Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Air power" wg kryterium: Temat


Tytuł:
Russia’s and NATO’s use of air power in comparison: what is to be expected?
Autorzy:
Grimshaw, Steven
Powiązania:
https://bibliotekanauki.pl/articles/534410.pdf
Data publikacji:
2017
Wydawca:
Wyższa Szkoła Biznesu w Dąbrowie Górniczej
Tematy:
Air power
Russian air force
NATO air power
Future warfare.
Opis:
This research analyses the Russian approach to the use of air power supporting direct subordination to ground forces in comparison with NATO’s approach of an independent component directly conducting the military objective through deep air operations. By drawing upon mostly open sources, this paper sheds light on possible advantages and limitations of both sides’ peculiar approaches in regards to possible future military encounters. Despite taking NATO’s evolution of air power into account, it becomes clear that the Russian military air forces cannot fully adapt in the near future due to mainly historical, economic, technological and geopolitical factors. Therefore, Russia’s air forces are rather unbalanced and incapable of applying the full potential of air power. Through analysing the origins and emphasising further implications as to future development, this research highlights the importance for NATO to focus more on achieving and maintaining air superiority including exploitation of its clear advantage in long-range aviation.
Źródło:
Security Forum; 2017, 1, Volume 1 No. 1/2017; 123-136
2544-1809
Pojawia się w:
Security Forum
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the Goliński-Jesionek multistage combined air/steam systems with external combustion
Autorzy:
Gnutek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/175431.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
binary cycles
combined cycles
external combustion
air/steam power plants
Opis:
In the paper a brief review of an air/steam set of thermodynamic cycles dedicated for energy production is presented. The main aim of this work is show to the Goliński-Jesionek multistage combined air/steam plants which improve efficiency. For this purpose, systems are first studied and secondly new concept is presented.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2014, 126; 33-54
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigating the Efficiency of Combined Cycle Power Plants with the Data Envelopment Analysis Process (with an Emphasis on Air Pollution)
Autorzy:
Sanjaranipour, Noushin
Atabi, Farideh
Momeni, Mansour
Ghodousi, Jamal
Lahijanian, Akramolmolok
Powiązania:
https://bibliotekanauki.pl/articles/2055783.pdf
Data publikacji:
2022
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
efficiency
Combined Cycle Power Plants
DEA
air pollution
Opis:
Performance management is one of the most significant strategies in promoting the efficiency of organizations and is highly sensitive. It is important to check the efficiency of combined cycle power plants because of their major contribution to power generation and air pollution. This study was conducted to evaluate the economic and environmental efficiency of Combined Cycle Power Plants (CCPPs). The inputs and outputs required to evaluate the performance of the power plants were determined according to expert opinions. Then, the 7-year statistics and information of the Qom, Neishabour, Shahid Rajaee, Yazd and Kerman power plants were collected as the desired CCPPs in Iran. The Window Data Envelopment Analysis (WDEA) method was used for evaluating the efficiency of the power plants. The 3-year window length showed that most of the power plants were efficient. Only the Rajaee, Neishabour and Yazd power plants were ineffective in some years. The mean efficiency of the power plants in the 4-year window length showed that the plants were efficient from 2008 to 2010.
Źródło:
Geomatics and Environmental Engineering; 2022, 16, 2; 111--125
1898-1135
Pojawia się w:
Geomatics and Environmental Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Controlling magnetic inductance by air-gap configuration in power electronics applications
Autorzy:
Kasikowski, Rafal
Powiązania:
https://bibliotekanauki.pl/articles/27309945.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
air gaps
electromagnetic modelling
magnetic cores
power electronics
Opis:
Gapped magnetic components are inherent to applications where conversion of power would force magnetic flux density beyond the saturation point of magnetic materials. A physical discontinuity in a magnetic path, which an air gap represents, signifies a drastic change in its reluctance to magnetic flux. This gives rise to a phenomenon referred to as the fringing effect, which impacts the performance of magnetic components. The fringing flux also affects the physical properties of magnetic components, such as magnetic reluctance and inductance. Since inductance of gapped magnetic components is a function of the size of the air gap, a relatively simple change to the configuration of the air gap or splitting a single gap into a plurality of gaps entails, frequently, a radical change to the magnetic circuit of the component. This paper examines the way the air-gap configuration affects the distribution of the fringing flux and, by extension, magnetic reluctance and inductance. A method to aid the design of multigap inductors is presented based on 3-D electromagnetic modelling as well as measurements. An analytic expression, which closely approximates the required length of quasi-distributed gaps substituting a single gap, is developed.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 677-695
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvement of the cargo fleet vessels power plants ecological indexes by development of the exhaust gas systems
Autorzy:
Kuznetsov, Valerii
Dymo, Boris
Kuznetsova, Svitlana
Bondarenko, Mykola
Voloshyn, Andrii
Powiązania:
https://bibliotekanauki.pl/articles/1573635.pdf
Data publikacji:
2021
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
marine power plant
emissions
gas-air cooler
nozzle
intensification
Opis:
Modernisation of the power plants of cargo fleet vessels to satisfy the requirements set out by the International Maritime Organisation is an urgent scientific and technical problem. The article presents the results of developing a solution to this problem that focuses on the exhaust gas system. We propose the use of ejection nozzles as part of this system. It was found that when the ejection coefficient in these nozzles is n = 3, it is possible to exclude the use of SCR reactors, thus reducing the operating costs of the marine power plant. Using a mathematical modelling method, the efficiency of operation of six types of nozzle as part of the exhaust gas system was investigated, and a constructive layout was proposed for the gas ducts and inlet louvres for supplying ambient air. To increase the efficiency of the proposed system, we consider several options for intensifying heat transfer processes through the use of dimple systems in the nozzles and nozzles with swirling flow. We found that these technical solutions would make it possible to further increase the efficiency of the systems by up to 19% abs.
Źródło:
Polish Maritime Research; 2021, 1; 97-104
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of regularities of ground-level air radionuclide contamination at the Russian coast of the Baltic Sea in the course of the long-term Leningrad Nuclear Power Plant (1983-1999) operation
Autorzy:
Blinova, L.
Goloubeva, L.
Dushin, V.
Michurina, T.
Powiązania:
https://bibliotekanauki.pl/articles/148106.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
air contamination
artificial radionuclides
7Be
nuclear power plant
Opis:
Long-term results of ground-level air radionuclide contamination at the Russian coast of the Baltic Sea (nuclear facilities in the vicinity of the town of Sosnovy Bor) are under consideration. As compared with 1992-1997 [1], the Leningrad Nuclear Power Plant (NPP) equipment hermetic sealing (in 1998-1999) caused both the reduction of detection frequency of 131I aerosol and the maximum concentrations of 137Cs in the ground-level air at the NPP site. Long-term weekly nuclides' concentration time series were examined by the correlation analysis. Results of the analysis are presented. The seasonal fluctuations of 7Be concentrations in the ground-level air were examined by the harmonic (Fourier) analysis. The seasonal fluctuations of its concentrations with the maximum in spring-summer period are shown.
Źródło:
Nukleonika; 2001, 46, 4; 179-182
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection and calculation of air cooling solutions in underground coal mines in Vietnam
Dobór i obliczenia rozwiązań chłodzenia powietrza w podziemnych kopalniach węgla w Wietnamie
Autorzy:
Borowski, Marek
Trung Tien, Quan
Łuczak, Rafał
Życzkowski, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1841452.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
air temperature
air humidity
air cooling
thermal power of cooler
temperatura powietrza
wilgotność powietrza
chłodzenie powietrza
moc cieplna chłodnicy
Opis:
Currently, Vietnamese underground mines have been exploited down to -500 m and, in the near future, they will be exploited deeper. The exploitation of coal of seams has an negative impact on a workers environment. The increase in the depth of coal seam exploitation causes is the increase of adverse microclimate factors such as temperature, moisture, heat radiation. According to the current Viet¬namese laws, coal deposits can be mined in a condition when air temperature does not exceed 30oC, although this rule is not always observed, especially during summer. The article show how reducing the adverse impact of climate factors in the mines and calculating the parameters which reduce the temperature on an example in one of underground coal mines in Vietnam.
Obecnie wietnamskie kopalnie podziemne zostały wyeksploatowane do -500 m, w najbliższej przyszłości będą eksploatowane głębiej. Eks¬ploatacja ma negatywny wpływ na środowisko. Działalność eksploatacji w wyrobiskach powoduje wzrost niekorzystnych czynników mi-kroklimatycznych, takich jak temperatura, wilgotność, promieniowanie cieplne. Zgodnie z obowiązującym wietnamskim prawem, złoża węgla mogą być eksploatowane w warunkach, gdy temperatura powietrza nie przekracza 30°C, chociaż nie zawsze jest to przestrzegane, zwłaszcza latem. W artykule przedstawiono rozwiązanie ograniczania niekorzystnego wpływu czynników klimatycznych w kopalniach oraz obliczenie parametrów obniżających temperaturę powietrza na przykładzie podziemnych kopalń węgla w Wietnamie.
Źródło:
Inżynieria Mineralna; 2020, 2, 2; 237-244
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaporation channel consumes hundred times more solar power than the winds over the globe
Autorzy:
Agrawal, Dulli C.
Powiązania:
https://bibliotekanauki.pl/articles/1119138.pdf
Data publikacji:
2017
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Free convection
air
earth
evaporation
rainfall
solar power
water
wind
Opis:
The free convection of the water and air over the globe induces evaporation of standing water and the generation of wind, respectively. The ratio of the corresponding heat transfer coefficients is shown to be equal to the ratio of solar power going into evaporation/precipitation and into wind generation. The present work provides a justification for the estimate on wind power reported by M. King Hubbert and also that wind generation on a global scale is about two-order magnitudes less than the solar power responsible for rainfall. This paper resolves the existing ambiguity in the estimates of wind power over the globe.
Źródło:
World News of Natural Sciences; 2017, 7; 42-48
2543-5426
Pojawia się w:
World News of Natural Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Correlation between air temperature and electricitydemand by linear regression and wavelet coherence approach: UK, Slovakia and Bosnia and Herzegovina case study
Autorzy:
Avdakovic, S
Ademovic, A.
Nuhanovic, A.
Powiązania:
https://bibliotekanauki.pl/articles/141710.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power system
electricity demand
air temperature
linear regression
wavelet coherence
Opis:
In this paper, the results of correlations between air temperature and electricity demand by linear regression and Wavelet Coherence (WTC) approach for three different European countries are presented. The results show a very close relationship between air temperature and electricity demand for the selected power systems, however, the WTC approach presents interesting dynamics of correlations between air temperature and electricity demand at different time-frequency space and provide useful information for a more complete understanding of the related consumption.
Źródło:
Archives of Electrical Engineering; 2013, 62, 4; 521-532
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Turbine stage expansion model including internal air film cooling and novel method of calculating theoretical power of a cooled stage
Autorzy:
Trawiński, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2134930.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas turbine
expansion line
air film cooling
theoretical stage power
Opis:
Systematic attempts to maximise the efficiency of gas turbine units are achieved, among other possibilities, by increasing the temperature at the inlet to the expansion section. This requires additional technological solutions in advanced systems for cooling the blade rows with air extracted from the compressor section. This paper introduces a new mathematical model describing the expansion process of the working medium in the turbine stage with air film cooling. The model includes temperature and pressure losses caused by the mixing of cooling air in the path of hot exhaust gases. The improvement of the accuracy of the expansion process mathematical description, compared with the currently used models, is achieved by introducing an additional empirical coefficient estimating the distribution of the cooling air along the profile of the turbine blade. The new approach to determine the theoretical power of a cooled turbine stage is also presented. The model is based on the application of three conservation laws: mass, energy and momentum. The advantage of the proposed approach is the inclusion of variable thermodynamic parameters of the cooling medium. The results were compared with the simplified models used in the literature: separate Hartsel expansion, mainstream pressure, weighted-average pressure and fully reversible. The proposed model for expansion and the determination of theoretical power allows for accurate modelling of the performance of a cooled turbine stage under varying conditions.
Źródło:
Archives of Thermodynamics; 2022, 43, 3; 3--27
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Functioning Efficiency of the Central Air-Conditioning System on the Selected Example
Autorzy:
Szlązak, Nikodem
Swolkień, Justyna
Powiązania:
https://bibliotekanauki.pl/articles/2064267.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
air conditioning
climate hazard
cooling power
klimatyzacja
zagrożenie klimatyczne
moc chłodzenia
Opis:
One of the particularly significant threats during exploitation is the climatic threat, which is associated with an increase in the overall costs that are allocated to combating it. The rise in the virgin temperature of the rock mass by 1oC increases the demand for the required cooling capacity to be taken from the air. The publication assesses the effectiveness of the air-conditioning installation by testing its operation on a selected example. The assessment of the efficiency of the air-conditioning installation for a selected hard coal mine showed that none of the five tested coolers achieved the maximum assumed rated power. The use of total power (7.5 MW) in mining excavations was less than 50% and amounted to η = 0.472%. The research showed that the main reason for obtaining low cooling parameters is the inability to locate them in the place of the highest air temperatures. The other problem is an insufficient airflow rate of cooling water supplied to the coolers at too high temperature. The above considerations indicated that the cooling power from built-in air- conditioning systems is not properly and effectively used. Improving the efficiency of its functioning is possible by proceeding research that will eliminate the above factors and by using air conditioning equipment, taking into account the periodic audit of their work to reduce electricity consumption.
Źródło:
New Trends in Production Engineering; 2020, 3, 1; 41--55
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of rational design values for gas-air coolers components of exhaust gases of marine power plants
Autorzy:
Kuznetsova, Svitlana
Kuznetsov, Valerii
Voloshyn, Andrii
Powiązania:
https://bibliotekanauki.pl/articles/34615989.pdf
Data publikacji:
2023
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
vessel
marine power plant
environmental parameters
emissions
gas-air cooler
nozzle
Opis:
Modernisation of marine power plants in the transport vessel fleet to satisfy the requirements of the International Maritime Organization is an urgent scientific and technical problem. Currently, the use of catalytic selective filters, dry and wet scrubber systems and exhaust gas recirculation for marine diesel engines is widely used for this purpose. An analysis of the use of ejection gas-air coolers is presented as an additional method of emission reduction. However, the use of such device does not neutralise the harmful emissions of power plant engines, but only increases the volume concentration of their exhaust gases. But this will help to increase the efficiency of dispersion of harmful emissions, by reducing the concentration of harmful emissions to values not exceeding the maximum permissible concentrations. Its efficiency depends on the load mode of the diesel engine. It is found that the initial concentration of harmful substances in combustion products due to their dilution with fresh air at 100% engine load is reduced by about 50%. The values of the reduction of the concentration and temperature of exhaust gases with the reduction of the engine load to 75% and 50% depending on the louvre angle are obtained. It is proved that ejection gas-air coolers can be an effective additional means for compliance with modern environmental parameters, especially when vessels are in special areas of the world’s oceans.
Źródło:
Polish Maritime Research; 2023, 3; 81-88
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Heat power determination of Dv-290 refrigerator’s evaporator on the basis of thermodynamic parameters of inlet air
Określenie mocy cieplnej parownika chłodziarki Dv-290 na podstawie parametrów termodynamicznych powietrza wlotowego
Autorzy:
Nowak, B.
Kuczera, Z.
Powiązania:
https://bibliotekanauki.pl/articles/218808.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
klimatyzacja kopalń
chłodzenie powietrza
chłodziarka sprężarkowa
moc cieplna
air conditioning of mines
air cooling
compression refrigerator
thermal power
Opis:
The present paper introduces a method for calculating the thermal power of DV-290 mining air cooler’s evaporator. The power usually differs from the nominal power given by the manufacturer. The thermodynamic parameters of cooled air are not obtained as a result of in situ measurements, but in indirect manner that is by determining the evaporation and condensation’s pressure values of R407C refrigerant. The pressure dependencies formulated as a function of air enthalpy at the evaporator’s inlet were obtained using calculations of a computer program which solves the system of equations describing heat and mass transfer in the refrigerator’s compressor on the basis of previous measurements of air performed before and after its cooling. The obtained dependencies are demonstrated in a graphical (fig. 2 and fig. 3) and analytical (the regression equations (19) and (20)) manner, the values of correlation coefficients are also presented. For the known evaporation and condensation pressure values of the refrigerant, and thus for its basic physical parameters the complete thermal power of the evaporator was determined, that is its: air cooling overt power, dehumidification occult power, temperature, relative humidity and specific humidity of air after its cooling. In addition, using the mentioned method, the capacity of DV-290 refrigerator’s evaporator is provided for the given thermodynamic parameters of air before cooling, along with air thermodynamic parameters after cooling.
W pracy zaproponowano metodę obliczania mocy cieplnej parownika górniczej chłodziarki powietrza DV-290. Moc ta zazwyczaj jest różna od mocy znamionowej podanej przez jej producenta. Wymaganą znajomość parametrów termodynamicznych schłodzonego powietrza otrzymuje się, nie jak dotychczas w wyniku ich pomiarów in situ, lecz drogą pośrednią wyznaczając najpierw wartości ciśnień parowania i skraplania czynnika chłodniczego R407C. Odpowiednie zależności tych ciśnień w funkcji jednostkowej entalpii powietrza na wlocie parownika otrzymano, na podstawie wcześniejszych pomiarów parametrów powietrza przed i po jego schłodzeniu, z obliczeń utworzonym programem komputerowym rozwiązującym układ równań opisujący wymianę ciepła i masy w chłodziarce sprężarkowej. Uzyskane zależności przedstawiono w sposób graficzny (rys. 2 i rys. 3) oraz analityczny - równania regresji (19) i (20), podając też wartości współczynników korelacji. Dla znanych wartości ciśnień parowania i skraplania czynnika chłodniczego, a więc także i jego podstawowych parametrów fizycznych, korzystając z wymienionego programu komputerowego, wyznaczono, w funkcji jednostkowej entalpii powietrza na wlocie parownika, całkowitą jego moc cieplną z podziałem na moc jawną ochładzania powietrza, utajoną moc osuszania powietrza, temperaturę, wilgotność względną i wilgotność właściwą powietrza po jego ochłodzeniu. Podano też, dla przykładowych zadanych parametrów termodynamicznych powietrza przed jego schłodzeniem obliczone wspomnianą metodą, moce parownika chłodziarki DV-290 oraz parametry termodynamiczne powietrza po schłodzeniu.
Źródło:
Archives of Mining Sciences; 2012, 57, 4; 911-920
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Equipment for Investigation of Soybean Storage with Active Ventilation
Autorzy:
Duisenova, Sholpan
Atykhanov, Aibek
Karaivanov, Dimitar
Kassymbayev, Bekbossyn
Kalym, Kabdyrakhim
Sagyndikova, Aigul
Powiązania:
https://bibliotekanauki.pl/articles/125394.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
active ventilation
air flow velocity
conveying height
flow rate
power consumption
productivity
Opis:
The article investigates and substantiates the operating modes of a container-modular equipment with active ventilation, such as specified (real) productivity, power consumption of the conveying process, as well as the use of a progressive method of controlling the humidity and temperature in soybean storage volume. Experimental equipment is developed which adequately simulates the proposed technology for soybean storage with active ventilation for the calculated data verification. The experiments confirm that the proposed experimental equipment makes it possible to adequately simulate the process of soybean storage with active ventilation and conduct experiments with the regulation of basic parameters such as productivity, power consumption, humidity, etc. using modern methods, devices and digital technologies. Experimental results are presented. Along with this, using the “Strazh Klimat” software, humidity and temperature are monitored during the experiments. Experimental data are obtained by the use of which it is possible to establish the dependence of the conveying height on the air flow velocity.
Źródło:
Journal of Ecological Engineering; 2020, 21, 3; 117-127
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected characteristics of the electric propulsion system of aircraft as found out from the ground-based laboratory tests
Autorzy:
Jakielaszek, Z.
Nowakowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/242946.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
electric motor
physical parameters of the air
efficiency and power of electric motor
Opis:
The paper is a discussion on ground-based laboratory tests of the aircraft’s electric propulsion system. The tests were intended to find relationships between environmental conditions and characteristics of the aircraft electric motor. The object under examination was a brushless DC motor AXI 2820/14 of 360 W power. Presented and discussed is the AFIT-made test bench that enables suitable, pre-planned experiments to be carried out. Discussed are also procedures of taking measurements of electric motor characteristics, followed with discussion of results. Presented selected issues of parametric description of gained results. With measurements as the basis, the relationships, first, between the electric motor’s efficiency and temperature, and second, between both the applied power and the power output (effective power) and the ambient temperature have been found. The most important findings of the testing work are, first, that the pressure does not affect the characteristics of the electric motor’s performance and second, determination of how temperature affects these characteristics. The results gained have formed the basis for the most vital flight parameters of electrically driven aircraft to be found, including the energy consumption essential for the flight range and endurance. All these findings give grounds for standardization calculations that consist in recalculation of characteristics determined in the course of aircraft flight-testing. Because of their representativeness, they also prove good illustrative examples to demonstrate properties of aircraft’s electric propulsion system.
Źródło:
Journal of KONES; 2014, 21, 4; 203-210
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies