Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Magnetic exposure" wg kryterium: Wszystkie pola


Tytuł:
Magnetic biostimulation of wheat seeds
Autorzy:
Pietruszewski, S.
Kornarzynski, K.
Powiązania:
https://bibliotekanauki.pl/articles/26349.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
germination speed
wheat
magnetic exposure time
germination capacity
magnetic biostimulation
seed
Źródło:
International Agrophysics; 1999, 13, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of magnetic energy on protein contents in the fifth instar larvae of silkworm, Bombyx mori (L) (Race: PM x CSR2)
Autorzy:
Shivpuje, Madhuri Anil
Hanumant V., Wanve
Belpatre, Sadashiv N.
Khyade, Vitthalrao B.
Powiązania:
https://bibliotekanauki.pl/articles/1190139.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Magnetic exposure
Protein content
Silk Glands
Fat Bodies
Haemolymph
PM x CSR2
Opis:
The fifth instar larvae of multivoltine crossbreed race (PM x CSR2) of silkworm, Bombyx mori (L) were exposed to the magnetic energy of various strengths (1000, 2000, 3000 and 4000 Gauss magnetic field). The magnetization of fifth instar larvae was carried out on the first four days, for half an hour for each day before first feeding. Bioassay of total proteins was carried out on the fifth day of fifth instars. The attempt reveals influence of magnetization of Bombyx mori larvae on the total protein content level in the silk glands, fat bodies and haemolymph. The total protein content was increased with increase in the strength of magnetic field from 1000 to 4000 Gauss magnetic field. The larvae magnetized with 4000 Gauss magnetic field were found with sustained or decreased in total protein contents. Silk gland total proteins were increased from 5.901 to 17.481 percent. Total proteins of fat bodies were increased from 18 to 46.517 percent. And the total proteins of haemolymph were increased from 16.606 to 33.588 percent. Magnetization may have had influence on the increase in the levels of amino acids followed by accelerated rate of protein synthesis in the fifth instar larvae of silkworm, Bombyx mori (L) (Race: PM x CSR2). Magnetic energy should be utilized as efficiently as possible for the progression of growth of larval instars of silkworm, Bombyx mori (L).
Źródło:
World Scientific News; 2016, 42; 73-86
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of pre-sowing magnetic biostimulation on germination and yield of wheat
Autorzy:
Pietruszewski, S.
Powiązania:
https://bibliotekanauki.pl/articles/24995.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
wheat
Jara cultivar
wheat cultivar
yield
Henika cultivar
magnetic biostimulation
magnetic exposure dose
germination
Źródło:
International Agrophysics; 1999, 13, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomaganie biologicznego oczyszczania ścieków polem magnetycznym
Enhancement of biological wastewater treatment by magnetic field exposure
Autorzy:
Tomska, A.
Powiązania:
https://bibliotekanauki.pl/articles/297531.pdf
Data publikacji:
2009
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
pole magnetyczne
osad czynny
biodegradacja
nitryfikacja
magnetic field
activated sludge
biodegradation
nitrification
Opis:
W pracy przedstawiono wyniki badań wpływu pola magnetycznego o indukcji 40 mT na usuwanie związków organicznych, przemiany związków azotu oraz aktywność oddechową mikroorganizmów nitryfikacyjnych podczas oczyszczania ścieków metodą osadu czynnego. Badania realizowano dla dwóch temperatur: w serii I dla 22 ± 2°C i w serii II dla 14 ± 1°C. W obu seriach badania prowadzono w dwóch równolegle pracujących układach laboratoryjnych do hodowli osadu czynnego. W jednym z układów na przewodzie przeznaczonym do recyrkulacji osadu czynnego z osadnika wtórnego do komory napowietrzania zainstalowano jedną parę magnesów stałych, a drugi stanowił układ kontrolny. Badania wykazały, że okresowe eksponowanie osadu czynnego w polu magnetycznym o indukcji 40 mT z wykorzystaniem magnesów stałych nie intensyfikowało eliminacji związków organicznych ze ścieków. Analiza przemian związków azotowych wykazała natomiast, że eliminacja azotu organicznego i Kjeldahla przebiegała efektywniej w układach, w których osad czynny okresowo eksponowano w polu magnetycznym. Potwierdzeniem intensywniejszych przemian związków azotu w układach, w których zainstalowano magnesy, jest również wyższa szybkość nitryfikacji. Badania nad aktywnością oddechową mikroorganizmów osadu czynnego pokazują, że okresowe eksponowanie osadu czynnego w polu magnetycznym o indukcji 40 mT intensyfikowało aktywność oddechową niryfikantów II fazy.
In resent years increasing attention has been directed to the possibility of improvement of waste water treatment by static magnetic field. In this paper the results of investigations on the effect of magnetic field at induction 40 mT on organic compounds removal were presented. Moreover, the transformation of nitrogen compounds and the oxygen uptake rate of nitrifying microorganism in activated sludge wastewater treatment process were determined. The research was carried out at two temperatures - 22 ± 2°C (series I) and 14 ± 1°C (series II). The experiments were performed in two simultaneously operating laboratory activated sludge units. In one of the unit a pair of permanent magnets was installed on the pipe used to recycle of activated sludge from the secondary clarifier to the aeration vessel. The second one was a control unit. The process was realized keeping beneficial sludge age for nitrification process in the range from 15 d to 10 d (series I) and from 13 d to 12 d (series II). The dissolved oxygen concentration in the aeration vessel was kept at the level above 2 mgO2/dm3. The data show that the activated sludge exposure to magnetic field did not affect on the organic pollution removal. However, the analysis of nitrogen compounds transformations shows that elimination of organic and Kjeldahl nitrogen was more effective for the unit where activated sludge was exposed to magnetic field. The elimination of organic nitrogen for the unit with magnets was higher from 2 to 7% in the first series and from 4 to 16% in the second series as compare with the control unit. The studies on oxygen uptake rate of activated sludge microorganisms show also that the nitrification process was more effective for unit where magnets were installed. In every measuring day the oxygen uptake rate of the nitrification was higher for unit with magnets as compare with the control unit. The results show that magnetic field could be an improving factor for nitrification of domestic wastewater by activated sludge.
Źródło:
Inżynieria i Ochrona Środowiska; 2009, 12, 3; 197-206
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Realistyczny model MES centralnego układu nerwowego człowieka w analizie pola elektromagnetycznego
Realistic FEM model of human central nervous system in magnetic field exposure analysis
Autorzy:
Chaber, B.
Szmurło, R.
Sawicki, B.
Powiązania:
https://bibliotekanauki.pl/articles/159385.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
pole magnetyczne
centralny układ nerwowy
metoda elementów skończonych
stymulacja magnetyczna
Opis:
Artykuł opisuje proces tworzenia trójwymiarowego modelu centralnego układu nerwowego człowieka z uwzględnieniem otoczenia: czaszki, rdzenia kręgowego oraz tkanek miękkich. W pracy przedstawiono zastosowaną przez autorów procedurę tworzenia modelu oraz wykorzystanie go do wyznaczenia wpływu pola magnetycznego niskiej częstotliwości na rzeczywisty centralny układ nerwowy. Przy pomocy utworzonego modelu zbadano wpływ polaryzacji pola na powstawanie prądów wirowych w obszarze mózgu, móżdżku i rdzenia kręgowego.
This paper presents a process of creating a 3D finite element model of human central nervous system. The description of segmentation and alignment of CT slices from Visible Human Project database is presented. Application of the realistic model is presented on the example of analysis of low frequency magnetic field exposure on central nervous system.
Źródło:
Prace Instytutu Elektrotechniki; 2010, 247; 183-193
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu ekspozycji niskoczęstotliwościowego pola magnetycznego (f=7 Hz, B=330 nT) na czynność bioelektryczną serca
The effects of low-frequency magnetic filed exposure (f=7 Hz, B=330 nT) on the level of bioelektric activity of human heart
Autorzy:
Damijan, Z.
Powiązania:
https://bibliotekanauki.pl/articles/328543.pdf
Data publikacji:
2007
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
niskoczęstotliwościowe pole magnetyczne
czynność bioelektryczna
serce
low-frequency magnetic filed
bioelectric activity
heart
Opis:
W badaniach wykonanych w 2003 roku nt. wpływu infradźwięków na organizm człowieka, prowadzonych w kabinie ciśnieniowej wyposażonej w siatkę Faradaya, do ekspozycji bodźca stosowano głośniki elektrodynamiczne. Czynnikiem zakłócającym w eksperymencie pozostawało niskoczęstotliwościowe pole magnetyczne (PM). Autor postawił pytanie, czy ekspozycja PM (f =7 Hz, B=330 nT) może wpływać na czynność bioelektryczną serca. Na estymatę wpływu zaproponowano częstość występowania załamków QRS w sygnale EKG. Każdy 35 minutowy, eksperyment składał się z trzech etapów. Etap I - 5 minutowy - bez ekspozycji bodźca. Etap II - z 20 minutową ekspozycją na uczestników - pola magnetycznego niskiej częstotliwości. Trzeci etap - 10 minutowy - bez ekspozycji bodźca. W każdym eksperymencie w sposób ciągły rejestrowano sygnał EKG. Otrzymane wyniki i przeprowadzone analizy wskazują, że ekspozycja " bardzo słabego" PM nie wpływa na czynność bioelektryczną serca. Zastosowany podział psychologiczny różnicujący uczestników ze względu na cechy charakteru wskazał jednak, że na ekspozycję są wrażliwe osoby mające niską wartość wskaźnika Z - potrzeb sensorycznych.
A research program was undertaken in 2003 to investigate the effects of infrasound exposure on humans. Experiments were conducted in the pressure cabin equipped with a Faraday cage. The applied excitations were generated by electrodynamic speakers. Low-frequency magnetic field (MF) remained as a disturbing agent. The author put forward the hypothesis that MF exposure (f=7 Hz, B=330 nT) might affect the bioelectric activity of heart. These impacts are estimated on the basis of frequency of QRS waves in ECG. Each experiment lasted 35 minutes and involved three stages. In the first stage (1-5 min) there was no MF exposure. During the second stage participants were exposed to low-frequency magnetic field for 20 min. In the third stage (10 min) no MF exposure was applied. In each experiments the ECG records were monitored on the permanent basis. Research data show that exposure to "very weak" magnetic field does not affect bioelectric activity of heart. Participants were divided into groups depending on their psychological profiles. Participants displaying low value of Z factor (expressing sensation-seeking needs) appear to be more sensitive to MF exposure.
Źródło:
Diagnostyka; 2007, 1(41); 55-59
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health Risk Assessment of Occupational Exposure to a Magnetic Field From Magnetic Resonance Imaging Devices
Autorzy:
Karpowicz, J.
Gryz, K.
Powiązania:
https://bibliotekanauki.pl/articles/90650.pdf
Data publikacji:
2006
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
MRI
occupational exposure
electromagnetic fields
exposure assessment
pole elektromagnetyczne
zagrożenia zdrowia
ocena ryzyka zawodowego
pole magnetyczne
narażenie zawodowe
Opis:
Health care staff who operate magnetic resonance imaging (MRI) devices are exposed to a static magnetic field of significant spatial heterogenity always produced by MRI magnets during the whole shift. They can also be exposed to pulses of a time-varying magnetic field (gradient field) present only during patients’ examinations. The level of the workers’ exposure depends both on the type of the magnet and on the ergonomic design of each MRI device. The paper presents methods used for measuring and assessing workers’ exposure. It also discusses the results of inspection measurements carried out next to approximately 20 MRI devices of approximately 0.2–2.0 T. The presented characteristic and overview of the variability of workers’ exposure to a variety of MRI devices supports the need for data on monitoring occupational exposure to MRI. International exposure assessment standards and guidelines (International Commission on Non-Ionizing Radiation Protection [ICNIRP], Institute of Electrical and Electronics Engineers [IEEE], American Conference of Governmental and Industrial Hygienists [ACGIH], European Commission directive), and those established in Poland are also compared.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2006, 12, 2; 155-167
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zdrowotne skutki ekspozycji na stałe pole magnetyczne – przegląd piśmiennictwa
Health effects of exposure to static magnetic field − a review of literature
Autorzy:
Zmyślony, Marek
Politański, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2162602.pdf
Data publikacji:
2019-02-28
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
zaburzenia metaboliczne
zaburzenia rozrodu
kancerogeny
układ nerwowy
stałe pole magnetyczne
układ krążenia
metabolic disorders
reproductive disorders
carcinogens
nervous system
static magnetic field
circulatory system
Opis:
Autorzy pracy omawiają skutki narażenia na stałe pole magnetyczne (SPM) na podstawie doniesień z piśmiennictwa. Systematycznym przeglądem zostały objęte badania zarówno z udziałem ludzi, jak i prowadzone na zwierzętach. Dokonano analizy różnych potencjalnych skutków działania SPM, np. kancerogennego, a także jego wpływu na zaburzenia rozrodu, oddziaływania na układ nerwowy, układ krążenia czy na zaburzenia metaboliczne. Opisano również możliwe efekty biofizyczne i biologiczne oddziaływania SPM. Med. Pr. 2019;70(1):107–120
The authors discuss the effects of static magnetic field (SMF) exposure based on reviewed literature reports. The systematic review covered both research carried out directly with people as well as studies with animals. A review was carried out in terms of various potential effects: carcinogenic effects, reproductive and metabolic disorders or the influence of SMF on the nervous and circulatory system. The possible biophysical and biological effects of the SMF were also described. Med Pr. 2019;70(1):107–20
Źródło:
Medycyna Pracy; 2019, 70, 1; 107-120
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techniczne aspekty ekspozycji na pole magnetyczne ekstremalnie niskich częstotliwości (ELF) w badaniach biomedycznych
Technical aspects of exposure to magnetic fields of extremely low frequencies (ELF) in biomedical research
Autorzy:
Bieńkowski, Paweł
Wyszkowska, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/2165380.pdf
Data publikacji:
2015-06-09
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
pole elektromagnetyczne
układ ekspozycyjny
metrologia pola elektromagnetycznego
solenoid
cewki Helmholtza
bioelektromagnetyzm
electromagnetic field
exposure system
electromagnetic field metrology
Helmholtz coils
bioelectromagnetism
Opis:
Wstęp Badania nad oddziaływaniem pola elektromagnetycznego na organizmy żywe są istotnym elementem badań biofizycznych. Są to badania interdyscyplinarne, łączące nierozerwalnie biologię i medycynę z techniką wytwarzania i pomiaru pól elektromagnetycznych. Celem pracy jest analiza układów ekspozycyjnych pola magnetycznego ekstremalnie niskich częstotliwości w badaniach biomedycznych oraz metod pomiarów parametrów pola. Materiał i metody Badaniom poddano 2 najpopularniejsze układy ekspozycyjne pola magnetycznego niskiej częstotliwości – solenoid i cewki Helmholtza. Przeprowadzono analizy teoretyczne i weryfikację pomiarową rozkładu pola w układach w celu oceny jednorodności pola. Zbadano również czynniki dodatkowe wpływające na ocenę biologicznych efektów ekspozycji – drgania i zmiany temperatury. Wyniki Na podstawie przeprowadzonych badań przedstawiono analizę porównawczą solenoidów i cewek Helmholtza jako układów ekspozycyjnych pola magnetycznego oraz sformułowano wnioski dotyczące opisu warunków ekspozycji na pole magnetyczne. Wnioski Autorzy podkreślają znaczenie świadomego doboru warunków ekspozycji i ich jednoznacznego opisu. Jest to podstawą odtworzenia warunków doświadczalnych oraz weryfikacji uzyskanych wyników. Med. Pr. 2015;66(2):185–197
Introduction Experiments on the electromagnetic field influence on organisms are an important part of biophysical studies. It is an interdisciplinary research spanning biology and medicine with the engineering in generation and measurement of electromagnetic fields. The aim of the study consists in the analysis of parameters estimations and measurements of extremely low frequency magnetic field (ELF MF) as well as exposure systems parameters in biomedical research. Material and Methods Experiments were performed on 2 most popular low magnetic field exposure systems: the solenoid and Helmholtz coils. A theoretical analysis and a measurement verification of the magnetic field distribution inside the systems were carried out to evaluate the homogeneity of the magnetic field. Additional factors, vibrations and temperature changes, affecting the assessment of the biological effects of magnetic field exposure were also examined. Results Based on the study results, a comparative analysis of solenoids and Helmholtz coils as the magnetic field exposure systems was presented. Proposals for the description of magnetic field exposure were also formulated. Conclusions The authors emphasize the importance of a conscious choice of exposure conditions and their explicit description. These are fundamental requirements for both the reproduction of experimental conditions and the verification of results. Med Pr 2015;66(2):185–197
Źródło:
Medycyna Pracy; 2015, 66, 2; 185-197
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekspozymetryczny profil narażenia zawodowego na pole magnetostatyczne przy tomografie rezonansu magnetycznego 1,5 T
Exposimetric profile of occupational exposure to static magnetic field of magnetic resonance scanner of 1.5 T
Autorzy:
Karpowicz, J.
Gryz, K.
Powiązania:
https://bibliotekanauki.pl/articles/261240.pdf
Data publikacji:
2010
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
tomograf
rezonans magnetyczny
narażenie zawodowe
ryzyko zawodowe
pole magnetostatyczne
badania ekspozymetryczne
MRI scanner
magnetic resonance imaging
occupational exposure
static magnetic field
exposimetric investigations
Opis:
W pracy scharakteryzowano ekspozymetryczne profile narażenia zawodowego techników i pielęgniarek na pole magnetostatyczne w czasie wykonywania badań diagnostycznych w tomografie rezonansu magnetycznego. Wyniki badań rzeczywistych warunków narażenia wykonanych ekspozymetrem hallotronowym w czasie rutynowych czynności przy badaniach pacjentów omówiono na przykładzie 16 czynności przy tomografie z magnesem 1,5 T. Czas narażenia na pole o indukcji przekraczającej 0,5 mT wynosi przy tych czynnościach 0,5-2,3 minuty, a czas narażenia przekraczającego 70 mT wynosi 0,0-0,3 minuty. Maksymalny poziom narażenia wynosi 16,8-126 mT.
In this paper, exposimetric profiles of occupational exposures of technicians and nurses to static magnetic fields during performing magnetic resonance imaging examinations, were characterized. Results of examination by hallotron exposimeter of the real exposure of the personnell performing 16 tasks in 1,5 T MRI scanner have been presented. Maximal exposure in the static magnetic field exceeding 0,5 mT is in the range 0,5-2,3 minutes and the exposure exceeding 70 mT is in the range 0,0-0,3 minutes. Maximum level of exposure is 16,8-126 mT.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2010, 16, 3; 261-264
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies