Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "phasor measurement unit (PMU)" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Measurement accuracy verification of phasor measurement unit with dynamic phasor estimation
Autorzy:
Arendarski, B.
Rabe, S.
Heineken, W.
Komarnicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/140719.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
discrete Fourier transform (DFT)
dynamic phasor
measurement accuracy
phasor measurement unit (PMU)
power system
Opis:
Power systems that are highly loaded, especially by a stochastic supply of renew- ables and the presence of storages, require dynamic measurements for their optimal control. Phasor measurement units (PMUs) can be used to capture electrical parameters of a power system. Standards on the PMU dynamic performance have been modified to incorporate their new dynamic mode of operation. This paper examines the PMU dynamic performance and proposes essential algorithms for measurement accuracy verification. Measurements of dynamic input signals, which vary in amplitude or frequency, were taken during au- tomated tests of two PMUs. The test results are presented and expounded with further recommendation for the performance requirements. This paper also presents and examines applied testing procedures with relevance to the specifications of the IEEE Standard for Synchrophasor C37.118.1™-2011 and its amendment C37.118.1a™-2014.
Źródło:
Archives of Electrical Engineering; 2018, 67, 3; 529--543
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A review of the importance of synchrophasor technology, smart grid, and applications
Autorzy:
Baba, Maveeya
Nor, Nursyarizal B.M.
Sheikh, Aman
Nowakowski, Grzegorz
Masood, Faisal
Rehman, Masood
Irfan, Muhammad
Arefin, Ahmed Amirul
Kumar, Rahul
Baba, A. Momin
Powiązania:
https://bibliotekanauki.pl/articles/2173713.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phasor measurement unit
PMU
micro-PMU
Global Positioning System
GPS
optimal PMU placement
smart grid
SG
jednostka pomiaru fazorów
mikro-PMU
globalny system pozycjonowania
optymalne rozmieszczenie PMU
sieć inteligentna
Opis:
The electrical network is a man-made complex network that makes it difficult to monitor and control the power system with traditional monitoring devices. Traditional devices have some limitations in real-time synchronization monitoring which leads to unwanted behavior and causes new challenges in the operation and control of the power systems. A Phasor measurement unit (PMU) is an advanced metering device that provides an accurate real-time and synchronized measurement of the voltage and current waveforms of the buses in which the PMU devices are directly connected in the grid station. The device is connected to the busbars of the power grid in the electrical distribution and transmission systems and provides time-synchronized measurement with the help of the Global Positioning System (GPS). However, the implementation and maintenance cost of the device is not bearable for the electrical utilities. Therefore, in recent work, many optimization approaches have been developed to overcome optimal placement of PMU problems to reduce the overall cost by providing complete electrical network observability with a minimal number of PMUs. This research paper reviews the importance of PMU for the modern electrical power system, the architecture of PMU, the differences between PMU, micro-PMU, SCADA, and smart grid (SG) relation with PMU, the sinusoidal waveform, and its phasor representation, and finally a list of PMU applications. The applications of PMU are widely involved in the operation of power systems ranging from power system control and monitor, distribution grid control, load shedding control and analyses, and state estimation which shows the importance of PMU for the modern world.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 6; art. no. e143826
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solving the problem of distribution network observability with smart meters
Rozwiązanie problemu obserwowalności sieci rozdzielczej za pomocą liczników inteligentnych
Autorzy:
Golub, I. I.
Kuzkina, Y. I.
Powiązania:
https://bibliotekanauki.pl/articles/397248.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
observability
distribution network
Phasor Measurement Unit
smart meter
Advanced Metering Infrastructure
obserwowalność
sieć rozdzielcza
jednostka pomiarowa PMU
licznik inteligentny
zaawansowana infrastruktura pomiarowa
Opis:
The paper is concerned with the problem of choice of the minimum number of smart meters to ensure either the observability of all state variables in distribution network or the observability of voltage magnitudes whose control is particularly important in the low voltage distribution networks with distributed generation. Currently only voltage magnitudes, active and reactive currents can be synchronized. It is shown that replacement of voltage phasor measurements with the measurements of voltage magnitudes alone makes it possible to provide observability of voltage magnitudes at all feeder nodes with the number of smart meters lower than the number of load nodes.
Artykuł dotyczy problemu wyboru minimalnej liczby liczników inteligentnych, wystarczającej do zapewnienia obserwowalności wszystkich zmiennych stanu sieci rozdzielczej lub wartości napięcia, którego regulacja jest szczególnie ważna w sieciach rozdzielczych niskiego napięcia z generacją rozproszoną. Pokazano, że samo zastąpienie pomiarów fazorów napięcia pomiarami wartości amplitudy napięcia umożliwia zapewnienie obserwowalności wartości amplitudy napięcia we wszystkich węzłach zasilających przy liczbie liczników inteligentnych mniejszej niż liczba węzłów odbiorczych.
Źródło:
Acta Energetica; 2017, 4; 4-9
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies