Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Czerwiński, D." wg kryterium: Autor


Tytuł:
Spectral methods in Polish emotional speech recognition
Autorzy:
Powroźnik, P.
Czerwiński, D.
Powiązania:
https://bibliotekanauki.pl/articles/102087.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
artificial neural network
spectrogram
emotional speech recognition
Opis:
In this article the issue of emotion recognition based on Polish emotional speech signal analysis was presented. The Polish database of emotional speech, prepared and shared by the Medical Electronics Division of the Lodz University of Technology, has been used for research. Speech signal has been processed by Artificial Neural Networks (ANN). The inputs for ANN were information obtained from signal spectrogram. Researches were conducted for three different spectrogram divisions. The ANN consists of four layers but the number of neurons in each layer depends of spectrogram division. Conducted researches focused on six emotional states: a neutral state, sadness, joy, anger, fear and boredom. The averange effectiveness of emotions recognition was about 80%.
Źródło:
Advances in Science and Technology. Research Journal; 2016, 10, 32; 73-81
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis of finite state machines for CPLDs
Autorzy:
Czerwiński, R.
Kania, D.
Powiązania:
https://bibliotekanauki.pl/articles/930019.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
synteza logiczna
FSM
kodowanie stanów
optymalizacja logiczna
CPLD
logic synthesis
state assignment
logic optimization
Opis:
The paper presents a new two-step approach to FSM synthesis for PAL-based CPLDs that strives to find an optimum fit of an FSM to the structure of the CPLD. The first step, the original state assignment method, includes techniques of two-level minimization and aims at area minimization. The second step, PAL-oriented multi-level optimization, is a search for implicants that can be shared by several functions. It is based on the graph of outputs. Results of experiments prove that the presented approach is especially effective for PAL-based CPLD structures containing a low number of product terms.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2009, 19, 4; 647-659
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of degree of conversion of polymer-based orthodontic adhesive resins
Ocena stopnia konwersji ortodontycznych żywic adhezyjnych na bazie polimerów
Autorzy:
Kuśmierczyk, D.
Czerwiński, M.
Tykarska, M.
Małkiewicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/947084.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
orthodontic adhesives
photopolymerization
degree of conversion
statistical analysis
ortodontyczne materiały adhezyjne
fotopolimeryzacja
stopień konwersji
analiza statystyczna
Opis:
Degree of conversion (DC) of selected currently used orthodontic adhesive materials, after their polymerization with dental curing light, were investigated in laboratory conditions. Samples of four orthodontic adhesives (Contec LC, Transbond XT, Transbond Plus and Resilience) were prepared in Teflon matrices and then formed into the thickness of 1 mm. After the baseline measurement of crosslinking of the materials with Fourier transform infrared spectroscopy (FT-IR) the samples were cured with treatment light, and then 1 and 24 h after the completion of the photopolymerization process, the values of DC were evaluated. The results were analyzed using the Statistica 8.0 software package. In the process of hypothesis testing the level of significance was assumed at α = 0.05. The statistical analysis yielded significant differences between DC values of orthodontic adhesives tested in both time periods and a significant increase after 24 h storage of the studied orthodontic adhesive systems. It was stated that DC values of the visible light-cured orthodontic adhesives assessed in the present study depend of the type of the composite material. A significant increase in DC occurring with extended period of observation proves that polymerization of dental adhesive materials is a long-term process.
Przeprowadzono w warunkach laboratoryjnych badania stopnia konwersji (DC) wybranych, stosowanych współcześnie ortodontycznych materiałów adhezyjnych po ich polimeryzacji pod wpływem światła widzialnego lampy stomatologicznej. Próbki czterech klejów ortodontycznych (Contec LC, Transbond XT, Transbond Plus i Resilience) przygotowano w teflonowych matrycach, a następnie uformowano do grubości 1 mm. Po wykonaniu za pomocą spektroskopii w podczerwieni z transformacją Fouriera (FT-IR) pomiaru początkowego usieciowania próbek, poddawano je działaniu lampy zabiegowej, a następnie po 1 i 24 h od zakończenia procesu fotopolimeryzacji wyznaczano wartości DC. Uzyskane wyniki analizowano korzystając z pakietu statystycznego Statistica 8.0. W procesie testowania hipotez statystycznych przyjęto poziom istotności α = 0,05. Analiza statystyczna wykazała istotne różnice pomiędzy wartościami DC badanych klejów ortodontycznych wyznaczonymi po upływie 1 i 24 h oraz istotny wzrost DC podczas 24-godzinnego przechowywania ocenianych próbek. Stwierdzono, że wartość DC ocenianych układów adhezyjnych polimeryzowanych światłem widzialnym zależy od rodzaju materiału. Istotny wzrost wartości DC zachodzący wraz z wydłużeniem czasu obserwacji może świadczyć o tym, że polimeryzacja stomatologicznych materiałów adhezyjnych jest procesem długotrwałym.
Źródło:
Polimery; 2017, 62, 6; 466-471
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-legislated emissions and PN of two passenger cars with gasoline-butanol blends
Autorzy:
Czerwinski, J.
Comte, P.
Engelmann, D.
Bonsack, P.
Powiązania:
https://bibliotekanauki.pl/articles/134045.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
alternative fuels
alcohols
nanoparticles
ammonia
cold start
emissions gasoline
alternatywne paliwa
alkohol
nanocząstki
amoniak
zimny rozruch
emisja benzyny
Opis:
Increasing the sustainability of individual transportation and replacing a part of fossil energy in traffic by renewable energy carriers are worldwide important objectives. Bioalcohols are generally recognized as one of very useful alternatives. The global share of bioethanol used for transportation is continuously increasing. Butanol, a four-carbon alcohol, is considered in the last years as an interesting alternative fuel, both for diesel and for gasoline application. Its advantages for engine operation are: good miscibility with gasoline and diesel fuels, higher calorific value than ethanol, lower hygroscopicity, lower corrosivity and possibility of replacing aviation fuels. In the present work, the emissions of two gasoline vehicles – with older and with newer technology – were investigated in dynamic-, stationary and cold start operation.
Źródło:
Combustion Engines; 2018, 57, 1; 64-72
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Landslides survey in the northeastern Poland
Autorzy:
Ilcewicz-Stefaniuk, D.
Czerwiński, T.
Koryczan, A.
Targosz, P.
Stefaniuk, M.
Powiązania:
https://bibliotekanauki.pl/articles/1182891.pdf
Data publikacji:
2005
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
osuwiska
ruchy masowe
inwentaryzacja
pomiary geodezyjne
tomografia opornościowa
północno-wschodnia Polska
landslides
mass movements
inventory
geodetic survey
resistivity geotomography
north-eastern Poland
Opis:
Badania procesów osuwiskowych na obszarze północno-wschodniej Polski wykonano w ramach tematu: Rejestracja i inwentaryzacja naturalnych zagrożeń geologicznych (ze szczególnym uwzględnieniem osuwisk oraz innych zjawisk geodynamicznych) na terenie całego kraju, zamówionego przez Ministerstwo Środowiska i finansowanego przez Narodowy Fundusz Ochrony Środowiska i Gospodarki Wodnej. Skala obserwowanych zjawisk, znacznie większa od przewidywanej, spowodowała konieczność koncentracji badań na wybranych obszarach i w strefach szczególnie zagrożonych. Obok osuwisk i innych skutków powierzchniowych ruchów masowych, zinwentaryzowanych w postaci kart dokumentacyjnych, zaobserwowano i odnotowano do udokumentowania liczne obiekty o mniejszych rozmiarach lub o mniejszej skali zagrożenia. Dla wybranych osuwisk, stwarzających istotne zagrożenie dla otoczenia, wykonano dokładne pomiary geodezyjne, badania geoelektryczne metodą tomografii opornościowej i płytkie wiercenia geologiczne. Celem tych prac było przygotowanie wstępnych danych do opracowania cyfrowych modeli osuwisk i ich wstępne rozpoznanie, poprzedzające ewentualne rutynowe monitorowanie procesów osuwiskowych. Biorąc pod uwagę zespoły osuwisk o podobnej genezie i podobnych uwarunkowaniach geomorfologicznych i geologicznych wyodrębniono następujące strefy objęte względnie intensywnymi procesami osuwiskowymi, tj. wybrzeże Bałtyku z aktywnymi procesami osuwiskowymi wywołanymi abrazją morską i obszar pojezierzy północnej Polski z licznymi wzgórzami morenowymi.
Źródło:
Polish Geological Institute Special Papers; 2005, 20; 67--73
1507-9791
Pojawia się w:
Polish Geological Institute Special Papers
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
NOX-reduction on HD-vehicles-low cost quality check
Autorzy:
Czerwinski, J.
Zimmerli, Y.
Mayer, A.
Heeb, N.
Berger, H.
D‘Urbano, G.
Powiązania:
https://bibliotekanauki.pl/articles/246300.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
Diesel particle filter
regeneration of DPF
non-legislated emissions
selective catalytic reduction SCR
NOx-reduction
SCR-quality testing
on vehicle testing
Opis:
The NOx reduction of recent HD-vehicle is performed mostly by means of the selective catalytic reduction SCR. There are some manufactures and some applications of SCR as retrofit systems (mostly for the low emission zones LEZ and in combination with a DPF). In charge of Swiss authorities AFHB investigated several SCR-systems, or (DPF+SCR)-systems on HD-vehicles and proposed a simplified quality test procedure of those systems. This procedure can especially be useful for the admission of retrofit systems but it can also be helpful for the quality check of OEM-systems. In the present paper the test procedures will be described and some examples of specific results will be presented. As general conclusions it can be stated: – the foundations for the quality verification procedures of SCR-systems are established, – the SCR-systems are not active at lower temperatures < 200°C, – SCR-testing on vehicle is a simple & low-cost tool for quality check, – the overall average NOx reduction rate depends on the operating profile of the vehicle – for low-load, for cold operation and for interrupted operation (HEV) there are lower NOx reduction efficiencies.
Źródło:
Journal of KONES; 2013, 20, 2; 61-68
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing and evaluating real driving emissions with PEMS
Autorzy:
Czerwinski, J.
Zimmerli, Y.
Hüssy, A.
Engelmann, D.
Bonsack, P.
Remmele, E.
Huber, G.
Powiązania:
https://bibliotekanauki.pl/articles/133005.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
RDE evaluation
RDE with Ethanol
PN PEMS
simulation of slope and normality of RDE results
ocena RDE
rzeczywista emisja cząstek
przenośne systemy pomiaru emisji
Opis:
Testing of real driving emissions (RDE) with portable emission measuring system (PEMS) in an appropriate road circuit became an obligatory element of new type approval of passenger cars since September 2017. In several projects the Laboratory for Exhaust Emissions Control (AFHB) of the Berne University of Applied Sciences (BFH) performed comparisons on passenger cars with different PEMS’s on chassis dynamometer and on road, considering the quality and the correlations of results. Particle number measuring systems (PN PEMS) were also included in the tests. The present paper informs about influences of E85 on RDE on two flex-fuel-vehicles, discusses some aspects of different ways of evaluation with different programs, shows comparison of different types of PN PEMS and represents the effects of simulation of slope on the chassis dynamometer.
Źródło:
Combustion Engines; 2018, 57, 3; 17-25
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radon Hazards in Relation to Elemental and Isotope Composition of the Geological Structures in the Lubelskie Voivodeship
Autorzy:
Gazda, L.
Połednik, B.
Czerwiński, J.
Kozak, K.
Mazur, J.
Grządziel, D.
Dudzińska, M.
Powiązania:
https://bibliotekanauki.pl/articles/123882.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
rocks
radon sources
emanations
radon exhalations
indoor environment
Opis:
The study involved investigation of the relationship between the radon concentrations in the ground air – and thus in the indoor air – and the geological structure of the Lubelskie Voivodeship (eastern Poland). Both passive and active methods were used for measuring the radon concentrations in coal, phosphate and chalk mines, caves, wells as well as indoor environments. The study also included elemental, uranium and lead isotope analyses of rocks. The performed research showed that Paleogene and Mesozoic sedimentary rocks rich in radionuclides are the sources of radon in the Lubelskie Voivodeship. In the case of the buildings located in proximity to such rocks, characterized by relatively high radon exhalations, radon remediation methods are recommended. Already at the designing stage of buildings, the measures which protect against the hazardous radon gas should be applied.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 45-49
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
TEM Characterization of Polysilicon and Silicide Fin Fabrication Processes of FinFETs
Autorzy:
Ratajczak, J.
Łaszcz, A.
Czerwinski, A.
Kątcki, J.
Tang, X.
Reckinger, N.
Yarekha, D.
Larrieu, G.
Dubois, E.
Powiązania:
https://bibliotekanauki.pl/articles/1807511.pdf
Data publikacji:
2009-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
85.40.-e
68.37.Lp
Opis:
The transmission electron microscopy characterization of various silicon and silicide fin structures intended for application in FinFET devices has been performed. The results showed that transmission electron microscopy is a very useful tool for optimization of manufacturing processes of fin nanostructures in FinFETs.
Źródło:
Acta Physica Polonica A; 2009, 116, S; S-89-S-91
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Framework for the J-PET Scanner
Autorzy:
Krzemień, W.
Gajos, A.
Gruntowski, A.
Stola, K.
Trybek, D.
Bednarski, T.
Białas, P.
Czerwiński, E.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402621.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.nf
87.57.uk
29.85.-c
Opis:
J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1491-1494
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Processing optimization with parallel computing for the J-PET scanner
Autorzy:
Krzemień, W.
Bała, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Stola, K.
Strzelecki, A.
Trybek, D.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/148285.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
data aquisition system (DAQ)
parallel computing
TOF-PET
Opis:
The Jagiellonian Positron Emission Tomograph (J-PET) collaboration is developing a prototype time of flight (TOF)-positron emission tomograph (PET) detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast fi eld programmable gate array (FPGA)-based front-end electronics and the data acquisition system, as well as low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in the case of a large acceptance detector that works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 745-748
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time Calibration of the J-PET Detector
Autorzy:
Skurzok, M.
Silarski, M.
Alfs, D.
Białas, P.
Shivani, S.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033283.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.fb
36.10.Dr
11.30.Er
24.80.+y
Opis:
The Jagiellonian positron emission tomograph project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time-and high angular resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a ²²Na source and a small detector providing common reference time for synchronization of all the modules.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1641-1644
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Autorzy:
Sharma, N. G.
Silarski, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Słomski, A.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/146937.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
J-PET detector
Mahalanobis distance
time resolution
threshold levels
Opis:
The J-PET detector being developed at the Jagiellonian University is a positron emission tomograph composed of the long strips of polymer scintillators. At the same time, it is a detector system that will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit time and hit position of the gamma quantum. In order to take advantage of this fact, a dedicated sampling front-end electronics that enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity, we use the Mahalanobis distance. The achievable position and time resolution depend on the number and values of the threshold levels at which the signal is sampled. A reconstruction method as well as preliminary results are presented and discussed.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 765-769
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of J-PET detector spatial resolution
Autorzy:
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Alfs, D.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, M.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Shivani, -
Silarski, M.
Skurzok, M.
Sharma, N.
Sharma, S.
Shopa, R.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057928.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1645-1648
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
GPU Accelerated Image Reconstruction in a Two-Strip J-PET Tomograph
Autorzy:
Białas, P.
Kowal, J.
Strzelecki, A.
Bednarski, T.
Czerwiński, E.
Gajos, A.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krzemień, W.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402623.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.nf
87.57.uk
Opis:
We present a fast GPU implementation of the image reconstruction routine, for a novel two strip PET detector that relies solely on the time of flight measurements.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1500-1504
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies