Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "standard method" wg kryterium: Temat


Tytuł:
A method of assessing the tendency of aviation fuels to generate thermal degradation products under the influence of high temperatures
Autorzy:
Sarnecki, J.
Gawron, B.
Powiązania:
https://bibliotekanauki.pl/articles/246718.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
jet fuel
turbine engine
thermal stability
test rig
non-standard method
Opis:
The subject of the article concerns the issues associated with thermal degradation of aviation fuels under high temperature conditions. Due to the intensive development towards increasingly higher thermal loads for both, turbine aviation engines, as well as the used fuels, the issue of thermal stability of the fuel itself is extremely important. In aviation, the fuel, apart from direct participation in energy generation during the combustion process of a fuel-air mixture, also takes part in the heat transfer in many aircraft systems. As a result, requirements in terms of the fuel’s thermal potential are increasingly higher. The standard method for determining the thermal stability of fuel executed on a JFTOT device proves to be insufficient in the context of the appearing issues in current operation. The article presents a non-standard approach to the assessment of aviation fuel thermal degradation with the use of a specialist test rig. The authors believe that the presented methodology and the measurement capabilities of the test rig are valuable supplementary material for the standardized thermal stability test. It allows more thoroughly understanding the phenomena undergoing in the fuel impacted by high temperatures. The article has been prepared within the research project no. 2011/01/D/ST8/06567 funded by the National Science Centre in Poland.
Źródło:
Journal of KONES; 2017, 24, 4; 377-384
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DETERMINATION OF PARACETAMOL IN COMMERCIAL SUPPOSITORIES USING DIFFERENTIAL SCANNING CALORIMETRY
Autorzy:
Leyk, Edyta
Komar, Sebastian
Wesołowski, Marek
Powiązania:
https://bibliotekanauki.pl/articles/895533.pdf
Data publikacji:
2019-04-30
Wydawca:
Polskie Towarzystwo Farmaceutyczne
Tematy:
paracetamol
DSC determination
multiple standard addition method
commercial suppositories
Opis:
Paracetamol, also known as acetaminophen, has been commonly used as a major active pharmaceutical ingredient in numerous analgesics for over 30 years. This means that specific and reliable methods are crucial for quality control of its formulations. The purpose of this work was to show to what extent differential scanning calorimetry (DSC) can be useful for the determination of paracetamol in formulations intended for rectal use. Suppositories commonly available in Polish pharmacies were chosen for the study. In order to assess the impact of various suppository bases on active ingredient determination in the formulations analyzed, the selection was made from various producers and with varying doses of paracetamol. DSC scans were taken on a heat-flux instrument with a liquid nitrogen cooling system. To achieve the aim of this study, a well-defined endothermic DSC peak was used, assigned to the melting-point of paracetamol at 168.64ºC with the heat of transition of 183.99 J/g. A multiple standard addition method was chosen for the calibration. Except for one formulation containing 50 mg of paracetamol, the relative standard deviation for all the DSC determinations varied over the range of 0.27 to 2.64%, while the relative error varied between 0.24 and 12.50%. The study demonstrated that DSC could successfully be employed as a simple, specific and reliable method for the determination of paracetamol in rectal preparations based on the measurement of its heat of fusion. The results are consistent with the data obtained using UV spectrophotometry (pharmacopoeial method) as reference.
Źródło:
Acta Poloniae Pharmaceutica - Drug Research; 2019, 76, 2; 241-249
0001-6837
2353-5288
Pojawia się w:
Acta Poloniae Pharmaceutica - Drug Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metody ISM-SAM do oznaczania pierwiastków śladowych w oleju napędowym
Application of the ISM-SAM method for the determination of trace elements in diesel fuel
Autorzy:
Kozak, M.
Powiązania:
https://bibliotekanauki.pl/articles/1835488.pdf
Data publikacji:
2017
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
optyczna spektrometria emisyjna plazmy indukcyjnie sprzężonej
metoda wzorca wewnętrznego
metoda dodatku wzorca
olej napędowy
inductively coupled plasma optical emission spectrometry
internal standard method
standard addition method
diesel fuel
Opis:
W artykule przestawiono sposób oznaczania pierwiastków śladowych w oleju napędowym z wykorzystaniem metody wzorca wewnętrznego połączonej z techniką dodatków wzorca (ISM-SAM). Jako wzorzec wewnętrzny wytypowano skand. Oznaczano miedź, krzem i cynk. Wyniki oznaczeń charakteryzują się bardzo dobrą precyzją – wartości współczynnika zmienności CV są mniejsze niż 1,2%. Uzyskano również dobrą zgodność wyników oznaczeń metodą ISM-SAM i metodą znormalizowaną.
The article presents the method of determination of trace elements in diesel fuel using the internal standard method combined with the standard additions method (ISM-SAM). Scandium was selected as the internal standard. Copper, silicon and zinc were determined. The results of the determinations are characterized by very good precision – the values of the coefficient of variation, CV are less than 1.2%. Good compatibility between the results of determinations of the ISM-SAM method and the standard method were also achieved.
Źródło:
Nafta-Gaz; 2017, 73, 9; 691-697
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Average Energy Slope Estimation Formulas for One-dimensional Steady Gradually Varied Flow
Autorzy:
Artichowicz, W.
Mikos-Studnicka, P.
Powiązania:
https://bibliotekanauki.pl/articles/241083.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
open channel
steady flow
gradually varied flow
standard step method
energy slope
Opis:
To find the steady flow water surface profile, it is possible to use Bernoulli’s equation, which is a discrete form of the differential energy equation. Such an approach requires the average energy slope between cross-sections to be estimated. In the literature, many methods are proposed for estimating the average energy slope in this case, such as the arithmetic mean, resulting in the standard step method, the harmonic mean and the geometric mean. Also hydraulic averaging by means of conveyance is commonly used. In this study, water surface profiles numerically computed using different formulas for expressing the average slope were compared with exact analytical solutions of the differential energy equation. Maximum relative and mean square errors between numerical and analytical solutions were used as measures of the quality of numerical models. Experiments showed that all methods gave solutions useful for practical engineering purposes. For every method, the numerical solution was very close to the analytical one. However, from the numerical viewpoint, the differences between the methods were significant, as the errors differed up to two orders of magnitude.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2014, 61, 3-4; 89--109
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie temperatury gleby mierzonej rtęciowymi termometrami kolankowymi i za pomocą stacji automatycznej w obserwatorium Wrocław-Swojec
The comparison of soil temperature measured with mercury thermometers and automatic stadion in Wrocław-Swojec observatory
Autorzy:
Kajewska, J.
Rojek, M.
Powiązania:
https://bibliotekanauki.pl/articles/338905.pdf
Data publikacji:
2010
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
istotność i częstość różnic
metoda klasyczna
stacja automatyczna
temperatura gleby
automatic station
significance and frequency of differences
soil temperature
standard method
Opis:
W pracy przedstawiono wyniki pomiarów temperatury gleby na dwóch głębokościach (5 i 10 cm) pod powierzchnią gleby pod trawnikiem i gleby nieporośniętej. Porównywano dane uzyskane metodą standardową (rtęciowe termometry kolankowe) i za pomocą stacji automatycznej Campbell CR23X. Wykorzystano wartości z pomiarów wykonanych w Obserwatorium Agro- i Hydrometeorologii UP Wrocław-Swojec w latach 2000-2008. Średnią dobową temperaturę gleby, mierzoną metodą standardową, obliczano na podstawie 3 terminów pomiarów (godz.: 7, 13 i 19 CET). Wartości ze stacji automatycznej były średnią arytmetyczną z 24 raportów godzinnych. Na obu głębokościach pomiarowych gleby pod trawnikiem, we wszystkich dekadach roku, większe wartości uzyskano z pomiarów rtęciowymi termometrami kolankowymi (metoda standardowa). Pod powierzchnią gleby nieporośniętej, w kilku dekadach miesięcy zimowych, nieco większe były wartości uzyskane za pomocą stacji automatycznej. Otrzymano bardzo wysokie współczynniki korelacji (r ≥ 0,999) między wynikami obu metod. Rozkłady częstości występowania różnic dwóch metod pomiarów temperatury gleby były odmienne dla obu analizowanych powierzchni i głębokości pomiarów. W glebie nieporośnietej, na obu głębokościach pomiarowych, najwięcej różnic wystąpiło w przedziale temperatury od -0,5°C do 0,5°C. W glebie pod trawnikiem, na głębokości 5 cm, najwięcej różnic stwierdzono w przedziale temperatury od 1,5°C do 2,5°C, a na głębokości 10 cm od 0,5°C do 1,5°C.
The paper presents the results of soil temperature measurements at two depths (5 and 10 cm) under bare soil and under a lawn. The data according to standard (mercury thermometers) and automatic station Campbell CR23X were compared. The research data were obtained from Agro- and Hydrometeorology Observatory Wrocław-Swojec of the Wrocław University of Environmental and Life Sciences from the period 2000-2008. Daily mean soil temperatures according to standard measurements were calculated from three records made at 7, 13, and 19 hour CET while those based on automatic measurements are the arithmetical means from hourly records. In all decades of the year, temperature under the lawn at two depths (5 and 10 cm) was higher than the values taken from automatic station. Temperatures under the bare soil recorded with automatic station were slightly higher in a few decades of the winter months. Very high correlation coefficients (r ≥ 0,999) were obtained between the two methods. Distribution of the frequency of occurrence of differences between the two methods differed depending on the type of surface and depths. In the bare soil at 5 and 10 cm depths most differences occurred in the range from -0.5 to 0.5°C. Under the lawn at 5 cm most frequent differences were found in the range 1.5-2.5°C and at 10 cm - between 0.5 and 1.5°C.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2010, 10, 4; 79-93
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Towards miniaturized sensors for determination of exchangeable potassium in soil samples
Autorzy:
Grygolowicz-Pawlak, E.
Plachecka, K.
Wolanin, B.
Malinowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/25360.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
soil analysis
measurement
soil
inductively coupled plasma-mass spectroscopy
atomic absorption spectroscopy
miniaturization
potentiometric electrode
standard method
nutrient level
flame emission spectroscopy
Źródło:
International Agrophysics; 2006, 20, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie szeregów czasowych do oceny różnic wartości niedosytu i wilgotności względnej powietrza mierzonych dwiema metodami
Using time series to assess the differences in saturation deficit and relative and humidity measured by two methods
Autorzy:
Kajewska, J.
Rojek, M.
Powiązania:
https://bibliotekanauki.pl/articles/339406.pdf
Data publikacji:
2011
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
metoda klasyczna
niedosyt wilgotności powietrza
stacja automatyczna
szeregi czasowe
wilgotność względna powietrza
automatic station
relative air humidity
saturation deficit
standard method
time series
Opis:
W pracy porównano wyniki pomiarów warunków wilgotnościowych powietrza wykonywanych dwiema metodami na terenie Obserwatorium UP Wrocław-Swojec w okresie 10-letnim (2000-2009). Analizowano dobowe wartości niedosytu wilgotności d i wilgotności względnej powietrza f. Pomiary klasyczne (standardowe) wykonywano za pomocą psychrometru Augusta, umieszczonego w klatce meteorologicznej na wysokości 2 m nad powierzchnią terenu. Średnią dobową obliczano na podstawie trzech pomiarów terminowych (godz.: 7, 13 i 19 CET) dla niedosytu wilgotności powietrza i czterech pomiarów (godz.: 1, 7, 13 i 19 CET) dla wilgotności względnej powietrza; wartości z godziny 1 odczytywano z termohigrogramu dobowego. Automatyczna stacja meteorologiczna Campbell CR23X, której czujnik wilgotności powietrza umieszczono w tej samej klatce meteorologicznej, była zaprogramowana na zapisywanie raportów godzinnych. Średnie dobowe wartości obu parametrów były średnią arytmetyczną z 24 wartości godzinnych. Analizy autokorelacji i autokorelacji cząstkowej potwierdziły występowanie rocznej sezonowości badanych parametrów. Dekompozycję szeregów czasowych przeprowadzono za pomocą modelu addytywnego. Wyizolowano składnik sezonowy, trend, wahania długookresowe oraz składnik losowy. Wskaźnik sezonowości dla wilgotności względnej wahał się od -4% (zima) do 6% (okres letni), natomiast dla niedosytu wilgotności zawierał się w przedziale od -1,5 hPa w zimie do 4,0 hPa w lecie. Sezonowość różnic dobowych wartości f i d wyrażała się wzrostem ich wartości bezwzględnych w okresie letnim dla obu analizowanych parametrów. Korekta wartości uzyskanych za pomocą stacji automatycznej z wykorzystaniem odpowiednich poprawek, spowodowała wyraźny wzrost częstości różnic w przedziałach środkowych.
The study presents the results of a comparison between air humidity conditions measured with two methods in Wroclaw–Swojec Observatory during the 10-year period (2000-2009). Daily values of saturation deficit (d) and relative air humidity (f) have been analyzed. Standard measurements were conducted using August psychrometer placed in a meteorological screen, 2 m above the ground surface. Mean daily values were calculated based on three terminal measurements (7, 13 and 19 GMT) for saturation deficit, and four measurements (1, 7, 13 and 19 GMT) for relative air humidity, the 1 a.m. values were read from the daily thermohigrograph. Automatic weather station Campbell CR23X with humidity sensor placed in the same meteorological screen was programmed to store hourly reports. Automatic daily averages of both humidity parameters were the arithmetic means of the 24-hour values. Analysis of autocorrelation and partial autocorrelation confirmed the annual seasonality of analyzed parameters. The decomposition of time series was carried out using an additive model. Seasonal component, trend, long-term fluctuation and irregular component were isolated. Seasonal index for relative humidity ranged from -4% (winter) to 6% (summer), while that for saturation deficit ranged from -1.5 hPa in winter to 4.0 hPa in summer. The seasonality of differences between daily values manifested itself by an increase of their absolute values in the summer for both analyzed parameters. Appropriate corrections of the values obtained from automatic measurements resulted in a marked increase in the frequency of differences in central classes.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2011, 11, 4; 137-148
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmodyfikowana metoda dodatku wzorca w analizie rentgenofluorescencyjnej
Autorzy:
Mzyk, Z.
Anyszkiewicz, J.
Gorewoda, T
Powiązania:
https://bibliotekanauki.pl/articles/273745.pdf
Data publikacji:
2014
Wydawca:
Roble
Tematy:
spektrometria rentgenofluorescencyjna
kalibracja prostoliniowa
metoda dodatku wzorca
X-ray fluorescence spectrometry
straight calibration
standard addition method
Źródło:
LAB Laboratoria, Aparatura, Badania; 2014, 19, 1; 6-8
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie szeregów czasowych do oceny różnic temperatury powietrza mierzonej metodą klasyczną i automatyczną
Using time series for the comparison of air temperature measured standard and automatic station
Autorzy:
Kajewska-Szkudlarek, J.
Powiązania:
https://bibliotekanauki.pl/articles/338710.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
ekstremalne temperatury powietrza
metoda klasyczna
stacja automatyczna
szeregi czasowe
średnia temperatura powietrza
automatic station
extreme air temperature
mean air temperature
standard method
time series
Opis:
W pracy porównywano wyniki pomiarów średniej tp, maksymalnej tmax i minimalnej tmin temperatury powietrza metodą klasyczną i automatyczną na terenie Obserwatorium Uniwersytetu Przyrodniczego Wrocław-Swojec w okresie 2000-2009. Analizowano ich dobowe wartości. Pomiary standardowe wykonywano za pomocą termometru stacyjnego i termometrów ekstremalnych, umieszczonych w klatce meteorologicznej 2 m ponad powierzchnią gruntu. Średnią dobową tp obliczano z czterech terminów pomiarowych (1, 7, 13, 19 CET), a wartość z godziny 1 w nocy uzyskiwano z termohigrografów dobowych. Jednocześnie prowadzono pomiary za pomocą automatycznej stacji meteorologicznej Campbell. Elektroniczny czujnik temperatury powietrza MP 100A Rotronik umieszczony był w tej samej klatce meteorologicznej, co przyrządy manualne. Sensor zaprogramowano na pomiar co 60 s oraz na zapisywanie ekstremalnych wartości temperatury powietrza wraz z terminem, w którym wystąpiły. Na podstawie wartości minutowych obliczano średnie godzinne, a z nich - średnie dobowe. W większości przypadków, w latach 2000-2009, termometry cieczowe wskazywały wyższą temperaturę niż czujniki elektroniczne. Średnie różnice między tymi wartościami wynosiły +0,8°C w przypadku tp oraz +0,9°C w przypadku tmax i +1,1°C w przypadku tmin. Największe różnice były równe: +4,4°C (tp), +12,5°C (tmax) i +10,5°C (tmin). Tak duże wartości notowano incydentalnie. Szeregi czasowe różnic nie podlegały sezonowym zmianom, co potwierdziła analiza autokorelacji i autokorelacji cząstkowej. Transformacja danych automatycznych spowodowała zbliżenie skorygowanych średnich dobowych wartości temperatury powietrza do danych klasycznych. Wyraźnie też zwiększyła się częstość występowania różnic w środkowych zakresach wartości.
The study presents the result of a comparison between air thermal parameters measured with standard (manual) and automatic method in the Wroclaw-Swojec Observatory in the period 2000- 2009. Daily values of mean air temperature (tp), maximum (tmax) and minimum (tmin) air temperature were analyzed. Manual measurements were conducted using standard and extreme thermometers placed 2 meters above the ground in a meteorological screen. The average daily values of tp were calculated from four temporal measurements (1, 7, 13, 19 CET); values from 1 a.m. were obtained from daily thermohygrographs. Parallel to standard observations, measurements were performed with the Campbell automatic weather station. Electronic sensor for measuring air temperature (MP 100A Rotronik) was placed in the same screen, in which manual devices were situated. This sensor was programmed to sample every 60 seconds and to record the extreme values of air temperature and the hour they had occurred. Hourly averages from automatic station were calculated from minute measurements and mean daily tp was calculated from hourly values. In most cases, during the period 2000-2009, standard thermometers showed higher temperature than electronic sensors. Mean differences between values from both stations were 0.8°C for tp, 0.9°C for tmax and 1.1°C for tmin. The greatest differences were: 4.4°C (tp), 12.5°C (tmax), 10.5°C (tmin), but so high values occurred incidentally. Time series of differences did not show seasonal changes, chich was confirmed by the analysis of autocorrelation and partial autocorrelation. Transformation of automatic data resulted in much closer adjustment of air temperature values to standard in the comparison with original automatic daily data. Moreover, the frequency of differences in the middle ranges significantly increased.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 4; 151-162
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prosty sposób przybliżonego określania przepuszczalności horyzontu gazowego na podstawie danych okresu przypływu i bilansu masy gazu
How to approximate the permeability of the gas zone using the gas flowing pressure data and the mass balance
Autorzy:
Szpunar, Tadeusz
Budak, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/1833982.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
metoda standardowa
wykres ciśnienia dennego
przepuszczalność skały
skin efekt
bilans masy
modelowanie matematyczne
standard method
drowndown pressure curve
rock permeability
skin effect
mass balance
mathematical modelling
Opis:
The routine procedure for evaluation of the permeability and skin of the gas zone consists in flowing the gas well until the bottomhole pressure is nearly stabilized. The pressure values must be recorded versus time of flow, initial reservoir pressure must be known and the constant flow rate should be maintained during the flow test. The permeability and skin are calculated using the straight line approximation of bottomhole pressures versus logarithm of flowing time, and the permeability is calculated using the slope of this line. The standard method for calculation of permeability and skin is known for decades and will not be discussed here. This paper proposes somewhat different technique for calculation of permeability which is based on mathematical model of gas flow in porous rocks given by Szpunar (2001). The total volume of gas produced during the flow period is used for calculation of permeability instead of using the flow rate which is never known precisely. The reliability of the calculated results is checked by comparing the total mass of gas produced during the flow test (evaluated at standard conditions of temperature and pressure) with the mass of gas evacuated from the reservoir predicted by the mathematical model. The article provides calculation examples. Because no data from domestic oil industry was available, the method was tested using the data from technical literature. The discrepancies between the results of both methods are within the acceptable range of a few percent.
Źródło:
Nafta-Gaz; 2020, 76, 12; 895--902
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie średniej dobowej temperatury i wilgotności powietrza mierzonych i obliczanych metodami standardową i automatyczną
Daily mean values of air temperature and humidity measured and calculated with the standard and automatic method
Autorzy:
Kajewska-Szkudlarek, J.
Rojek, M.
Powiązania:
https://bibliotekanauki.pl/articles/337761.pdf
Data publikacji:
2013
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
metoda klasyczna
parametry termiczne i wilgotnościowe powietrza
stacja automatyczna
szeregi czasowe
średnie dobowe
air thermal and humidity parameters
automatic station
daily mean values
standard method
time series
Opis:
W pracy analizowano średnie dobowe wartości temperatury, wilgotności względnej oraz niedosytu wilgotności powietrza uzyskane podczas trzech lub czterech w okresie doby pomiarów przyrządami klasycznymi oraz czujnikami elektronicznymi z tych samych terminów i z wszystkich 24 godzin. Pomiary standardowe wykonywano za pomocą termometru stacyjnego i psychrometru Augusta. Niedosyt wilgotności powietrza odczytywano z tablic psychrometrycznych. Średnią dobową obliczano na podstawie pomiarów z 7, 13 i 19 CET dla niedosytu wilgotności powietrza i z 1, 7, 13 i 19 CET dla temperatury i wilgotności względnej powietrza. Automatyczną stację meteorologiczną CR23X zaprogramowano na rejestrowanie raportów godzinnych. Średnie wartości dobowe według pomiarów automatycznych były średnią arytmetyczną z 24 wartości godzinnych lub z tych samych terminów, w których wykonywano obserwacje manualne. Do oceny, czy zmiana sposobu obliczania średnich powoduje zmniejszenie różnic między obiema metodami, wykorzystano analizę regresji liniowej, ocenę częstości i istotności różnic oraz analizę szeregów czasowych (tj. analizę autokorelacji i dekompozycję sezonową). Obliczanie średniej dobowej temperatury i wilgotności względnej powietrza według stacji automatycznej z czterech pomiarów terminowych zamiast 24 wartości godzinnych nie spowodowało zmniejszenia różnic między obiema metodami pomiaru tych elementów meteorologicznych. Jedynie w przypadku niedosytu wilgotności powietrza wartości średnie obliczone z trzech dziennych terminowych pomiarów czujnikami elektronicznymi były bardziej zbliżone do danych otrzymanych metodą klasyczną niż średnie z wszystkich 24 godzin. Wynika to z pomijania we wzorze na średnią dobową według metody klasycznej wartości z godzin nocnych i skutkuje jego zawyżaniem w stosunku do danych otrzymywanych na podstawie automatycznych pomiarów ciągłych.
The study presents the results of an analysis of mean daily values of air temperature, relative humidity and saturation deficit from three or four (depending on the parameter) measurements a day with standard devices and from 24 hourly records made with electronic sensors recording on the same days. Data were obtained from Wroclaw-Swojec Observatory during the period 2000-2009. Standard measurements were made using the station thermometer and August psychrometer, placed in a meteorological screen 2 m above the terrain surface. Saturation deficit was read from psychrometer tables. Daily mean values were calculated based on three fixed-term measurements (at 7, 13 and 19 CET) for air saturation deficit and on four measurements (1, 7, 13 and 19 CET) for temperature and relative humidity, the values for 1 a. m. were read from daily thermohygrographs. Electronic temperature and humidity sensors were placed in the same meteorological screen and programmed to record hourly data. The sensors were components of a CR23X automatic meteorological station. Automatic mean daily values were calculated from 24 hours and from the same terms, when standard observations were conducted. Linear regression, frequency and significance of differences, time series analysis (i.e. autocorrelation analysis and seasonal decomposition using the additive model) were performed to determine whether a change in the method of calculating mean daily values might decrease the differences between the two methods. Calculating the mean daily temperature and relative humidity recorded by automatic station Turing four measurements instead of using 24 hourly data did not decrease differences between the two methods of meteorological elements measurement. Only in the case of the deficit of air humidity, the daily means calculated from three automatic records were much more similar to those obtained with the standard method than those from all 24 hourly records. This was caused by neglecting night records when calculating the saturation deficit of air humidity according to the standard method. This in turn resulted in the overestimation of these data compared with those obtained from continuous automatic measurements.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2013, 13, 1; 59-73
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Energy Slope Averaging Methods on Numerical Solution of 1D Steady Gradually Varied Flow
Autorzy:
Artichowicz, W.
Prybytak, D.
Powiązania:
https://bibliotekanauki.pl/articles/240952.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
standard step method
numerical integration
initial-value problem
ordinary differential equation
open channel
steady gradually varied flow
energy slope
Opis:
In this paper, energy slope averaging in the one-dimensional steady gradually varied flow model is considered. For this purpose, different methods of averaging the energy slope between cross-sections are used. The most popular are arithmetic, geometric, harmonic and hydraulic means. However, from the formal viewpoint, the application of different averaging formulas results in different numerical integration formulas. This study examines the basic properties of numerical methods resulting from different types of averaging.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2015, 62, 3-4; 101-119
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwość przyspieszonego oszacowania absorpcji wody przy długotrwałej dyfuzji pary wodnej przez stryropian i polistyren ekstrudowany
Assessment of test results of long term (28 days) water absorption by diffusion for expanded and extruded polystyrene - on the basis of short time results
Autorzy:
Bobociński, A.
Powiązania:
https://bibliotekanauki.pl/articles/183054.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniki Budowlanej
Tematy:
płyta styropianowa
płyta XPS
absorpcja wody
para wodna
dyfuzja
grubość
próbka
badanie normowe
metoda szacunkowa
metoda badań
wyniki badań
foamed polystyrene panel
expanded polystyrene
water absorption
water vapour
diffusion
sample thickness
standard method
assessment method
test method
test results
Opis:
Przedstawiono wyniki przebiegu absorpcji wody przy długotrwałej dyfuzji pary wodnej przez styropian (EPS) oraz polistyren ekstrudowany (XPS). Absorpcję wody określano po upływie 4, 7, 14 i 28 dni ekspozycji próbek w warunkach określonych w PN-EN 12088:2000. Celem badań było uzyskanie danych empirycznych do oszacowania wyniku badania 28-dniowego (normowego) po 4-14 dniach od rozpoczęcia badania. Potrzeba takiego oszacowania wynika ze względów praktycznych (optymalne określenie zakresu badań normowych) i została zgłoszona przez zleceniodawców. W artykule oprócz wyników podano również empiryczne parametry (mnożniki) pozwalające oszacować wyniki badania 28-dniowego po upływie 4, 7 i 14 dni od rozpoczęcia ekspozycji próbek. We wnioskach stwierdzono, że możliwe jest oszacowanie wyniku badania absorpcji, które w większości przypadków będzie na tyle jednoznaczne, że spełni oczekiwania zleceniodawców badań.
This paper describes test results of water absorption by diffusion after 4, 7, 14 and 28 days for expanded polystyrene (EPS) and extruded polystyrene (XPS). Conditions of test are defined in standard PN-EN 12088:2000. The purpose of this tests was to obtain the experimental data for assessment of 28 days standard absorrption on the basis of results received during 4-14 days from the beginning of test. Empirical parameters for estimation of full time test results, based on this experimental data, are presented in paper.
Źródło:
Prace Instytutu Techniki Budowlanej; 2010, R. 39, nr 3, 3; 27-32
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena ekonomiczna kierunków działalności rolniczej gospodarstw ekologicznych mierzona standardową nadwyżką bezpośrednią "2006"
Economic evaluation of agricultural activity trends in ecological farms measured with the standard gross margin 2006 method
Autorzy:
Prokopowicz, J.
Jankowska-Huflejt, H.
Powiązania:
https://bibliotekanauki.pl/articles/336878.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
ocena ekonomiczna
gospodarstwo ekologiczne
rolnictwo
nadwyżka bezpośrednia
economic estimation
ecological farm
agricultural trend
Standard Gross Margin Method
Opis:
Badania przeprowadzono w latach 2005-2007 metodą ankietową. Dane uzyskano z 34 wybranych ekologicznych gospodarstw rolnych. Celem pracy było określenie kierunków działalności rolniczej badanych gospodarstw ekologicznych w latach 2005-2007, za pomocą standardowej nadwyżki bezpośredniej "2006", przyjętej jako główne kryterium oceny ekonomicznej gospodarstwa. Wartość nadwyżki bezpośredniej wykazuje tendencję zwyżkową, zarówno na ha UR, jak i osobę stale zatrudnioną w gospodarstwie. Jedynie susza 2006 r. spowodowała załamanie tego trendu w gospodarstwach kilku województw. Średnio nadwyżka bezpośrednia z omawianych trzech lat, wyniosła 3083 zł/ha UR i 33930 zł/osobę stale pracującą w gospodarstwie i wahała się od 1975 zł/ha UR w woj. podkarpackim do 3743 zł/ha UR w woj. podlaskim i od 17332 zł w małopolskim do 54394 zł/osobę w pomorskim. Ogólnie najkorzystniejszy był rok 2007, a najmniej korzystny 2006. Nadwyżka bezpośrednia z/ha UR obniża się średnio wraz ze wzrostem obszaru gospodarstwa. I odwrotnie - w przeliczeniu na osobę stale zatrudnioną - wzrasta wraz ze wzrostem obszaru gospodarstwa. Według klasyfikacji UE wśród badanych gospodarstw rolnych wydzielono 5 typów ogólnych (z 9 wydzielanych w UE), 7 typów podstawowych (z 17 w UE) i 10 - szczegółowych (z 50 w UE). Określono również klasy wielkości produkcji w Europejskich Jednostkach Wielkości (ESU), wg której każde gospodarstwo zaliczane jest do jednej z IX klas. Z typów ogólnych 44% gospodarstw zakwalifikowano do typu 4 (specjalizujące się w chowie zwierząt żywionych w systemie wypasowym) i zaliczono do VII klasy - średnio dużych (ESU 29,3). Z kolei 41% gospodarstw typu podstawowego zaliczono do typu 41 (bydło mleczne), te z klasy średnio dużych (31,2 ESU). Z 10 typów szczegółowych najwięcej gospodarstw zaliczono do typu 411 (krowy mleczne), z klasy średnio duże (ESU 31,2).
Studies were carried out in the years 2005-2007 with the questionnaire method. Data were obtained from 34 selected ecological farms. The paper was aimed at estimating agricultural trends in studied farms in the years 205-2007 with the Standard Gross Margin Method "2006" adopted as the main criterion of economic evaluation of farms. Gross margin showed an increasing trend when calculated both per ha of croplands and per person employed in a farm. Drought in the year 2006 slumped this trend in farms from several voivodeships. Mean gross margin from the three years under study was 3083 zł/ha croplands and 33930 zł/person permanently employed in a farm and ranged from 1975 zł/ha croplands in podkarpackie province to 3743 zł/ha in podlaskie province and from 17332 zł/person in małopolskie province to 54394 zł/person in pomorskie province. In general, the most favourable was the year 2007 and the least - 2006. Gross margin calculated per ha of croplands decreased with the increased farm size; that calculated per permanently employed person increased in the same direction. According to the EU classification 5 general types (out of 9 used in the EU), 7 basic types (out of 17 in the EU) and 10 detailed types (out of 50 European ones) were distinguished among studied farms. Classes of production were also estimated in the European Size Units, acc. to which every farm is counted to one of IX classes. 44% of farms were counted to type 4 of the general types (specialized in breeding animals fed in the grazing system) and classified to the VII size class of moderately large farms (ESU 29.3). 41% of the basic types farms were counted to the 41 type (dairy cattle) of the moderately large class (ESU 31.2) and out of 10 detailed types most farms were counted to type 411 (dairy cows) of the moderately large class (ESU 31.2).
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2008, 53, 4; 45-50
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of atmosphere delays in processing of aircraft’s coordinates determination
Autorzy:
Krasuski, K.
Wierzbicki, D.
Powiązania:
https://bibliotekanauki.pl/articles/244235.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
GPS
SPP method
accuracy
standard deviation
atmosphere delays
Opis:
In this article, the study's results of aircraft’s coordinates and their accuracy are presented. The airborne test was conducted in military airport in Deblin on 1st of June 2010. The aircraft position was determinate using SPP method in RTKPOST library in RTKLIB software. To calculate the aircraft’s coordinates two strategies were used, first include correction of atmosphere delays (I solution) and another without this correction (II solution). Based on these calculations, the average accuracy of aircraft position is less than 5 m for solution I and less than 8 m for solution II, respectively. The mathematical model for recovery of aircraft position; the configuration of parameters in SPP method for solution; the standard deviation values of X, Y and Z coordinates; the values of RMS-3D parameter are presented in the article. In this article, the impact of ionosphere and troposphere delay in processing of recovery of aircraft position is presented. The aircraft’s coordinates were obtained using SPP (Single Point Positioning) method for two solutions, e.g. including atmosphere corrections (I solution) and excluding (II solution). The article is divided into 5 sections: introduction, mathematical model for recovery of aircraft position, research experiment, results and discussion, conclusions.
Źródło:
Journal of KONES; 2016, 23, 2; 209-214
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies