Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "air volume" wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
Impact of Clothing Size on Thermal Insulation – A Pilot Study
Autorzy:
Młynarczyk, Magdalena
Orysiak, Joanna
Jankowski, Jarosław
Prus, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/24200936.pdf
Data publikacji:
2023
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
thermal insulation
air gap
air volume
3D scanning
Opis:
Thermal insulation may be influenced by the size of clothing and thus the volume of air gaps. The aim of this study was to determine the relationship between the size of outer wear clothing, and thus the indirect fit (the volume and size of air gaps), and thermal insulation in static and dynamic conditions. A set of underwear and two types of outerwear for workers of the energy sector and the chemical industry were selected for the study. Results showed that the value of thermal insulation (regardless of the type of outerwear) first increased with increasing clothing size.
Źródło:
Fibres & Textiles in Eastern Europe; 2023, 31, 1; 1--8
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of air springs volume using indirect method in the design of selected pneumatic devices
Autorzy:
Urbansky, M.
Homišin, J.
Kaššay, P.
Krajňák, J.
Powiązania:
https://bibliotekanauki.pl/articles/386269.pdf
Data publikacji:
2018
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
air tank volume determination
indirect method
air pressure measurement
Opis:
At our department, we deal with continuous tuning of torsional oscillating mechanical systems (TOMS) during their operation in terms of torsional oscillation size. Therefore, a new mobile mechanical system was built for purposes of research and presentation of the TOMS continuous tuning using extremal control method, which main advantage is that we do not need to know a mathematical model of the mechanical system. The new mobile device is equipped with a special compressed air distribution system, which important components are air springs. The air springs are modified and used as air pressure tanks with various functions in the mobile device. Therefore, it is important to know the magnitude of the air springs inner volume. This paper deals with determination of air springs volume using indirect method, which is based on the air pressure measurement and also the comparison of obtained results with the results computed from air springs manufacturer data.
Źródło:
Acta Mechanica et Automatica; 2018, 12, 1; 19-22
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the continuous traverse trajectory and dynamic error of the vane anemometer on the accuracy of average velocity measurements at the cross-section of the mine heading – model-based testing
Wpływ trajektorii trawersu ciągłego oraz błędu dynamicznego anemometru skrzydełkowego na dokładność pomiaru prędkości średniej w przekroju wyrobiska kopalnianego – badania modelowe
Autorzy:
Jamróz, P.
Powiązania:
https://bibliotekanauki.pl/articles/219564.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
strumień objętości powietrza
trawers ciągły
profil prędkości
anemometr skrzydełkowy
błąd dynamiczny
air volume flow
continuous traverse
velocity profile
vane anemometer
dynamic error
Opis:
This paper discusses the problem of measuring the average velocity at the cross-section of mine heading with the use of the continuous traverse method. Based on model testing, it has been shown that measurement signals, obtained along the traversing trajectory, belong to the group of non-stationary signals. The methodology of the traversing method measurements, with the aspect of capabilities of measuring instruments used for that purpose, has been analysed. Results of simulation tests concerning the dynamic response of a vane anemometer to the measurement signal for selected trajectories of the continuous traverse have been presented. For this purpose, a velocity profile presenting an expanded stream of undisturbed air flow in the excavation has been used. Attention has been paid to the problem of selecting an adequate trajectory of anemometer movement, as the value of the velocity measured at the cross-section depends on the trajectory.
W artykule poruszono problem pomiarów prędkości średniej w przekroju wyrobiska kopalnianego z wykorzystaniem metody trawersu ciągłego. Na podstawie badań modelowych wykazano, że sygnały pomiarowe, które uzyskuje się wzdłuż trajektorii trawersowania należą do grupy sygnałów niestacjonarnych. Przeanalizowano metodologię przeprowadzania pomiarów metodą trawersowania w aspekcie możliwości pomiarowych wykorzystywanych w tym celu urządzeń pomiarowych. Przedstawiono wyniki badań symulacyjnych dynamicznej odpowiedzi anemometru skrzydełkowego na sygnał pomiarowy dla wybranych trajektorii trawersu ciągłego. W tym celu wykorzystano profil prędkości przedstawiający rozwiniętą strugę niezakłóconego przepływu powietrza w chodniku. Zwrócono uwagę na problem doboru odpowiedniej trajektorii przemieszczania anemometru, od której zależy wartość mierzonej prędkości średniej w przekroju.
Źródło:
Archives of Mining Sciences; 2014, 59, 4; 1051-1060
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radioactivity of ground-level air in Poland in 1998-1999. Results from ASS-500 stations network
Autorzy:
Bysiek, M.
Biernacka, M.
Lipiński, P.
Powiązania:
https://bibliotekanauki.pl/articles/148059.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
air
high-volume samplers
radionuclides
Opis:
The results of measurements of aerosol samples in the 1998-1999 period in the monitoring network of the ASS-500 stations in Poland are presented. The concentration of 137Cs remained at a rather low level during these two years. Higher levels resulting from the Algeciras release in southern Spain were identified in the first week of June 1998 at four stations situated in southern Poland. Higher concentrations of 137Cs were also observed during some other weeks of the presented period, but their origin has not been identified. The radionuclides of natural and antrophogenic origin were at their normal levels of activity. For comparison, the results from some other European stations are presented.
Źródło:
Nukleonika; 2001, 46, 4; 171-173
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of monovalent cations on soil structure. Part II. Results of two Swiss soils
Autorzy:
Farahani, Elham
Emami, Hojat
Keller, Thomas
Powiązania:
https://bibliotekanauki.pl/articles/972565.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
: air-permeability
sodium
potassium
soil shrinkage
specific volume
turbidity
Opis:
In this study, we investigated the impact of adding solutions with different potassium and sodium concentrations on dispersible clay, water retention characteristics, air permeability, and soil shrinkage behaviour using two agricultural soils from Switzerland with different clay content but similar organic carbon to clay ratio. Three different solutions (including only Na, only K, and the combination of both) were added to soil samples at three different cation ratio of soil structural stability levels, and the soil samples were incubated for one month. Our findings showed that the amount of readily dispersible clay increased with increasing Na concentrations and with increasing cation ratio of soil structural stability. The treatment with the maximum Na concentration resulted in the highest water retention and in the lowest shrinkage capacity. This was was associated with high amounts of readily dispersible clay. Air permeability generally increased during incubation due to moderate wetting and drying cycles, but the increase was negatively correlated with readily dispersible clay. Readily dispersible clay decreased with increasing K, while readily dispersible clay increased with increasing K in Iranian soil (Part I of our study). This can be attributed to the different clay mineralogy of the studied soils (muscovite in Part I and illite in Part II).
Źródło:
International Agrophysics; 2018, 32, 1
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A comparative study for double pass solar air collector utilizing medial glass panel
Autorzy:
Salih, Hussein M.
Powiązania:
https://bibliotekanauki.pl/articles/27309858.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
solar air collector
double-pass
CFD
finite volume
thermal performance
kolektor powietrza słonecznego
skończona objętość
wydajność cieplna
Opis:
A numerical investigation of thermal prediction of double-pass solar air heater of-counter flow is developed in the present study. The main idea of the current study is that the collector consists of two layers of glass so that the middle layer is glass instead of the usual metal plate. The performance of double-pass solar air heater is studied for a wide range of solar radiation intensities (600, 750 and 900 W/m 2). A FORTRAN-90 program is built to simulate the mathematical model of double-pass solar air heater based on solving steady state two-dimensional Navier-Stokes equations and energy equation based on finite volume method. Turbulence effect is simulated by two equations k-ε module. The results are compared with the results of a previous experimental study and a good agreement was found. From compression calculating efficiency of the present and traditional collector for each solar intensity, it was found that the efficiency of the current collector is higher than that of the traditional one, where the efficiency of the current collector at the solar intensity of (600, 750 and 900) W/m 2 are (0.529, 0.514 and 0.503), respectively, while those of the traditional collector (0.508, 0.492 and 0.481), respectively. In addition to this, the effect of the mass flow rate on the temperature difference of the current proposed collector was studied. Three values of the mass flow rate were studied (0.009,0.018, and 0.027) kg/s at solar intensity of 750 W/m 2. From this it was found that the temperature difference decreases with increasing mass flow rate. Accordingly, the efficiency decreases
Źródło:
Archive of Mechanical Engineering; 2022, LXIX, 4; 729--747
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of drying parameters and methods on the volume increase of dried apples during their rehydration
Wpływ parametrów i metody suszenia na wzrost objętości suszonych jabłek podczas ich rehydracji
Autorzy:
Winiczenko, R.
Kaleta, A.
Górnicki, K.
Choińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/93468.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
manner of grinding
temperature
velocity
drying air
drying
rehydration
volume
apple
rozdrobnienie
temperatura
prędkość
powietrze suszące
suszenie
rehydracja
objętość
jabłko
Opis:
The objective of this paper was to analyse the impact of parameters and drying method on the increase of the volume of dried apple slices and cubes during their rehydration. Ligol apples (cut into 3 and 10 mm slices and 10 mm cubes) were dried with the following methods: natural convection (temperature of drying 60ºC), forced convection (a tunnel drier, parameters of drying air: 50, 60, 70ºC and 0,5, 2 m·s-1), fluid drying (60ºC and 6 m·s-1). Dried fruit were rehydrated in the distilled water of 20ºC temperature. Determination of volume was carried out with an uplift pressure method in petroleum ether. Tests proved the impact of ground dried particles and the impact of drying method on the increase of the volume of dried apples during their rehydration. The final volume of the rehydrated dried fruit increased along with the reduction of drying temperature, these differences in numerical values were low, but statistically significant.
Celem pracy była analiza wpływu parametrów i metody suszenia na wzrost objętości suszonych plastrów i kostek jabłek podczas ich rehydracji. Jabłka odmiany Ligol (plastry o grubości 3 i 10 mm, kostki sześcienne o boku 10 mm) suszono następującymi metodami: konwekcja naturalna (temperatura suszenia 60ºC); konwekcja wymuszona (suszarka tunelowa, parametry powietrza suszącego: 50, 60, 70ºC oraz 0,5, 2 m·s-1); suszenie fluidalne (60ºC i 6 m·s-1). Susz rehydrowano w wodzie destylowanej o temperaturze 20ºC. Oznaczenie objętości wykonano metodą wyporu w eterze naftowym. Badania wykazały wpływ rozdrobnienia suszonych cząstek i wpływ metody suszenia na wzrost objętości suszonych jabłek podczas ich rehydracji. Końcowa objętość rehydrowanego suszu rosła z obniżeniem temperatury suszenia, różnice te w wartościach liczbowych były niewielkie, ale statystycznie istotne.
Źródło:
Agricultural Engineering; 2014, 18, 2; 219-228
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computational fluid dynamics modelling of short timebottle filling process
Autorzy:
Jałowiecka, Monika
Makowski, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/185137.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air entrainment
bottle filling
Computational Fluid Dynamics
multiphase flow
Volume of Fluid method
napowietrzenie
napełnianie butelek
Obliczeniowa dynamika płynów
przepływ wielofazowy
Metoda objętości płynu
Opis:
Every change in the bottle geometry as well as every change of physical and rheological properties posesa risk of excessive gas entrainment during a filling process. To maintain satisfactory filling efficiencythere is a need to optimise this process with respect to all adverse phenomena which affect the fluidflow, such as spluttering on the bottom, air caverns formation and air entrainment with incoming liquid.This paper comprises numerical simulations of two filling methods. The first method involves dosingwith a pipe placed over the free liquid surface of a fully filled bottle. The second method covers fillingwith a pipe located near the bottom. Moreover, the influence of rheological properties and surfacetension values is considered. The comprehensive analysis of amount of entrained air represented byair volume fraction in dispensed liquid let the authors define the influence of filling speed on themechanism and amount of entrapped air.
Źródło:
Chemical and Process Engineering; 2020, 41, 2; 143--163
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies