Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę ""Majewski, Tomasz"" wg kryterium: Wszystkie pola


Tytuł:
Mechanical Response of Additively Manufactured Composite Joints
Badania odpowiedzi mechanicznej połączeń kompozytowych wykonanych technikami przyrostowymi
Autorzy:
Rajkowski, Kamil
Majewski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/27314953.pdf
Data publikacji:
2023
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
mechanical engineering
strength testing
impact test
drop hammer
3D printing
inżynieria mechaniczna
badania wytrzymałościowe
próba udarnościowa
młot spadowy
druk 3D
Opis:
This paper aims to assess the quality of composite joints made with the Fused Filament Fabrication (FFF) additive manufacturing technique through strength tests. The first part of this paper details the design of different test sample versions with standardised geometry and the methods of joining plastics by application of 3D printing. The details cover the test apparatus used in the research, sample preparation methodology, as well as tensile and impact testing methodology. The test sample versions were selected according to the test types to have the results fully reproduce the mechanical response of the composite materials to the input forces. The second part of this paper analysis of the test results, presenting the fabrication accuracy of the test samples and their mechanical response recorded during the tests. Five test specimens of each version were produced to enable statistical analysis of the test results, which was indispensable for a reliable data analysis. The tests made it possible to determine how the proposed joints of plastic materials responded to the input forces, the maximum transmitted force limit, and the flaws of each version’s design. The test results made it possible to adapt the suggested solutions in the design engineering of programmable energy-absorbing structures.
W artykule zostały przedstawione oraz przeanalizowane wyniki badań jakości połączeń kompozytowych wykonanych techniką przyrostową Fused Filament Fabrication (FFF). W pierwszej części artykułu znajdują się informację dotyczące projektu różnych wariantów próbek o znormalizowanej geometrii oraz sposobów połączenia ze sobą tworzyw sztucznych z wykorzystaniem druku 3D. Dodatkowo opisane zostały aparatura, jak i metodyka zastosowana do wykonania próbek oraz przeprowadzenia badań wytrzymałościowych i udarnościowych. Warianty próbek zostały dobrane w zależności od wykonywanych badań w taki sposób, żeby uzyskane wyniki w pełni odzwierciedlały odpowiedź mechaniczną kompozytów na zadane wymuszenie. W drugiej części zostały zebrane i przeanalizowane wyniki zarówno przedstawiające dokładność wykonania próbek, jak i ich odpowiedź mechaniczną zarejestrowaną podczas testów. W ramach każdego wariantu zostało wykonanych pięć próbek umożliwiających analizę statystyczną wyników, niezbędną do rzetelnej analizy danych. Badania pozwoliły ustalić w jaki sposób zaproponowane połączenia tworzyw sztucznych reagują na zadane wymuszenia, jaka jest maksymalna siła, którą mogą przenieść oraz jakie wady mają poszczególne konstrukcje. Dzięki uzyskanym wynikom możliwa jest adaptacja zaproponowanych rozwiązań w projektowaniu programowalnych struktur energochłonnych.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2023, 14, 3 (53); 59--76
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of a historic sacral building on an example Basilica St. Nicholas in Gdańsk
Autorzy:
Majewski, Tomasz
Niedostatkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/24201300.pdf
Data publikacji:
2023
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
object monitoring
construction diagnostics
monument
sacral building
failure of brick building
failure of monument
Basilica of St. Nicholas in Gdańsk
monitorowanie obiektów
diagnostyka konstrukcji
pomnik
budynek sakralny
awaria budynku ceglanego
awaria pomnika
Bazylika św. Mikołaja w Gdańsku
Opis:
The paper describes the case of monitoring the technical condition of a historic sacral building after a failure and during renovation works. In order to monitor the condition of the building, safely conduct diagnostic work, identify the causes of failures and safely carry out renovation works, a detailed Facility Monitoring Program has been developed, which has been implemented, is operational and is a source of valuable data used to assess the current condition of the facility.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2023, 3; 30--42
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Renovation works in buildings in the area of former defensive fortifications
Autorzy:
Niedostatkiewicz, Maciej
Majewski, Tomasz
Baryłka, Adam
Powiązania:
https://bibliotekanauki.pl/articles/2201992.pdf
Data publikacji:
2023
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
renovation
monument
reconstruction
strengthening of structural elements
pomnik
rekonstrukcja
wzmocnienie elementów konstrukcyjnych
Opis:
The paper presents the Complex of Buildings which was created in Gdańsk as a result of the reconstruction and development of the remains of the defensive fortifications of Redita Napoleońska. Some of the buildings of the Building Complex, after many years of operation, were in an emergency condition and required urgent renovation and repair work. The paper contains a detailed analysis of the technical condition of individual buildings of the Building Complex and analyzes the impact of the current use and the lack of regular periodic repairs on the technical efficiency of these facilities. Conceptual solutions in the field of renovation and repair works were also presented, the purpose of which was to bring the objects in question to the proper technical condition.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2023, 1; 1--21
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Settlement of a historic building due to seepage-induced soil deformation
Osiadanie zabytkowego budynku w wyniku deformacji filtracyjnych gruntu
Autorzy:
Popielski, Paweł
Bednarz, Bartosz
Majewski, Tomasz
Niedostatkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/27312076.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
podłoże budowlane
filtracja
grunt
osiadanie budynku
deformacja filtracyjna
budynek zabytkowy
building subsoil
seepage
ground
building settlement
seepage-induced deformation
historic building
Opis:
The research paper reviews issues associated with the impact of groundwater flow on soil characteristics and parameters, hence, the entire structure of a building set on it. Water seepage through the ground, building subsoil or structural elements of buildings made of soil affects the soil skeleton and may lead to changes in the arrangement of individual grains relative to each other, i.e., a modified soil structure. Soil solid phase (soil skeleton) deformations resulting from seepage forces are called seepage-induced deformations. The article characterizes typical seepage-induced deformations and specifies a criterion defining the beginning of the phenomenon. The case study involved using data on cracks and deformations in a historic building, as well as water seepage in its subsoil. Seepage was analysed, and zones where the seepage process initiation criterion was exceeded, were determined based on subsoil water level monitoring data. The determined zones coincide with the location of building cracks and scratches and confirm the possible cause behind building damage.
W artykule dokonano przeglądu zagadnień związanych z wpływem przepływu wód gruntowych na właściwości i parametry gruntu, a tym samym na całą konstrukcję posadowionego na nim budynku. Filtracja wody przez grunt, podłoże budowlane lub elementy konstrukcyjne budowli wykonanych z gruntu oddziałuje na szkielet gruntu i może prowadzić do zmian w układzie poszczególnych ziaren względem siebie, czyli do modyfikacji jego struktury. Odkształcenia szkieletu gruntowego wynikające z działania sił filtracji nazywane są deformacjami filtracyjnymi. W artykule scharakteryzowano typowe deformacje wywołane filtracją wody w gruncie oraz podano kryterium określające moment pojawiania się danego zjawiska. W studium przypadku wykorzystano dane dotyczące spękań i odkształceń w zabytkowym budynku oraz filtracji wody w jego podłożu. Na podstawie danych z monitoringu poziomu wody gruntowej przeanalizowano przepływ wód podziemnych i wyznaczono strefy, w których przekroczone zostało kryterium inicjacji procesu sufozji. Wyznaczone strefy pokrywają się z lokalizacją pęknięć i zarysowań budynku i potwierdzają możliwą przyczynę jego uszkodzenia.
Źródło:
Archives of Civil Engineering; 2023, 69, 2; 65--82
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Analysis of the Demolition of the Cereal Elevator Building within a Conservation Protection Zone: Considerations of Technical, Functional-Utility, and Economic Factors
Autorzy:
Niedostatkiewicz, Maciej
Majewski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/24202376.pdf
Data publikacji:
2022
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
renovation
conservation protection
grain elevator
demolition
technical condition assessment
renowacja
ochrona konserwatorska
elewator zbożowy
rozbiórka
ocena stanu technicznego
Opis:
The article presents a description of the technical condition of the Grain Elevator building situated on the port quay, which after many years of operation has been decommissioned. The immediate reason for the cessation of operation was the change in the use profile of the port quay, which caused the handling of other goods at the quay than the bulk materials originally stored in Elewator Zbożowy. The work contains a detailed analysis of the technical condition of the building, also taking into account the functional and utility aspect as well as the economics of renovation works. The article showed that despite the location of the building in the conservation protection zone, the optimal solution was the demolition of Grain Elevator and its reconstruction of a new warehouse facility with parameters adapted to the current needs and target handling capacity of the port quay.
Źródło:
Modern Engineering; 2022, 3; 1--10
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bunker demolition located in a conservation protection zone in the light of technical, national defense, functional-utility and economic conditions
Autorzy:
Niedostatkiewicz, Maciej
Majewski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2172412.pdf
Data publikacji:
2022
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
renovation
conservation protection
bunker
demolition
assessment of technical condition
renowacja
ochrona konserwatorska
bunkier
rozbiórka
ocena stanu technicznego
Opis:
The paper presents a description of the technical condition of the Bunker building located at the port quay, which has been out of use for several decades. The direct reason for the cessation of exploitation was the deletion of Bunker from the Civil Defense records. The paper contains a detailed analysis of the Bunker's technical condition, also taking into account the national defense, functional and utility aspects and the issues of economics of carrying out renovation works. The paper shows that despite the location of the Bunker in the conservation protection zone, the optimal solution was its demolition and the final use of the area where the Bunker was located as a place for the construction of warehouse buildings with parameters adapted to the current needs and target transshipment capabilities of the port quay.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2022, 4; 1--11
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Demolition of the cereal elevator building located in the conservation protection zone in the aspect of technical, functional-utility and economic conditions
Autorzy:
Niedostatkiewicz, Maciej
Majewski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2172401.pdf
Data publikacji:
2022
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
renovation
conservation protection
grain elevator
demolition
technical condition assessment
renowacja
ochrona konserwatorska
elewator zbożowy
rozbiórka
ocena stanu technicznego
Opis:
The article presents a description of the technical condition of the Grain Elevator building situated on the port quay, which after many years of operation has been decommissioned. The immediate reason for the cessation of operation was the change in the use profile of the port quay, which caused the handling of other goods at the quay than the bulk materials originally stored in Elewator Zbożowy. The work contains a detailed analysis of the technical condition of the building, also taking into account the functional and utility aspect as well as the economics of renovation works. The article showed that despite the location of the building in the conservation protection zone, the optimal solution was the demolition of Grain Elevator and its reconstruction of a new warehouse facility with parameters adapted to the current needs and target handling capacity of the port quay.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2022, 3; 55--65
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka cienkościennych żelbetowych sklepień kolebkowych w budynku zabytkowym. Część I
Diagnostics of thin-walled reinforced concrete barrel vaults in a historic building
Autorzy:
Majewski, Tomasz
Niedostatkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/2202694.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
sklepienie kolebkowe
sklepienie Rabitza
diagnostyka
obiekt zabytkowy
badanie bezinwazyjne
powłoka żelbetowa
sklepienie walcowe
Dworzec Główny w Gdańsku
Gdańsk
hala dworcowa
barrel vault
Rabitz vault
diagnostics
historic building
non-invasive research
reinforced concrete shell
cylindrical vault
Gdańsk Central Station
station hall
railway station
Opis:
W artykule przedstawiono opis oraz wyniki oceny stanu technicznego konstrukcji przekrycia Hali Głównej Dworca Kolejowego Gdańsk Główny. Ze względu na prowadzone prace związane z remontem kapitalnym Dworca Głównego PKP w Gdańsku zaistniała konieczność przeprowadzenia rewitalizacji poddasza Hali Głównej, obejmująca między innymi jego termomodernizację (ocieplenie wysklepek) oraz zabezpieczenie elementów wiązarów dachowych przed pożarem. W celu oceny stanu technicznego sklepień oraz poziomu wytężenia elementów konstrukcyjnych dachu wykonano szereg badań i pomiarów, w tym skanowanie zbrojenia żelbetowych sklepień kolebkowych z zastosowaniem detektora ferromagnetycznego w celu oceny średnicy, rozstawu i grubości otulenia prętów zbrojenia łupin oraz badania ultradźwiękowe betonu przy użyciu betonoskopu w celu oszacowania wytrzymałości betonu na ściskanie, jego jednorodności oraz grubości płaszcza powłoki. W artykule przedstawiono wyniki wykonanych badań i analiz, które pozwoliły na zaproponowanie sposobu naprawy cienkościennych sklepień żelbetowych typu Rabitza.
The article presents a description and results of the assessment of the technical condition of the roof covering of the Main Hall of the Gdańsk Główny Railway Station. Due to the ongoing works related to the major renovation of the Main Railway Station in Gdańsk, it was necessary to revitalize the attic of the Main Hall, including, among others, its thermal modernization (insulation of the vaults) and securing the roof truss elements against fire. In order to assess the technical condition of the vaults and the level of effort of the roof structural elements, a number of tests and measurements were carried out, including scanning the reinforcement of reinforced concrete barrel vaults with the use of a ferromagnetic detector to assess the diameter, spacing and cover thickness of the shell reinforcement bars, and ultrasonic testing of concrete using a concrete scope to estimating the compressive strength of concrete, its homogeneity and the thickness of the coating. The article presents the results of the tests and analyzes carried out, which allowed to propose a method of repairing thin-walled reinforced concrete vaults of the Rabitz type.
Źródło:
Przegląd Budowlany; 2022, 93, 11-12; 111--115
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dilatometry of Steel for the Production of 5.56 mm Calibre Rifle Barrels
Badania dylatometryczne stali do produkcji luf 5,56 mm
Autorzy:
Dębski, Andrzej
Majewski, Tomasz
Paszkowski, Robert
Powiązania:
https://bibliotekanauki.pl/articles/2073831.pdf
Data publikacji:
2021
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
mechanical engineering
firearm barrels
dilatometry
inżynieria mechaniczna
lufy
badania dylatometryczne
Opis:
During high rates of fire, the bore of the firearm barrel is exposed to high temperatures. This exposure induces structural changes in the barrel material, which is especially significant for the substrate of the galvanic chrome plating. The alloy steel grades used currently for firearm barrels, when exposed to heating above the ferrite stability limits, develop a phase transition with a discrete negative change in the material volume, which results in typical crazing in the bore. This effect is destructive to the galvanic chrome plating, leading to a loss of adhesion, which reduces the ballistic performance of the firearm, especially its muzzle velocity. This can be prevented by manufacturing barrels from steels having a limited range of phase transitions. The primary method for determining the presence of distinct volume changes in steel due to phase transition is dilatometry over a wide temperature range, which includes the interval within which the barrel bore is heated. This paper presents the dilatometry results for four steel grades, which included a steel grade currently used for firearm barrels, and an analysis of the effects of phase transition on the degradation of the barrel bore.
Podczas intensywnego strzelania przewód lufy broni strzeleckiej jest narażony na działanie wysokiej temperatury. Powoduje to przemiany strukturalne szczególnie intensywne w podłożu pod warstwą chromu galwanicznego. Stosowane obecnie stale stopowe podczas nagrzewania do temperatur powyżej stabilności ferrytu charakteryzują się przejściem fazowym ze skokową ujemną zmianą objętości materiału, która powoduje powstanie w przewodzie lufy typowej siatki spękań. Ma to destrukcyjny wpływ na powłokę chromu galwanicznego, skutkuje utratą jej przyczepności a co za tym idzie pogorszeniem parametrów balistycznych broni; szczególnie prędkości wylotowej. Można temu przeciwdziałać wprowadzając do produkcji luf stale o ograniczonym zakresie przemian fazowych. Podstawowym sposobem ustalenia czy w stali występuje wyraźna zmiana objętości związana z przemianą fazową są badania dylatometryczne w szerokim zakresie temperatur obejmujący zakres, do którego nagrzewa się przewód lufy. W artykule przedstawiono wyniki badań dylatometrycznych czterech stali, w tym stosowanej obecnie i przeanalizowano wpływ przemian fazowych na degradację przewodu lufy.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2021, 12, 4 (46); 57--68
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przestrzeń uwagi a współczesna inżynieria epistemiczna. O przyszłości uniwersytetu
Realm of attention and contemporary epistemic engineering. On the future of university
Autorzy:
Majewski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2034024.pdf
Data publikacji:
2021-12-08
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
uniwersytet
antyrelatywizm poznawczy
spory aksjologiczne
kształcenie kompetencji poznawczych
reforma szkolnictwa wyższego
naukometria
University
cognitive anti-relativism
axiological disputes
training cognitive competences
reform of higher education
scienceometry
Opis:
Artykuł stanowi głos w sprawie współczesnej kondycji uniwersytetu oraz wprowadzanej od 2018 reformy szkolnictwa wyższego (tzw. reformy 2.0). Narzucana przez reformę kultura zarządzania, nakierowana na „naukową produktywność” i bibliometrię, pozostaje w konflikcie z etosem uniwersytetu, na jaki składa się dążenie do prawdy i kultura otwartej dyskusji, konstytutywna dla wspólnoty uczących się i uczonych. Autor argumentuje, że przywiązanie do tych wartości jest nie tylko kwestią tradycji, ale szczególnym zadaniem uniwersytetu w ramach współczesnej sfery publicznej, targanej przez aksjologiczne konflikty i rozpadającej się na szereg cyfrowych „plemion”. Uniwersytet jako instytucja rozwinął się wraz z kulturą aksjologicznego pluralizmu i racjonalnego wątpienia, którą sam wspierał. Wartości tych nie da się jednak utrzymać, jeśli w ramach akademickiej doksy przyjmie się założenia radykalnego relatywizmu poznawczego. „Antyrelatywistyczne minimum poznawcze” (Steven Lukes) i założenie względnej przekładalności języków, są niezbędne, jeśli uniwersytet ma pełnić nadal społecznie istotną funkcję wspierania dyspozycji krytycznych i uczenia samodzielności myślowej.
The article is a critical comment on the contemporary condition of the university and the reform of higher education introduced in Poland in 2018 (the so-called reform 2.0). The management culture imposed by the reform, focused on “scientific productivity” and bibliometrics, is in conflict with the university’s ethos of striving for truth and open discussion, constitutive for the community of learners and scientists. The author argues that attachment to these values is not only a matter of tradition, but a special task of the university within the contemporary public sphere, torn by axiological conflicts, and disintegrating into a number of digital “tribes”. The university as an institution developed along with the culture of axiological pluralism and rational doubt, which is supported itself. However, these values cannot be maintained if the academic doxa adopts the assumptions of radical cognitive relativism. “Anti-relativistic cognitive minimum” (Steven Lukes) and the assumption of relative translatability of languages are necessary if the university is to continue to play the socially important function of supporting critical dispositions and intellectual independence.
Źródło:
Acta Universitatis Lodziensis. Folia Philosophica. Ethica – Aesthetica – Practica; 2021, 38; 7-26
0208-6107
2353-9631
Pojawia się w:
Acta Universitatis Lodziensis. Folia Philosophica. Ethica – Aesthetica – Practica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing of Sinters Made of Copper Powders Coated with Carbon Structure Containing Graphene
Badania spieków wykonanych z zastosowaniem proszków miedzi pokrytej strukturą węglową zawierającą grafen
Autorzy:
Rajkowski, Kamil
Majewski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1837982.pdf
Data publikacji:
2021
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
mechanical engineering
material engineering
powder metallurgy
sintered copper
graphene
inżynieria mechaniczna
inżynieria materiałowa
metalurgia proszków
spieki miedzi
grafen
Opis:
This paper presents the results of preliminary tests on specimens made from mixtures of dendritic copper powder (CuE) with the graphene-coated copper powder (CuG) in a range from 20% to 100% (CuG). The properties of the powder mixtures, green compacts and sinters were determined. To study the properties of the powder mixtures, the following tests were carried out: a measurement of the CuG powder grain size after the grinding process, measurements of the bulk density and tap density of the prepared powder mixtures. The porosity of the produced green compacts and the sinters was calculated as well as the densification capabilities of the powder mixtures by die pressing, cold isostatic pressing and sintering in a reducing atmosphere were tested. Moreover, the nature of the porosity formation was analysed using an optical microscope and the Brinell hardness was determined. The measured Brinell hardness was in the range of 17 HB for sinters made from CuG to 34 HB for sinters made from a 20% CuG powder mixture. More than six hundred measurements that were made in this study show that the high CuG content in the powder mixture reduces the hardness of the sinters as well as increase their porosity.
W artykule zostały przedstawione wyniki wstępnych badań próbek wykonanych z mieszanin proszku miedzi dendrytycznej (CuE) z proszkiem miedzi pokrytym strukturą węglową zawierającą grafen (CuG) w przedziale od 20% do 100% (CuG). W ramach badań określone zostały właściwości mieszaniny proszków, wyprasek oraz spieków, składające się na opis badanego materiału. W celu zbadania właściwości mieszanin proszków zostały wykonane następujące badania: pomiar wielkości ziaren proszku CuG po procesie rozdrabniania, pomiar gęstości nasypowej oraz nasypowej z usadem przygotowanych mieszanin. Obliczono porowatość wytworzonych wyprasek, a następnie spieków oraz sprawdzono możliwości zagęszczania się otrzymanych mieszanin poprzez zastosowanie prasowania matrycowego, prasowania izostatycznego na zimno oraz spiekania w atmosferze redukującej. Dokonano również analizy powierzchni wykonanych próbek pod kątem charakteru powstałych porów za pomocą mikroskopu optycznego oraz określono twardość próbek metodą Brinella. Zmierzona twardość próbek mieści się w zakresie od 17HB dla spieków wykonanych wyłącznie z CuG do 34HB dla spieków wykonanych z mieszanki zawierającej 20% CuG. W ramach badań wykonanych zostało ponad sześćset pomiarów, których wyniki pokazują, że duża zawartość CuG w mieszaninie proszkowej zmniejsza twardość otrzymanych z niej spieków oraz zwiększa ich porowatość.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2021, 12, 2 (44); 75-90
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uszkodzenia pożarowe dachu budynku kościoła pw. Świętych Apostołów Piotra i Pawła w Gdańsku
Fire damage to the roof of the church building of the Saint Apostles Peter and Paul in Gdańsk
Autorzy:
Majewski, Tomasz
Niedostatkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/2055972.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
dach
Kościół pw. świętych Apostołów Piotra i Pawła w Gdańsku
uszkodzenie pożarowe
element stalowy
obciążenie ogniowe
więźba dachowa
naprawa
roof
Saints Peter and Paul Church in Gdańsk
fire damage
steel element
fire load
roof truss
repair
Opis:
Pożar powoduje nie tylko straty materialne, ale także realne zagrożenie dla zdrowia i życia ludzi. Skutki usunięcia następstw pożaru są nie tylko kosztowne, ale także stwarzają bardzo duże trudności organizacyjne. W wyniku szkód pożarowych obiekty budowlane mogą kwalifikować się do całkowitego lub częściowego wyburzenia, a także do odbudowy. Kwestia odbudowy zniszczonych przez pożar budynków lub ich elementów jest tym trudniejsza, gdy dotyczy obiektów objętych ochroną konserwatorską. W artykule przedstawiono opis zniszczeń spowodowanych pożarem dachu kościoła pw. Św. Apostołów Piotra i Pawła, który został częściowo zniszczony i wymagał odbudowy.
Fire causes not only material losses, but also a real threat to human health and life. The effects of removing the consequences of a fire are not only costly, but also create very large organizational difficulties. As a result of fire damage, construction works may qualify for total or partial demolition as well as reconstruction. The issue of reconstruction of fire-damaged buildings or their elements is even more difficult when it concerns objects under conservation protection. The paper presents a description of fire damage to the roof of the Church of St. Saint Apostles Peter and Paul which was partially destroyed and needed to be rebuilt.
Źródło:
Przegląd Budowlany; 2021, 92, 9; 43--47
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Posadzki antyelektrostatyczne kluczowym elementem ochrony przed elektrycznością statyczną – wybrane wymagania techniczne
Antistatic floors – a key element of protection against static electricity – selected technical requirements
Autorzy:
Świątek-Żołyńska, Sylwia
Majewski, Tomasz
Niedostatkiewicz, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/129432.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
posadzka antyelektrostatyczna
posadzka przemysłowa
antyelektrostatyczność
elektryczność statyczna
wymagania techniczne
antistatic floor
industrial floor
anti-electrostatic
static electricity
technical requirements
Opis:
Potrzeba odprowadzania ładunków elektrostatycznych z powierzchni posadzki, czyli ochrona przed elektrycznością statyczną, występuje w pomieszczeniach, w których w wyniku prowadzonych procesów technologicznych lub magazynowania składowane są substancje łatwopalne lub wybuchowe. Zagadnienie to jest również bardzo istotne w przypadku procesów produkcyjnych, gdzie rozładowanie nagromadzonego potencjału elektrycznego może spowodować uszkodzenie lub zniszczenie produkowanego elementu. Posadzki antyelektrostatyczne zapewniają skuteczną ochronę przed elektrycznością statyczną i dlatego stanowią bardzo istotny element w procesie projektowania oraz realizacji obiektów przemysłowych.
The need to discharge electrostatic charges from the floor surface, i.e. protection against static electricity, occurs in rooms where flammable or explosive substances are stored as a result of technological processes or storage. This issue is also very important in the case of production processes where the discharge of accumulated electrical potential can damage the manufactured element. Antistatic floors provide effective protection against static electricity and are therefore a very important element in the design and implementation of industrial facilities.
Źródło:
Builder; 2020, 24, 6; 40-42
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przywództwo : konteksty : reminiscencje : odniesienia
Konteksty : reminiscencje : odniesienia
Autorzy:
Majewski, Tomasz.
Współwytwórcy:
Kurek, Dorota (zarządzanie). Autor
Szulc, Bogdan M. (1945- ). Autor
Akademia Sztuki Wojennej. Instytucja sprawcza
Wydawnictwo Akademii Sztuki Wojennej. Wydawca
Data publikacji:
2020
Wydawca:
Warszawa : Wydawnictwo Akademii Sztuki Wojennej
Tematy:
Dowodzenie (wojsk.)
Kompetencje przywódcze
Przywództwo (wojsk.)
Opracowanie
Opis:
Bibliografia na stronach 188-195.
Dostawca treści:
Bibliografia CBW
Książka

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies