Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ijabor, B. O." wg kryterium: Wszystkie pola


Wyświetlanie 1-1 z 1
Tytuł:
Quality control test of conventional X-Ray systems in Delta State, South-South, Nigeria
Autorzy:
Ijabor, B. O.
Nzotta, C. C.
Omojola, A. D.
Powiązania:
https://bibliotekanauki.pl/articles/1193452.pdf
Data publikacji:
2021
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Digital Radiography (DR)
Focus to Image Distance (FID)
Half Value Layer (HVL)
Practical Peak Voltage (PPV)
Quality Assurance
Quality Control
Silicon Photodiode
Opis:
The quality assurance (QA) and quality control (QC) programmes of imaging equipment are key ingredients of a quality system. This study is aimed at measuring X-Ray machine parameters and comparing them with the American Association of Physicists in Medicine (AAPM) report No. 74. Also, this study made comparison with similar articles locally and internationally. The study was conducted in 12 X-Ray unit (A-L) located in Delta State. A MagicMax Universal Basic Unit was used alongside an XR Multidetector (silicon photodiode) to measure dose, dose rate, practical peak voltage (PPV), exposure time, current in milliampere (mA) and quantity (Q) in milliampere seconds (mAs). The XR Multidetector was positioned at 100 cm from the focus to image distance (FID) to make most measurements. Six (6) X-Ray units were above 20 years, accounting for 50% of the total X-Ray units used. 30% of X-Ray units > 20 years failed the QC test, which was 2.3 times higher than X-Ray units < 10 and 10-20 years respectively. On the average, 55% pass mark was achieved in the 12 X-Ray units across the state, while 26.11% of the test could not be done due to bad knobs and other challenges. Two (2) X-Ray units with an average age of 3 years, passed all the test. The study showed that many of the X-Ray units were old and certain machine parameters could not be assessed. The study also reveal that most X-Ray specifications manual were either misplaced or missing. Continuing QC programme is highly recommended in the studied areas.
Źródło:
World Scientific News; 2021, 157; 140-153
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies