Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "iniekcja" wg kryterium: Temat


Wyświetlanie 1-10 z 10
Tytuł:
New reconstruction technologies of safety pillar in mines
Nowoczesne technologie odbudowy filara bezpieczeństwa w kopalniach
Autorzy:
Gonet, A.
Stryczek, S.
Brudnik, K.
Powiązania:
https://bibliotekanauki.pl/articles/219285.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
filar bezpieczeństwa
kopalnia
iniekcja otworowa
iniekcja rurociągowa
safety pillar
mine
pipeline injection
hole injection
Opis:
Safety pillars are made around mines as a protection measure. This is especially important in salt mines where the surrounding waters are most hazardous. Without maintaining safe conditions the mine may be water-flooded as it was the case in one of the Polish mine “Wapno“. An original technology linking pipeline injection and hole injection methods has been used for the reconstruction of a safety pillar in the Salt Mine “Wieliczka“. This solution turned out to be successful when on 13 April 1992 the mine was saved from flooding after a disastrous water flux to the transverse working Mina. The presented technology can be efficiently used in various mines at the stage of designing, though their exploitation to the closing stage.
Dla zapewnienia bezpieczeństwa wokół każdej kopalni należy utworzyć filar ochronny. Szczególnie jest to istotne w kopalniach soli, dla których otaczająca je woda jest największym zagrożeniem. Nie zachowanie odpowiednich warunków może się skończyć nawet zatopieniem kopalni, co miało miejsce nawet w Polsce - Kopalnia „Wapno”. W pracy opisano oryginalną technologię iniekcji rurociągowej połączoną z iniekcją otworową zastosowaną do odbudowy filara ochronnego w Kopalni Soli „Wieliczka”, która pozwoliła ją uratować przed zatopieniem po katastrofalnym dopływie wody, który wystąpił 13 kwietnia 1992 roku w poprzeczni Mina. Przedstawiona technologia może być z powodzeniem zastosowana w różnych kopalniach i to na etapie od ich budowy, poprzez czas eksploatacji aż na etapie likwidacji kończąc.
Źródło:
Archives of Mining Sciences; 2012, 57, 2; 403-412
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Injection simulation for the mold process in the medical industry
Autorzy:
Białasz, Sebastian
Powiązania:
https://bibliotekanauki.pl/articles/117683.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
simulation
injection
mold
medical industry
symulacja
iniekcja
pleśń
przemysł medyczny
Opis:
This paper presents information on the methods of construction and selection of materials, for the manufacturing of a medical device – a syringe filter. The main scope of the research was numerical simulation made in order to optimize the injection process. This simulation comprised of two parts: the first in which the chosen optimal number and position of injection points on the surface, and a second with the chosen optimum wall thickness, using a pre-selected injection points.
Źródło:
Applied Computer Science; 2018, 14, 3; 54-68
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of fracture-matrix interaction on thermal front movement in fractured reservoir
Autorzy:
Siemek, J.
Stopa, J.
Powiązania:
https://bibliotekanauki.pl/articles/200486.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
geothermal reservoir
reinjection
thermal front movement
zbiornik geotermalny
powtórna iniekcja
ruch termiczny
Opis:
Commercial exploitation of geothermal resources requires the disposal of large volumes of cooled brine in an environmentally acceptable way. Reinjection of cooled (i.e. spent) geothermal water has become a standard reservoir management strategy. Since injected fluids are typically much colder than the reservoir rock, this strategy results in the cooling of the region around the injection wells. Injected cool water may not have sufficient residence time in the reservoir to receive enough heat from surrounding hotter rock, resulting in temperature decrease at producing wells. Usually, the energy transport in geothermal reservoirs is calculated by use of sophisticated numerical simulators. In this paper we present analytical solution of simplified model of mass and heat transfer in fractured porous medium in one dimension, assuming constant rock temperature and neglecting small-scale effect connected with dispersion and heat conduction. The solution presented in this paper is applicable if thermal capacity of rock is high but the specific area is not sufficient for instant thermal equilibrium. This approach allows for better understanding the relation between fluid movement along the fractures and heat transfer between the rock matrix and fluid. Simple numerical experiments reported in the paper have shown the importance of specific surface area of naturally fractured rock, which influences the rate of exchange of heat between the fractures and the rock matrix.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 4; 965-969
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A laboratory study of the soil around injection-expanded wells: physical and mechanical characteristics changes
Autorzy:
Ihnatov, Siergey V.
Powiązania:
https://bibliotekanauki.pl/articles/31342628.pdf
Data publikacji:
2022
Wydawca:
Politechnika Częstochowska
Tematy:
iniekcja
zmiana charakterystyki gruntu
zaprawa cementowa
wzmocnienie gruntu
injection
ground characteristic change
cement mortar
ground strengthening
Opis:
The article is devoted to the description of the physical processes occurring in the soil when cement mortar is injected into the ground under pressure. The paper determines the reason for the lack of knowledge of such kinds of changes in the soil’s physical and mechanical properties around a well expanded by the injection. The article presents the author’s own results in the variability of the physical and mechanical properties of the soil during ground hardening by the injection, in time and in orientation. The differences over time in sand and clay characteristics are also presented.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2022, 11; 137-145
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the barrette load investigation of the tallest building in European Union
Analiza badania obciążania baret najwyższego budynku w Unii Europejskiej
Autorzy:
Kacprzak, G.
Bodus, S.
Powiązania:
https://bibliotekanauki.pl/articles/230297.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
fundament płytowo-palowy
bareta
iniekcja podstawy
ekstensometr
budynek wysokościowy
piled raft foundation
barrette
base injection
extensometer
high-rise building
Opis:
The paper presents a static load test of a pile with the largest vertical load in Poland to-date up to the force of 23000 kN. The test was performed in the centre of Warsaw on the construction site of a future high-rise building to be the tallest building in European Union. The designed building height measured from the ground level is 310 meters including an 80-metre mast. The foundation of the building was designed as a Combined Piled Raft Foundation (CPRF) utilising the barrettes and diaphragm walls technology. A 3.6 m thick slab was designed under the high-rise part, 1.5 and 2.5 metre thick outside of the high-rise part. The designed barrettes with cross-sections of 0.8 x 2.8m and length of 17.5 m and 20.0 m in the high-rise part have been injected. The test was carried out on barrettes with lengths of approx. 28 and 34 m and was aimed to estimate the stiffness (load-settlement relation) of the designed 17.5 metre-long barrette situated below the foundation level. In the first 10 meters the ground was disturbed in order to weaken the pile skin reaction. In addition to that a series of extensometric sensors was placed inside the barrette to determine the distribution of the axial force. The results served as a basis for the adoption of correct soil parameters in the numerical 3D model used for barrette testing and then for the calibration of an entire underground model of the designed building. The final aim of the designer was to determine the stiffness of the subsoil under the foundation slab and the stiffness of barrettes in the piled-raft system of the designed building.
Artykuł przedstawia próbne badanie statyczne pala przy jak do tej pory największym obciążeniu pionowym w Polsce do siły rzędu 23000kN. Badanie zostało wykonane w centrum Warszawy, na terenie przyszłego budynku wysokościowego mającego być najwyższym budynkiem w Europie. Zakładana wysokość budynku licząc od poziomu terenu to 310 metrów z uwzględnieniem 80-cio metrowego masztu. Fundament budynku został zaprojektowany jako posadowienie płytowopalowe w technologii baret i ścian szczelinowych. Zaprojektowano płytę o grubości 3.6m pod częścią wysokościową oraz poza obrysem części wysokościowej o grubości 1.5m i 2.5m. Projektowane barety o przekroju 0.8x2.8m i długości 17.5m i 20.0m w części wysokościowej zostały zainiektowane. Badanie wykonane było na baretach o długości około 28m i 34m, i miało na celu oszacowanie sztywności (relacja obciążenie-osiadanie) docelowo projektowanej barety o długości 17.5m poniżej poziomu posadowienia fundamentu. Na pierwszych 10-ciu metrach grunt został naruszony w celu osłabienia pracy pobocznicy. Dodatkowo wewnątrz barety został umieszczony ciąg czujników ekstensometrycznych do wyznaczenia przebiegu siły osiowej. Wyniki stanowiły bazę do przyjęcia poprawnych parametrów gruntowych w numerycznym modelu 3D służącym do testowania baret, a następnie do kalibracji pełnego modelu podziemia projektowanego budynku. Celem końcowym projektanta było wyznaczenie sztywności podłoża pod płytą fundamentową oraz baret pracujących w układzie płytowo-palowym projektowanego budynku.
Źródło:
Archives of Civil Engineering; 2018, 64, 4/I; 281-292
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault injection stress strategies in dependability analysis
Autorzy:
Sosnowski, J.
Gawkowski, P.
Lesiak, A.
Powiązania:
https://bibliotekanauki.pl/articles/970437.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
iniekcja błędów
modelowanie błędów
oszacowanie detekcji i tolerancji błędów
fault injection
fault modeling
test coverage
fault detection and fault tolerance evaluation
Opis:
The paper deals with the problem of testing computer system's susceptibility to hardware faults by means of software implemented fault injectors. Basing on our experience with fault injection techniques we present various strategies of fault stressing in relevance to fault impact analysis in the function of the application input data profile, fault injection profile in time and space, resource activities etc. We discuss the problem of test result qualification and significance. Fault hardening at the software level is also outlined. The considerations presented are illustrated with numerous experimental results obtained in Windows and Linux environments.
Źródło:
Control and Cybernetics; 2004, 33, 4; 679-699
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Construction solutions for historical object foundations in the context of changing their functional use
Rozwiązania konstrukcyjne posadowień obiektów zabytkowych w kontekście zmiany ich funkcji użytkowej
Autorzy:
Gwizdała, K.
Florkowska, S.
Powiązania:
https://bibliotekanauki.pl/articles/396522.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
historical objects
renovation
changing functional of use
reinforcement of foundations
jet grouting
obiekty zabytkowe
renowacja
zmiana funkcji użytkowej
wzmacnianie fundamentów
iniekcja strumieniowa
Opis:
Properly executed renovation and adaptation of a grade listed property not only ensures its constructional safety, but may also highlight the object’s historical value. Taking into consideration various factors, such as divergence of interests, or technical and legal determinants, it is safe to say that the renovation and adaptation of grade listed properties for new purposes is a complex process. The authors of the paper wish to discuss the problem of renovation based on selected properties, with special regard to constructional solutions for foundations. The presented examples will illustrate the issue of foundation enhancements resulting from the adaptation of buildings for new purposes. Through individual constructional solutions, such as jet grouting, it was possible to ensure the stability of degraded properties and safe transfer of increased values of usage load.
Prawidłowo przeprowadzona renowacja i adaptacja obiektu zabytkowego powinna zapewnić bezpieczeństwo konstrukcji, a jednocześnie podkreślić jego historyczną formę i wartość. Niejednokrotnie wybór rozwiązania konstrukcyjnego bywa kłopotliwy, ze względu na rozbieżność interesów inżyniera, konserwatora i inwestora. Biorąc pod uwagę uwarunkowania techniczne, funkcjonalne oraz prawne, realizacja prac związanych z renowacją i adaptacją obiektów zabytkowych ma charakter złożony. Decyzja o renowacji bądź wymianie wybranych elementów konstrukcyjnych w każdym przypadku powinna być poprzedzona kompleksową analizą techniczną oraz uzgodnieniami konserwatorskimi. Autorzy referatu omówili problematykę i aspekty renowacji w wybranych obiektach zabytkowych, ze szczególnym uwzględnieniem rozwiązań konstrukcyjnych fundamentów. Przedstawiono wzmocnienia posadowień obiektów wynikające ze zmiany ich funkcji użytkowej. W omawianych przypadkach przyjęto rozwiązania w postaci wprowadzenia nowych elementów konstrukcyjnych oraz wzmocnienia istniejących fundamentów przy użyciu technologii iniekcji strumieniowej. Dzięki przyjętym rozwiązaniom udało się zapewnić stabilność zdegradowanych dotąd obiektów oraz bezpieczne przeniesienie zwiększonych wartości obciążeń użytkowych, jak również ograniczyć nadmierne osiadania obiektu.
Źródło:
Civil and Environmental Engineering Reports; 2015, 19; 31-39
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of backfilling material using fly ash by application of chemical injection
Podawanie materiału podsadzkowego z popiołów lotnych z iniekcją chemiczną
Autorzy:
Shimada, H.
Yoshida, Y.
Senda, T.
Maeda, Y.
Sasaoka, T.
Fujita, S.
Matsui, K.
Watanabe, D.
Powiązania:
https://bibliotekanauki.pl/articles/970949.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
lubricant
backfilling
deep strata
pipe jacking
fly ash utilization
chemical injection
smar
podsadzka
głębokie warstwy
mocowanie rurociągu
utylizacja popiołów lotnych
iniekcja chemiczna
Opis:
Lubrication can effectively reduce the needed thrust if a discrete layer of lubricant is maintained between a pipe and the excavated soil. A lower frictional force allows greater jacking lengths to be achieved. The reduction of frictional stress around the pipe strongly affects the efficiency of lubrication injection. The lubricant must be designed to form a layer in the surrounding soil, be pressurized to overcome ground water pressure and stabilize the over-cutting area. The lubricant should also fill the over-cutting area completely to minimize surface settlement. However, for a commercial lubricant to be effective, it has been suggested that ingredients such as sodium and potassium be eliminated. As a result, in order that a lubricant does not lose its function as a support against the overburden pressure of an over-cutting area and to enable a reduction in thrust, a higher quality lubricant which can overcome these problems must be developed as soon as possible. In this paper, in order to examine the characteristics and behaviour of a material developed as a lubricant and backfilling for a deeper strata excavation system such as a pipe jacking, a fundamental investigation is performed and the various results are discussed.
Smarowanie może skutecznie zmniejszyć wymagany nacisk jeśli warstwa smaru jest utrzymana pomiędzy rurą a urobkiem. Niższa siła tarcia pozwala na osiągnięcie większych długości podczas mikrotunelingu. Redukcja naprężeń wokół rury silnie wpływa na efektywność wprowadzania smaru. Smar musi być zaprojektowany w taki sposób, aby tworzyć warstwę w otaczającej glebie, musi być wtłaczany pod ciśnieniem aby pokonać nacisk wód gruntowych oraz stabilizować drążoną powierzchnię. Smar powinien również wypełniać drążoną powierzchnię aby całkowicie zminimalizować osiadanie powierzchni. Jednakże, aby smar komercyjny był efektywny zdecydowano się na eliminację takich składników jak sód czy potas. W efekcie, aby smar nie stracił swojej funkcji jako wsparcie przeciw przed naciskiem nadkładu powierzchni drążonej i uaktywnić redukcję parcia, należy jak najszybciej opracować wyższej jakości smar, który poradzi sobie z wyżej wymienionymi problemami. W celu sprawdzenia charakterystyki i zachowania się materiału stanowiącego smar oraz wypełnienie dla systemu wykopu głębszych warstw jak w przypadku mikrotunelingu, przeprowadzono badania, których wyniki i omówienie znajdują się w poniższym referacie.
Źródło:
Inżynieria Mineralna; 2013, R. 14, nr 2, 2; 37-42
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Behavior of damaged TBM tunnel under MJS and Micro-disturbance grouting treatment: a case study
Autorzy:
Feng, Shi
Yang, Yijun
Jiang, Yexiang
Li, Yongdi
Yao, Lianghao
Chen, Xiaolong
Powiązania:
https://bibliotekanauki.pl/articles/27312101.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
system strumieniowy metra
tunel
uszkodzenie
TBM
technologia
iniekcja mikrozakłóceniowa
naprawa
metro jet system
damage
tunnel boring machine
tunnel
micro-disturbance grouting
technology
treatment
Opis:
The operating subway tunnel is often damaged due to excessive deformation in China. In order to ensure the safe for operation, remediation and protection measures must be taken, especially in soft soil areas. This paper presents a case study on remedial scheme of damaged TBM (Tunnel Boring Machine) tunnel adjacent to excavation combining with MJS (Metro Jet System) and micro-disturbance grouting technology in Hangzhou, China. The track bed settlement, horizontal displacement and convergence of the TBM tunnel caused by MJS and micro-disturbance grouting construction were analyzed and discussed. The results showed the characteristics of soil layer under the tunnel have significant influence on the treatment effect. Even if multiple grouting was adopted, the treatment failure may occur under the combination action of external loads such as traffic load or surcharge load, which should be considered when civil engineers design remediation scheme. The results can provide practical experience and guidance for similar treatment scheme of damaged TBM tunnel.
Źródło:
Archives of Civil Engineering; 2023, 69, 2; 339--352
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rhomboid major muscle ultrasound-guided trigger point injection: a case report and technique description
Iniekcja punktu spustowego mięśnia równoległobocznego większego wykonywana pod kontrolą ultrasonografii: opis przypadku oraz opis techniki
Autorzy:
Leiva Pemberthy, Luz Miriam
Gallego, Daniel F
Zuluaga Ruiz, Maria Eugenia
Powiązania:
https://bibliotekanauki.pl/articles/1790773.pdf
Data publikacji:
2020-11-10
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
myofascial pain syndrome
ultrasound guidance
myofascial trigger point
trigger point injection
mięśniowo-powięziow y zespół bólowy
kontrola USG
mięśniowo-powięziowe punkty spustowe
iniekcja punktu spustowego
Opis:
Introduction: Myofascial pain syndrome is an acute and chronic painful musculoskeletal condition that involves muscle and surrounding connective tissue. Trigger point injection is a common treatment for this condition providing long-term relief. The procedure is generally safe; however some side effects have been reported including pain, nerve injury, bleeding, infection, and pneumothorax. Objective: To report a case of a patient with myofascial pain syndrome successfully treated by Ultra Sound-guided infiltration of a myofascial trigger point in the rhomboid major muscle. Case description: A 39-year-old presented with cervical and dorsal pain of 4 months of evolution. She had physical and occupational therapy, with partial improvement of cervical pain but persistence of dorsal pain. No abnormal finding was noted on the neurological examination. On palpation, the patient had a myofascial trigger point in the left rhomboid major muscle. Given the persistence of the myofascial trigger point after physical therapy, it was considered the patient might benefit from Ultra Sound-guided infiltration. No adverse events were reported. At the end of the procedure, the patient reported a 70% reduction in pain. The patient returned for a follow-up visit one month after the procedure, reporting pain relief of 80%. Conclusions: The use of an Ultra Sound-guided technique for trigger point injection decreases the risk of iatrogenic complications. The blind method may result in poor localization of the point. Further studies are required to develop Ultra Sound based criteria to determine its clinical use.
Wstęp: Mięśniowo-powięziowy zespół bólowy jest ostrym, przewlekłym i bolesnym stanem układu mięśniowo-szkieletowego, który obejmuje mięśnie oraz otacząjącą je tkankę łączną. Zastrzyk do punktu spustowego jest powszechnym sposobem leczenia tego schorzenia, dającym długotrwałą ulgę. Procedura jest generalnie bezpieczna; jednakże zgłaszano pewne objawy niepożądane takie jak ból, uszkodzenie nerwu, krwawienie, infekcję, oraz odmę opłucnową. Cel: Opis przypadku pacjentki z mięśniowo-powięziowym zespołem bólowym leczonej skutecznie za pomocą infiltracji pod kontrolą USG mięśniowo-powięziowego punktu spustowego w mięśniu równoległobocznym większym. Opis przypadku: 39-letnia pacjentka, z występującym od 4 miesięcy bólem szyjnym i grzbietowym. Po fizjoterapii oraz terapii zajęciowej, ból szyi częściowo złagodniał ale ból grzbietu utrzymywał się. W badaniu neurologicznym nie stwierdzono żadnych nieprawidłowości. Podczas badania palpacyjnego, w lewym mięśniu równoległobocznym większym pacjentki wykryto mięśniowo-powięziowy punkt spustowy . Biorąc pod uwagę utrzymywanie się mięśniowo-powięziowego punktu spustowego po fizjoterapii, uznano, że pacjentce mogłaby pomóc infiltracja po kontrolą ultrasonografii. Nie zgłoszono żadnych niepożą danych reakcji. Pod koniec zabiegu, pacjentka stwierdziła zmniejszenie nasilenia bólu o 70%. Miesiąc po zabiegu, pacjentka przyszła na wizytę kontrolną zgłaszając złagodzenie bólu o 80%. Wnioski: Zastosowanie techniki z użyciem ultrasonografii do iniekcji punktu spustowego zmniejsza ryzyko wystąpienia powikłań jatrogennych. Metoda “ślepa”, tj. bez zastosowania USG, może skutkować nieodpowiednią lokalizacją punktu. Potrzebne są dalsze badania w celu opracowania kryteriów opartych na ultrasonografii aby móc określić jej kliniczne zastosowanie.
Źródło:
Medical Rehabilitation; 2020, 24(3); 25-28
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies