Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "mean size" wg kryterium: Temat


Tytuł:
Universal equations for Pythagorean and Sauter-type formulas of mean value calculation and classification of the Extended Pythagorean Means
Autorzy:
Drzymała, J.
Powiązania:
https://bibliotekanauki.pl/articles/88936.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Wydział Geoinżynierii, Górnictwa i Geologii. Instytut Górnictwa
Tematy:
average value
mean size
mean diameter
weighted mean
Opis:
A general equation, combining the Pythagorean and Sauter-type formulas, which can be used for calculation of a mean of a set of values is given and discussed in the paper. A classification of means, forming the Extended Pythagorean Means family, including power (arithmetic, geometric, quadratic, cubic, etc.), inverted power (harmonic, inverted quadratic, inverted cubic, etc.), and Sauter-type (volumesurface, volume-length, etc.) is presented. The calculated means, depending on their type, are different. Formulas for calculating mean values for a set of values treated individually, in groups and as a fraction (weighted mean) are also given.
Źródło:
Mining Science; 2017, 24; 227-235
2300-9586
2353-5423
Pojawia się w:
Mining Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Proposal of concept for structural modelling of hybrid beams
Autorzy:
Kożuch, Maciej
Skrętkowicz, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2172884.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sand
mean grain size
mean pore size model
pore size distribution
water retention curve
Opis:
Investigation on the behaviour of a hybrid beam is presented. Hybrid beam stands for an element with hybrid cross sections. This means sections that consist of steel and concrete parts, connected together with composite dowels, and both are considered for shear flow analysis. In practice, a more general solution may be used for bridges in the form of a beam in which the span sections are hybrid and the support sections are concrete. Recently such a solution has been introduced for bridge engineering in Poland and a new problem with performing a global analysis of hybrid beams was identified. The solution is new itself and requires also a new approach for internal forces determination. Discussion of this problem is made in the paper. Influences of (1) concrete cracking, (2) rheology of concrete and (3) methods of modelling on the redistribution of internal forces are highlighted. On an example of one of the real bridge girder (being currently under design) analysis is made to show how the abovementioned factors are affecting obtained results. Results are analysed and conclusions are presented. As a final step, a new concept of hybrid beam design is proposed. The proposed solution enables a quick and easy engineering approach to perform a static calculation of the considered structure.
Źródło:
Studia Geotechnica et Mechanica; 2022, 44, 4; 317--332
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An analytical model to predict water retention curves for granular materials using the grain-size distribution curve
Autorzy:
Bouacida, Linda
Feia, Sadok
Denine, Sid Ali
Della, Noureddine
Powiązania:
https://bibliotekanauki.pl/articles/2172891.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sand
mean grain size
mean pore size
density index
model
pore size distribution
water retention curve
Opis:
The present work aims to propose a new analytical model intended to predict the water retention curves for granular materials based on data from tensiometric tests. Different analytical models have been used for the evaluation of soil water retention curves so far. It should be noted that the proposed model considers only one criterion in the selection of soils. This criterion is the physical property of particle distribution curve that can be used to determine the values of D50 and CU. In this study, the pore-access size distribution is investigated considering the effect of the coefficient of uniformity of sandy soils that were prepared with different density indexes (0.5, 0.7, and 0.9). Moreover, the proposed model equation is based on the physical properties of soil. This equation made it possible to describe the water retention curve and to estimate the pore-access size distribution without performing any experimental tests. The findings allowed asserting that the uniformity of the particle size curves corresponds to a good uniformity of the pore-access size distribution. In addition, it was revealed that the suction increased as the density index went up, which matches well with the experimental data. Moreover, it may clearly be noted that the distinctive retention properties of unsaturated soils can be observed on the above-mentioned curves. Further, it was found that the ratio of the grain size over the pore-access size increased as the uniformity coefficient augmented.
Źródło:
Studia Geotechnica et Mechanica; 2022, 44, 4; 354--369
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural modification of cellulose to enhance the flotation efficiency of fine copper oxide ore
Autorzy:
Gu, Guohua
Zhu, Renfeng
Chen, Zhixiang
Powiązania:
https://bibliotekanauki.pl/articles/109394.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fine malachite
collector
sulfuration flotation
contact angle
mean size
flocculation
Opis:
Using more efficient collector to improve the recovery efficiency of fine copper oxide has become imperative as the shortage of copper mineral resources. In this study, the new collector 3-hydroxy butyrate-carboxy methyl cellulose xanthate (HCMCX) was synthesized by carboxy methyl cellulose, 3-hydroxy butyrate and carbon disulfide, all of which as raw materials . The structural characteristics of HCMCX was detected by both infrared spectrum and ultraviolet spectrum. Besides, the interacting behavior between HCMCX and fine malachite was investigated through particle size analysis, contact angle measurements, and flotation tests. Particle size analysis indicated that the mean size of malachite was increased by 8 μm while the HCMCX concentration at 200 mg/dm3. The contact angle measurements demonstrated that, comparing with the collector AX at a same dosage, the mineral surface of malachite showed a stronger hydrophobicity after interacting with HCMCX. Microflotation tests results exhibited that the recovery of malachite was about 94% when the pulp pH 8 and collector concentration at 200 mg/dm3. The results of practical ore flotation tests showed that HCMCX could as an excellent collector for flotation of fine malachite, finally to achieve the concentrates containing 20% Cu and 88% Cu recovery.
Źródło:
Physicochemical Problems of Mineral Processing; 2019, 55, 1; 58-69
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effects of heat treatment on the electrochemical properties and corrosion of aluminium alloy AA8011 in an aqueous acid media
Autorzy:
Kelechukwu, B. O.
Israel, O. O.
Emeka, E. O.
Ihebrodike, M. M.
Lebe, N.
Powiązania:
https://bibliotekanauki.pl/articles/412008.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Heat treatment
Electrochemical Measurement
Double layer capacitance
Mean defect size
Lattice distortion
Opis:
Effects of heat treatment and quenching regimen on the electrochemical corrosion behaviour of aluminium alloy AA8011 in 0.1M H2SO4 was studied by open circuit potential, potentiodynamic polarization and electrochemical impedance spectroscopy measurements. Three different specimens (untreated/ control, air -quenched oven- quenched) were investigated. Polarization results show that all the specimens underwent active dissolution, with no distinctive transition to passivation, heat treatment was observed to shift the corrosion potential towards low anodic values and decreased the rates of anodic partial reactions of the corrosion process. Electrochemical investigations reveal that heat treatment techniques have positive impacts on the alloy as indicated in increase in charge transfer resistance, polarization resistance and decrease in double layer capacitance. These positive effects are attributed to decrease in mean defect size and increase in lattice distortion of the crystallites in the heat treated specimens of the alloy. Studies of X-ray diffraction (XRD) spectra, scanning electron microscopy (SEM) morphologies of control, air and oven quenched samples of AA8011 aluminium alloy indicate decrease in mean defect size of 18.97 % and 40.44 %; increase in the lattice distortion of 11.07 % and 20.04 % for air and oven quenched specimens respectively.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 5; 17-31
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of digital image analysis for monitoring the behavior of factors that control the rock fragmentation in opencast bench blasting: a case study conducted over four opencast coal mines of the Talcher Coalfields, India
Autorzy:
Singh, Binay Kumar
Mondal, Debjeet
Shahid, Mohd
Saxena, Amit
Roy, Paresh Nath Singha
Powiązania:
https://bibliotekanauki.pl/articles/1839009.pdf
Data publikacji:
2019
Wydawca:
Główny Instytut Górnictwa
Tematy:
digital image analysis
rock fragmentation
bench blasting
mean fragment size
boulder percentage
cyfrowa analiza obrazu
fragmentacja skał
prace strzałowe
średnia wielkość fragmentu
Opis:
Drilling and blasting play a very important role in driving the economy of opencast mines, as various mining activities related to strata handling are dependent on the size of the rock mass created due to blasting. Thus the analysis of fragments created from rock explosion is essential in order to monitor its compatibility with the deployed mining machineries/HEMMs (such as shovel, dumper, dragline, etc.). As over fragmentation as well as under fragmentation both tend to increase the cost of mining, the generation of fragment size in the desired range is necessary. Several factors control the rock fragmentation in blasting, such as the burden, bench height/drilling depth, stemming column, powder factor and hole diameter. The assessment of rock fragmentation with respect to the aforementioned parameters helps to enhance the blast performance and, hence, this study intends to carry out digital image analysis for monitoring the mean fragment size and boulder percentage. A highly consistent result has been obtained using forty blasting datasets carried out in the four different opencast mines of the Talcher Coalfield (India), namely Balram OCP, Ananta OCP, Lakhanpur OCP, and Lajkura OCP.
Źródło:
Journal of Sustainable Mining; 2019, 18, 4; 247-256
2300-1364
2300-3960
Pojawia się w:
Journal of Sustainable Mining
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozprzestrzenianie się w powietrzu nanoobiektów wytwarzanych w wyniku włączenia kuchenki mikrofalowej
Spread of nano-objects in the air as a result of switching-on a microwave
Autorzy:
Jankowska, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/2164396.pdf
Data publikacji:
2016-06-17
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
nanoobiekty
rozprzestrzenianie się cząstek
kuchenka mikrofalowa
narażenie
stężenie liczbowe i powierzchniowe
średni wymiar cząstek
nano-objects
spread of the particles
microwave
exposure
number and surface concentrations
mean particle size
Opis:
Wstęp W wyniku włączenia w pomieszczeniu kuchenki mikrofalowej w powietrzu są wytwarzane cząstki o nanowymiarach. Wytwarzane cząstki mogą się rozprzestrzeniać w powietrzu w pomieszczeniu. Materiał i metody Badanie rozprzestrzeniania się cząstek w powietrzu w pomieszczeniu przeprowadzono przez określanie stężeń liczbowych i powierzchniowych oraz średnich wymiarów cząstek. Użyto do tego urządzeń DiscMini umiejscowionych w 6 punktach pomiarowych, pozwalających śledzić zmiany parametrów cząstek przede wszystkim w pobliżu źródła ich wytwarzania i w obszarze działania wentylacji miejscowej (dygestorium), a także w innych punktach, np. w pobliżu okna lub w środku pomieszczenia. Wyniki Kiedy dygestorium było wyłączone, tzn. w pomieszczeniu występowała wentylacja zrównoważona, włączenie kuchenki spowodowało 9,42–14,14-krotny wzrost stężeń liczbowych cząstek o nanowymiarach w odniesieniu do tła i 3,51–4,81-krotny wzrost stężeń powierzchniowych. Kiedy dygestorium było włączone, tzn. w pomieszczeniu występowało podciśnienie, włączenie kuchenki spowodowało 3,20–4,43-krotny wzrost stężeń liczbowych cząstek o nanowymiarach w odniesieniu do tła i 1,61–1,89-krotny wzrost stężeń powierzchniowych cząstek. Wnioski Z analizy danych wynika, że włączenie kuchenki mikrofalowej na 5 min skutkuje wytwarzaniem nanoobiektów po ok. 3 min od włączenia kuchenki, z maksymalnymi wartościami stężeń do 12 min od włączenia kuchenki, we wszystkich 6 punktach pomiarowych zlokalizowanych w badanym pomieszczeniu. Dotyczy to obydwu sytuacji, tzn. włączonego i wyłączonego dygestorium. Med. Pr. 2016;67(3):353–363
Background Switching-on a microwave results in the creation of nano-sized particles, which can spread through the air of a given premise, e.g., room. Material and Methods The study was carried out to determine the number and surface concentrations as well as the mean particles size using a DiscMini measurement device distributed in 6 measuring points to track changes of particle parameters, primarily at the source of particle creation and in the area of local ventilation (fume cupboard), and also in other places, e.g., near the window or in the middle of the room. Results Where the fume cupboard was switched-off, i.e., normal pressure ventilation in the room, switching-on the microwave caused a 9.42–14.14-fold increase in the number concentration of nano-sized particles relative to the background and a 3.51–4.81-fold increase in the surface concentration. Where the fume cupboard was switched-on, i.e., negative pressure ventilation in the room switching-on the microwave caused a 3.20–4.43-fold increase in the number concentration of nano-size particles relative to the background and a 1.61–1.89-fold increase in the surface concentration. Conclusions The analysis of the data shows that switching-on a microwave for 5 min results in the creation of nano-objects already after about 3 min with the maximum concentration values after 12 min since switching-on the microwave in all 6 measurement points distributed in the test room. This applies to both situations, i.e., when the fume cupboard was switchedoff or switched-on. Med Pr 2016;67(3):353–363
Źródło:
Medycyna Pracy; 2016, 67, 3; 353-363
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of sample size on estimation of bootstrap confidence intervals for mean
Wpływ liczebności próby na oszacowanie bootstrapowych przedziałów ufności dla średniej
Autorzy:
Bochniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/9587.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Katedra Zastosowań Matematyki i Informatyki
Tematy:
sample size
estimation
bootstrap
confidence interval
mean
normal distribution
Źródło:
Colloquium Biometricum; 2008, 38
1896-7701
Pojawia się w:
Colloquium Biometricum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effervescent atomization of glycerol aqueous solutions
Autorzy:
Broniarz-Press, L.
Ochowiak, M.
Włodarczyk, S.
Markuszewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/175506.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
spray
effervescent atomization
viscosity
drop size histogram
sauter mean diameter
Opis:
Paper presents the rheological characteristics of glycerol aqueous solutions and spray structures, droplets diameters, drop size histograms for effervescent atomizers. The study shows a nonlinear relation between the Sauter mean diameter and the gas to liquid mass flow ratio. By increasing the concentration of glycerol the solution viscosity tends also to increase. The experimental results show that the size of droplets depends on the liquid viscosity. The diameter of droplets increases with increase of liquid viscosity. Drops size histograms based on the number of drops showed the increase in number of large and the decrease in small droplets with increase of concentration of glycerol. Additionally, the characteristic stages of atomized liquid have been presented: the jet with built-in bubbles (slug flow), satellite bubbles and connected bubbles.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2013, 125; 29-38
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Introducing key advantages of intensified flotation cells over conventionally used mechanical and column cells
Autorzy:
Hassanzadeh, Ahmad
Safari, Mehdi
Khoshdast, Hamid
Güner, Mustafa K.
Hoang, Duong H.
Sambrook, Tim
Kowalczuk, Przemyslaw B.
Powiązania:
https://bibliotekanauki.pl/articles/2146874.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pneumatic flotation cells
energy input
mean particle retention time
fine particles
bubble size distribution
Opis:
The present paper introduces the key advantages of ImhoflotTM, JamesonTM, and RefluxTM flotation cells over the conventionally used mechanical and column cells from different perspectives. The impact of slurry mean retention time, bubble size distribution, and energy input was studied for all cell types. The mean retention time of laboratory scale ImhoflotTM (V030-cell) and RefluxTM flotation cells (RFC100) were measured experimentally using KCl as a tracer. Also, initially a statistical and practical overview of previously installed ImhoflotTM, and JamesonTM cells was presented in this work. It was found that more industrial data is available for the JamesonTM cell. The diagnostic results showed that RefluxTM, JamesonTM, and ImhoflotTM functionally operate similarly based on providing intensive turbulence in the downcomer. They were initially applied to the Australian and the UK coal industries and installed in the cleaning stage of flotation circuits, while there are now more applications in a wide variety of minerals across the world in different flotation stages. First pilot trials on a Russian gold ore were reported operating both JamesonTM and ImhoflotTM cells at the rougher-scalper and cleaner stages providing superior results using the ImhoflotTM cell as rougher-scalper and the JamesonTM at the cleaner. Formation of sub-micron and micron-sized bubbles, effective hydrodynamic characteristics, and low capital and operating costs were reported as major advantages of intensified flotation cells over the conventionally used ones in improving the recoverability of ultra-fine particles. Literature data showed that these cells provide greater gas-hold-up values (40-60%) over the mechanical (5-20%) and column cells (5-25%) with substantially lower power inputs. It was indicated that low mean slurry retention time could lead to a potential enhancement in their throughputs, but further industrial measurements are required to prove this statement. The RefluxTM cell showed a plug-flow mixing regime, while ImhoflotTM V-Cell followed the trend of perfect mixing and plug-flow dispersion regimes.
Źródło:
Physicochemical Problems of Mineral Processing; 2022, 58, 5; art. no. 155101
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An Approximation To The Optimal Subsample Allocation For Small Areas
Autorzy:
Molefe, W. B.
Shangodoyin, D. K.
Clark, R. G.
Powiązania:
https://bibliotekanauki.pl/articles/973548.pdf
Data publikacji:
2015
Wydawca:
Główny Urząd Statystyczny
Tematy:
composite estimation
mean squared error
sample design
small area estimation
sample size allocation
Taylor approximation
Opis:
This paper develops allocation methods for stratified sample surveys in which small area estimation is a priority. We assume stratified sampling with small areas as the strata. Similar to Longford (2006), we seek efficient allocation that minimizes a linear combination of the mean squared errors of composite small area estimators and of an estimator of the overall mean. Unlike Longford, we define mean-squared error in a model-assisted framework, allowing a more natural interpretation of results using an intra-class correlation parameter. This allocation has an analytical form for a special case, and has the unappealing property that some strata may be allocated no sample. We derive a Taylor approximation to the stratum sample sizes for small area estimation using composite estimation giving priority to both small area and national estimation.
Źródło:
Statistics in Transition new series; 2015, 16, 2; 163-182
1234-7655
Pojawia się w:
Statistics in Transition new series
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Two-stage cluster sampling with unequal probability sampling in the first stage and ranked set sampling in the second stage
Autorzy:
Ugwu, Michael C.
Madukaife, Mbanefo S.
Powiązania:
https://bibliotekanauki.pl/articles/2108165.pdf
Data publikacji:
2022-09-14
Wydawca:
Główny Urząd Statystyczny
Tematy:
cluster sampling
population mean estimator
probability proportional to size sampling
ranked set sampling
relative efficiency
Opis:
In this research work we introduce a new sampling design, namely a two-stage cluster sampling, where probability proportional to size with replacement is used in the first stage unit and ranked set sampling in the second in order to address the issue of marked variability in the sizes of population units concerned with first stage sampling. We obtained an unbiased estimator of the population mean and total, as well as the variance of the mean estimator. We calculated the relative efficiency of the new sampling design to the two-stage cluster sampling with simple random sampling in the first stage and ranked set sampling in the second stage. The results demonstrated that the new sampling design is more efficient than the competing design when a significant variation is observed in the first stage units.
Źródło:
Statistics in Transition new series; 2022, 23, 3; 199-214
1234-7655
Pojawia się w:
Statistics in Transition new series
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody poprawy efektywności procesu rozpylania w nebulizatorach pneumatycznych
Methods to improve the efficiency of atomization process in pneumatic nebulizers
Autorzy:
Matuszak, M.
Ochowiak, M.
Włodarczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/2073238.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rozpylanie
średnia średnica kropli
widmo rozpylenia
nebulizator
atomization
mean droplet diameter
droplet size distribution
nebulizer
Opis:
Omówiono metody poprawy efektywności procesu rozpylania w nebulizatorach pneumatycznych. Skupiono się na podniesieniu temperatury rozpylanej cieczy oraz dodatkowym napowietrzaniu cieczy w naczyńku nebulizacyjnym. Połączenie tych dwóch efektów w znaczący sposób przyczyniło się do zmniejszenia średniej średnicy kropli, a charakter aerozolu stał się bardziej monodyspersyjny. Ponadto określono wpływ objętościowego natężenia przepływu gazu na proces atomizacji.
The paper discusses methods to improve the efficiency of atomization process in pneumatic nebulizers. The studies were directed on increasing the temperature of sprayed liquid and additional aeration of liquid in the nebulizer cup. Combination of these two effects significantly contributes to the decrease of mean droplet diameter and simultaneously the character of aerosol becomes more monodisperse. In addition, the effect of gas volumetric flow rate on the atomization process was determined.
Źródło:
Inżynieria i Aparatura Chemiczna; 2017, 3; 90--91
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ lepkości cieczy na proces rozpylania w inhalatorach medycznych
Effect of viscosity on the atomization process in medical inhalers
Autorzy:
Broniarz-Press, L.
Ochowiak, M.
Markuszewska, M.
Włodarczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/2072505.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
inhalator
rozpylanie
widmo rozpylenia
lepkość
średnica Sautera
inhaler
atomization
viscosity
droplet size histogram
Sauter mean diameter
Opis:
W pracy przedstawiono wyniki badań rozpylania wody oraz wodnych roztworów gliceryny w inhalatorze medycznym. Przeprowadzono analizę wpływu lepkości na wielkość kropel, ich rozkłady ilościowe oraz średnią średnicę kropli. Stwierdzono, że lepkość w istotny sposób wpływa na wielkości zastępczej średnicy kropli. Wykazano także, że ze wzrostem stężenia gliceryny wzrasta udział kropel o większych średnicach, a widmo rozpylenia ulega rozszerzeniu.
Research results dealing with atomization of water and aqueous solutions of glycerol in a medical inhaler are presented in the paper. Analysis of influence of viscosity on the droplet size, droplet size histograms and mean droplet diameter was carried out. It was proved that viscosity affected significantly the droplet size diameter. For higher glycerol concentration, the fraction of droplets with a larger diameter increases and the droplet size histogram ii wider.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 4; 291--292
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ właściwości cieczy na rozpylanie w inhalatorach medycznych
Effect of liquid properties on the atomization in medical inhalers
Autorzy:
Broniarz-Press, L.
Matuszak, M.
Ochowiak, M.
Włodarczak, S.
Zajcher, A.
Powiązania:
https://bibliotekanauki.pl/articles/2072995.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
inhalator
lepkość
napięcie powierzchniowe
średnia średnica objętościowo-powierzchniowa
widmo rozpylenia
inhaler
viscosity
surface tension
drop size histogram
volume surface mean diameter
Opis:
W pracy przedstawiono wyniki badań rozpylania wodnych roztworów gliceryny o stężeniu 25÷70% wag. oraz alkoholu etylowego o stężeniu od 5% do 60% obj. w inhalatorach medycznych. Przedstawiono wyniki badań doświadczalnych i analizę wpływu lepkości, napięcia powierzchniowego oraz konstrukcji inhalatora na wielkość kropel, ich rozkłady liczbowe oraz średnią średnicę kropli. Wykazano, że zarówno lepkość, jak i napięcie powierzchniowe oraz konstrukcja rozpylacza w istotny sposób wpływają na wielkości zastępczej średnicy kropli.
The paper describes research results dealing with the atomization of glycerol aqueous solutions of concentration range of 25÷70% by mass and ethyl alcohol of concentration from 5% to 60% vol. in medical inhalers. The results of experimental studies and the analysis of effect of viscosity, surface tension and inhaler design on droplet size, droplet size histogram and mean droplet diameter are presented. It was shown that both viscosity and surface tension as well as atomizer design significantly affect the droplet size diameter.
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 4; 221--222
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies