Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water treatment sludge" wg kryterium: Wszystkie pola


Tytuł:
Recovery of Alum from Surabaya Water Treatment Sludge using Electrolysis with Carbon-Silver Electrodes
Autorzy:
Barakwan, Rizkiy Amaliyah
Hardina, Tyta Try
Trihadiningrum, Yulinah
Bagastyo, Arseto Yekti
Powiązania:
https://bibliotekanauki.pl/articles/123042.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
alum
drinking water
electrolysis
recovery
sludge
Opis:
Untreated alum sludge from Surabaya water treatment plant (WTP), which contained high concentration of alum was directly discharged into Surabaya River. It might cause problems because of the accumulation of aluminum in the lower part of the river. Alum could be recovered from the drinking water sludge using the electrolysis method. Aims of this study were to determine the optimum pH and electrical current for electrolysis using carbon-silver electrodes to recover aluminum coagulant from the sludge, and to determine the amount of the recovered alum. The sludge was acidified prior to electrolysis. Acidification was done by adding sulfuric acid at pH 3 and 4. Polarization test was conducted at 100, 200, and 300 mA, in order to determine the optimum electrical current. The electrolysis was performed in one compartment batch recirculation reactor, using silver as cathode and carbon as anode for 10 hours. Values of pH were measured every hour. The precipitated matter in the cathode was weighed, and analysed by means of Inductively Coupled Plasma. The optimum conditions of the electrolysis were achieved at initial pH 3 and electrical current 300 mA. The electrolysis resulted in the highest precipitate of 2.6112 g in the cathode.
Źródło:
Journal of Ecological Engineering; 2019, 20, 7; 126-133
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of nanofiltration membranes to concentrate and recover leached aluminum from acidified water treatment sludge
Autorzy:
Cheng, W. P.
Chen, P. H.
Tian, D. R.
Yu, R. F.
Fu, C. H.
Powiązania:
https://bibliotekanauki.pl/articles/208030.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water purification
nanofiltration
acidic solutions
leaching
roztwory kwaśne
oczyszczanie wody
nanofiltracja
ługowanie
glin
Opis:
The recovery of aluminum from water purification sludge is usually performed by making the solution acidic or basic. However, for economic reasons and reasons of safety, excessive doses of acid or base should not be utilized. Accordingly, the aluminum concentration in the leached solution is typically limited, thus the recovered aluminum cannot be directly reused as a coagulant. A nanofiltration (NF) membrane can be used in the acidic solution to concentrate high-valence metal ions. There-fore, in this work, H2SO4 was utilized to leach Al3+ ions from water purification sludge. Then, the Al3+ ion solution was concentrated using a low-price NF membrane. The effect of natural organic matter on the Al3+ ion concentrating efficiency in the filtration process has been elucidated. Experimental results reveal that Al3+ ions were effectively prevented from passing through the NF membrane, enabling a highly concentrated aluminum solution to be obtained. However, the presence of organic compounds may reduce the efficiency of the concentration of Al3+ ions in the solution.
Źródło:
Environment Protection Engineering; 2016, 42, 3; 19-32
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Organic Compounds of Natural Origin in Sludge from Waste-Water Treatment Plant
Związki organiczne pochodzenia naturalnego w osadach z oczyszczalni ścieków
Autorzy:
Kucharova, J.
Raclavska, H.
Raclavsky, K.
Powiązania:
https://bibliotekanauki.pl/articles/319169.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Przeróbki Kopalin
Tematy:
waste–water treatment sludge
organic compounds
humification
mineralization
Py-GC/MS
przeróbka ścieków i osadów
związki organiczne
humifikacja
mineralizacja
Opis:
Organic compounds of natural origin were analyzed in three types of sludge produced by waste water treatment plant – limed sludge with 12 % of CaO, limed sludge with 6% of CaO and sludge without processing. Analysis was performed by pyrolytic gas chromatography with mass spectrometry detection (Py-GC/MS). The main component pf natural origin in waste-water treatment sludge were determined. They comprise compounds form the following groups: fatty acids and their methylesters, steroids, substances derived from polysaccharides, substances derived from lignin, compounds with nitrogen (both heterocyclic and aliphatic), substances with so called non-specific origin (toluene, styrene, acetic acid, methylphenols and phenols). Interpretation was attempted for identification of organic compounds sources as well as determination of humification and mineralization degree. The ratio benzene/toluene was used as the criterion for humification in waste-water treatment sludge. Benzene is derived from degradation of condensed aromatic structure, toluene is derived from both condensed aromatic structures and pseudostable organic matter. The ratio furfural/pyrolle was used of expression of mineralization degree of organic matter. Furfural is a product of labile organic matter (saccharides) while pyrolle originates from stable organic matter (humified components containing nitrogen). Compared with non-limed sludges, limed sludges have higher rate of decomposition of organic matter as well as subsequent mineralization. Limed sludges accumulate more compounds derived from lignine which is caused by more intensive decomposition of polysaccharides. From the point of view of utilization in agriculture, limed sludge is the most suitable sludge produced by waste-water treatment.
Przeanalizowano związki organiczne pochodzenia naturalnego w trzech typach osadów wytwarzanych przez oczyszczalnie ścieków - szlam wapnowany zawierający 12% CaO, szlam wapnowany z 6% CaO i osady nieprzetworzone. Analizę przeprowadzono za pomocą pirolitycznej chromatografii gazowej ze spektrometrią masową (Py-GC / MS). Określono główne składniki pochodzenia naturalnego w osadach z oczyszczalni ścieków. Stanowią one związki z następujących grup: kwasy tłuszczowe oraz ich estry metylowe, steroidy, substancje pochodzących z polisacharydów, substancje pochodzące z ligniny, związki z azotem (zarówno heterocyklicze i alifatyczne), substancje o tzw. niespecyficznym pochodzeniu (toluen, styren, kwas octowy, metylofenole i fenole). Przedstawiono próbę identyfikacji źródeł związków organicznych, a także określenia stopnia humifikacji i mineralizacji. Stosunek benzenu do toluenu stosuje się w osadach z oczyszczalni ścieków jako kryterium humifikacji. Benzen jest pochodną z degradacji skondensowanej struktury aromatycznej, toluen pochodzi zarówno ze skondensowanych struktur aromatycznych jak i z pseudostabilnej materii organicznej. Stosunek furfural/pyrol użyto w celu ekspresji stopnia mineralizacji materii organicznej. Furfural jest produktem nietrwałej substancji organicznej (sacharydy), a pyrol pochodzi ze stabilnej materii organicznej (nawilżonych składników zawierających azot). W porównaniu z niewapnowanymi osadami, osady wapnowane mają wyższy wskaźnik rozkładu materii organicznej, jak i późniejszej mineralizacji. Wapnowane osady gromadzą więcej związków pochodzących z ligniny co jest spowodowane bardziej intensywnym rozkładem polisacharydów. Z punktu widzenia wykorzystania w rolnictwie, szlam wapnowany jest najbardziej odpowiednim osadem wytwarzanym przez oczyszczalnie ścieków.
Źródło:
Inżynieria Mineralna; 2014, R. 15, nr 2, 2; 61-66
1640-4920
Pojawia się w:
Inżynieria Mineralna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water and sewage sludge co-digestion : characteristic of the process and its possible applications
Współfermentacja osadów ściekowych i z uzdatniania wody : charakterystyka procesu i możliwości zastosowania
Autorzy:
Górka, Justyna Łucja
Cimochowicz-Rybicka, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/204961.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
water treatment sludge
sewage sludge
co-fermentation
biogas
disintegration
dewatering
uzdatnianie wody
osad ściekowy
ko-fermentacja
biogaz
rozpad
odwadnianie
Opis:
The article describes problems related to intensification of energy production at a sewage treatment plant. The authors analyze anaerobic co-digestion of sludge from a water treatment plant and sewage treatment plant. The authors proposed a methodology of the research and analyzed the preliminary results, which showed that co-digestion of sewage and water sludge enhanced biogas production. The authors hope that the results of the study will provide a basis for development of methodology for sludge control and disposal.
Badania zaprezentowane w niniejszej publikacji, prowadziły do określenia możliwości wykorzystania osadów z uzdatniania wody jako substrat w procesie fermentacji metanowej osadów ściekowych. Autorzy zaproponowali metodologię badań i przeanalizowali wstępne wyniki, które wykazały, że dodanie osadów z uzdatniania wody do osadów ściekowych spowodowało zwiększoną produkcję biogazu. Zaproponowana technologia stanowi zintegrowany system gospodarki komunalnej, oparty na współpracy dwóch przedsiębiorstw: oczyszczalni ścieków i stacji uzdatniania, działających w systemie gospodarki cyrkulacyjnej. Rezultatem takiego rozwiązania są korzyści w zakresie odzysku biogazu, możliwego do wykorzystania w procesie kogeneracji.
Źródło:
Archives of Environmental Protection; 2019, 45, 1; 84-91
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary study of hot mix asphalt containing water treatment and sewage sludge
Autorzy:
Bastidas-Martínez, J. G.
Camapum de Carvalho, J.
Lucena, L. C.
Farias, M. M.
Rondón-Quintana, H. A.
Powiązania:
https://bibliotekanauki.pl/articles/230585.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
osad
uzdatnianie wody
osad ściekowy
wypełniacz mineralny
mieszanka asfaltowa gorąca
water treatment
sludge
sewage sludge
mineral filler
hot mix asphalt
Opis:
Throughout the world, considerable quantities of water treatment sludge (WTS) and sewage sludge (SS) are produced as waste. This study assessed in the laboratory, the possibility to use both waste products when they are incorporated as filler at 1% with relation to the total mass of a hot mix asphalt - HMA. To this end, both waste products were initially reduced to ash through a calcination process. Resistance tests under monotonic load (Marshall and indirect tension tests), and cyclic load (resilient modulus test) were applied on mixes that contained WTS and SS. Besides, moisture damage (modified Lotmman test), and abrasion (Cantabro) resistance were assessed. An analysis of variance (ANOVA) test was performed in order to verify if the results are statically equal or not to those of the control HMA. As a general conclusion, it is reported that both materials show a resistance increase under monotonic load and higher stiffness under cyclic load (cohesion) when they are incorporated into the mix as filler despite the fact that the asphalt content used was less than the control mix. However, some problems are observed associated with moisture damage resistance, and friction wear (adherence).
Źródło:
Archives of Civil Engineering; 2020, 66, 1; 225-240
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current stage of knowledge relating to the use ferruginous sludge from water treatment plants – a preliminary review of the literature
Autorzy:
Wołowiec, Magdalena
Bajda, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/127615.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mineralogiczne
Tematy:
water treatment residuals
reuse
water treatment
plant sludge management
Opis:
In water treatment plants, a large amount of wastewater and sludge is generated during the processing of drinking water. The composition of the sludge is determined by the type and raw water chemistry, as well as the methods and materials used for purification. The major components of the sludge are iron and manganese oxyhydroxides. In the past, the sludge was landfilled, but for environmental reasons it became necessary to find uses for the sludge. The aim of this study was to identify examples of using this sludge. Nowadays, the sludge is applied in the treatment of municipal wastewater, agriculture, and the production of cement and bricks, among others. Attention was also paid to the possibility of using the water processing sludge in different sorption applications.
Źródło:
Mineralogia; 2017, 48, 1/4; 39-45
1899-8291
1899-8526
Pojawia się w:
Mineralogia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post-coagulation sludge management for water and wastewater treatment with focus on limiting its impact on the environment
Zagospodarowanie osadów po procesie koagulacji wody, celem ograniczenia ich wpływu na środowisko
Autorzy:
Łukasiewicz, Ewelina
Powiązania:
https://bibliotekanauki.pl/articles/434998.pdf
Data publikacji:
2016-12-15
Wydawca:
Uniwersytet Opolski
Tematy:
post-coagulation sludge
sludge management
water treatment
osad pokoagulacyjny
gospodarka osadowa
oczyszczanie wody
Opis:
Water treatment process produces great amount of sludge. According to growing interest in sustainable development and environment protection, sludge management problem should be taken into consideration. Accordingly, its recovery, recycling and reuse are optimal solutions for Water Treatment Sludge(WTS) management. The conventional Water Treatment Plants (WTP) produce even up to 100 000 ton/year of sludge. The coagulation process produces a huge amount of sludge. This contamination may be recovered and reused. Some amount of coagulants may be recovered and reused during the wastewater treatment process. The Water Treatment Sludge with e.g. iron or alum content, may be also used as a coagulant at a wastewater treatment plant. In the course of this paper, few methods for post-coagulation sludge management are presented.
Proces oczyszczania wody skutkuje powstaniem dużej ilości osadów. Polityka zrównoważonego rozwoju, wymaga bezpiecznych dla środowiska działań proekologicznych, związanych z gospodarką wodno-ściekową. Zgodnie z tym stosuje się metody odzysku, recyklingu oraz ponownego użycia w stosunku do osadów powstających podczas uzdatniania wody.Proces koagulacji wód powierzchniowych i podziemnych powoduje powstanie dużej ilości osadów. Konwencjonalna stacja uzdatniania wody może produkować nawet do 100000 ton osadu rocznie. W niniejszej pracy przedstawiono metody stosowane w gospodarce osadowej, takie jak między innymi odzysk koagulantów z osadów, użycie osadu jako koagulantu na stacjach uzdatniania oraz oczyszczalniach ścieków, zastosowanie osadów jako kompozytu w budownictwie, stabilizację tlenową osadu celem zmniejszenia jego ilości, poprzez redukcję materiału organicznego.
Źródło:
Economic and Environmental Studies; 2016, 16, 4(40); 831-841
1642-2597
2081-8319
Pojawia się w:
Economic and Environmental Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermodynamic Analysis and Mathematic Modeling of Waste Sludge from Drinking Water Treatment Plants
Autorzy:
Azeddine, Fantasse
El Khadir, Lakhal
Ali, Idlimam
Powiązania:
https://bibliotekanauki.pl/articles/2026746.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
drinking water sludge
sludge valorization
wastewater management
thermodynamic analysis
isosteric heat
Opis:
Water treatment annually produces a huge amount of Drinking Water Treatment Sludge (DWTS) wastes. The latter causes environmental problems in Morocco in terms of energy and pollution. Therefore, cost-effective and eco-friendly solutions for managing them should be proposed in order to reduce the frequency of storage along with transportation costs. In this paper, a thermodynamic analysis of DWTS wastes was conducted based on the isosteric heat and compensation theory. Different results concerning the mineralogical identification of sludges were established. Findings revealed that the by-product of water purification was mainly composed of aluminum, silica and iron hydroxides, with pH varying between 6.23 and 6.85. The suspended matter was between 18.3 and 19.6 m/l. The volatile matter of the three sludge samples was between 18 and 21%. The measured dry matter content was between 13.41 and 15.23%. The experimental tests were performed under temperatures from 45 and 60 °C, the experimental data of the sorption curves were fitted by using several models of correlation. Furthermore, the analysis showed that the Peleg’s model perfectly described the isotherm curves in the activities ranging from 0 to 90%. The net isosteric heats of sorption of the three hydroxide sludge from the Moroccan treatment station: $S_k$, $S_m$ and $S_s$, were determined for desorption and adsorption. Moreover, it was revealed that the equilibrium water content rising lead contributed to the reduction of the net isosteric heat and the entropy of sorption. Finally, the enthalpy-entropy compensation showed that the sorption mechanism involved was enthalpy driven.
Źródło:
Journal of Ecological Engineering; 2022, 23, 2; 140-149
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of SS-VF Bed for the Treatment of High Concentrated Reject Water from Autothermal Termophilic Aerobic Sewage Sludge Digestion
Autorzy:
Dąbrowski, W.
Malinowski, P.
Karolinczak, B.
Powiązania:
https://bibliotekanauki.pl/articles/123643.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
autothermal thermophilic aerobic digestion
ATAD
reject water
vertical flow constructed wetland
SS VF
Opis:
The autothermal termophilic aerobic digestion (ATAD) technology is used in the municipal and industrial wastewater treatment plants (WWTPs) with personal equivalent up to 30.000. The process provides a high level of sewage sludge stabilization and its hygienization. The main operation problems are caused by the high concentration of nitrogen and phosphorus in the reject water from sewage sludge treatment and air purification (odor removal). Reject water usually is returned to the main sewage treatment, which has a negative impact, especially on the sewage treatment systems based on the sequence batch reactors (SBR). Applying high-performance and expensive separate reject water treatment methods such as SHARON, Anammox or CANON in small facilities is not justified economically. The article presents the research results concerning the effectiveness of applying subsurface vertical flow constructed wetlands (SS VF) for reject water treatment from the ATAD process. An innovative type of bed filling was used, which was produced from waste (ash from a heat and power plant). The efficiency of reject water treatment during the research period was on average at 45.6% for ammonia nitrogen, 32.3% for total phosphorus and 85.1% for BOD5. Applying SS VF beds for separate reject water treatment might ensure a stable and effective functioning of municipal WWTPs by decreasing the load of biological part of a WWTP.
Źródło:
Journal of Ecological Engineering; 2018, 19, 4; 103-110
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dewaterability of Digested Sludge Conditioned with Sludge from a Water Treatment Plant
Podatność na odwadnianie przefermentowanych osadów ściekowych kondycjonowanych osadami z stacji uzdatniania wody
Autorzy:
Kowalczyk, Mariusz
Kamizela, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1811949.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
municipal sludge
water processing sludge
conditioning
dewatering
komunalne osady ściekowe
osady pokoagulacyjne
kondycjonowanie
odwadnianie
Opis:
Sewage sludge treatment, including dewatering, represents a technological challenge similar to wastewater treatment. It is necessary for the effective sludge dewatering to use conditioning agents, and currently only polyelectrolytes. However, any factor or substance, including waste, which reduces the bonds between water and solid particles can be considered a conditioning agent. The study verified the possibility of conditioning the digested sludge with sludges from the water treatment plant, mainly produced by coagulation of chlorine iron III and denitrification, was verified. The main process variable was the volumetric fraction of water processing sludges in a mixture with municipal digested sludge amounting to 1:9, 3:7, 5:5. It was found that the sludge from water treatment plants cannot be used as aconditioner of municipal sludge. Deterioration of filtration and dewatering capacity of the tested mixtures and the quality of the separated sludge liquor was observed. The study confirmed the possibility of the use of post-coagulation sludge in sorption of metals and phosphorus.
Przeróbka osadów ściekowych, w tym ich odwadnianie, stanowi równorzędne wyzwanie technologiczne co oczyszczanie ścieków. Koniecznym dla efektywnego odwadniania osadów jest zastosowanie środków kondycjonujących, a obecnie wyłącznie, polielektrolitów. Niemniej jednak każdy czynnik czy substancja, w tym odpad, który umożliwi zmniejszenie powiązania między cząsteczkami wody i fazy stałej może zostać uznany za środek kondycjonujący. W przeprowadzonych badaniach zweryfikowano możliwość kondycjonowania osadów przefermentowanych osadami z stacji uzdatniania wody powstałymi głownie w procesie koagulacji zanieczyszczeń chlorkiem żelaza III oraz denitryfikacji. Główną zmienna procesową był udział objętościowy osadów z uzdatniania wody w mieszaninie z osadami przefermentowanymi wynoszący 1:9, 3:7, 5:5. Stwierdzono, że badane żelazowe osady pokoagulacyjne nie mogą być stosowane jako kondycjoner komunalnych osadów przefermentowanych. Odnotowano pogorszenie filtrowalności i odwadnialności badanych mieszanin oraz jakości oddzielonych cieczy osadowych. Badania potwierdziły możliwość zastosowania osadów pokoagulacyjnych celem sorpcji metali i fosforu.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 1; 217-233
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post-coagulation sludge as an adsorbent of dyes from aqueous solutions
Osad pokoagulacyjny jako adsorbent barwników z roztworów wodnych
Autorzy:
Pieczykolan, B.
Płonka, I.
Powiązania:
https://bibliotekanauki.pl/articles/127092.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
water treatment
coagulation
post-coagulation sludge
dyes
waste sorbent
sorption process
sorption isotherm
uzdatnianie wody
koagulacja
osad pokoagulacyjny
barwnik
proces sorpcji
sorbenty odpadowe
izoterma sorpcji
Opis:
Water taken from the environment, before it is directed to recipients as drinking water, must be purified via different processes. From the water, inter alia, suspensions, organic compounds, colloidal particles as well as bacteria and viruses must be removed. The main source of usable water supply is surface water. The most frequently used methods of surface water treatment are coagulation and filtration processes. During these processes post-coagulation sludge is generated, which is the main waste produced in water treatment plants. This sludge is characterized by an amorphous structure with a strongly developed specific surface, similar to sewage sludge. In addition, it has a high content of organic compounds. In recent years, attempts have been made to transform sewage sludge from municipal wastewater treatment plants into waste sorbents. Taking into account some similarity between sewage sludge and post-coagulation sludge, an attempt was made to apply post-coagulation sludge as sorbent of dyes from aqueous solutions. Dried and crushed post-coagulation sludge was used in the studies. The most favourable pH of process and contact time as well as sorption isotherm were established. Moreover, based on the different isotherm two-parameter models, the sorption capacity, type of sorption and energy of sorption were calculated.
Woda pitna, zanim zostanie skierowana do odbiorców, musi zostać poddana procesom oczyszczania. Z wody muszą zostać usunięte między innymi zawiesiny, substancja organiczna, cząstki koloidalne oraz bakterie i wirusy. Głównym źródłem zaopatrywania w wodę użytkową są wody powierzchniowe. Najczęściej stosowanymi metodami uzdatniania wody powierzchniowej są metody koagulacji i filtracji. W trakcie tych procesów powstają osady pokoagulacyjne, które są głównymi odpadami powstającymi w zakładach uzdatniania wody. Osady te charakteryzują się strukturą amorficzną o mocno rozbudowanej powierzchni właściwej, podobnie jak osady ściekowe. Ponadto posiadają dużą zawartość związków organicznych. W ostatnich latach podjęto próby przeróbki osadów ściekowych pochodzących z komunalnych oczyszczalni ścieków w celu uzyskania odpadowych sorbentów. Uwzględniając pewne podobieństwo pomiędzy osadami ściekowymi, jak również pokoagulacyjnymi podjęto próbę wykorzystania osadów pokoagulacyjnych jako sorbentów barwników z roztworów wodnych. W trakcie badań wykorzystano wysuszone i rozdrobnione osady pokoagulacyjne. Wyznaczono najkorzystniejsze parametry procesu sorpcji statycznej (pH i czas kontaktu), jak również izotermę adsorpcji. Ponadto wykorzystując różne modele dwuparametryczne, wyznaczono maksymalną pojemność sorpcyjną, typ adsorpcji oraz energię adsorpcji.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 315-323
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solidification as a process of treatment of post-coagulation sludge from the water treatment plant
Zestalanie jako proces przeróbki osadów pokoagulacyjnych pochodzących ze stacji uzdatniania wody
Autorzy:
Płonka, I.
Pieczykolan, B.
Kuszaj, D.
Rzeźniczek, G.
Powiązania:
https://bibliotekanauki.pl/articles/126530.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
post-coagulation sludge
solidification
disposed
osad pokoagulacyjny
zestalanie
unieszkodliwianie
Opis:
Post-coagulation sludge is generated in Water Treatment Plants (WTPs). This sludge is a mixture of pollutants removed from water and coagulants, which was added to the water. It has a hydrophilic and colloidal character. Moreover, it is characterized by high hydration, above 99 %. WTPs are obliged to implement solutions that allow optimal management of sludge. Therefore it is important to search processes whereby this sludge could be reused or eventually disposed of. The studies of solidification of post-coagulation sludge were carried out. The solidification process consists in the appropriate and rapid mixing the sludge with the material used for solidification in order to ensure the adequate homogenization conditions. The reagent used in solidification absorbs water contained in the sludge as a result of rapid homogenization with the sludge due to hydration, in a strongly exothermic process. The excess water evaporates form the sludge. This reduces the mass and volume of the sludge and leads to the formation of granules. During the tests, quicklime and cement Gorkal 40, Gorkal 50 and Gorkal 70 were used as a solidifying material, in doses of 0.7; 1.4; 2.1; 2.8; 3.5 g/kg TS. During the maturing process of the lime-sludge and cement-sludge mixtures, changes in the total solids concentrations were checked. The obtained test results show that increasing the solidification material dose and extending the maturation time results in a significant increase in the total solids concentration of the mixtures. Changing the structure and consistency of the sludge from plastic to solid gives the possibility to use sludge as a building material, for the reclamation of dumps, hardening roadsides or creating slopes and embankments.
W stacjach uzdatniania wody (SUW) powierzchniowej powstają osady pokoagulacyjne. Stanowią one mieszaninę usuniętych z wody zanieczyszczeń oraz dodanych do niej koagulantów, wykazując hydrofilowo-koloidalny charakter. Ponadto charakteryzują się wysokim uwodnieniem powyżej 99 %. SUW zobligowane są do wprowadzania rozwiązań umożliwiających optymalne gospodarowanie osadami. W związku z tym istotne jest poszukiwanie procesów, w wyniku których osady te mogłyby być ponownie wykorzystane lub ostatecznie unieszkodliwione. Przeprowadzono badania zestalania osadów pokoagulacyjnych. Proces zestalania polega na odpowiednim oraz szybkim mieszaniu osadu z użytym materiałem zestalającym, aby zapewnić odpowiednie warunki homogenizacji. Zastosowany reagent w wyniku szybkiej homogenizacji z osadem na skutek hydratacji, w procesie silnie egzotermicznym, pochłania wodę zawartą w osadach, której nadmiar odparowuje. Powoduje to zmniejszenie masy i objętości osadów i prowadzi do powstania granulatu. Podczas badań jako materiału zestalającego użyto wapna palonego oraz cementów Górkal 40, Górkal 50 i Górkal 70 w dawkach 0,7; 1,4; 2,1; 2,8; 3,5 g/kg s.m. W trakcie procesu dojrzewania mieszaniny wapienno-osadowej oraz cementowo-osadowej sprawdzano zmiany stężenia suchej masy. Uzyskane wyniki badań wykazały, że zwiększenie dawki materiału zestalającego oraz wydłużenie czasu dojrzewania powoduje znaczny wzrost stężenia suchej masy mieszanin. Zmiana struktury i konsystencji osadów od plastycznej do stałej daje możliwość wykorzystania osadów jako materiału budowlanego, do rekultywacji wysypisk, utwardzania poboczy dróg czy tworzenia skarp i wałów.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 325-333
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of Alum Sludge from Surabaya Water Treatment Plant, Indonesia
Autorzy:
Barakwan, Rizkiy Amaliyah
Trihadiningrum, Yulinah
Bagastyo, Arseto Yekti
Powiązania:
https://bibliotekanauki.pl/articles/124534.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
aluminum sludge
characteristics
comparison
water treatment
Opis:
A conventional water treatment plant (WTP) typically involves coagulation-flocculation processes to remove suspended particles and colloids in raw water. The process generates a large volume of alum sludge with high aluminum content, which is discharged into a river with improper treatment. The sludge may cause a potential risk to human health, and disrupt the life of river biota. The aims of this study were to determine the physical and chemical characteristics of alum sludge from Surabaya WTP, and to compare them with those of alum sludge from other plants in Indonesia and developing countries. The alum sludge sample was obtained from the Surabaya WTP in Indonesia. The results showed that the alum sludge had a pH value of 7.47, volatile solids of 12,696 mg/L, total suspended solids of 12,511 mg/L, chemical oxygen demand (COD) 9666.7 mg/L, biochemical oxygen demand (BOD) 1082.5 mg/L, and sludge volume index 114.18 mL/g. The sludge had high aluminum and iron concentrations. The aluminum content of the sludge was 1194 mg/L, iron 515 mg/L, chromium 0.217 mg/L, and copper 0.559 mg/L. Having a BOD/COD ratio of 0.1, the alum sludge contained high level of nonbiodegradable organic matter.
Źródło:
Journal of Ecological Engineering; 2019, 20, 5; 7-13
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic treatment and its applicability for the selective treatment of borax clayey waste sludge
Autorzy:
Gürsoy, Yaşar Hakan
Kurama, Haldun
Powiązania:
https://bibliotekanauki.pl/articles/1447005.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ultrasonic treatment
boron waste water
separation
sludge treatment
Opis:
Sludge treatment is one of the most difficult challenges for many industrial plants. In recent years, the use of ultrasound power has received considerable attention as one of the increasing tool for managing of this problem. Power ultrasound enhances chemical and physical changes in a liquid medium through the generation and subsequent destruction of cavitations bubbles. Therefore, the increased friction and stress in solution resultant with cleaning of the solid surfaces and dispersion of bonded/aggregated solid particles. In this study, the basic fundamentals of ultrasonic treatment and process variables were briefly overviewed. The study was also extended with preliminary analyses performed to determine its ability on the extraction of major and trace elements from Kırka Borax Concentrator tailings mainly boron as boric acid and Li as Li reach pregnant solution (PLS). Prior and after the sonification tests, physical, chemical and morphological analyses were carried out to determine the treatment performance. It was found that sonication leads the liberation of boron minerals from sludge and with the help of temperature they are dissolved and re-crystallized on clay substrate during cooling stage. The extraction test performed with these crystals revealed that Li-rich solution (that can be further use as source of lithium carbonate or lithium hydroxide production), and boric acid could be produced with easy and low cost beneficiation method.
Źródło:
Physicochemical Problems of Mineral Processing; 2021, 57, 5; 80-90
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wastewater treatment in an integrated laboratory system
Autorzy:
Lavrova, S.
Koumanova, B.
Powiązania:
https://bibliotekanauki.pl/articles/9991.pdf
Data publikacji:
2017
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
waste water treatment
ground water
surface water
water pollution
laboratory technique
landfill leachate
activated sludge reactor
biofilter
Opis:
Integrated laboratory system consisted of three stages - activated sludge reactor, biofilter and subsurface vertical flow wetland was used to treat two types of wastewaters differed in their generation and pollution. Wastewaters from a pig farm as well as from a landfill site for domestic wastes were used in the experiments. The BOD/COD ratio of the wastewaters from a pig farm and from the landfill leachate was 0.5 and 0.07, respectively. In the first stage of the integrated system was achieved COD removal (48 % for the piggery wastewater for 3 days and 62.3 % for the landfill leachate after 4 days). BOD removal (55.6 %) for the piggery wastewater was achieved in 3 days and 24.9 % - for the landfill leachate after 4 days. The decreasing of organics at aerobic conditions was accompanied with the ammonium ions decreasing - 1.5 times for the piggery wastewater and 4 times for the leachate. In the second stage - biofilter without aeration, an additional organic loading decreasing was achieved. The COD decreased from 820.9 mg/dm3 to 274.3 mg/dm3 for piggery wastewater and for the leachate - from 869.5 mg/dm3 to 423.6 mg/dm3. The BOD values decreased from 384.1 mg/dm3 to 106.8 mg/dm3 for the piggery wastewater and for leachate - from 117.8 mg/dm3 to 57.4 mg/dm3. The ammonium ions were eliminated from both types of wastewaters. In the third stage (subsurface vertical flow wetland) the emission standards for discharge into the sewage collection systems or into the water bodies are met.
Źródło:
Environment, Earth and Ecology; 2017, 1, 1
2543-9774
2451-4225
Pojawia się w:
Environment, Earth and Ecology
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies