Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "TAP" wg kryterium: Temat


Tytuł:
Influence Of Transformer Tap Changer Operation On Voltage Stability
Autorzy:
Brusiłowicz, B.
Szafran, J.
Powiązania:
https://bibliotekanauki.pl/articles/410519.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
voltage stability
transformer tap changer
Opis:
The paper concerns influence of transformer tap changer regulation on secondary voltage level and voltage stability margin of receiving node. At the beginning there are presented general information about voltage stability and tap changer. Voltage value of secondary terminals of transformer can be regulated using tap changer. This regulation also affects the calculation of Thevenin equivalent parameters seen from the secondary terminals. Changes of equivalent parameters cause a change of voltage stability conditions. Simulation studies of this influence for various types of load have been done. Selected simulation results are presented in the paper. At the end there are placed conclusions from the performed studies.
Źródło:
Present Problems of Power System Control; 2013, 4; 25-36
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental factors affecting the survival of soil dwelling Legionella longbeachae in water
Autorzy:
Potočnjak, Mia
Magdalenić, Zlatko
Dijan, Marija
Rebić, Danica
Gobin, Ivana
Powiązania:
https://bibliotekanauki.pl/articles/990884.pdf
Data publikacji:
2016
Wydawca:
Instytut Medycyny Wsi
Tematy:
legionella
survival
stagnant tap water
temperature
Opis:
Introduction. Legionella longbeachae, a causative agent of Legionnaire’s disease, has often been associated with potting soil and gardening, a feature quite distinct from other Legionella species. The precise transmission mechanism is still unknown, although due to the ecological coherence of the soil and water there is a potential risk of infection by contaminated stagnant water in the garden. Objective. The aim of the study was to explore the ability of L. longbeachae to survive in stagnant tap water usually used for watering in gardens. The influence of different factors (temperature, pH and NaCl concentration) on L. longbeachae survival in stagnant tap water was also tested. Results. The result showed that L. longbeachae is viable in stagnant tap water over 100 days at 4 °C and 25 °C. The survival of L. longbeachae exposed to different pH and NaCl concentration suggests resistance to low pH values (pH2 and pH5) and all tested NaCl concentrations at temperatures lower than 25 °C. The ability of L. longbeachae to persist in stagnant tap water should be taken seriously in the risk assessments as a possible hidden reservoir of infection.
Źródło:
Annals of Agricultural and Environmental Medicine; 2016, 23, 3
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chemistry of tap water in selected localities on South Podlasie Lowland
Chemizm wody wodociągowej w wybranych miejscowościach niziny południowopodlaskiej
Autorzy:
Kalembasa, D.
Jaremko, D.
Becher, M.
Pakuła, K.
Stefański, K.
Powiązania:
https://bibliotekanauki.pl/articles/125944.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
tap water chemistry
ICP-AES
quality indicators of tap water
chemizm wody wodociągowej
wskaźniki jakości wody wodociągowej
Opis:
The aim of this paper is presentation of results of chemical composition of tap water in selected localities on South Podlasie Lowland. Samples of water were taken from water treatment station and taps situated in various parts of Lukow, Sokolow Podlaski and selected localities in Lochow, Wierzbno and Mokobody commune. Quarterly investigations covered analysis of water reaction (pH) by potentiometric method, electrical conductivity (EC) by electrochemical method and total concentration of 26 elements by inductively coupled plasma atomic emission spectrometry (ICP-AES). It was found that untreated waters being the source of tap water in selected localities on South Podlasie Lowland contained excessive iron and manganese amounts, that were efficiently removed during the treatment. Concentration of analyzed elements in treated water did not exceed the permissible limits and quality of analyzed tap water changed a little during its transport due to the secondary contamination.
Celem niniejszej pracy jest przedstawienie wyników analizy składu chemicznego wody wodociągowej dostarczanej mieszkańcom wybranych miejscowości Niziny Południowopodlaskiej. Punkty pobrania próbek do badań wyznaczono na wyjściu ze stacji uzdatniania oraz w kurkach czerpalnych, położonych w różnych dzielnicach Łukowa i Sokołowa Podlaskiego, a także w różnych miejscowościach gmin Łochów, Wierzbno i Mokobody. Próbki wody pobierano w odstępach kwartalnych. W pobranych próbkach oznaczono odczyn (pH) wody metodą potencjometryczną, przewodnictwo właściwe metodą elektrochemiczną oraz stężenie K, Ca, Mg, Na, S, Fe, Mn, B, Li, Ba, Sr, Cu, Zn, Ni metodą optycznej spektrometrii emisyjnej ze wzbudzeniem w plazmie sprzężonej indukcyjnie (ICP-AES). Stężenie pierwiastków objętych badaniami na ogół nie przekraczało obowiązujących wartości dopuszczalnych. Sporadycznie odnotowano podwyższone wartości analizowanych parametrów w próbkach wody pobieranych w kurkach czerpalnych, wskazujące na zanieczyszczenie wody w systemie dystrybucji. W wodzie surowej stwierdzono ponadnormatywne stężenia żelaza i manganu, ale pierwiastki te były skutecznie usuwane w procesie uzdatniania.
Źródło:
Proceedings of ECOpole; 2012, 6, 2; 523-528
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
More on the Rhotic Tap and the Implications of Its Structure
Autorzy:
Savu, Carmen Florina
Powiązania:
https://bibliotekanauki.pl/articles/504788.pdf
Data publikacji:
2014
Wydawca:
Komisja Nauk Filologicznych Polskiej Akademii Nauk, Oddział we Wrocławiu
Tematy:
rhotics
tap
vocalic elements
constriction
syllabic consonant
acoustic phonetics
Opis:
The topic of this paper is the rhotic segment with one constricted interval, the tap. This sound is typically considered to be, from the phonetic point of view, a simple small constricted interval because this is how it appears on a spectrogram when it is in intervocalic context. More recent studies (Stolarski 2011; Savu 2011, 2012) consider and argue that the tap is actually comprised of two vowel-like elements flanking this small constriction. After presenting the argument leading to this conclusion and briefly discussing the quality of the tap’s vocoids as shown by phonetic experiments, I approach the implications of this sound having the aforementioned structure. Specifically, I address the consequences for the status of syllabic /r/ in Macedonian and the different perception of /C(ɨ)rC/ sequences by speakers of Romanian and Slavic languages with syllabic /r/. In addition to this, I show how this structure of the tap suggests a possible phonetic account for vowel-rhotic metathesis between consonants as the migration of the constriction on a vocalic continuum provided by the tap and the full vowel.
Źródło:
Academic Journal of Modern Philology; 2014, 3; 75-87
2299-7164
2353-3218
Pojawia się w:
Academic Journal of Modern Philology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of the Non-Concurrent Operation of the On-Load Tap Changer Contacts by the Acoustic Emission Method
Autorzy:
Cichoń, A.
Borucki, S.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177044.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
on-load tap changers
acoustic emission method
Opis:
On-load tap changers (OLTC) are some of the main transformer elements that make voltage adjustment in a power network possible. Their failures often cause shutdowns of distribution transformers. The paper presents research work aimed at the assessment of the technical condition of OLTCs by the acoustic emission method (EA). This method makes the OLTC diagnosis possible without the need of disconnecting the transformer from the system. The measurements were taken in laboratory conditions. The influence on the operation non-concurrence of the power tap changer contacts on the AE registered signals has been investigated. The signals registered were subjected to analyses in the time and time-frequency domains. The result analysis in the time domain was carried out using the Hilbert transform and calculating characteristic times for the particular runs. A short-time Fourier transform was used for the assessment of results in the time-frequency do- main.
Źródło:
Archives of Acoustics; 2011, 36, 4; 823-830
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of Natural radioactivity in tap water samples for selected regions in Thi-Qar Governorate - Iraq
Autorzy:
Hadi, Hasan A.
Karim, Mahmood S.
Mahi, Ali T.
Abood, Tareq H.
Powiązania:
https://bibliotekanauki.pl/articles/1192660.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
(HPGe) detector
Thi-Qar governorate
tap water
specific activity
radionuclides
Opis:
In the present work, we have measured specific activity concentrations in ten tap water samples for selected regions in Thi-Qar governorate by using high purity germanium (HPGe) detector. The results have shown that, the specific activity, for 238U was ranged from (0.65±0.8 Bq/kg) in AL- Nasir region to (1.32±0.7.8 Bq/kg) in AL-Refai region, for 232Th the specific activity was ranged from (0.120±0.34 Bq/kg) in AL-Garraf region to (0.980±0.99 Bq/kg) in AL- Dwaya region, for 40K the specific activity was ranged from (13.33±3.6 Bq/kg) in AL-Nasir region to (38.54±6.2 Bq/kg) in (AL-Garraf) region, with an average values of (0.933±0.16 Bq/kg), (0.737±0.17 Bq/kg), (24.451±7.5Bq/kg), for 238U, 232Th and 40K, respectively. In order to asses the radiological hazards of the radioactivity in tap water, we have been calculated the parameters (Raeq , DƔ, AEDin , AEDout , EAD , Iɣ , Hin and Hex).
Źródło:
World Scientific News; 2016, 47, 2; 112-122
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of using borehole heat exchangers in Macedonia and in Poland
Autorzy:
Kowalski, T.
Ruvceska, A.
Śliwa, T.
Bieda, A.
Powiązania:
https://bibliotekanauki.pl/articles/298667.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
borehole heat exchangers
geothermal energy
heat pump
hot tap water
Opis:
Using borehole heat exchangers for heating and cooling in different climate conditions were analysed and compared in this paper, considering the heating and cooling modes of the heat pump. Economic analysis were made according to the energy demand for heating, cooling and hot tap water with borehole heat exchangers for a typical family house. The costs for running borehole heat exchangers in Macedonia and Poland were also based on the average monthly temperatures and geological profile of the location.
Źródło:
AGH Drilling, Oil, Gas; 2017, 34, 1; 141-156
2299-4157
2300-7052
Pojawia się w:
AGH Drilling, Oil, Gas
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simultaneous monitoring of chromatic dispersion and optical signal to noise ratio in optical links using convolutional neural network and asynchronous delay-tap sampling
Autorzy:
Mrozek, Tomasz
Perlicki, Krzysztof
Jakubiak, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1835803.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
deep learning
convolutional neural network
chromatic dispersion
OSNR
asynchronous delay-tap sampling
Opis:
The article presents a method for image analysis using asynchronous delay-tap sampling (ADTS) technique and convolutional neural networks (CNNs), allowing simultaneous monitoring of many phenomena occurring in the physical layer of the optical network. The ADTS method makes it possible to visualize the course of the optical signal in the form of characteristics (so-called phase portraits), which change their shape under the influence of phenomena (including chromatic dispersion, amplified spontaneous emission noise and other). Using the VPI photonics software,a simulation model of the ADTS technique was built. After the simulation tests, 10000 images were obtained, which after proper preparation were subjected to further analysis using CNN algorithms. The main goal of the study was to train a CNN to recognize the selected impairment (distortion); then to test its accuracy and estimate the impairment for the selected set of test images. The input data consisted of processed binary images in the form of two-dimensional matrices, with the position of the pixel. This article focuses on the analysis of images containing simultaneously the phenomena of chromatic dispersion and optical signal to noise ratio.
Źródło:
Optica Applicata; 2020, 50, 3; 331-341
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Real time voltage stabilization in microgrid
Autorzy:
Jangjoo, M. A.
Seifi, A. R.
Powiązania:
https://bibliotekanauki.pl/articles/141091.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
capacitor
distributed generation (DG)
on load tap changer (OLTC)
voltage stabilization
microgrid
Opis:
This study suggests a new algorithm based on a combination of fuzzy logic and genetic algorithm (GA) to improve voltage profile in a microgrid. The considered microgrid includes control variables such as onload tap changer (OLTC), active power output from distributed generators (DG) and reactive power output from feeder switched capacitors that are controlled in a microgrid controller (MGC) by communication links. The proposed method was used to obtain the optimum value of control variables to establish voltage stabilization in varying load condition as online. For establishing voltage stabilization at the microgrid, an objective function is defined and is tried to minimize it by control variables. The control variables were changed based on fuzzy logic and the GA was employed for finding the optimum shape of membership functions. In order to verify the proposed method, a 34 buses microgrid in varying load condition was analyzed and was compared with previous works.
Źródło:
Archives of Electrical Engineering; 2014, 63, 2; 273-293
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Features of magneto-abrasive machining of taps
Autorzy:
Maiboroda, Victor
Tarhan, Dmytro
Dzhulii, Dmytro
Slobodianiuk, Ivanna
Powiązania:
https://bibliotekanauki.pl/articles/387037.pdf
Data publikacji:
2020
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
tap
magneto-abrasive machining
cutting tools
machining intensity
polishing effect
strengthening effect
Opis:
The features of magneto-abrasive machining of taps for metric thread cutting were investigated. The calculation method of integral intensity of the magneto-abrasive machining of the working surfaces of the taps by the quantitative values of normal and tangential components of moving speed of the quasi-stable volumes of the magneto-abrasive tool was developed. Based on the results of calculations, it was possible to predict the probable influence of the taps’ location in the working zone on the quality and efficiency of machining their working surfaces. The calculation method is relevant for taps of all diameters with a profile angle of 60°. The working surfaces of the tool would not be effectively machined if the location angle of taps to the plane of the working zone of the machine equals 20–60°. Depending on the expected major polishing or strengthening effect of magneto-abrasive machining, the taps are required to be located at an angle of 60–90° to the plane of the working zone of the machine.
Źródło:
Acta Mechanica et Automatica; 2020, 14, 1; 1-7
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Changes in the properties of the surface layer of the internal thread made by cold forming
Zmiany właściwości warstwy wierzchniej gwintu wewnętrznego wykonywanego metodą wygniatania na zimno
Autorzy:
Czarnecki, H.
Michalczuk, H.
Tagowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/971351.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wygniatanie gwintów
mikrotwardość
własności warstwy wierzchniej
properties of surface layer
tap embossing
microhardness
Opis:
The study presents the influence of cold forming internal threads on the property changes of the surface layer of the obtained thread outline. As a result of material deformation, hardening increases, which increases the strength of the thread. In order to determine such changes, the distribution of microhardness was measured around the outline of the thread. The measurements and metallographic investigations permit the conclusion that such threading increases the microhardness of threads, especially on the sides of the outline, and its growth depends on the diameter of the initial hole. Microhardness testing helped to identify the changes in the area of unfilled apex of the thread. Metallographic images enable observation of the deformation zone and the fragmentation and orientation of the structure during the formation of the internal thread. The paper also presents the results of the fem simulation of thread cold forming process.
W opracowaniu przedstawiono wpływ wygniatania gwintów wewnętrznych na zimno na zmiany właściwości warstwy wierzchniej uzyskanego zarysu. Na skutek zgniotu następuje wzrost utwardzenia, a tym samym wzrost wytrzymałości wykonanego gwintu. W celu określenia tych zmian dokonano pomiaru rozkładu mikrotwardości na całym zarysie gwintu. Przeprowadzone pomiary oraz badania metalograficzne pozwalają stwierdzić, że wygniatanie gwintów powoduje wzrost mikrotwardości, szczególnie na bokach zarysu, a jego przyrost uzależniony jest od średnicy otworu wyjściowego. Badania mikrotwardości pozwoliły określić zmiany w obszarze niewypełnienia wierzchołka gwintu. Zdjęcia metalograficzne umożliwiły obserwację strefy odkształcenia oraz rozdrobnienia i ukierunkowania struktury podczas kształtowania gwintu wewnętrznego metodą wygniatania. Zaprezentowano również wyniki badań symulacyjnych procesu wygniatania z wykorzystaniem technik komputerowych.
Źródło:
Tribologia; 2016, 270, 6; 11-20
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamics of water consumption changes in a tourist resort
Autorzy:
Bartkowska, I.
Powiązania:
https://bibliotekanauki.pl/articles/125041.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
indicators
tap water
variation trends
water consumption
water requirement index
water supply system
Opis:
This work presents problems related to the water consumption in the city of Olecko situated in the north-east part of Poland in the Warmińsko-Mazurskie Province of the country, at the eastern border of the Mazurian Lake District along the trail connecting the land of the Large Mazurian Lakes with the Suwalsko-Augustowskie Lake District. Over 2011–2012 water extraction to the municipal water supply network was studied. The volume of water extracted every day was analyzed and the gathered volumes were analyzed statistically. The varying water extraction was also studied. The obtained results were presented in a graphic form. Basing on the descriptive stats and prepared diagrams certain general conclusions were drawn and the collected study figures and facts were summed up. This allowed to determine days of the highest and lowest water consumption. Also months of extreme water extraction and consumption were determined. The water extraction ranged from 1641 m3/24h to 2607 m3/24h, at an average value of 2077.4 m3/24h. Over the period under study the day of the largest water extraction and consumption was in July and the day of the lowest water extraction and consumption in December. During a week inhabitants used the highest water amount on Saturdays and the lowest on Sundays and other feast-days. Basing on the conducted measurements also the coefficient of water consumption per capita was determined. The fluctuation of this coefficient was identical as that for the water consumption. Within the period of study it ranged from 73.3 l/M 24h to 116.5 l/M 24h. The average value of the specific water consumption was 92.8 l/M 24h. For the sake of discussion the obtained results were compared with observations across the country.
Źródło:
Journal of Ecological Engineering; 2014, 15, 4; 46-54
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of the current situation of TSI TAP implementation in Poland
Autorzy:
Kruk, R.
Bartosik, B.
Powiązania:
https://bibliotekanauki.pl/articles/393946.pdf
Data publikacji:
2008
Wydawca:
Polskie Stowarzyszenie Telematyki Transportu
Tematy:
kolej
przepisy europejskie
interoperacyjność
European railway legislation
interoperability
TAP - Telematic Applications for Passenger Services
Opis:
This Technical Specification of Interoperability refers to the passenger carriage subsystem of the trans-European conventional railway system. This TSI relates to different aspects of passenger carriage, including providing passengers with information before and during their travel. This paper shows the proposed range of TSI TAP use, as well as the state of adaptation to the requirements of TSI TAP of the currently operating computer systems.
Źródło:
Archives of Transport System Telematics; 2008, 1, 1; 30-33
1899-8208
Pojawia się w:
Archives of Transport System Telematics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Health risk assessment resulting from the presence of Legionella bacteria in domestic hot water in public buildings – the results of a pilot study
Autorzy:
Kmiecik, Ewa
Wątor, Katarzyna
Chochorek, Aneta
Kołodziej, Mateusz
Mika, Anna
Krawiec, Arkadiusz
Herzig, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/1841764.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
Legionella pneumophila
tap water
public building
quantitative risk assessment
microbial risk assessment
risk matrix
Opis:
The aim of the study was to assess the risk posed by Legionella bacteria in a public building in Krakow. An old building with internal installation risers of different ages, as well as draw-off points of different types, was selected for testing. Samples were collected during two campaigns. In one sample of the first series of tests, no bacteria were found. During the second series of tests, no Legionella bacilli were found in just one sample and in one sample only 4 colony-forming units were detected. At the remaining draw-off points (water taps), the bacteria count detected were greater than the maximum threshold allowed by legal regulations (admissible threshold for public utility buildings – 100 cfu/100 mL). No morphological differences were observed with respect to the occurrence of specific serogroups. In 14 samples, Legionella pneumophila serogroups 2–14 were found, while the Legionella pneumophila serogroup 1 was only found in one sample. The risk assessment was also carried out based on a semi-quantitative risk matrix approach and as a quantitative microbial risk assessment. The risk matrix approach was successfully implemented for the recognition of the potential risk associated with the Legionella occurrence in a water system. The calculated annual cumulative risk is high. The research shows that even if the weekly inhalation exposure dose (and therefore the calculated risk) is high, the number of Legionella pneumophila illness cases found can be equal to zero. This is probably due to the large uncertainty associated with QMRA determination. The size of the room in which the contaminated water is used also affects the possibility of infection.
Źródło:
Geology, Geophysics and Environment; 2021, 47, 1; 41-52
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A simplified determination of the shape of a sugar beet tap-root
Uproszczone wyznaczanie kształtu korzenia palowego buraka cukrowego
Autorzy:
Błaszkiewicz, Z.
Sztukowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/956413.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
sugar beet
tap-root
shape
geometric model
burak cukrowy
korzeń palowy
kształt
model geometryczny
Opis:
This work presents theoretical and empirical analysis of the usefulness of the selected geometrical models, for the purpose of determination of the sugar beet root shape, based on the available root parameters: diameter, length and the bulb root height. Analysis covered four models in the form of: a spherical sector, composed of a conic and a half of a sphere, composed of a conic and a spherical cap, composed of a conic and a half of an ellipsoid. Within the scope of the assumption of this paper it was proved, that the shape of a tap-root can approximate the simplified model comprising a conic and a half of an ellipsoid.
W pracy przedstawiono rezultaty teoretyczno-empirycznej analizy przydatności wybranych modeli geometrycznych do opisu kształtu korzenia palowego buraka cukrowego, wyznaczanych w oparciu o dostępne wymiary korzenia: średnicę i jego długość oraz wysokość główki. Analizowano cztery modele w postaci: wycinka kuli, złożonego ze stożka i połowy kuli, stożka i czaszy kulistej oraz ze stożka i połowy elipsoidy. Wykazano, w zakresie założeń pracy, że stożkowy korzeń palowy może być opisany za pomocą uproszczonego modelu złożonego ze stożka i opartej na jego podstawie połowy elipsoidy.
Źródło:
Agricultural Engineering; 2015, 19, 1; 15-23
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies