:
Oleksy, Łukasz
Mika, Anna
Łukomska-Górny, Anna
Marchewka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1957149.pdf
Data publikacji:
2010
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
Foot
children
adolescents
assessment
test
FPI-6
Reliability
stopa
dzieci
młodzież
badanie
rzetelność
Opis:
Background: The evaluation of proper foot posture is of importance in diagnosis. All abnormalities in the foot structure may reflect the pathogenesis of the dysfunctions presented at other parts of the body. There are many diagnostic devices for foot assessment, but the results obtained using different methods are often not comparable. Foot Posture Index (FPI-6) was created as a quick, simple and reliable tool for quantifying foot posture in a variety of clinical settings.Aim: The evaluation of foot posture in 3 age groups of children using FPI-6 and the assessment of the reliability of this methodMaterial and Methods: 60 subjects in 3 age groups 9, 12 and 14 years participated in the study. For the purpose of FPI-6 reliability level determination all measurements were taken twice, with a 2-week gap. The following variables were evaluated: body height, body mass, BMI (Body Mass Index), the foot assessment using FPI-6.Results: The correlation coefficient R between the first and second measurement for all criterion was 0.89-0.96, what indicates a very good FPI-6 reliability in the foot assessment. Both the inversion/eversion of the calcaneus and abduction/adduction of the forefoot on the rear foot in the groups of 9- and 12-year-old children indicated mild foot pronation, and those parameters changed significantly in 14-year-old children where values were reached typical for a neutral foot.Conclusion: FPI-6 it is a simple and reliable tool for comprehensive foot evaluation, which allows one to use it both in clinical practice as in preventive population based studies.
Wstęp: Ocena prawidłowego ukształtowania stóp ma bardzo istotne znaczenie diagnostyczne. Wszelkie odchylenia w ich budowie mają odzwierciedlenie w patogenezie schorzeń w obrębie innych części ciała. Istnieje wiele narzędzi do oceny stóp, jednakże wyniki uzyskiwane różnymi metodami nie zawsze są porównywalne. Foot Posture Index (FPI–6) został opracowany jako szybkie, łatwe w użyciu i rzetelne narzędzie służące do oceny stóp w różnych zastosowaniach klinicznych.Cel pracy: Oznaczenie współczynnika powtarzalności pomiarowej dla kwestionariusza FPI-6 zastosowanego do badania stóp u dzieci i młodzieży.Materiał i Metoda: W badaniach wzięło udział 60 osób w trzech grupach wiekowych 9, 12 i 14 lat. W celu określenia powtarzalności pomiarowej FPI-6 wszystkie pomiary przeprowadzono dwukrotnie w 2 tygodniowym odstępie czasowym. Oceniano następujące parametry: wysokość ciała, masa ciała, BMI (Body Mass Index), oraz wykonano ocenę stóp za pomocą FPI-6. Wyniki: Wartość współczynnika powtarzalności R pomiędzy pierwszym i drugim badaniem, dla wszystkich parametrów wynosił 0.89-0.96, co oznacza bardzo dobrą powtarzalność FPI -6 w ocenie stopy. Wysokie wartości współczynnika powtarzalności występują niezależnie od wieku dziecka, wysokości i masy ciała. Zarówno ocena koślawości i szpotawości kości piętowej jak i ocena przywiedzenia /odwiedzenia przodostopia względem kości piętowej w grupach dzieci dziewięcioletnich i dwunastoletnich uzyskały wartości mówiące o lekkiej pronacji stopy, a w grupie dzieci czternastoletnich parametry te ulegały statystycznie istotnej zmianie uzyskując wartości charakterystyczne dla neutralnego ustawienia stopy.Wnioski: FPI-6 jest prostym i rzetelnym narzędziem oceny stopy u dzieci i młodzieży, charakteryzującym się wysokim współczynnikiem zgodności pomiarów powtarzanych przez tego samego badającego.
Źródło:
Medical Rehabilitation; 2010, 14(4); 18-28
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A proposal for the application of the Carpal Tunnel Syndrome evaluation method using surface electromyography: A pilot study
Propozycja metody oceny zespołu kanału nadgarstka z wykorzystaniem elektromiografii powierzchniowej – badanie pilotażowe
Autorzy:
Oleksy, Łukasz
Mika, Anna
Pieniążek, Marek
Marchewka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1972301.pdf
Data publikacji:
2009
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
surface electromiography
sequence test
fatigue test
Carpal Tunnel Syndrome
strain injury
RSI
elektromiografia powierzchniowa
test sekwencyjny
test zmęczenia
zespół kanału nadgarstka
uraz
przeciążenie
Opis:
Background: Carpal Tunnel Syndrome (CTS), frequently considered to be an occupational disease, is difficult to diagnose because of the many additional factors which may mask its real symptoms. A significant part of differential diagnosis is to find a method that is adequately sensitive and noninvasive.Aim: Evaluation of selected muscles’ bioelectrical activity in order to attain preliminary guidelines in a differential diagnosis of CTS.Material and method: 30 patients with CTS after surgical carpal tunnel release and 15 healthy controls were examined. Thebioelectrical activity of the cervical paraspinal muscles, sternocleidomastoideus, flexores carpi radialis and extensors carpi radialis longus were measured during cervical functional tests, and during a fatigue test for flexores carpi radialis and extensors carpi radialis longus.Results: In the cervical sequence test the correct asymmetrical activity pattern was observed in the control group during cervical rotation and cervical flexion both in the sternocleidomastoideus and cervical paraspinal muscles. In CTS patients no significant difference (p>0,05) between the right and left sternocleidomastoideus was observed in cervical rotation and cervical flexion. In cervical paraspinal there was no significant difference during rotation, but during the flexion activity of the right and left side muscles there was noted significant difference, though less than in the control group. After the fatigue test there was observed a significant increase in the CTS group and a significant decrease in the control group in extensors carpi radialis activity.Conclusion: Even if we are unable to unambiguously diagnose CTS symptoms using sEMG, the increased resting extensors carpi radialis bioelectrical activity observed after fatigue test in CTS patients, yet decreased in the control group, allow us to suggest that the evaluation of muscles fatigue using sEMG is an appropriate method in the evaluation of muscles’ bioelectrical activity disorders.
Wstęp: Zespół kanału nadgarstka (CTS) jako najczęstsza postać neuropatii uciskowej kończyny górnej, pomimo licznych objawów jest trudny w diagnostyce, szczególnie w początkowym okresie choroby, gdy uszkodzenie nerwu jest niewielkie i trudno jest jednoznacznie stwierdzić charakterystyczne objawy ubytkowe. Cel pracy: Ocena aktywności bioelektrycznej wybranych mięśni będąca podstawą do opracowania wstępnych wytycznych diagnostyki różnicowej zespołu kanału nadgarstka z wykorzystaniem sEMG. Materiał i Metoda: Przebadano 30 pacjentów ze zdiagnozowanym zespołem kanału nadgarstka, u których dokonano chirurgicznego uwolnienia nerwu pośrodkowego w kanale nadgarstka oraz 15 osób zdrowych. Ocenę sEMG mięśni przykręgosłupowych w odcinku szyjnym, mięśni mostkowo-obojczykowo-sutkowych, zginaczy promieniowych nadgarstka oraz prostowników promieniowych długich nadgarstka przeprowadzono w sekwencji testów funkcjonalnych dla odcinka szyjnego kręgosłupa, oraz podczas testu zmęczenia dla zginaczy promieniowych nadgarstka i prostowników promieniowych długich nadgarstka. Wyniki: W teście sekwencyjnym dla odcinka szyjnego kręgosłupa w grupie osób zdrowych zaobserwowano prawidłowy, asymetryczny wzorzec aktywności podczas rotacji i zgięcia bocznego, zarówno w obrębie mięśni mostkowo-obojczykowo-sutkowych jak i przykręgosłupowych w odcinku szyjnym. Natomiast u pacjentów z CTS mięśnie mostkowo-obojczykowo-sutkowe wykazywały podobną aktywność bioelektryczną po obu stronach, zarówno podczas ruchów rotacji jak i podczas zgięć bocznych, a różnica pomiędzy prawym i lewym mięśniem w danym ruchu nie była istotna statystycznie (p>0,05). W obrębie mięśni przykręgosłupowych nie zaobserwowano statystycznie istotnej różnicy w aktywności po prawej i lewej stronie podczas rotacji. Natomiast podczas zgięć bocznych różnica była istotna statystycznie, lecz mniejsza niŜ u osób zdrowych. U pacjentów z CTS obserwowano po zmęczeniu statystycznie istotnie zwiększoną aktywność spoczynkową prostowników promieniowych długich nadgarstka i statystycznie istotnie zmniejszoną aktywność tych mięśni u osób zdrowych. Wnioski: Pomimo, iŜ za pomocą sEMG nie jesteśmy w stanie jednoznacznie zdiagnozować zespołu kanału nadgarstka, jednakŜe obserwowana po zmęczeniu u pacjentów z CTS zwiększona aktywność spoczynkowa prostowników promieniowych nadgarstka i zmniejszona aktywność tych mięśni u osób zdrowych pozwala przypuszczać, Ŝe ocena zmęczenia mięśni za pomocą sEMG jest właściwą metodą diagnostyczną zaburzeń ich aktywności bioelektrycznej.
Źródło:
Medical Rehabilitation; 2009, 13(4); 9-16
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the influence of low and high heel shoes on erector spine muscle bioelectrical activity assessed at baseline and during movement
Ocena wpływu obuwia na niskich i na wysokich obcasach na aktywność bioelektryczną mięśnia prostownika kręgosłupa ocenianą w spoczynku i podczas ruchu
Autorzy:
Mika, Anna
Oleksy, Łukasz
Mikołajczyk, Edyta
Marchewka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1942933.pdf
Data publikacji:
2009
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
surface electromyography
lumbar spine
heel shoes
sequence test
elektromiografia powierzchniowa
kręgosłup lędźwiowy
obcasy
test sekwencyjny
Opis:
Introduction: Back pain due to the wearing of high heel shoes may result from increased erector spine activity and also from higher proximal ground reaction forces or center of body mass dislocation.Aim: The assessment of changes in the erector spine muscle due to the non-physiological foot position in low and high heel shoes.Material and Methods: In 31 women aged 20-25 years (height 167,6 ±5.8 cm; weight 60,35 ±6,49 kg) without back pain, the bioelectrical activity of the erector spine muscle was assessed. A lumbar spine sequence test was performed without shoes and in low (4 cm) and in high (10 cm) heel shoes. Muscle activity on the right and left sides was evaluated at baseline and during movement. The mean and peak signal value were compared between 3 measurements (without, in low and in high heel shoes).Results: A statistically significant increase in erector spine activity was observed in Trunk Flexion (p<0,05) and during Flexion-Relaxation Position (p<0,05) when wearing high hell shoes. Those variables correlated significantly in all 3 measurements (without, in low and in high heel shoes). A significant correlation was noted between the Flexion-Relaxation Position and Extension/Flexion Ratio (p<0,05). Bioelectrical erector spine activity differed significantly during Rotation Right and Rotation Left in all 3 measurements respectively (p<0,05).Conclusion: The prolonged wearing of shoes with stiletto type low and high heels by individuals without back pain is not safe for their spine and may lead to chronic paraspinal muscle fatigue
Źródło:
Medical Rehabilitation; 2009, 13(3); 9-18
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies