Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Darago, Adam" wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
The effect of exposure route on the distribution and excretion of hexachloronaphthalene in rats
Autorzy:
Kilanowicz, Anna
Daragó, Adam
Skrzypińska-Gawrysiak, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2180102.pdf
Data publikacji:
2012-06-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
hexachloronaphthalene
distribution
excretion
rat
Opis:
Objectives: Polychlorinated naphthalenes (PCNs), like other persistent organic pollutants (POPs), are widespread, global environmental contaminants. These compounds still represent a great environmental problem, mostly because of the risk of secondary air pollution. They are characterized by long durability and tendency to bioaccumulate, which means that they are practically ubiquitous in all environmental media and ecosystems. The aim of this study was to investigate the distribution and excretion of hexachloronaphthalene (HxCN) in rats following a single intraperitoneal or intragastrical administration. Materials and Methods: Experiments were performed on male outbred Wistar rats with body weight of 220–240 g. They were given [¹⁴C]-HxCN intraperitoneally (i.p.) or intragastrically (p.o.) in a single dose of 0.3 mg (150 kBq) per rat. The distribution of radioactivity in blood and selected organs or tissues, as well as urine and faeces excretion were traced following the administration. Results: The decline of [¹⁴C]-HxCN in plasma was biphasic and the calculated half-lives for phases I and II were ~6 and 350 h, respectively. Following 120 h after administration, ~51% (intragastrical) and ~34% (intraperitoneal) of the dose were excreted with faeces. Regardless of the administration route, the highest HxCN concentrations were found in liver and adipose tissue, where the compound showed high retention: the highest retention in liver was found 24 h after intragastrical (32%) and intraperitoneal (38%) administration while in adipose tissue ~30% retention was observed 120 h after HxCN administration regardless of its route. Conclusions: Following the calculation of the balance of total [¹⁴C]-HxCN excreted and stored, it was found that hexachloronaphthalene belongs to the compounds of a slow turnover rate, and in the case of repeated exposure it may accumulate in the rat body.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2012, 25, 2; 185-195
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of ultra-performance liquid chromatography (UPLC) with fluorescence detector (FLD) method for the quantitative determination of selected neurotransmitters in rat brain
Autorzy:
Stragierowicz, Joanna
Daragó, Adam
Brzeźnicki, Sławomir
Kilanowicz, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2164059.pdf
Data publikacji:
2017-07-26
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
brain
neurotransmitters
glutamate
fluorescence detector
ultra-performance liquid chromatography
γ-aminobutyric acid
Opis:
Background Glutamate (Glu) and γ-aminobutyric acid (GABA) are the main neurotransmitters in the central nervous system for excitatory and inhibitory processes, respectively. Monitoring these neurotransmitters is an essential tool in establishing pathological functions, among others in terms of occupational exposure to toxic substances. Material and Methods We present modification of the HPLC (high-performance liquid chromatography) to the UPLC (ultra-performance liquid chromatography) method for the simultaneous determination of glutamate and γ-aminobutyric acid in a single injection. The isocratic separation of these neurotransmitter derivatives was performed on Waters Acquity BEH (ethylene bridged hybrid) C18 column with particle size of 1.7 μm at 35°C using a mobile phase consisting of 0.1 M acetate buffer (pH 6.0) and methanol (60:40, v/v) at a flow rate of 0.3 ml/min. The analytes were detected with the fluorescence detector (FLD) using derivatization with o-phthaldialdehyde (OPA), resulting in excitation at 340 nm and emission at 455 nm. Results Several validation parameters including linearity (0.999), accuracy (101.1%), intra-day precision (1.52–1.84%), inter-day precision (2.47–3.12%), limit of detection (5–30 ng/ml) and quantification (100 ng/ml) were examined. The developed method was also used for the determination of these neurotransmitters in homogenates of selected rat brain structures. Conclusions The presented UPLC-FLD is characterized by shorter separation time (3.5 min), which is an adaptation of the similar HPLC methods and is an alternative for more expensive references techniques such as liquid chromatography coupled with tandem mass-spectrometry (LC-MS/MS) methods. Med Pr 2017;68(5):583–591
Źródło:
Medycyna Pracy; 2017, 68, 5; 583-591
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of cadmium on the coagulation and fibrinolytic system in women with uterine endometrial cancer and myoma
Autorzy:
Nasiadek, Marzenna
Kilanowicz, Anna
Darago, Adam
Lazarenkow, Andrzej
Michalska, Marta
Powiązania:
https://bibliotekanauki.pl/articles/2179784.pdf
Data publikacji:
2013-04-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
cadmium
coagulation cascade
Endometrial Cancer
fibrinolysis
myoma
Opis:
Objectives: Cadmium (Cd) is a persistent and widespread environmental pollutant, which may constitute a potential risk factor for hormone-dependent tumors such as endometrial cancer. The vascular endothelium is an important target of cadmium toxicity, which may interfere with the coagulation cascade and fibrinolytic system. The aim of this research was to investigate whether in female patients with uterine endometrial cancer or myoma in comparison to healthy women, the concentration of cadmium in blood affects the process of coagulation and fibrinolysis. Materials and Methods: The study group comprised 91 women: 35 healthy (A-control), 39 with uterine myoma (B) and 17 with endometrial cancer (C), in which blood cadmium concentrations (BCd), coagulation and selected fibrinolysis parameters in plasma were assayed. Results: In the women with myoma and especially in those with endometrial cancer disturbances in coagulation and fibrinolysis were detected when compared to the healthy women. In the group of women with endometrial cancer significant changes in prothrombin index, levels of fibrinogen, fibrin D-dimer and t-PA were observed. Whereas, in the patients with myoma significant changes in prothrombin time, index of vWillebrand Factor and fibrin D-dimer level were noted. Mean BCd concentrations in subsequent groups were as follows: B - 0.91±0.81; C - 0.78±0.45 μg Cd/l and did not differ significantly in comparison with the control group (0.86±0.35 μg Cd/l). However, in each study group smokers had approximately twice as high BCd as non-smokers. Studies also showed significant associations between BCd and fibrinogen level and thrombin time among the women with myoma and endometrial cancer, as well as in healthy women. Moreover, thrombin time significantly correlated with fibrinogen level in the women studied. Conclusions: In the patients with myoma and especially in these with endometrial cancer disturbances in coagulation and fibrinolysis parameters leading to hypercoagulability were detected. Exposure to cadmium can be one of the factors inducing these changes.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2013, 26, 2; 291-301
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies