Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "AC-AC converters" wg kryterium: Wszystkie pola


Tytuł:
Przekształtniki energoelektroniczne AC/DC/AC i AC/AC - układy topologiczne i sterowanie
AC/DC/AC and AC/AC converters - topological circuits and control
Autorzy:
Pieńkowski, K.
Knapczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/1375028.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
przekształtnik energoelektroniczny
przekształtniki AC/DC/AC
przekształtniki AC/AC
układ topologiczny
sterowanie
topologia
Opis:
Most variable-speed drive systems use an AC/DC/AC or AC/AC power conversion procedure. Currently, standard adjustable speed drives consist of a diode rectifier and a PWM voltage source inverter. Another alternative is controlled rectifier and a current source inverter. Today, due to the increased use of power electronics appliances and converters, the quality of power in the majority of the ac supply systems is reducing. Nonlinear currents drawn from the utility grid by those equipments imply mains voltage distortion and other problems resulting in harmonic pollution and electromagnetic interference implications. The paper presents a survey the most popular traditional and modern topologies of power electronics systems of converters used for adjustable speed AC motors. The topologies of front end rectifiers and motor inverters are presented. The special attention is paid for double-sided converters, multilevel converters, cascaded converters and dual inverter fed open-end stator winding of induction motor. The topologies of recently developed AC/AC and AC/DC/AC matrix converters are also discussed. The control systems and performance of presented converters is described.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 72; 247-252
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Complete power electronics converter for small wind turbine with asynchronous generator
Kompleksowy przekształtnik energoelektroniczny do małej turbiny wiatrowej z generatorem indukcyjnym
Autorzy:
Gajowik, T.
Możdżyński, K.
Malinowski, M.
Rafał, K.
Powiązania:
https://bibliotekanauki.pl/articles/1199253.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
wind energy integration
AC-AC converters
integracja energii wiatru
przekształtniki AC-AC
Opis:
W artykule przedstawiono kompleksowe rozwiązanie przeznaczone do automatyzacji oraz integracji z siecią elektroenergetyczną małej turbiny wiatrowej z generatorem indukcyjnym o regulowanej prędkości. Zaprezentowano strukturę systemu i omówiono szczegółowo przekształtnik energoelektroniczny AC-DC-AC wraz z obwodami pomocniczymi. Pokazano wyniki działania prototypowego układu o mocy 10 kW.
This paper presents a complete solution for automation and grid integration of a small wind turbine with variable speed asynchronous generator. Structure of a system is presented and AC-DC-AC power electronic converter with its auxiliary circuits is discussed in detail. Results of the 10 kW prototype system operation are illustrated.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2017, 3, 115; 71-76
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DC link condition monitoring method for two-level AC/DC/AC converters
Autorzy:
Lipnicki, P.
Lewandowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/1193395.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
DC link
condition monitoring
AC/DC
power electronics
converter
Opis:
Power electronics is one of the most important elements of today’s industry. Many of converters applications are being considered as critical for plant production process. Offering enhanced functionality in modern AC drives is a way to gain a competitive advantage in power converters market. One of the values to the customers comes from low cost condition monitoring of critical equipment and from optimized maintenance costs. DC bus is one of the elements of power converters. Although the designers pay a lot of attention when designing DC-link circuit, breakdowns and failures of the DC circuit components can still happen. Unfortunately this means that the whole converter must be shut down in emergency mode to be repaired. Nowadays, monitoring of the bus capacitor is becoming one of the desired features from customer side, as well as from the converter manufacturer. Proposed approach presents a method which assures the online evaluation of the equivalent series resistance (ESR) of a DC-link capacitor. The ESR increase trend is an important indicator of accelerated aging process or incoming failure of the capacitor. The important feature of the proposed condition monitoring method is that it does not require any additional sensors. For estimation purposes already installed sensors and other internal converter’s signals are used. Particularly the method employs the DC-link voltage measurement with the DC-link current reconstruction.
Źródło:
Power Electronics and Drives; 2017, 2, 37/1; 43-56
2451-0262
2543-4292
Pojawia się w:
Power Electronics and Drives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Steady-state modelling method for matrix-reactance frequency converter with boost topology
Autorzy:
Korotyeyev, I.Ye.
Zięba, B.
Powiązania:
https://bibliotekanauki.pl/articles/140872.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekształtnik AC/AC
matrycowo-reaktancyjny przemiennik częstotliwości
metoda Galerkina
równanie różniczkowe
AC/AC converters
matrix-reactance frequency converter
Galerkin's method
extension of differential equations
Opis:
This paper presents a method intended for calculation of steady-state processes in AC/AC three-phase converters that are described by nonstationary periodical differential equations. The method is based on the extension of nonstationary differential equations and the use of Galerkin's method. The results of calculations are presented in the form of a double Fourier series. As an example, a three-phase matrix-reactance frequency converter (MRFC) with boost topology is considered and the results of computation are compared with a numerical method.
Źródło:
Archives of Electrical Engineering; 2011, 60, 2; 137-148
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja warunków pracy transformatorów zasilających przekształtniki AC/DC/AC
Identifying operating conditions of transformers supplying AC/DC/AC converters
Autorzy:
Sikora, A.
Powiązania:
https://bibliotekanauki.pl/articles/1369365.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
transformatory
przekształtniki AC/DC/AC
warunki pracy
Opis:
The upshot of the ongoing development of energy-transforming systems is that devices used In power engineering meet with more difficult operating conditions when they co-operate directly with Power electronics circuits. High efficiency of power electronics circuits is achieved by switching power electronics elements on and off, often it is accomplished with PWM modulation. This approach causes emergence of very fast voltage gradients in the circuit, occurring at switching frequency. This may in turn adversely affect some elements of energy-transforming systems. We find such circuits in case of electric motors supplied from Power electronic converters, power electronics circuits for battery chargers, power electronics circuits used to trans form ecological energy obtained e.g. from solar batteries. We may cite here the example of inverters supplying induction motors; using inverters forced manufacturers to increase insulation level in these motors. Similar problem is encountered in case of using standard power engineering transformer in the circuit with Power electronics supply. The conducted tests of transformer oil show that after c. 5 years operation the oil had deeply degraded and this bears negative impact on insulation quality and significantly threatens transformer's life time.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2012, 4, 97; 25-28
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja wzorców transferowych AC/DC w Centralnym Wojskowym Ośrodku Metrologii
AC/DC transfer standards calibration at the Central Military Calibration Laboratory
Autorzy:
Piróg, P.
Górecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/208762.pdf
Data publikacji:
2017
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
wzorce transferowe AC/DC
różnica transferowa AC/DC
termiczne przetworniki wartości skutecznej
pomiar napięcia przemiennego
AC/DC converters
AC/DC difference
thermal voltage converters
TVCs
AC voltage measurement
Opis:
W artykule omówiono metodę kalibracji wzorca transferowego Fluke 5790A z użyciem transferowego wzorca odniesienia Fluke 792A, stosowaną w Centralnym Wojskowym Ośrodku Metrologii. Przedstawiono równanie pomiaru, budżet niepewności oraz ocenę wpływu wielkości wejściowych na niepewność pomiaru. Dokonano oceny spójności pomiarowej uzyskanych wyników kalibracji z wynikami ostatniej kalibracji w laboratorium Fluke.
The article discusses the method used at the Central Military Calibration Laboratory to calibrate Fluke 5790 AC/DC transfer standard with the reference transfer standard Fluke 792A. It presents the measurement equation and the uncertainty budget. The contribution of uncertainty components in the measurement uncertainty has been presented. The metrological traceability has been evaluated by comparing calibration results with the results in the last Fluke certificate of calibration.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2017, 66, 4; 203-213
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przetworniki termoelektryczne AC/DC jako wzorce napięcia przemiennego
AC/DC thermal transfer converters as AC voltage standards
Autorzy:
Barański, A.
Ratajczak, J.
Zawadzki, P.
Powiązania:
https://bibliotekanauki.pl/articles/153578.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przetworniki termoelektryczne AC/DC
napięcie przemienne
wartość skuteczna
AC/DC thermal transfer converter
AC voltage
true RMS
Opis:
Pomiary napięcia przemiennego w Głównym Urzędzie Miar są odnoszone do wzorców odtwarzanych przy napięciu stałym, wg zasady komparacji niejednoczesnej. W charakterze wzorca odniesienia przy napięciu przemiennym stosowane są zestawy przetworników termoelektrycznych. Struktura wzorca, dzięki różnym konfiguracjom, umożliwia pokrycie potrzeb wzorcowania tej wielkości do 1200 V i częstotliwości do 1 MHz. Omówiono istotę i źródła błędu komparacji, oraz sposób jego kompensacji. Schemat interkomparacji wzorca umożliwia odniesienie całej dziedziny do jednego przetwornika bazowego 1 VAC.
AC voltage measurements at the Central Office of Measures are being referenced to the standards restored at the DC voltage according to the principle of anti-coincidental comparison. As an AC voltage reference standard sets of thermoelectric converters are being used. Thanks to different configurations,the structure of the standard,enables covering the calibration needs of this quantity up to 1200 V at the frequency of up to 1 MHz. The nature and sources of comparison error were discussed as well as the way of its compensation. The schematic diagram of intercomparison enables referencing the whole field to one 1 VAC base converter.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 38-41
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Komparacja Termicznych Przetworników Wartości Skutecznej metodą dwukanałową - szacowanie niepewności przy przenoszeniu jednostki napięcia AC
Dual - channel comparison of AC-DC Thermal Voltage Converters (TVCs) - uncertainty analysis for AC voltage unit transfer
Autorzy:
Kaźmierczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/155822.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
napięcie AC
spójność pomiarowa
wzorcowanie
niepewność pomiaru
przetworniki termiczne wartości skutecznej
AC voltage
traceability
calibration
measurement uncertainty
thermal voltage converters
Opis:
W artykule przedstawiono rolę, jaką spełniają termiczne przetworniki wartości skutecznej (TVC) dla zapewnienia spójności pomiarowej w zakresie napięć AC niskich częstotliwości (do 1 MHz) w Głównym Urzędzie Miar (GUM). Przedstawiono metodę pomiarową komparacji dwukanałowej stosowaną w GUM do wzorcowania termicznych przetworników AC/DC wartości skutecznej napięcia elektrycznego przemiennego (AC). W drugiej części opisano procedurę szacowania niepewności dla tej metody i przedstawiono przykładowy budżet niepewności. Przedstawiono także przykładowe wyniki porównania wzorcowań przetwornika termicznego przeprowadzonych w GUM i w PTB (Niemcy) potwierdzające poprawność stosowanej metody komparacji.
The paper discusses thermal voltage converters (TVC) as reference standards for low AC voltages. The Central Office of Measures (GUM) in Warsaw, Poland, like many other NMIs, uses TVCs as reference standards for AC voltages. More precisely, a set of single-junction Holt Model 11 TVCs is used as a reference standard for AC voltages above 600 mV, while a semiconductor multi-range Fluke 792A TVC serves as a highest level working standard for these voltages and as a reference standard for the AC voltages below 600 mV. The precise traceability chart for AC voltages is shown in Fig. 2. The AC voltage unit is transferred at GUM using the dual - channel method for TVC comparison. This method is discussed and schematic of the measurement system is shown in Fig. 5. The consecutive equation describing an AC-DC difference of the TVC is discussed (equations (3) and (4)). The full analysis of the uncertainty budget is performed following the JCGM guide recommendations. Finally, two practical examples of the experimental results are given. In the first example a Fluke 792A TVC calibration at 10 V AC and 1 kHz is analysed and the measurement uncertainty is calculated (Tab. 1). In the second example the calibration results obtained at GUM and at PTB are compared for the same Fluke 792A TVC at 600 mV and frequencies ranging from 10 Hz to 1 MHz (Fig. 6).
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 11, 11; 1281-1284
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A fast-reversed DC voltage/current source to measure
Autorzy:
Kampik, M.
Tokarski, J.
Barwinek, W.
Kurczalski, M.
Powiązania:
https://bibliotekanauki.pl/articles/114134.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
AC voltage standards
thermal converters
AC-DC transfer difference
Opis:
The paper presents a fast-reversed DC voltage/current source (FRDC) used for determination of the frequency-independent AC-DC transfer difference of thermal voltage converters. It contains also results of experiments and measurements.
Źródło:
Measurement Automation Monitoring; 2016, 62, 1; 2-6
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wzorce napięcia przemiennego o liczalnej różnicy transferowej w paśmie częstotliwości
AC voltage standards with calculable AC-DC transfer difference in frequency range from 10 kHz to 1 MHz
Autorzy:
Kampik, M.
Grzenik, M.
Musioł, K.
Powiązania:
https://bibliotekanauki.pl/articles/972213.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorce napięcia przemiennego
transfer AC-DC
termiczne przetworniki wartości skutecznej
AC voltage standard
AC-DC transfer
thermal voltage converters
Opis:
W artykule zaprezentowano konstrukcję oraz podstawowe parametry metrologiczne trzech wzorców napięcia przemiennego o liczalnej różnicy transferowej w paśmie częstotliwości 10 kHz - 1 MHz. Artykuł zawiera między innymi obliczone w oparciu o model matematyczny wartości różnic transferowych wzorców oraz niepewności ich wyznaczenia. Ponadto w pracy opisano schemat komparacji wzorców oraz teoretyczne wyniki tej komparacji.
The paper presents construction and basic metrological parameters of AC voltage standards with calculable AC-DC transfer difference in the frequency range from 10 kHz to 1 MHz. Three standards cover the AC voltage range from approximately 0.7 to 6 V. Each standard is composed of a series range resistor and a single junction thermal converter (SJTC). The range resistor is made from thin resistive wire and mounted, together with the SJTC, in a coaxial copper-brass enclosure shown in Fig.1. The construction of each standard is similar to those presented in [1]. The nominal values of construction and material parameters, common for all the three standards, are listed in Table 2. The AC-DC transfer difference, given by Eq.3, was calculated using the theoretical model presented in [2], however in the calculations presented in this paper the influence of the Tee-connector was included. In Section 4 the standard uncertainty of the calculated AC-DC differences is estimated according to [3]. The relation between the calculated AC-DC differences and the frequencies of all the three standards, together with the estimated uncertainties are given in Tables 3 - 5. In Section 5 a method for verification of the calculated AC-DC transfer differences is described: the 1.5 V standard will be directly compared with the 3 V standard, and the 3 V standard will be compared with the 6 V standard. The result of such comparisons - the differences of the AC-DC transfer differences of the compared standards were theoretically calculated. They are listed in Table 6.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 418-421
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the interphase reactor on the operation of 12-pulse AC/DC thyristor rectifier
Wpływ dławika kojarzącego na pracę tyrystorowego prostownika 12-pulsowego
Autorzy:
Stawczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/402479.pdf
Data publikacji:
2013
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
AC/DC converter
power quality
interphase reactor
line currents
controlled rectifiers
multi-pulse AC/DC converters
przekształtnik AC/DC
jakość energii
dławik kojarzący
prądy liniowe
prostowniki sterowane
multipulsowe przekształtniki AC/DC
Opis:
The parallel connection of 6-pulse componnent bridges in the 12-pulse rectifier requires associating inductors. The article presents an analysis of the influence on interphase reactor on the operation of 12-pulse AC/DC thyristor converter. A very important issue is to set the limit value of the load current, at a given firing angle of the thyristors which is working properly.
Źródło:
Structure and Environment; 2013, 5, 3; 41-44
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dedicated system for design, analysis and optimization of AC-DC converters
Autorzy:
Piasecki, S.
Szmurlo, R.
Rabkowski, J.
Jasiński, M.
Powiązania:
https://bibliotekanauki.pl/articles/201404.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AC-DC converter
multi-objective optimization
design methodology
distributed generation systems
konwerter AC-DC
optymalizacja wielokryterialna
metodologia projektowania
generacja rozproszona
Opis:
This paper presents an originally-developed system for design and optimization of AC-DC converters dedicated in particular to operation in distributed generation systems. The proposed procedure is based on a multi-objective discrete optimization and expert knowledge of electrical engineering, especially power electronics. The required accuracy of calculations is obtained by using the database with real components, while the parameters applied in calculations are based on parameters provided by the manufacturer. The paper presents the foundations and basic system properties, the design and optimization process, and selected optimization results, obtained with a fully functional prototype of the design and optimization system (DaOS).
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2016, 64, 4; 897-905
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generacja i propagacja zaburzeń elektromagnetycznych w nieizolowanych przetwornicach AC/DC małej mocy
Generation and propagation of electromagnetic disturbances in non-insulated AC/DC low power converters
Autorzy:
Sabat, W.
Kuryło, K.
Klepacki, D.
Kamuda, K.
Powiązania:
https://bibliotekanauki.pl/articles/269135.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
nieizolowana przetwornica
AC/DC
kompatybilność elektromagnetyczna
zaburzenia przewodzone
nonisolated AC/DC power converter
electromagnetic compatibility
conducted disturbances
Opis:
W opracowaniu zostały zaprezentowane wyniki prac doświadczalnych jakie zostały przeprowadzone dla modelowej nieizolowanej przetwornicy AC/DC małej mocy. W ramach prac doświadczalnych zbadano jakie czynnik mają wpływ na poziom i charakter generowanych zaburzeń przewodzonych. Na przykładzie modelowej przetwornicy pokazano jak generowane są zaburzenia, jak są propagowane w jej układzie oraz jak stopień i charakter jej obciążenia wpływa na poziom generowanych zaburzeń. Docelowo układ zasilacza ze sterownikiem VIPer16L został wykorzystany w układzie regulatora obrotów silnika w aplikacji AGD.
The paper presents the results of the experimental work that was carried out for the model non-insulated AC / DC low power converters. They are used to supply the components of the electrical installation, controls, automation systems in building (sensors of lights, smoke, etc.), remote control systems, time programmers, consumer appliances and lighting components etc. The manufacturers offer now the integrated drivers for the construction of non-isolated converters with power up to several watts. As part of the experimental work the factors which have an influence on the level and nature of conducted disturbances propagation were examined. The example of a model converter shows how the disturbances are generated and propagated in circuit of non-isolated power supply and how the degree and nature of its load affects the level of generated conducted disturbances. It shows how the load condition of the power supply influenced on the level of generated conducted disturbances. Finally, the VIPer16L power supply application has been used in the application of the engine speed regulator for household appliances.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 56; 89-97
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precision Calculations of the Characteristic Impedance of Complex Coaxial Waveguides Used in Wideband Thermal Converters of AC Voltage and Current
Autorzy:
Kubiczek, Krzysztof
Kampik, Marian
Powiązania:
https://bibliotekanauki.pl/articles/2124756.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AC voltage standard
current shunt
characteristic impedance
multilayer cylindrical conductor
FEM simulation
modified Bessel functions
numerical stability
calorimetric thermal voltage converter
ac-dc transfer difference
Opis:
The article presents precision and numerically stable method of calculation of the characteristic impedance of cylindrical multilayer waveguides used in high-precision wideband measuring instruments and standards, especially calculable thermal converters of AC voltage and precision wideband current shunts. Most of currently existing algorithms of characteristic impedance calculation of such waveguides are based upon approximations. Unfortunately, application of such methods is limited to waveguides composed of a specific, usually low number of layers. The accuracy of approximation methods as well as the number of layers is sometimes not sufficient, especially when the coaxial waveguide is a part of precision measurement equipment. The article presents the numerically stable matrix analytical formula using exponentially scaled modified Bessel functions to compute characteristic impedance and its components of the cylindrical coaxial multilayer waveguides. Results obtained with the developed method were compared with results of simulations made using the Finite Element Method (FEM) software simulations. Very good agreement between results of those two methods were achieved.
Źródło:
International Journal of Electronics and Telecommunications; 2022, 68, 3; 527--533
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Classical control of the neutral point in 4-wire 3-phase DC-AC converters
Autorzy:
Zhong, Q. C.
Hobson, L.
Jayne, M. G.
Powiązania:
https://bibliotekanauki.pl/articles/262721.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
DC/AC power converter
neutral leg
3-phase 4-wire systems
split DC link
Opis:
In this paper, the classical control techniques are applied to the neutral point in a 3-phase 4-wire DC-AC power converter. The converter is intended to be connected to 3-phase 4-wire loads and/or the power grid. The neutral point can be steadily regulated by a simple controller, involving in voltage and current feedback, even when the three-phase converter system (mostly, the load) is extremely unbalanced. The achievable performance is analyzed quantitatively and the parameters of the neutral leg are determined. Simulations show that the proposed theory is very effective.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 2; 73-81
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies