Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Cryogenic" wg kryterium: Wszystkie pola


Tytuł:
Cryogenic carbonates and cryogenic speleothem damage in the Za Hájovnou Cave (Javoříčko Karst, Czech Republic)
Autorzy:
Žak, K.
Lipták, V.
Filippi, M.
Orvošová, M.
Hercman, H.
Matouškova, Š.
Powiązania:
https://bibliotekanauki.pl/articles/2060084.pdf
Data publikacji:
2018
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
cryogenic cave carbonates
speleothem damage
Javoříčko Karst
U-series dating
Opis:
A new locality of coarse-grained cryogenic cave carbonates has been found in the Za Hájovnou Cave in Javoříčko Karst in Central Moravia, Czech Republic. Crystals and crystal aggregates, usually up to 15 mm in size, form typical loose accumulations on the surface of large fallen limestone blocks and clays covering the bottoms of several cave chambers distant from the cave entrance. The cryogenic origin of the carbonates is supported by their mode of occurrence, specific crystal and aggregate morphology, and C and O stable isotope data. U-series dating of one sample of cryogenic carbonate (age 29.5 ±0.1 ka) indicated that a period of karst water freezing occurred in marine isotope stage (MIS) 3, within the Weichselian. The cave also hosts numerous examples of speleothem damage. As shown in this paper, some of these are clearly connected with freezing conditions and cave ice action.
Źródło:
Geological Quarterly; 2018, 62, 4; 829--839
1641-7291
Pojawia się w:
Geological Quarterly
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deep Cryogenic Treatment and Tempering at Different Temperatures of HS6-5-2 High Speed Steel
Autorzy:
Ciski, A.
Powiązania:
https://bibliotekanauki.pl/articles/352505.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
deep cryogenic treatment
high speed steel
tempering
hardness
microstructure
Opis:
The paper presents properties of HS6-5-2 high speed steel subjected to deep cryogenic treatment (DCT) and subsequent tempering at different temperatures. DCT process of HS6-5-2 steel leads to shifting of maximum hardness peak to the lower temperature and the reduction of the obtained maximum hardness by about 1 HRC. These changes in hardness may be due to the shifting of the stage of nucleation and growth of carbide phases to lower temperatures or the changes taking place in the matrix, connected with the additional transformation of the martensite proceeding during the isothermal martensitic transformation occurring at cryogenic temperatures and more extensively occurring precipitation processes, lowering the content of the carbon in the martensite, determining thereby its lower hardness.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 2; 929-934
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
FE analysis of current displacement phenomena in a squirrel cage motor working at cryogenic temperature
Autorzy:
Barański, M.
Powiązania:
https://bibliotekanauki.pl/articles/950666.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FE analysis of submerged induction motor
cryogenic temperature
coupled electromagnetic-thermal phenomena
current displacement
Opis:
The paper presents the special software for transient FE analysis of coupled electromagnetic-thermal problems in a squirrel cage submerged motor working at cryogenic temperature. A time-stepping finite element method and transients analysis of an induction motor has been applied. The non-linearity of the magnetic circuit, the movement of the rotor, skewed slots, and the influence of temperature on electric and thermal properties of the materials has been taken into account. Developed on the basis of presented algorithm a computer program used to analyze the phenomenon of current displacement in the rotor bars of high-voltage cage induction motor working in cryogenic conditions. The results of the simulations are presented.
Źródło:
Archives of Electrical Engineering; 2014, 63, 2; 139-147
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Constitutive model of plastic strain induced phenomena at cryogenic temperatures
Opis konstytutywny zjawisk wywołanych odkształceniami plastycznymi w temperaturach kriogenicznych
Autorzy:
Skoczeń, B.
Powiązania:
https://bibliotekanauki.pl/articles/280706.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
constitutive behaviour
yield condition
phase transformation
voids and inclusions
cryogenic temperature
Opis:
FCC metals and alloys are frequently used in cryogenic applications, nearly down to the temperature of absolute zero, because of their excellent physical and mechanical properties, including ductility. These materials, often characterized by the Low Stacking Fault Energy (LSFE), undergo at low temperatures three distinct phenomena: Dynamic Strain Ageing (DSA), plastic strain induced transformation from the parent phase to the secondary phase _ and evolution of micro-damage. As all three phenomena lead to irreversible degradation of lattice and can accelerate the process of material failure, a combined constitutive description appears to be fundamental for the correct analysis of structures applied at very low temperatures. The constitutive model presented in the paper takes into account all the three phenomena as well as the relevant thermodynamic background.
Materiały konstrukcyjne (metale lub ich stopy) o sieci krystalicznej regularnej ściennie centrowanej są często stosowane w temperaturach kriogenicznych (także w temperaturach bliskich absolutnego zera) z uwagi na bardzo dobre własności fizyczne i mechaniczne, a w szczególności wysoką plastyczność. Materiały te, charakteryzujące się z reguły niską energią błędu ułożenia, podlegają w niskich temperaturach trzem procesom: dynamicznemu starzeniu odkształceniowemu (które generuje nieciągłe płynięcie plastyczne), przemianie fazowej od struktury regularnej ściennie centrowanej do struktury regularnej przestrzennie centrowanej oraz ewolucji mikrouszkodzeń. Wszystkie te zjawiska prowadzą do nieodwracalnej degradacji sieci krystalicznej i szybszego zniszczenia materiału, dlatego budowa modelu konstytutywnego staje się nieodzownym elementem projektowania konstrukcji pracujących w temperaturach kriogenicznych. Model konstytutywny przedstawiony w artykule ujmuje wszystkie wyżej wymienione zjawiska, jak również termodynamikę procesów zacho- dzących w sieci krystalicznej w niskich temperaturach.
Źródło:
Journal of Theoretical and Applied Mechanics; 2008, 46, 4; 949-971
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Constitutive modelling and identification of parameters of 316L stainless steel at cryogenic temperatures
Autorzy:
Ryś, M.
Powiązania:
https://bibliotekanauki.pl/articles/386775.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
constitutive modelling
dissipative materials
phase transformation
cryogenic temperature
modelowanie konstytutywne
materiały rozpraszające
transformacja fazowa
temperatura kriogeniczna
Opis:
In this work, a macroscopic material model for simulation two distinct dissipative phenomena taking place in FCC metals and alloys at low temperatures: plasticity and phase transformation, is presented. Plastic yielding is the main phenomenon occurring when the yield stress is reached, resulting in nonlinear response of the material during loading. The phase transformation process leads to creation of two-phase continuum, where the parent phase coexists with the inclusions of secondary phase. An identification of the model parameters, based on uniaxial tension test at very low temperature, is also proposed.
Źródło:
Acta Mechanica et Automatica; 2014, 8, 3; 136-140
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laser cladding of Co-based metallic powder at cryogenic conditions
Autorzy:
Lisiecki, A.
Ślizak, D.
Kukofka, A.
Powiązania:
https://bibliotekanauki.pl/articles/367880.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
laser cladding
cobalt-based powder
cryogenic conditions
forced cooling
napawanie laserowe
proszek na bazie kobaltu
warunki kriogeniczne
chłodzenie
Opis:
Purpose: of this paper was demonstration a novel technique of laser cladding by experimentally composed Co-based metallic powder and forced cooling of the substrate by liquid nitrogen under cryogenic conditions, at the temperature -190°C, for producing clad layers with enhanced microstructure characteristic and properties. Design/methodology/approach: Technological tests of laser cladding were conducted by means of a high power fibre laser HPFL with maximum output power 3.0 kW, and six-axis robot. The experimental Co-based powder was composed for providing high abrasive wear resistance, high resistance for impact load, and also for corrosion resistance at elevated temperature. The unique and novel technique of forced cooling of the substrate was provided by immersing the specimens in the liquid nitrogen bath. The three coaxial nozzle head was designed and custom made to provide precise deposition of the powder delivered into the laser beam irradiation region. The scope of the study included tests of conventional laser cladding at free cooling in ambient air in a wide range of processing parameters, and also trials of laser cladding under cryogenic conditions. The test clad layers produced by conventional laser cladding and by the novel technique of laser powder deposition under cryogenic conditions were investigated and compared. Findings: The obtained results indicate that the novel technique of forced cooling the substrate by liquid nitrogen bath provides lower penetration depth, as well as low dilution of the clad, and also provides higher hardness of the clads. Additionally, it is possible shaping the geometry of the individual bead, providing high reinforcement and low width. Research limitations/implications: The presented results are based just on preliminary test of the novel technique of laser cladding under cryogenic conditions. Therefore, further study and detailed analyse of the influence of the cooling rate on the quality, microstructure, and properties of the deposited coatings are required. Practical implications: The study is focused on practical application of the novel technique for manufacturing of wear resistance coatings characterised with enhanced performance compared to conventional range of application of the laser cladding. Originality/value: Novel technique of laser cladding at forced cooling under cryogenic conditions was demonstrated. The powder used for cladding trials was experimentally composed (not commercially available). The experimental stand custom made was used with custom made powder feeding rate, and also with custom made coaxial nozzle head.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2019, 95, 1; 20-31
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected physico-mechanical characteristics of cryogenic and ambient ground turmeric
Autorzy:
Barnwal, P.
Mohite, A.M.
Singh, K.K.
Kumar, P.
Powiązania:
https://bibliotekanauki.pl/articles/25528.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
physical characteristics
mechanical characteristics
cryogenic grinding
ambient grinding
turmeric
Curcuma longa
packaging
handling
storage
Opis:
In this communication, selected physicomechanical characteristics of ground turmeric (cv. Prabha) were investigated for cryogenic and ambient grinding conditions of turmeric at different moisture contents (4, 6, 8 and 10% w.b.). A cryogenic grinder (Model: 100 UPZ, Hosokawa Alpine, Germany) and a micro pulverizer (hammer mill) were used for cryogenic and ambient grinding, respectively. The ground turmeric was graded in three grades viz. Gr-I, Gr-II and Gr-III with a sieve shaker using BSS Nos. 40, 85 and pan, respectively. Tap densities for cryogenic and ambient ground turmeric decreased from 678.7 (Gr-I) to 546.7 kgm-3 (Gr-III) and from 642.3 (Gr-I) to 468.6 kgm-3 (Gr-III), respectively, with the moisture increase. The angle of repose for cryogenic and ambient ground turmeric increased linearly from 26.85 (Gr-I) to 34.0° (Gr-III) and from 23.10 (Gr-I) to 28.06° (Gr-III), respectively with the increase in moisture content. The static coefficient of friction was the highest on plywood surface followed by mild steel sheet and galvanized iron sheet. The cryoground samples were found better in colour. Thermal conductivity of cryo-ground samples was higher than that of ambient ground samples. These physico-mechanical characteristics of cryogenic and ambient ground turmeric will be helpful for packaging, handling, and storage.
Źródło:
International Agrophysics; 2014, 28, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ecosystem services of the cryogenic environments: identification, evaluation and monetisation - A review
Autorzy:
Abakumov, Evgeny
Suleymanov, Azamat
Guzov, Yuriy
Titov, Victor
Vashuk, Angelina
Shestakova, Elena
Fedorova, Irina
Powiązania:
https://bibliotekanauki.pl/articles/2073732.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
amenability
Arctic
cryogenic environment
economic assessment
ecosystem services
monetisation
Opis:
The article discusses the valuation of ecosystem services in connection with the economic activity of the Russian Federation in the Arctic zone. It also considers the categories of ecosystem services in general and the assessment of ecosystem services in the Arctic in particular. The article also considers types of negative impacts on the Arctic ecosystems, their assessment, and investment risks existing in ecosystem services. It is shown that the application of the methodology and ecosystem services contributes to the adequate assessment and creation of a hierarchical classification of “usefulness” and “benefits” for society derived from the existence, use, and non-use of ecosystems. The concept of Arctic ecosystem services consists of three components: identification, monetisation, and ecological risk assessment. Identification, classification, and initial assessment, mainly at the qualitative level, allow us to determine and classify services for further improvement of life quality and regulation of socio-economic effects of environmental changes. Quantitative assessment is related to the identification of the degree of ecosystem service amenability. The example of the Arctic ecosystems shows that the possibility to assess and the accuracy of the assessment can be quite different and largely depends on the type of service. The analysis of possible ecosystem services and their relationship with the quality of life in the Russian Arctic indicates significant investment risks.
Źródło:
Journal of Water and Land Development; 2022, 52; 1--8
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie kriogenicznego komparatora prądowego do przekazywania jednostki miary rezystancji
Cryogenic current comparator in resistance unit transferring process
Autorzy:
Mosiądz, M.
Orzepowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/151384.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
komparator kriogeniczny
rezystor wzorcowy
jednostka rezystancji
cryogenic current comparator
standard resistor
resistance unit
CCC
Opis:
Przedstawiono zastosowanie kriogenicznego komparatora prądowego w procesie przekazywania jednostki miary rezystancji. Omówiono jego zasadę działania oraz możliwości pomiarowe w odniesieniu do innych metod transferu jednostki rezystancji.
Article presents role of cryogenic current comparator in the process of resistance unit transfer. Its working principles and measurement possibilities in the comparison to other resistance unit transfer methods are described.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9, 9; 19-22
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of cryogenic oxygen production unit with exhaust gas bleed for sewage sludge gasification and different oxygen purities
Autorzy:
Kaszuba, Maja
Ziółkowski, Paweł
Mikielewicz, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/27312208.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
thermodynamic analysis
oxy-combustion of syngas
BECCS
cryogenic air separation
penalty production
oxygen production
Opis:
The paper presents a thermodynamic analysis of the integration of a cryogenic air separation unit into a negative CO2 emission gas power plant. The power cycle utilizes sewage sludge as fuel so this system fits into the innovative idea of bioenergy with carbon capture and storage. A cryogenic air separation unit integrated with the power plant was simulated in professional plant engineering and thermodynamic process analysis software. Two cases of the thermodynamic cycle have been studied, namely with the exhaust bleed for fuel treatment and without it. The results of calculations indicate that the net efficiencies of the negative CO2 emission gas power plant reach 27.05% (combustion in 95.0% pure oxygen) and 24.57% (combustion in 99.5% pure oxygen) with the bleed. The efficiencies of the cycle without the bleed are 29.26% and 27.0% for combustion in 95.0% pure oxygen and 99.5% pure oxygen, respectively. For the mentioned cycle, the calculated energy penalty of oxygen production was 0.235 MWh/kgO2 for the lower purity value. However, for higher purity namely 99.5%, the energy penalty of oxygen production for the thermodynamic cycle including the bleed and excluding the bleed was indicated 0.346 and 0.347 MWh/kgO2, respectively. Additionally, the analysis of the oxygen purity impact on the carbon dioxide purity at the end of the carbon capture and storage installation shows that for the case with the bleed, CO2 purities are 93.8% and 97.6%, and excluding the bleed they are 93.8% and 97.8%, for the mentioned oxygen purities respectively. Insertion of the cryogenic oxygen production installation is required as the considered gas power plant uses oxy-combustion to facilitate carbon capture and storage method.
Źródło:
Archives of Thermodynamics; 2023, 44, 3; 63--81
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Epileptic burst measurement using microelectrodes equipped on a cryogenic microprobe for minimally invasive brain surgery of intractable epilepsy treatment
Autorzy:
Yamakawa, T.
Ishizuka, S.
Grigorievich, Z. L.
Suzuki, M.
Fujii, M.
Powiązania:
https://bibliotekanauki.pl/articles/385222.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
epilepsy
cryogenic surgery
minimally invasive
microelectrodes
CMOS IC
Opis:
A microprobing system, which has the functions of measuring the intracranial EEG(IC-EEG) and freezing brain tissue, is proposed for the minimally invasive brain cryogenic surgery of intractable epilepsy treatment. Two fi76 µm platinum electrodes were equipped on a fi0.8 mm cryogenic probe. Epileptic burst, which was evoked on a brain sample of a rat, was measured by the electrodes. The freezing function was confirmed with the experiments with sliced hippocampus samples of a rat.
Źródło:
Journal of Automation Mobile Robotics and Intelligent Systems; 2009, 3, 4; 76-79
1897-8649
2080-2145
Pojawia się w:
Journal of Automation Mobile Robotics and Intelligent Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Terapeutyczne oddziaływanie kriostymulacji ogólnoustrojowej
Autorzy:
Gmernicka, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2097366.pdf
Data publikacji:
2017-12-28
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
krioterapia
terapia zimnem
kriokomora ogólnoustrojowa
cryotherapy
cold therapy
cryogenic chamber
Opis:
Krioterapia ogólnoustrojowa polega na oddziaływaniu niskiej temperatury (poniżej -100 stopni Celsjusza) przez okres od 1,5 do 3 minut na cały organizm. Leczenie jest bezbolesne i ma na celu wyzwolenie reakcji fizjologicznych, które są korzystne z medycznego punktu widzenia. Zabieg ma działanie przeciwzapalne, zmniejsza bolesność mięśni, poprawia ich siłę, funkcję stawów oraz zwiększa krążenie krwi. Wywołuje również reakcję hormonalną, powodując wzrost ACTH, kortyzolu, beta-endorfin a u mężczyzn testosteronu. Krioterapia jest wykorzystywana nie tylko jako sposób leczenia, ale również jako część odnowy biologicznej oraz wspomaganie treningu sporto wego. Stosuje się ją profilaktycznie w celu poprawy komfortu fizycznego oraz zdrowia psychicznego. Aby osiągnąć pożądane efekty, konieczne jest zastosowanie po zabiegu w kriokomorze ogólnoustrojowej zestawu 20-minutowych ćwiczeń, wykonywanych pod nadzorem fizjoterapeuty.
Whole body cryotherapy (WBC) involves exposing individuals to extremely cold dry air (under -100 °C) for a period ranging from 1.5 to 3 minutes. The treatment is painless and is intended to produce and use physiological reaction, which is medically beneficial and effective in restoring normal body functions. Whole body cryotherapy provides various benefits such as: analgesic and anti-inflammatory effects, decreases muscle soreness, improves muscle strength and joint function, boosts blood circulation. It also causes a hormonal reaction, growth of ACTH, cortisol, beta-endorphin and testosterone. Cryotherapy is not only used as a way of treatment but also as a part of wellness and spa. WBC is used prophylactically to improve physical comfort and mental health. It is necessary to use kinesis immediately after cryotherapy to achieve its desirable affects. Kinesitherapy is a 20 minutes set of exercises performed on machines under the guidance of a physiotherapist. The purpose of kinesitherapy is the restoration of normal motion stereotypes, which will prevent overloads.
Źródło:
Health Promotion & Physical Activity; 2017, 1, 1; 19-22
2544-9117
Pojawia się w:
Health Promotion & Physical Activity
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conductors in Cryogenic Environment Used in Power Engineering
Przewodniki w środowisku kriogenicznym stosowane w energetyce
Autorzy:
Diodiu, Lucian
Matei, Aronel
Dragomir, Daniel Alexandru
Isaicu, Octavian
Powiązania:
https://bibliotekanauki.pl/articles/318919.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
środowisko kriogeniczne
azot
ładunek elektryczny
kriogeniczne kable
nadprzewodnictwo
cryogenic environment
nitrogen
electric charge
cryogen cables
superconductivity
Opis:
The tendency to increase the carrying capacity of the electric load in the supply networks can be done in two directions, namely: • the construction of several transmission and distribution lines linking the energy source to the consumer (current trend), having the effect of damaging the environment, or • limiting the construction of transport lines and, implicitly, the destruction of the environment by using technologies and materials capable of carrying a very large amount of electricity.
Tendencja do zwiększania obciążenia elektrycznego w sieciach zasilających może być realizowana w dwóch kierunkach, a mianowicie: budowa kilku linii przesyłowych i dystrybucyjnych łączących źródło energii z konsumentem (obecny trend), powodujących uszkodzenie środowiska, lub ograniczenie budowy linii transportowych i w efekcie ograniczenia zniszczenia środowiska poprzez zastosowanie technologii i urządzeń zdolnych do przenoszenia bardzo dużej ilości energii elektrycznej.
Źródło:
Inżynieria Mineralna; 2019, 21, 1; 69-71
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane zagadnienia projektowania linii kriogenicznej XATL1
Selected aspects of the XATL1 cryogenic line design
Autorzy:
Rusiński, E.
Iluk, A.
Malcher, K.
Chorowski, M.
Fydrych, J.
Powiązania:
https://bibliotekanauki.pl/articles/169611.pdf
Data publikacji:
2014
Wydawca:
Poltegor-Instytut Instytut Górnictwa Odkrywkowego
Tematy:
kriogeniczna linia helowa
XALT1
projektowanie
obliczenia wytrzymałościowe
cryogenic helium line
designing
strength calculations
Opis:
Przedstawiono wybrane problemy projektowania kriogenicznej linii helowej XATL1. Omówiono założenia do budowy modelu geometrycznego 3D instalacji kriogenicznej, przedstawiono przykładowe rozwiązania modelowe 3D i obiekty rzeczywiste. Przedstawiono również przykładowe wyniki obliczeń wytrzymałościowych. Analizę wytrzymałości rurociągu pracującego w ultra niskich temperaturach i współpracujących z nim urządzeń, przeprowadzono z wykorzystaniem MES oraz opracowanych modeli geometrycznych 3D projektowanych obiektów. Przy ustalaniu warunków brzegowych uwzględniono przypadki odpowiadające normalnej pracy projektowanej instalacji jak również przypadki odpowiadające stanom wyjątkowym jak próby ciśnieniowe lub awaria systemu. Na podstawie wyników obliczeń numerycznych dokonano weryfikacji założeń i opracowanych modeli geometrycznych 3D, które po wprowadzeniu niezbędnych poprawek, wykorzystano do sporządzenia kompletnej dokumentacji technicznej kriogenicznej linii XATL1.
The paper presents selected aspects of designing cryogenic helium lines XATL1. In the paper the design of a 3D geometric model of the cryogenic installation, the examples of the design solutions and real objects were presented. It also presents examples of the results of the strength calculations. The strength analysis of the transfer line was carried out using Finite Element Method. The analyzed load cases take into account the boundary conditions corresponding to the normal operation of the proposed installation as well as special cases of the pressure tests and system failure. Based on the results of numerical calculations, design assumption were verified and geometric models were modified to fulfil requirements of the AD 2000-Merkblatt code.
Źródło:
Górnictwo Odkrywkowe; 2014, 55, 4-5; 31-40
0043-2075
Pojawia się w:
Górnictwo Odkrywkowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technology of oxygen production in the membrane-cryogenic air separation system for a 600 MW oxy-type pulverized bed boiler
Autorzy:
Berdowska, S.
Skorek-Osikowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/240451.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kriogeniczny rozdział powietrza
membranowy separator
produkcja tlenu
cryogenic air separation
membrane air separation
oxygen production
Opis:
In this paper the results of the thermodynamic analysis of the oxy-combustion type pulverized bed boiler integrated with a hybrid, membrane-cryogenic oxygen separation installation are presented. For the calculations a 600 MW boiler with live steam parameters at 31.1 MPa /654.9[degrees]C and reheated steam at 6.15 MPa/672.4[degrees]C was chosen. In this paper the hybrid membrane-cryogenic technology as oxygen production unit for pulverized bed boiler was proposed. Such an installation consists of a membrane module and two cryogenic distillation columns. Models of these installations were built in the Aspen software. The energy intensity of the oxygen production process in the hybrid system was compared with the cryogenic technology. The analysis of the influence of membrane surface area on the energy intensity of the process of air separation as well as the influence of oxygen concentration at the inlet to the cryogenic installation on the energy intensity of a hybrid unit was performed.
Źródło:
Archives of Thermodynamics; 2012, 33, 3; 65-76
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies