Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wieczorek, C" wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
Chemical changes in the fat fraction during storage of long life sweet baked products
Zmiany chemicznych wskaźników tłuszczu w procesie przechowywania trwałego pieczywa cukierniczego
Autorzy:
Sroczyński, A.
Wieczorek, C.
Powiązania:
https://bibliotekanauki.pl/articles/1401994.pdf
Data publikacji:
1990
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
fat changes
storage
long life sweet baked products
Opis:
Changes in the fat fraction of durable sweet baked products were assessed by determining contents of peroxides, cinnamic and malonic aldehydes, fatty acids, and the ester number. Three kinds of biscuits and one kind of wafer were studied in various temperature and air humidity conditions over a period of four months.
Zbadano zakres zmian chemicznych zachodzących w lipidach trwałego pieczywa cukierniczego, to jest trzech rodzajach herbatników, przekładanych, czekoladowanych i laminowanych oraz waflach przekładanych. Badania przeprowadzono w okresach jednego, dwóch, trzech i czterech miesięcy przy różnych parametrach przechowywania, tzn. w temp. 10, 20, 30°C i wilgotności względnej powietrza od 50% do 90%. Zmiany zachodzące we frakcji tłuszczowej wymienionych wyrobów kontrolowano na podstawie analizy zawartości nadtlenków, aldehydów cynamonowego i malonowego, wolnych kwasów tłuszczowych, składu wszystkich kwasów tłuszczowych oraz liczby estrowej. Badane wskaźniki chemiczne tłuszczu ujawniły częściowo korelację z postępującymi w czasie przechowywania pieczywa cukierniczego procesami degradacyjnymi. zawartość nadtlenków (rys. 1) i liczba benzydynowa wyrażona zawartością aldehydu cynamonowego (rys. 2) wykazały z upływem czasu przechowywania tendencje wzrostowe, tym większe im wyższa temperatura i wilgotność względna powietrza. Charakterystyczne są małe zmiany liczby tiobarbiturowej wyrażonej zawartością aldehydu malonowego (tab. 1), liczby kwasowej tłuszczu (tab. 2) oraz składu ilościowego wszystkich kwasów tłuszczowych (tab. 3).
Źródło:
Acta Alimentaria Polonica; 1990, 16(40), 3-4; 129-136
0137-1495
Pojawia się w:
Acta Alimentaria Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of crude oils pressed and extracted from seeds of Cucurbita pepo
Autorzy:
Wieczorek, C.
Kowalski, A.
Zalewski, S.
Powiązania:
https://bibliotekanauki.pl/articles/1371704.pdf
Data publikacji:
1993
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
oxidative stability
oil
pumpkin seed
seed
nutritional value
crude oil
stability
human nutrition
technological value
fatty acid
quality
Cucurbita pepo
composition
Źródło:
Polish Journal of Food and Nutrition Sciences; 1993, 02, 2; 17-24
1230-0322
2083-6007
Pojawia się w:
Polish Journal of Food and Nutrition Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of culinary processes on nitrate, nitrite and carotenoids content in carrot
Wplyw procesow kulinarnych na zawartosc azotanow, azotynow i karotenoidow w marchwi
Autorzy:
Wieczorek, C.
Motyka, M.
Pecka, W.
Zalewski S., S.
Powiązania:
https://bibliotekanauki.pl/articles/1372436.pdf
Data publikacji:
1994
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
obrobka kulinarna
azotany
analiza zywnosci
zywnosc
marchew
gotowanie
moczenie
karotenoidy
azotyny
zwiazki azotowe
warzywa
zywienie czlowieka
Opis:
The aim of this paper was to determine the best conditions for a culinary process, in which nitrates and nitrite are removed from carrot at a possibly high degree and the losses in total carotenoids and ß-carotene are possibly small. lt was found that commercial carrot exhibited relatively high concentration of nitrates (330 mg KNO:Jkg carrot) at a presence of nitrites (0.6 mg NaNO2/kg). The highest concentration of nitrates and nitrites (290 mg KNO:Jkg and 0.64 mg NaNO2Jkg) contained the core, followed by the parenchyma (58.8 mg KNO:Jkg and 0.48 mg NaNOifkg), and the peel (20.6 mg KNO:Jkg and 0.36 mg NaNOifkg). The concentration of nitrates and nitrites in carrot changed upon the culinary processes and depended on their performance. Cooking decreased the content of these compounds at the highest degree (KNO3 by 56.9% and NaNO2 by 58.6%). Tue smaller decreases (KNO3 by 20.3% and NaNO2 by 58.3%) resulted from soaking of peeled carrot. The storage of peeled carrot in water appeared more expedient than on air because of a decrease in their content of nitrates an.d nitrites. In morsel-cut raw and cooked carrot stored at +4°C the content of nitrates decreased by 14.3% to 23.6% while that of nitrites increased by 125% to 248%. The content of total carotenoids and ß-carotene did not change much upon culinary processing.
Źródło:
Polish Journal of Food and Nutrition Sciences; 1994, 03, 3; 127-137
1230-0322
2083-6007
Pojawia się w:
Polish Journal of Food and Nutrition Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quantitative analysis of stability of 9%Cr steel microstructure after long-term ageing
Autorzy:
Golański, G.
Jasak, J.
Zieliński, A.
Kolan, C.
Urzynicok, M.
Wieczorek, P.
Powiązania:
https://bibliotekanauki.pl/articles/353244.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
high-chromium martensitic steels
microstructure
carbide precipitation
Opis:
The paper presents the results of research on the microstructure of martensitic X10CrMoVNb9-1 (P91) and X13CrMoCo- VNbNB9-2-1 (PB2) steel subject to long-term ageing at the temperature of 620°C and holding times up to 30 000 hours. The microstructural tests of the examined steel types were performed using a scanning microscope Joel JSM - 6610LV and a transmission electron microscope TITAN 80 - 300. The stability of the microstructure of the investigated steels was analyzed using a quantitative analysis of an image, including measurements of the following: the density of dislocations inside martensite/subgrain laths, the width of martensite laths, and the mean diameter of precipitates. It has been concluded that during long-term ageing, the microaddition of boron in PB2 steel significantly influenced the slowing of the process of degradation of the martensitic steel microstructure, as a result of slowing the process of coagulation of M23C6 carbides and Laves phase. It had a favorable effect on the stabilization of lath microstructure as a result of retardation of the processes of recovery and polygonization of the matrix.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 1; 263-271
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Method to Produce Linearly Polarized Positrons and Positronium Atoms with the J-PET Detector
Autorzy:
Mohammed, Muhsin
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, ---
Skurzok, M.
Silarski, M.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1030045.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
41.75.Fr
41.75.Ht
77.22.Ej
36.10.Dr
85.75.Mm
87.57.uk
Opis:
A method for creating linearly polarized positrons and ortho-positronium (o-Ps) atoms with the J-PET detector is presented. The unique geometry and properties of the J-PET tomography enable one to design a positron source such that the quantization axis for the estimation of the linear polarization of produced o-Ps can be determined on the event by event basis in a direction of the positron motion. We intend to use ²²Na or other β⁺ decay isotopes as a source of polarized positrons. Due to the parity violation in the beta decay, the emitted positrons are longitudinally polarized. The choice of the quantization axis is based on the known position of the positron emitter and the reconstructed position of the positronium annihilation. We show that the J-PET tomography is equipped with all needed components.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1486-1489
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Procedure of the Positronium Lifetime Spectra for the J-PET Detector
Autorzy:
Dulski, K.
Zgardzińska, B.
Białas, P.
Curceanu, C.
Czerwiński, E.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, Shivani
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033298.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.05.Kf
13.30.Ce
14.60.-z
78.47.-p
Opis:
Positron annihilation lifetime spectroscopy has shown to be a powerful tool to study the nanostructures of porous materials. Positron emission tomograph is a device allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the Jagiellonian PET will allow positron annihilation lifetime spectroscopy in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the Jagiellonian PET software. We compare its performance with the standard program LT 9.0 by using positron annihilation lifetime spectroscopy data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1637-1640
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time Calibration of the J-PET Detector
Autorzy:
Skurzok, M.
Silarski, M.
Alfs, D.
Białas, P.
Shivani, S.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033283.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.fb
36.10.Dr
11.30.Er
24.80.+y
Opis:
The Jagiellonian positron emission tomograph project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time-and high angular resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a ²²Na source and a small detector providing common reference time for synchronization of all the modules.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1641-1644
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of J-PET detector spatial resolution
Autorzy:
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Alfs, D.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, M.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Shivani, -
Silarski, M.
Skurzok, M.
Sharma, N.
Sharma, S.
Shopa, R.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057928.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1645-1648
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Human tissue investigations using PALS technique - free radicals influence
Autorzy:
Jasińska, B.
Zgardzińska, B.
Chołubek, G.
Pietrow, M.
Gorgol, M.
Wiktor, K.
Wysogląd, K.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Hiesmayr, B.
Jodłowska-Jędrych, B.
Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiktor, H.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057941.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
positron annihilation
positronium
free radicals
tissues
uterine leiomyomas
Opis:
The positron annihilation lifetime spectroscopy was applied to the samples of the human uterine leiomyomas and the normal myometrium tissues taken from the selected place of the uterus during a surgery. The method indicated differences in values of the measured positron annihilation lifetime spectroscopy parameters (lifetimes and intensities) between healthy and diseased tissue samples. The additional measurements were performed either in darkness or in presence of visible light which influenced the free radicals present in both kind of tissues and, as a result, made changes in free annihilation and o-Ps decay lifetime and intensity values.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1556-1558
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies