Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "hip endoprosthesis" wg kryterium: Temat


Wyświetlanie 1-12 z 12
Tytuł:
Study of Contact Pressures in Total Hip Replacement
Autorzy:
Czerniec, Myron
Zubrzycki, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/2024022.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hip endoprosthesis
calculation method
contact mechanics
contact pressure
diameter of the endoprosthesis head
radial clearance
Opis:
Total hip arthroplasty is a complex procedure. The achievements of implantology enabled the development of a faithful representation of hip joint physiology as well as the production of materials that can successfully replace damaged natural tissues. The challenge is to correctly select the geometry of the endoprosthesis adequate to the load of the joint. Materials used for endoprosthesis are a metal head and a polymer cup (e.g. PE-UHMW). The main interactions in the endoprosthesis are friction and contact pressure, which must not exceed their limit. Exceeding them causes the destruction of the biomechanical system - plastic deformation of the polymer that is too large and the formation of unacceptable radial clearances. The paper presents the author's empirical method of determining the contact pressures in the tribological pair of the acetabulum - the head of the hip joint endoprosthesis. Based on the obtained research results, it was shown that the developed method gives correct solutions to the contact problem and gives reliable results. The assumption for the work was to prove that empirical methods give correct solutions to contact problems on a par with simulation methods such as FEM. The aim of the work was to demonstrate the correctness of the author's empirical method for determining the maximum contact pressures. Based on the author's developed calculation method of hip joint endoprosthesis contact parameters, the impact on maximum contact pressure and the angle of contact of the joint load was estimated depending on the diameter of the endoprosthesis and radial clearance. The correctness of changing the values of maximum contact pressure from the mentioned parameters was determined. Correspondingly: an increase in joint load causes a linear increase in the maximum contact pressure; increasing the diameter of the endoprosthesis head - their non-linear decrease, and increasing radial clearance - their increase.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 2; 176-183
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Stresses and Strains Distribution of Polyethylene Cups in Hip Joint Endoprosthesis at Various Articular Joints and Friction Conditions
Autorzy:
Mordal, Katarzyna
Szarek, Arkadiusz
Powiązania:
https://bibliotekanauki.pl/articles/2049722.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
polyethylene
UHMWPE
hip joint endoprosthesis
friction conditions
computer modelling
Opis:
The article has been devoted to issues connected with the alloplasty and hip joint endoprostheses, that elements are being developed, which is supported by strength, tribological tests on used biomaterials, incl. polyethylene or computer modelling based on e.g. finite element method (FEM). In this paper, the results of research on the impact of the material articulations of the system head – acetabular and friction conditions on strength parameters of polyethylene components in the hip joint endoprosthesis. Numerical analysis of this friction node was carried out, using the ADINA System computer program and the simulations were performed at various friction conditions for metal/ polyethylene and ceramic/ polyethylene articulations with various UHMWPE modifications. The simulations results have shown the influence of tested material associations and friction conditions on parameters related to the strength of polyethylene cups, i.e. their displacements, stresses and deformations.
Źródło:
Archives of Metallurgy and Materials; 2021, 66, 2; 523-530
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of wear of polyethylene hip joint cup related to its positioning in patient’s body
Autorzy:
Rońda, J.
Wojnarowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/307555.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
hip joint endoprosthesis
wear
coefficient of wear
finite element method
proteza stawu biodrowego
metoda elementów skończonych
zużycie
Opis:
Polyethylene parts of endoprosthesis are the weakest parts of each medical implant. They can be worn out within several years. During this period, a patient can enjoy good physical efficiency until the wear of polyethylene part limits his/her mobility. Then the reoperation is necessary and positioning of all parts of endoprosthesis has an effect on future patient’s mobility and durability of implant. Elements of endoprosthesis during exploitation are heavily loaded both by normal and tangential forces and moments. In this paper, the dependence of wear of polyethylene cup on its positioning in pelvis is the major problem. Wear of the cup is determined by two measures: the depth and volume of a material rubbed off from the contact surface. The sensitivity of the depth of rubbing off is evaluated relative to two angles of anteversion and abduction, and radii of the cup. Numerical results are obtained by using Abaqus FE system with data related to patient’s activity identified on the basis of medical reports.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 1; 77-86
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hip joint and hip endoprosthesis biomechanics
Biomechanika stawu biodrowego i jego endoprotezy
Autorzy:
Gryka, J.
Powiązania:
https://bibliotekanauki.pl/articles/101786.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Polskie Towarzystwo Promocji Wiedzy
Tematy:
hip joint
hip joint endoprosthesis
biomechanics of lower limb
total hip replacement
staw biodrowy
endoproteza stawu biodrowego
biomechanika kończyny dolnej
całkowita wymiana stawu biodrowego
Opis:
This article contains a description of the basic issues related to anatomy, loading of hip joint and its endoprosthesis research methods. The methods of testing and simulating hip joint loads, factors that influence the selection of parameters during the design of prostheses, typical solutions to engineering problems related to this topic are presented. The article concludes with short summary of the finite element method for the design of hip replacements.
Artykuł zawiera opis podstawowych zagadnień związanych z anatomią, obciążeniami i metodami badawczymi dotyczących stawu biodrowego oraz jego endoprotezy. Przedstawione są sposoby badania i symulowania obciążeń w stawie biodrowym, czynniki wpływające na dobieranie parametrów podczas projektowania endoprotezy oraz typowe rozwiązania problemów inżynierskich związanych z tym tematem. Artykuł zakończony jest krótkim streszczeniem zastosowań metody elementów skończonych podczas projektowania endoprotezy stawu biodrowego.
Źródło:
Journal of Technology and Exploitation in Mechanical Engineering; 2017, 3, 1; 21-27
2451-148X
Pojawia się w:
Journal of Technology and Exploitation in Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Design and Structural Analysis of the Endoprosthesis of the Hip Joint
Autorzy:
Karpiński, R.
Jaworski, Ł.
Szabelski, J.
Powiązania:
https://bibliotekanauki.pl/articles/117650.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Promocji Wiedzy
Tematy:
hip
endoprosthesis
FEA
Opis:
The paper presents results of the preliminary structural analysis of model of the endoprosthesis of the hip joint. Basics of anatomy and biomechanical analysis of the hip joint were introduced. Based on data from atlas of human anatomy and medical imaging, the prototype of endoprosthesis was modelled using Solid Edge ST8 software. After determining physical properties of structural materials, the Finite Elements Analysis of the model was conducted using in SolidWorks software under various load conditions. Finally the results of analysis are presented.
Źródło:
Applied Computer Science; 2016, 12, 1; 87-95
1895-3735
Pojawia się w:
Applied Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of stress and strain occuring in the contact area of ceramic head - ceramic cup in the hip endoprostheses
Autorzy:
Sobociński, M.
Powiązania:
https://bibliotekanauki.pl/articles/122522.pdf
Data publikacji:
2013
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
endoprosthesis of hip joint
numerical modeling stress
strain Weibull’s model
model naprężenia Weibulla
modelowanie numeryczne odkształceń
Opis:
The paper presents the results of numerical analysis of the system “ceramic head - ceramic cup” in the hip joint endoprosthesis. Applying the Al2O3 ceramics in this kind of solutions, apart from all values of this material, can lead to grinding, if a high load is used. The analysis was run on the ADINA system. The geometrical model was elaborated on real measurements of the elements of endoprosthesis and also on the results provided by the producer.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2013, 12, 2; 89-96
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the effects of Proprioceptive Neuromuscular Facilitation therapy on the improvement of motor function in a patient after total hip replacement – a case study
Autorzy:
Guzik, Agnieszka
(, Anna Szpitman
Drużbicki, Mariusz
Wyszyńska, Justyna
Wolan-Nieroda, Andżelina
Powiązania:
https://bibliotekanauki.pl/articles/454875.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Rzeszowski. Wydawnictwo Uniwersytetu Rzeszowskiego
Tematy:
hip joint
osteoarthritis
endoprosthesis plasty
PNF method
total hip arthroplasty
Opis:
Hip osteoarthritis is a serious clinical and social problem. The number of patients who suffer from degenerative changes in the hip joints and require endoprosthesis-plasty is constantly increasing. This paper presents physiotherapeutic activities based on Proprioceptive Neuromuscular Facilitation (PNF) which optimize a patient’s mobilization using the reserves in their body fully to make improvements in movement and to regain lost functions for achieving beneficial therapeutic effects. The aim of the study was to evaluate the influence of PNF therapy on changes in muscle strength, mobility, and gait pattern in patients after Total Hip Arthroplasty. The case described here regards a 63-year-old woman diagnosed with left hip osteoarthritis who had Total Hip Arthroplasty. The patient was examined twice before and after PNF therapy. The range of mobility of hip joints, level of pain, muscular strength and gait were assessed. Applied PNF therapy, including dynamic (eccentric, concentric) and static muscle training, post-isometric relaxation, stabilization and control in the stance phase, resulted in improved hip joint mobility, muscle strength, gait pattern and pain reduction in the patient. The case study demonstrates that a short (two-week) but intensive (over two hours per day) PNF therapy positively influenced selected motor functions after Total Hip Arthroplasty.
Źródło:
European Journal of Clinical and Experimental Medicine; 2017, 3; 287-294
2544-2406
2544-1361
Pojawia się w:
European Journal of Clinical and Experimental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An assessment of the return to professional activity of patients aged ≤30 years after hip replacement surgery
Autorzy:
Drobniewski, Marek
Synder, Marek
Krasińska, Magdalena
Sibiński, Marcin
Borowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2093867.pdf
Data publikacji:
2021-12-13
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
return to work
arthroplasty
total hip replacement
hip arthritis
clinical and radiological outcome
endoprosthesis
Opis:
ObjectivesThe study evaluated the professional activity of patients after a total cementless hip replacement surgery performed at the age of ≤30 years.Material and MethodsThe study group comprised 87 patients, with 95 total cementless hip replacements. The mean age was 25.7 years. The youngest patient was 17 years old, and the oldest 30 years old. The mean length of observation was 20.1 years, ranging 5–33 years. All patients underwent clinical and radiological evaluations before the surgery, and again in the third, sixth and twelfth months after the surgery. Further follow-up visits were performed every year. The tests were scored according to the Merle d’Aubigné and Postel (MAP) classification, as recommended by the Polish Society of Orthopaedics and Traumatology. Postoperative radiographs were used to assess the position of the endoprosthesis, and the degree of implant healing in the bone tissue. The data was subjected to statistical analysis.ResultsOf the surveyed group, 67 patients were professionally active before the surgery: 34 were white-collar workers, 29 manual workers, and 4 students or school pupils. The remaining 20 had not worked for many years, and were receiving sickness or disability benefits. An excellent result, according to the Kellgren-Lawrence classification, was noted in 22 cases, a good result in 42 cases, and a satisfactory result in 6 cases. In 25 cases, a poor result was observed. All of the patients professionally active before the surgery returned to work following the procedure. A further analysis found that 15 previously-unemployed patients commenced employment following the procedure. The mean length of the sick leave was 196.2 days, and rehabilitation payments were granted in 5 cases.ConclusionsTotal cementless hip replacement is a valuable method of treating osteoarthritis in young patients. All of the patients who worked before the surgery returned to work in the same position and on the same employment conditions. Most of the previously-unemployed patients commenced employment following the procedure.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2021, 34, 6; 747-754
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Failure analysis of a femoral hip stem made of stainless steel after short time of exposure
Autorzy:
Mierzejewska, Ż. A.
Oksiuta, Z.
Powiązania:
https://bibliotekanauki.pl/articles/386661.pdf
Data publikacji:
2014
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
hip replacement
endoprosthesis stem fracture
isolated fracture
total hip arthroplasty complications
fatigue fracture
proteza stawu biodrowego
endoproteza
pękanie zmęczeniowe
Opis:
This paper describes a case study summarising the failure analysis of a stainless steel femoral stem, which failed prematurely within 36 months of exploitation in human body. In order to determine the mechanism of failure, a broken stem component were analyzed by means of macroscopic and microscopic obserwations and hardness measurements. Metallurgical obserwations revealed that the tested material does fulfill ASTM requirements. Scanning electron microscopy images revealed the presence of stress-induced cracking. The results of the hardness revealed significant nonuniformity from the surface towards the inner part of the stem. It is assumed that any discontinuity or defect on the fracture surface of the stem acted as preferential site for a crack nucleation and propagation by fatigue until the cross section of stem was not able to sustain a load generated by a patient.
Źródło:
Acta Mechanica et Automatica; 2014, 8, 3; 146-150
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The structural analysis of socket inlays of the hip endoprosthesis
Analiza strukturalna wkładki endoprotezy stawu biodrowego
Autorzy:
Karpiński, R.
Jaworski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/101806.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Polskie Towarzystwo Promocji Wiedzy
Tematy:
endoprosthesis
finite element method
hip joint
socket inlay
endoproteza
wkładka endoprotezy
metoda elementów skończonych
staw biodrowy
Opis:
The paper presents results of the preliminary structural analysis of socket inlays model of the endoprosthesis of the hip joint. Basics of anatomy and biomechanical analysis of the hip joint were introduced. The prototype of socket inlay of the hip endoprosthesis was modeled using Solid Edge ST8 software. After determining physical properties of structural materials for socket inlays, the Finite Elements Analysis of the model was conducted using SolidWorks software under various load conditions. Finally the results of analysis were presented.
W pracy przedstawiono wyniki wstępnej analizy strukturalnej wkładki endoprotezy stawu biodrowego. Zaprezentowano podstawowe informacje z anatomii oraz biomechaniki stawu biodrowego. Model wkładki endoprotezy wykonano z wykorzystaniem oprogramowania Solid Edge ST8. Po określeniu właściwości fizycznych materiałów stosowanych na wkładki endoprotezy przeprowadzono analizę Metodą Elementów Skończonych w programie SolidWorks dla różnych warunków obciążenia. Zaprezentowano uzyskane wyniki.
Źródło:
Journal of Technology and Exploitation in Mechanical Engineering; 2016, 2, 1; 36-39
2451-148X
Pojawia się w:
Journal of Technology and Exploitation in Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stand for Tribological Studies of Hip Joint Endoprosthesis with the Possibility of Changing Acetabulum Anteversion Angle and Head Anti Torsion Angle
Stanowisko do badań tribologicznych endoprotez stawu biodrowego z możliwością zmiany kąta antewersji panewki i kąta antetorsji głowy
Autorzy:
Wiśniewski, Tomasz
Libera, Michał
Łapaj, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/2200627.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hip joint movement simulator
endoprosthesis
wear
metal-metal contact
symulator ruchu stawu biodrowego
endoproteza
zużycie
skojarzenie materiałowe metal–metal
Opis:
The article presents the construction of a hip joint movement simulator intended for friction and wear studies of hip joint endoprostheses. The endoprosthesis head is mounted on a special base in the lower position with a neck-shaft angle of 135°, while the acetabular cup of the endoprosthesis is mounted in the upper part in the mounting head with an inclination angle of 45°. The production of three heads (responsible for the anteversion angle of the acetabulum) and three special bases (responsible for the antitorsion angle of the head) with different fixing angles of the components of the hip joint endoprosthesis, made it possible to carry out tribological tests with nine variants of alignment settings. The hip joint endoprosthesis tester is designed to simulate the following movements: flexion and extension as well as loads occurring in the human hip joint while walking. The subject of friction and wear studies were hip joint endoprostheses with a head diameter of 44 mm, made of high-carbon Co28Cr6Mo alloy. For each of the nine variants of endoprosthesis component alignment settings, average values of the coefficient of friction were calculated based on the recorded values of the friction. torque.
W artykule przedstawiono konstrukcję symulatora ruchu stawu biodrowego, przeznaczonego do badań tarciowo-zużyciowych endoprotez stawu biodrowego. Głowa endoprotezy mocowana jest na cokole w dolnym położeniu z kątem szyjkowo-trzonowym 135°, natomiast panewka endoprotezy zamontowana jest w górnej części w głowicy mocującej z zachowaniem kąta inklinacji 45°. Wykonanie trzech głowic (odpowiedzialnych za kąt antywersji panewki) oraz trzech cokołów (odpowiedzialnych za kąt antetorsji głowy) różniących się kątami osadzenia komponentów endoprotezy stawu biodrowego umożliwiło przeprowadzenie testów tribologicznych z dziewięcioma wariantami ustawień. Tester endoprotezy stawu biodrowego przeznaczony jest do symulacji ruchów: zgięcia i wyprostu oraz obciążeń występujących w stawie biodrowym człowieka podczas chodu. Przedmiotem badań tarciowo-zużyciowych były endoprotezy stawu biodrowego o średnicy głowy 44 mm, wykonane z wysokowęglowego stopu Co28Cr6Mo. Dla każdego z dziewięciu wariantów ustawień komponentów endoprotezy obliczone zostały średnie wartości współczynnika tarcia w oparciu o rejestrowane wartości momentu tarcia.
Źródło:
Tribologia; 2022, 4; 103--112
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stand for tribological testing of hip endoprostheses
Stanowisko do badań tribologicznych endoprotez stawu biodrowego
Autorzy:
Wiśniewski, T.
Mróz, A.
Magda, J.
Wielowiejska-Giertuga, A.
Powiązania:
https://bibliotekanauki.pl/articles/189054.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
hip joint simulator
endoprosthesis
friction torque
wear
metal-on-polyethylene articulation
symulator ruchu stawu biodrowego
endoproteza
moment sił tarcia
zużycie
skojarzenie materiałowe metal-polietylen
Opis:
The paper presents a new construction of hip-joint simulator. The SBT-01.2 simulator is designed for conducting tribological testing of hip endoprostheses based on ISO 14242-1, which specifies the requirements for the range of motion and load characteristics of the friction pair (femoral head vs. acetabular cup) during one test cycle. The construction of the simulator is based on the anatomical structure of the human hip joint. The prosthesis acetabulum is mounted in the upper part of the mounting head while maintaining the inclination angle relative to the axis of the socket to the direction of the loading force. The head of the prosthesis is mounted on a pin embedded in the bottom, movable base. After placing a special sleeve on the lower base, liquid lubricant is applied on the head-cup tribological system. The employed software enables continuous control, online visualization, and data recording. During testing, parameters such as lubricant temperature, instantaneous loading force, friction torque, and the number of cycles are recorded.
W artykule przedstawiono nową konstrukcję symulatora ruchu stawu biodrowego. Symulator SBT-01.2 przeznaczony jest do realizacji badań tribologicznych endoprotez stawu biodrowego w oparciu o normę ISO 14242-1, która określa wymogi dotyczące zakresu ruchów i charakterystyki obciążenia pary trącej (głowa-panewka) w czasie jednego cyklu badawczego. Konstrukcja symulatora oparta została na anatomicznej budowie stawu biodrowego człowieka. Panewka endoprotezy zamontowana jest w górnej części w głowicy mocującej z zachowaniem kąta inklinacji osi panewki względem kierunku przyłożenia siły obciążającej. Głowa endoprotezy mocowana jest na trzpieniu osadzonym w dolnej, ruchomej podstawie. Po założeniu specjalnego rękawa na dolnej podstawie układ tribologiczny głowa-panewka zalewany jest cieczą smarującą. Zastosowane oprogramowanie umożliwia stałą kontrolę, wizualizację online i zapis danych. Podczas testu rejestrowane są takie parametry jak: temperatura cieczy smarującej, chwilowa wartość siły obciążającej, moment siły tarcia i aktualna liczba cykli.
Źródło:
Tribologia; 2016, 270, 6; 167-177
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies