Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Exoskeleton" wg kryterium: Wszystkie pola


Tytuł:
Light exoskeleton design with topology optimisation and FEM simulations for FFF technology
Autorzy:
Falkowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2141879.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
exoskeleton
rapid prototyping
rehabilitation robotics
topology optimisation
Opis:
Among past years interest in robot‐assisted rehabilitation arose significantly; thus, constructions such as exoskele‐ tons are involved in this process much more often. As pa‐ tient’s bio‐signals may be included in a control loop of these devices, they may be also used to support the mo‐ tion of extremities in an everyday life. Therefore, a field of control over them stays a popular research topic. For this reason, an exoskeleton described in a paper was de‐ signed. The most important aim of a project was to ena‐ ble all anatomical movements within ranges required for the lifting of an object while minimising a mass of the device. The following paper consist of a concept of an exoskeleton and description of FEM simulations and to‐ pology optimisation applied to decrease the amount of material needed. Moreover, as an exoskeleton was built with FFF 3‐D printing technology, created parts are mo‐ delled orthotopically based on nominal mechanical para‐ meters of filaments and directions of their beams. The de‐ sign is complemented with a short description of control with EMG signals and analysis of load on a user’s muscu‐ loskeletal system.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2021, 15, 2; 14-19
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza rozwiązań konstrukcyjnych egzoszkieletów palców ręki
Design solution of hand fingers exoskeleton
Autorzy:
Maćkowiak, P.
Ligaj, B.
Powiązania:
https://bibliotekanauki.pl/articles/95420.pdf
Data publikacji:
2015
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
egzoszkielet
ręka
palce
exoskeleton
hand
fingers
Opis:
W pracy przedstawiono istniejący stan wiedzy dotyczący egzoszkieletów palców ręki. Na podstawie analizy istniejących rozwiązań konstrukcyjnych scharakteryzowano egzoszkielety ręki. Celem pracy jest prezentacja własnej koncepcji urządzenia, będącej modyfikacją egzoszkieletu Shieldsa. Mimo dużego popytu na egzoszkielety ręki, obecne rozwiązania nie spełniają oczekiwań pacjentów i lekarzy. Ze względu na wiele stopni swobody, jakie ma ludzka ręka, konieczny jest kompromis pomiędzy uproszczeniem urządzenia a umożliwieniem wykonania chwytów podstawowych.
This article presents prezent knowledge of a hand exoskeleton. This paper describes characterization of hand exoskeletons based on an analysis of existing design solutions. The aim is to present own concept device, which is a modification of Shields exoskeleton. Despite the high demand for exoskeletons hand, current solutions do not meet the expectations of patients and physicians. The human hand has many degrees of freedom. Therefore, the need is to simplify the design of the device and provide the ability to perform basic hand grips at the same time.
Źródło:
Postępy w Inżynierii Mechanicznej; 2015, 6(3); 23-34
2300-3383
Pojawia się w:
Postępy w Inżynierii Mechanicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinematic analysis of the finger exoskeleton using MATLAB/Simulink
Autorzy:
Nasiłowski, K.
Awrejcewicz, J.
Lewandowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/307115.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
kinematyka
egzoszkielet
palec
MATLAB
Simulink
kinematic
finger
exoskeleton
Opis:
A paralyzed and not fully functional part of human body can be supported by the properly designed exoskeleton system with motoric abilities. It can help in rehabilitation, or movement of a disabled/paralyzed limb. Both suitably selected geometry and specialized software are studied applying the MATLAB environment. A finger exoskeleton was the base for MATLAB/Simulink model. Specialized software, such as MATLAB/Simulink give us an opportunity to optimize calculation reaching precise results, which help in next steps of design process. The calculations carried out yield information regarding movement relation between three functionally connected actuators and showed distance and velocity changes during the whole simulation time.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 3; 129-134
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and modeling of an exoskeleton torque sensor
Autorzy:
Herbin, P.
Powiązania:
https://bibliotekanauki.pl/articles/135222.pdf
Data publikacji:
2017
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
exoskeleton
torque sensor
FEM analysis
closed loop cable conduit system
strain gauge
wearable robots
Opis:
Controlling the upper limb with force feedback requires the continuous measurement of multiple values, so it is necessary to use a specific measuring system. The position of the joints and the torque produced by the drives are the basic feedbacks necessary for control. Measurement of the joint positions does not cause complications, while measurement of the driving torque is much more complex. This article describes the methods of implementing an exoskeleton drive system through a closed loop conduit system based on Bowden cables, and the integration of a torque sensor within the wheel of the exoskeleton. The integration of the sensor within a mechanical part of the construction of the exoskeleton is the main advantage of the developed sensor because it does not affect the dynamics of the exoskeleton. This article presents the process of designing, calibrating and validating the proposed link wheel torque sensor.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2017, 51 (123); 89-94
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of steady and non-steady gait of human-exoskeleton walking system
Autorzy:
Żur, K. K.
Powiązania:
https://bibliotekanauki.pl/articles/264542.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
identyfikacja
egzoszkielet
system sterowania
identification
steady gait
non-steady gait
exoskeleton
Opis:
In this paper a method of analysis of exoskeleton multistep locomotion was presented by using a computer with the preinstalled DChC program. The paper also presents a way to analytically calculate the “,motion indicator”, as well as the algorithm calculating its two derivatives. The algorithm developed by the author processes data collected from the investigation and then a program presents the obtained final results. Research into steady and non-steady multistep locomotion can be used to design two-legged robots of DAR type and exoskeleton control system.
Źródło:
International Journal of Applied Mechanics and Engineering; 2013, 18, 3; 923-933
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An exoskeleton arm optimal configuration determination using inverse kinematics and genetic algorithm
Autorzy:
Głowiński, Sebastian
Błażejewski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/306968.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
algorytm genetyczny
kinematyka odwrotna
egzoszkielet
ramię
arm exoskeleton
genetic algorithm
inverse kinematics
Opis:
This paper deals with the kinematic modelling of an arm exoskeleton used for human rehabilitation. The biomechanics of the arm was studied and the 9 Degrees of Freedom model was obtained. The particular (optimal) exoskeleton arm configuration is needed, depending on patient abilities and possibility or other users activity. Methods: The model of upper arm was obtained by using Denavit–Hartenberg notation. The exoskeleton human arm was modelled in MathWorks package. The multicriteria optimization procedure was formulated to plan the motion of trajectory. In order to find the problem solution, an artificial intelligence method was used. Results: The optimal solutions were found applying a genetic algorithm. Two variants of motion with and the visualization of the change of joints angles were shown. By the use of genetic algorithms, movement trajectory with the Pareto-optimum solutions has been presented as well. Creating a utopia point, it was possible to select only one solution from Pareto-optimum results. Conclusions: The obtained results demonstrate the efficiency of the proposed approach that can be utilized to analyse the kinematics and dynamics of exoskeletons using the dedicated design process. Genetic algorithm solution could be implemented to command actuators, especially in the case of multi-criteria problems. Moreover, the effectiveness of this method should be evaluated in the future by real experiments.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 1; 45-53
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Crane control system using exoskeleton based on programmable logic technology
Autorzy:
Ziętek, Ryszard
Woźniak, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/1819213.pdf
Data publikacji:
2020
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
master-slave control
field-programmable logic cascade regulation
mechatronic system
exoskeleton
crane
manipulator kinematics
Opis:
In this paper, a mini-crane control system using an exoskeleton based on programmable logic technology is presented. The first stage was to identify the parameters of the mini-crane and exoskeleton sub-assemblies. Then, individual crane and exoskeleton control subsystems were designed based on cascade regulation. The final stage was to connect these subsystems into the master-slave control system using the manipulator’s kinematics equations. Parallel processing was used to minimize delays in the control system. Analysis of the results showed that the difference between the set and measured crane position was small.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2020, 63 (135); 77-83
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gait pattern generator for control of a lower limb exoskeleton
Autorzy:
Grzelczyk, D.
Szymanowska, O.
Awrejcewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/127689.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
human gait
exoskeleton
central pattern generator
chód człowieka
egzoszkielet
centralny generator wzorca
Opis:
The aim of the study was to propose a relatively simple central pattern generator (CPG) model, which can be used to control a lower limb exoskeleton. The mentioned generator and the simulation model of the human gait were developed based on experimental observations of the healthy volunteer's gait recorded using a motion tracking system. In order to reproduce the correct movements of the exoskeleton segments, time series of angles in the joints corresponding to the hip and knee joints were calculated based on tracing the trajectories generated by the CPG and the inverse kinematic relations. The proposed model can be implemented to control the lower limb (extremity) exoskeleton and assist various types of gait abnormality in patients with different motor dysfunction by means of changing the parameters of the control system. The presented experimental data, the developed gait simulation model, and the results of numerical simulations can be treated as guidelines for further improvement of the proposed model and its application in the exoskeleton control system. Although the study is mainly focused on rehabilitation applications, the proposed model is general and can be used also for other purposes such as control of bipedal and multi-legged robots.
Źródło:
Vibrations in Physical Systems; 2018, 29; 1-10
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Egzoszkielet jako urządzenie wspomagające leczenie spastyczności
Exoskeleton as a medical device in supporting the spasticity rehabilitaion process
Autorzy:
Głowiński, S.
Powiązania:
https://bibliotekanauki.pl/articles/251695.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
egzoszkielet
spastyczność
rehabilitacja spastyczności
manipulator rehabilitacyjny
exoskeleton
spasticity
spasticity rehabilitation
rehabilitation manipulator
Opis:
Spastyczność jest poważnym zaburzeniem ruchowym objawiającym się wzmożonym napięciem mięśniowym lub sztywnością mięśni. Artykuł wprowadza w tematykę związaną ze zjawiskiem wzrostu napięcia mięśniowego występującym szczególnie u osób po udarach. Scharakteryzowano przyczyny, skale spastyczności, metody rehabilitacji i podano przykłady egzoszkieletów wykorzystywane w procesie rehabilitacji. Opracowano model matematyczny i komputerowy oraz przeprowadzono symulację testu Wartenberga wraz z doborem właściwych współczynników sztywności i tłumienia.
Paper discussed the the phenomenon of increased muscle tone in people with stroke. The cause, the spasticity scales and rehabilitation methods were presented. The exoskeleton in rehabilitation therapy for peoples after stroke were described. A mathematical and computer model was prepared and implemented for the pendulum knee Wartenberg test by using Matlab-Simulink package.
Źródło:
TTS Technika Transportu Szynowego; 2013, 10; 267-275, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinematyka egzoszkieletu kończyn dolnych o napędzie pneumatycznym podczas chodu i biegu
Kinematics of exoskeleton of lower limb
Autorzy:
Głowiński, S.
Powiązania:
https://bibliotekanauki.pl/articles/254149.pdf
Data publikacji:
2015
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
egzoszkielet
modelowanie
kończyny
napęd pneumatyczny
exoskeleton
modeling
limbs
pneumatic drive
Opis:
Artykuł wprowadza w problematykę związaną z modelowaniem egzoszkieletów. Na początku przeanalizowano pracę poszczególnych partii mięśni kończyny dolnej podczas chodu i biegu. Na tej podstawie zaproponowano model egzoszkieletu kończyn dolnych z napędem pneumatycznym. Do napędu wykorzystano sześć muskułów. Opracowano model kinematyczny z wyznaczeniem parametrów opisujących zależności kinematyczne występujące pomiędzy poszczególnymi elementami egzoszkieletu. Do wyznaczenia współrzędnych charakterystycznych punktów wykorzystano macierze kosinusów kierunkowych. Następnie określono długości poszczególnych muskułów w pozycji wyjściowej. Bazując na przeprowadzonych badaniach zmiany kątów poszczególnych stawów kończyny dolnej podczas chodu i biegu w jednym cyklu, określono zmianę długości każdego z muskułów. Następnie wyznaczono zmianę prędkości zmniejszania i zwiększania długości każdego z muskułów. Zaprezentowano wyniki w postaci przemieszczeń i prędkości. We wnioskach nakreślono cel następnych badań.
The article introduced the problems related to the exoskeleton modelling. A preliminary analysis work of individual muscle groups of the lower limb during gait. On this basis, the model of the exoskeleton of the lower limbs with pneumatic drive was proposed. As the actuator the six muscles were used. Kinematic model was developed with the appointment of kinematic parameters describing the dependence between various elements of the exoskeleton. To determine the coordinates of the landmarks of the direction cosine matrices used. Then the length of individual muscles in the starting position were determined. Based on studies of the angles change of the various joints of the lower limb during gait in one cycle set to change the length of each muscle. Then the determined change rate of decreasing and increasing the length of each muscle. In the final part of article the results of displacement and velocity were presented. In the conclusions the purpose of further research was described.
Źródło:
TTS Technika Transportu Szynowego; 2015, 12; 546-550, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies