Tytuł:
Nowe aspekty elastografii fali poprzecznej w diagnostyce raka stercza
New aspects in shear-wave elastography of prostate cancer
Autorzy:
Porsch, Markus
Wendler, Johann Jakob
Liehr, Uwe-Bernd
Lux, Anke
Schostak, Martin
Pech, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1053586.pdf
Data publikacji:
2015
Wydawca:
Medical Communications
Tematy:
elastography
prostate biopsy
prostate cancer
shear wave
ultrasound
biopsja stercza
elastografia
fala poprzeczna
rak prostaty
ultrasonografia
Opis:
Aim: This study was designed to evaluate the performance of shear-wave elastography as a diagnostic tool for prostate cancer in a larger cohort of patients than previously reported. Patients and methods: Seventy-three patients with suspected prostate carcinoma were investigated by ultrasound elastography followed by directed biopsy. The elastographic and histological results for all biopsies were compared. Results: After exclusion of invalid and non-assessable results, 794 samples were obtained for which both a histological assessment and an elastometric result (tissue stiffness in kPa) were available: according to the histology 589 were benign and 205 were malignant. Tissue elasticity was found to be weakly correlated with patient’s age, PSA level and gland volume. ROC analysis showed that, for the set of results acquired, elastometry did not fulfi l literature claims that it could identify malignant neoplasia with high sensitivity and specifi city. However, it did show promise in distinguishing between Gleason scores ≤6 and >6 when malignancy had already been identifi ed. Unexpected observations were the fi nding of a smaller proportion of tumours in the lateral regions of the prostate than generally expected, and also the observation that the elasticity of benign prostate tissue is region-sensitive, the tissue being stiffest in the basal region and more elastic at the apex. Conclusions: Shear-wave elastography was found to be a poor predictor of malignancy, but for malignant lesions an elasticity cut-off of 80 kPa allowed a fairly reliable distinction between lesions with Gleason ≤6 and those with Gleason >6. We demonstrate an increase in elasticity of benign prostate tissue from the basal to the apical region.
Cel: Badanie przeprowadzono w celu ustalenia wartości diagnostycznej elastografi i fali poprzecznej w raku stercza, analizując większą grupę chorych, niż dotychczas przedstawiano w piśmiennictwie. Pacjenci i metoda: Badaniem objęto 73 pacjentów z podejrzeniem raka stercza. Ocenę gruczołu krokowego wykonywano za pomocą elastografi i, po której stosowano biopsję celowaną. Wyniki: Po wykluczeniu nieważnych i trudnych do oceny wyników uzyskano 794 przypadki, które oceniono zarówno histopatologicznie, jak i metodą elastografi i (sztywność tkanek mierzona w kPa), stwierdzając w badaniu histopatologicznym 589 zmian łagodnych i 205 złośliwych. Wykazano słabą korelację sprężystości tkanek z wiekiem chorych, poziomem PSA i objętością gruczołu krokowego. Analiza ROC otrzymanych wyników udowodniła, że elastometria w diagnostyce ognisk złośliwego nowotworzenia nie jest tak czułą i swoistą metodą, jak zakładano w piśmiennictwie. W przypadkach, w których zdiagnozowano proces złośliwy, metoda ta umożliwia rozróżnienie ognisk ocenianych w skali Gleasona ≤6 od tych >6 punktów. Te nieoczekiwane obserwacje dotyczyły mniejszego odsetka nowotworów, niż wcześniej zakładano, położonych w bocznych częściach prostaty. Ponadto zaobserwowano zależność między poziomem sprężystości tkanek objętych procesem łagodnym w poszczególnych częściach gruczołu krokowego: największą sztywność wykazano w części podstawnej, a większą sprężystość w części wierzchołkowej. Wnioski: Elastografi a fali poprzecznej jest słabym predyktorem złośliwości, chociaż w diagnostyce ognisk złośliwych, z punktem odcięcia poziomu sprężystości wynoszącym 80 kPA, umożliwia dość wiarygodne zróżnicowanie zmian o stopniu zaawansowania ≤6 punktów i zmian o stopniu zaawansowania >6 punktów w skali Gleasona.
Źródło:
Journal of Ultrasonography; 2015, 15, 60; 5-14
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inability of shear-wave elastography to distinguish malignant from benign prostate tissue – a comparison of biopsy, whole-mount sectioning and shear-wave elastography
Elastografia fali poprzecznej nie pozwala na odróżnienie zmian w sterczu o charakterze złośliwym i łagodnym – analiza porównawcza wyników biopsji, badania histopatologicznego i elastografii
Autorzy:
Porsch, Markus
Görner, Claudia
Wendler, Johann Jakob
Liehr, Uwe-Bernd
Lux, Anke
Siedentopf, Sandra
Schostak, Martin
Pech, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/1051242.pdf
Data publikacji:
2016
Wydawca:
Medical Communications
Tematy:
biopsja stercza
elastografia
elastography
fala poprzeczna
prostate biopsy
prostate cancer
rak stercza
shear wave
ultrasonografia
ultrasound
Opis:
Aim: This study was designed to assess the possible usefulness of shear-wave elastography in differentiating between benign and malignant tissue in prostate neoplasia. Patients and methods: A total of 120 prostate tissue samples were obtained from 10 patients treated by radical prostatectomy and investigated pre-operatively by ultrasound elastography followed by directed biopsy. After resection, whole-mount sectioning and histological examination was performed. The predictions based on shear-wave elastography were compared with biopsy and histological results. Results: The comparison between the results of shear-wave elastography and those of biopsy was performed by receiver operating characteristic analysis, which suggested an optimum cut-off tissue elasticity value of 50 kPa, in agreement with earlier studies aimed at distinguishing between benign and malignant tissue. However, the diagnostic selectivity (and thus the diagnostic power) was poor (area under the curve 0.527, which hardly differs from the value of 0.500 that would correspond to a complete lack of predictive power); furthermore, application of this cut-off value to the samples led to a sensitivity of only 74% and a specificity of only 43%. An analogous comparison between the results of shear-wave elastography and those of whole-mount histology, which itself is more reliable than biopsy, gave an even poorer diagnostic selectivity (sensitivity of 62%, specificity of 35%). Meaningful association with Gleason score was not found for D’Amico risk groups (p = 0.35). Conclusions: The (negative) findings of this investigation add to the dissonance among results of studies investigating the possible value of shear-wave elastography as a diagnostic tool to identify malignant neoplasia. There is a clear need for further research to elucidate the diversity of study results and to identify the usefulness, if any, of the method in question.
Cel pracy: Celem badania była ocena użyteczności elastografii fali poprzecznej w odróżnianiu zmian złośliwych stercza od łagodnych. Pacjenci i metody: W sumie uzyskano 120 próbek tkanek gruczołu krokowego od 10 pacjentów, u których przeprowadzono zabieg radykalnej prostatektomii, poprzedzony biopsją i badaniem elastograficznym. Po resekcji wykonano badanie histopatologiczne pełnych przekrojów poprzecznych preparatu. Przypuszczenia wysunięte po elastografii fali poprzecznej porównano z wynikami biopsji i badania histopatologicznego. Wyniki: Wyniki badania elastograficznego i biopsji porównano za pomocą analizy wskaźnika zmian, w której określono optymalną wartość odcięcia dla sztywności tkanek na poziomie 50 kPa, co jest zgodne z wcześniejszymi badaniami prowadzonymi w celu rozróżnienia zmian złośliwych oraz łagodnych. Jednak selektywność diagnostyczna (a tym samym moc diagnostyczna) metody okazała się niska (pole powierzchni pod krzywą wyniosło 0,527, co tylko nieznacznie różni się od wartości 0,500, odpowiadającej zupełnemu brakowi mocy predykcyjnej). Ponadto czułość i swoistość po zastosowaniu tej wartości odcięcia wyniosły odpowiednio 74% i 43%. Analogiczna analiza, porównująca wyniki badania elastograficznego i histologicznego, które samo w sobie jest bardziej miarodajne niż biopsja, wykazała jeszcze niższą selektywność diagnostyczną metody (czułość 62%, swoistość 35%). Nie zaobserwowano znaczącej korelacji między stopniem w skali Gleasona i grupami ryzyka określonymi przez D’Amico (p = 0,35). Wnioski: Powyższe (negatywne) obserwacje zwiększają dysonans między dostępnymi wynikami badań dotyczących potencjalnej wartości diagnostycznej elastografii fali poprzecznej w nowotworach złośliwych. Konieczne są więc dalsze badania, wyjaśniające rozbieżność dotychczasowych obserwacji, aby jednoznacznie określić przydatność opisywanej metody (bądź potwierdzić jej brak).
Źródło:
Journal of Ultrasonography; 2016, 16, 67; 348-358
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies