Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Stacja Uzdatniania Wody" wg kryterium: Temat


Wyświetlanie 1-11 z 11
Tytuł:
Udział prac badawczych w rozwiązaniu problemu zaopatrzenia w wodę na przykładzie Obornik Wielkopolskich
On the role of research in the development of water supply systems: the water supply for Oborniki Wielkopolskie
Autorzy:
Kostrzewa, E.
Szrajber, Z.
Celmer, E.
Powiązania:
https://bibliotekanauki.pl/articles/237560.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
zaopatrzenie w wodę
stacja uzdatniania wody
ujęcia wody
Opis:
The paper presents a technological concept for the Water Treatment Plant of Oborniki Wielkopolskie and emphasizes the role of scientific investigations (model-scale, pilot-plant and full-scale) in solving the water supply problem - from the exploration of water sources to the monitoring of the water treatment process which parallelled the start-up of the treatment plant. The water treatment plant designed and constructed on the basis of the investigations mentioned not only provides the municipality with water of the quality desired, but also serves (in terms of both quantity and quality) local industrial users calling for high-quality water (e.g. food producers).
Źródło:
Ochrona Środowiska; 2001, 4; 45-46
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Doświadczenia z projektowania i wdrażania stacji uzdatniania wody kotłowej dla ENERGO-TECH sp. z o.o.
Experience from the design and Implementation of boiler water treatment installation for ENERGO-TECH Co. Ltd.
Autorzy:
Skoczko, I.
Powiązania:
https://bibliotekanauki.pl/articles/1819487.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
woda kotłowa
stacja uzdatniania wody
projektowanie
boiler water
water treatment plant
designing
Opis:
Przedmiotem niniejszej pracy jest podsumowanie rozważań dotyczących doboru optymalnego systemu uzdatniania wody kotłowej dla firmy ENERGO-TECH sp. z o.o., która jest dostawcą ciepła w postaci pary oraz zarządcą stacji uzdatniania wody dla dużej firmy włókienniczej ANDROPOL S.A.W ramach stażu naukowego finansowanego z unijnego projektu Kapitał Ludzki "Wzmocnienie potencjału kadr nauki i biznesu poprzez transfer wiedzy w regionie" w Katedrze Technologii w Inżynierii i Ochronie Środowiska Politechniki Białostockiej podjęto prace nad pro-jektem stacji uzdatniani wody kotłowej dla ENERGO-TECH sp. z o.o., która pozwoliłaby na odpowiednie oczyszczenie wody, a następnie wdrożeniem go w praktyce. Prace przygotowawcze stanowiły szereg analiz wody surowej oraz wody po wstępnym napowietrzeniu. Analizowanymi parametrami były wskaźniki powszechnie stosowane w analizie wody. Przedstawiono je w tabeli 1. Otrzymane wyniki stanowiły średnią z trzech niezależnych pomiarów wykonanych z dostarczonej wody do badań.
The subject of this paper is a summary of considerations for selecting the optimum system for boiler water treatment installation for ENERGO-TECH Co. Ltd., which is a supplier of heat in the form of steam and water treatment plant manager for a large textile company Andropol SA. The water treatment plant functioning up to now was equipped with an open aeration chamber. On its bottom the perforated pipes with bored holes were placed. It was not suitable water treatment for high-pressure boilers. Used technology allowed to decrease turbidity in the water, suspensions, and partly iron and manganese contents. As part of this project and based on previously obtained results of raw water, 3 sand filters and 6 ion-exchange filters filled with a cation bed Purolite 100E were designed for proper preparation of water for boilers. A satisfactory degree of removal of iron, color, turbidity, ammonia nitrogen and oxidability were not obtained as a result of the used processes. Therefore, the following additional processes were considered: coagulation, preoxidation using hydrogen peroxide and sorption, before ion exchange. The effectiveness of these methods was examined in the laboratory. Sorption with activated carbon has proved the most effective of the three selected processes. There is a danger that the purified water in the way described in this study may reveal the corrosion properties, which in future may lead to the destruction of the walls of boilers. The proposed installation should include ion exchangers - anion exchangers, which allow a complete demineralization and deacidification of purified water, to prevent the destruction of the boilers.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1731-1742
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie zmian zużycia energii elektrycznej do oceny stanu stacji uzdatniania wody
The use of changes in electricity consumption to assess the condition of the Water Treatment Plant
Autorzy:
Erd, A.
Jankowski, D.
Powiązania:
https://bibliotekanauki.pl/articles/315143.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
energochłonność
efektywność
stacja uzdatniania wody
transport wody
electricity consumption
efficiency
water treatment plant
water transport
Opis:
W artykule omówiono wykorzystanie utworzonego dobowego wskaźnika energochłonności do oceny efektywności pracy agregatów głębinowych oraz stanu technicznego stacji uzdatniania wody.
The article discusses the use of the daily diurnal energy intensity index to assess the efficiency of deepwater aggregates and the technical condition of the water treatment station.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 12; 399-402
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka problemów eksploatacji suw czaniec w latach 2009-2010
Characteristic of operating difficulties of wtp czaniec in the year 2009-2010
Autorzy:
Zimoch, I.
Kotlarczyk, B.
Nadolska, K.
Powiązania:
https://bibliotekanauki.pl/articles/399953.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
koagulacja
stacja uzdatniania wody
mętność
uboczne produkty dezynfekcji
coagulation
water treatment plant
turbidity
disinfection by-products
Opis:
SUW Czaniec opiera swą produkcję na zasobach wód górskich pobieranych ze zbiornika Czaniec, charakteryzujących się intensywną zmianą jakości w czasie ulew i topnienia śniegu. Spływy powierzchniowe, jaki i zwiększenie przepływu w korytach rzek i potoków skutkują napływem ładunku zanieczyszczeń do zbiornika w Czańcu, co powoduje takie zwiększenie mętności i barwy, iż układ technologiczny uzdatniania wody nie jest w stanie zatrzymać zanieczyszczeń w wymaganym stopniu. Zjawiska gwałtownych zmian jakości wody w źródle, nabrały w ostatnich latach na sile, czego bezpośrednim efektem są wymuszone postoje technologiczne SUW Czaniec. W artykule przedstawiono pełną charakterystykę warunków technologicznych eksploatacji SUW w zmiennych okolicznościach produkcji wody. Integralnym elementem opracowania jest ocena efektów technologicznych wraz z analizą ekonomiczną eksploatacji stacji.
Water production of WTP Czaniec is based on mountain water resources. The water intake is located at the Czaniec reservoir. During downpour and snow's melting raw water has intensive changed of quality. Increase of water colour and turbidity in Czaniec reservoir have resulted from the flood run-off in river- bed and stream as well as earth flow, hence in the technological system of water treatment arises difficulties of correct water purification. Te effect of rapid water changes in source increases at last year, witch are direct results of forced shutdowns of water production of WTP Czaniec. The article presents a full characterization of the technological conditions of service at varying circumstances WTP water production. An integral element of the study is to assess the effects of technology along with the economical analysis of the WTP operating.
Źródło:
Inżynieria Ekologiczna; 2011, 26; 257-268
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczne aspekty eksploatacji stacji uzdatniania wody na przykładzie SUW Wierzchowo
Practical aspects of operating a water treatment plant on the example WTP Wierzchowo
Autorzy:
Juraszka, B.
Braun, S.
Powiązania:
https://bibliotekanauki.pl/articles/1819536.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
uzdatnianie wody
gospodarka wodno-ściekowa
stacja uzdatniania wody Wierzchowo
water treatment
water and sewage
water treatment plant in Wierzchowo
Opis:
Zaopatrzenie ludności w wodę pitną jest jednym z podstawowych zadań jednostek samorządu terytorialnego. Obowiązek ten realizowany jest poprzez system ujęć, zakładów uzdatniania wody i sieci dystrybucji. Jednostki które zarządzają tą infrastrukturą w imieniu gmin, są zobowiązane do utrzymywania należytej jakości wody pitnej oraz wysokiego stopnia pewności dostawy. W ostatnich latach daje się zauważyć znaczny wzrost nakładów ponoszonych na uporządkowanie gospodarki wodno-ściekowej, w tym systemów uzdatniania wody. Zakres działań obejmuje modernizację przestarzałych technicznie, wyeksploatowanych układów i za automatyzację procesów produkcji wody w takim zakresie aby zoptymalizować pracę stacji i do minimum ograniczyć zaangażowanie obsługi technicznej w konserwację obiektu. Z uwagi na duże nakłady inwestycyjne i wymagane kompetencje obsługi, tego typu instalacje nie są rozpowszechnione na małych wiejskich stacjach. Dlatego też takie obiekty paradoksalnie wymagają ze strony użytkownika większego zaangażowania w utrzymanie ruchu. W treści artykułu zwrócono uwagę na kilka istotnych procesów decydujących o sprawności układu uzdatniania wody. Na etapie projektu modernizacji SUW, przy uszczegóławianiu rozwiązań technicznych nie zostały one uwzględnione, co zaowocowało istotnym ograniczeniem skuteczności uzdatniania, a w konsekwencji doprowadziłyby do nieodwracalnego zbrylenia złoża. Praca ma na celu wykazanie, że zaprojektowanie technologii wody pitnej musi polegać na szczegółowej analizie wszystkich jej elementów.
The need for modernization of small rural water supplies requires a careful approach to the analysis of water demand. Changes in the structure of rural areas causes a change in trends in the characteristics of water consumption, so the requirements for systems of water treatment and distribution should be closely verified. Observations made during start and first period of operation of WTP allow to make an objective assessment of technological water treatment system. One of essential factors for its operation is efficient aeration of raw water. The solution in the form of a classical mixing water and air with aeration grid and fill in this case did not bring the expected results. Scope of the study does not allow assessment of raw water in terms of solubility of gases, the practical experience gained from other plants suggest a solution. Good effects of aeration can be achieved using socalled static mixer mounted on the pipeline before the mixing device - in this case operating as a reaction tank. Proper venting of the system should be provided by automatic vent system duplicated by manually controlled valves. This allows control and eventual hassle-free operation during the filtration. Another element that has to be noted is the proper selection of the size of submersible pump and filters. Due to the small daily consumption and application of water storage tank for its fulfilment, seek to extend the working time of filters by using submersible pump with lower performance than the originally installed is needed. This will reduce the filtration rate and reduce the switching frequency of the pump, which will benefit the quality of produced water. Raw water from intake was used for rinsing the filters, but the performance of submersible pump is too small to provide sufficient expansion of the bed. Therefore, it is recommended to use an independent rinsing pump used only for the regeneration of filters, and fed from a storage tank. Its work in conjunction with flushing air blower will allow effective regeneration. Capturing possible shortcomings in this area will allow only installation of measurement armature and periodic evaluation of condition and possible loss of deposit. Modifications of not properly selected technology in the stage of realized object is difficult and expensive, and therefore during design stage particular attention should be paid to pilot research and a detailed analysis of introduced technical solutions.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 973-988
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa sztolni pod masywem góry Chmielnik w Jeleniej Górze - Cieplicach
Construction of a drift under the Chmielnik Mountain in Jelenia Góra - Cieplice
Autorzy:
Zynek, J.
Antosz, A.
Powiązania:
https://bibliotekanauki.pl/articles/349751.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Góra Chmielnik
sztolnia
PeBeKa SA
stacja uzdatniania wody w Jeleniej Górze
budowa sztolni metodą strzelniczą
Chmielnik Hill
drift
tunnels
water treatment station in Jelenia Góra
driving with drill and blast method
Opis:
Artykuł przedstawia etapy budowy sztolni pod masywem góry Chmielnik z opisem technologii wykonania, warunków naturalnych górotworu i zasad drążenia tuneli metodą strzałową. Przedstawiono powody wykonania elementów nieprzewidzianych w pierwotnej dokumentacji technicznej, a koniecznych dla bezpiecznej pracy obiektu. Ze względu na trudne warunki lokalne sztolnia na całej długości została wykonana w obudowie klasy portalowej. Opracowanie stanowi zbiór najistotniejszych wiadomości teoretycznych i doświadczenia wykonawcy robót zapewniającego jakościowe, terminowe i bezpieczne prowadzenie prac. Wybudowana sztolnia służy do przeprowadzenia rurociągów wody uzdatnionej ze Stacji Uzdatniania Wody z jednej strony góry Chmielnik na drugą stronę do zbiorników zapasowo-wyrównawczych.
The paper presents all stages of tunnel (drift) construction underneath Chmielnik mountain massif near Jelenia Góra city. Detailed descriptions of execution techniques, natural rock mass conditions and principles of drivting with drill and blast method are presented in it. Reasons for execution of elements which were not predicted in primary documentation but were necessary for the safety operation of the object were also presented. Due to very difficult local rock conditions, the whole tunnel was supported with lining of portal type. The paper consists a set of the most significant theoretical knowledge and experience of the contractor, who have provided safety execution the work with proper quality and within scheduled time. Excavated tunnel serves for water pipelines conduct treated water from water treatment station on one side of Chmielnik Hill to retention/reserve reservoirs on the other side.
Źródło:
Górnictwo i Geoinżynieria; 2007, 31, 3; 489-497
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza kosztów stacji uzdatniania wód powierzchniowych w Polsce
Autorzy:
Miłaszewski, Rafał
Panasiuk, Damian
Powiązania:
https://bibliotekanauki.pl/articles/583753.pdf
Data publikacji:
2017
Wydawca:
Wydawnictwo Uniwersytetu Ekonomicznego we Wrocławiu
Tematy:
stacja uzdatniania wód
wody powierzchniowe
analiza kosztów
efektywność ekonomiczna
Opis:
Analiza jednostkowych kosztów inwestycyjnych i eksploatacyjnych stacji uzdatniania wód powierzchniowych pokazuje, że koszty te maleją wraz z wydajnością stacji. Wyższe koszty występują dla stacji pobierających wody kategorii A2 i A3, a niższe pobierające wodę kategorii A1. Jednostkowe koszty inwestycyjne stacji uzdatniania wód powierzchniowych są wielokrotnie wyższe niż w przypadku stacji uzdatniania wód podziemnych. Jednostkowe koszty eksploatacyjne stacji uzdatniania wód powierzchniowych są natomiast nieznacznie niższe niż w stacjach uzdatniania wód podziemnych stosujących procesy fizyczno-chemiczne. Analiza struktury kosztów pokazała, że amortyzacja i zużycie energii są dominującymi składnikami kosztów stacji uzdatniania wód powierzchniowych. Kolejne miejsca zajmują wynagrodzenia oraz zużycie materiałów, a koszty remontów zależą od stanu technicznego stacji.
Źródło:
Prace Naukowe Uniwersytetu Ekonomicznego we Wrocławiu; 2017, 491; 284-293
1899-3192
Pojawia się w:
Prace Naukowe Uniwersytetu Ekonomicznego we Wrocławiu
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja stacji uzdatniania wód podziemnych "Letniki" koło Elbląga
Retrofit of the Letniki groundwater treatment plant near Elbląg
Autorzy:
Olańczuk-Neyman, K.
Bray, R.
Powiązania:
https://bibliotekanauki.pl/articles/237730.pdf
Data publikacji:
2001
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody podziemne
stacja uzdatniania wód
jakość wód
prace modernizacyjne
Opis:
The object under study was retrofitted in the late 1990s with the aim to upgrade the quality of the water sent to the distribution system in general, and the removal efficiency for iron, manganese and ammonia nitrogen in particular. The taken-in water, which comes predominantly from the Quaternary aquifer, is classified as "hard water" because of the high concentrations of iron, manganese and ammonium nitrogen (5.0 gFe/m[3], 1.5 gMn/m[3] and 2.0 gN/m[3]). The water treatment train made use of prior to the retrofit (which included aeration and single-stage filtration) yielded only iron removal to the level of about 0.3 gFe/m[3]; the concentrations of the other investigated compounds still exceeded considerably the admissible values, as they ranged from 0.5 to 1.0 gMn/m[3] and from 0.9 to 2.0 gN/m[3]. Following analysis of the pilot-plant results, an additional filtration stage, which involved a mature high-silica sand bed, was proposed. The retrofit of the treatment plant brought about a noticeable improvement of water quality. The concentrations of iron, manganese and ammonia nitrogen in the treated water amounted to 0.2 gFe/m[3], 0.05 gMn/m[3] and 0.2 gN/m[3], respectively. However owing to the incomplete separation of the tanks and to the distribution of mixed water (after the first and second stage of filtration), the concentration of manganese in the tap water slightly exceeds the admissible values.
Źródło:
Ochrona Środowiska; 2001, 3; 21-24
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gospodarka osadowa w Naukowo Badawczej Stacji Wodociągowej Szkoły Głównej Gospodarstwa Wiejskiego
Sedimentary management in the Scientific and Research Water Treatment Station of Warsaw Agricultural University
Autorzy:
Wichowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/886162.pdf
Data publikacji:
2006
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
stacje uzdatniania wody
SGGW Warszawa
Naukowo-Badawcza Stacja Wodociagowa
uzdatnianie wody
woda
popluczyny
osady
gospodarka osadami
Źródło:
Scientific Review Engineering and Environmental Sciences; 2006, 15, 2[34]
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Naukowo-Badawcza Stacja Wodociągowa SGGW ma już 35 lat
Scientific Research Water Treatment Plant of the Agricultural University in Warsaw already has 35 years
Autorzy:
Kalenik, M.
Morawski, D.
Powiązania:
https://bibliotekanauki.pl/articles/886164.pdf
Data publikacji:
2010
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
Naukowo-Badawcza Stacja Wodociagowa
eksploatacja wod
inzynieria srodowiska
uzdatnianie wody
woda
SGGW Warszawa
jubileusz
stacje uzdatniania wody
ciagi technologiczne
Opis:
In the article was presented history of Scientific Research Water Treatment Plant of the Agricultural University in Warsaw. Construction and the principles of operation of the two technological lines treatments raw water taken away of bored wells with formations Quaternary and Tertiary were described. Results of conducted experimental research and acquired experience during exploitation of technical appliances uses being in this object was presented.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2010, 19, 2[48]
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies