Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flow volume" wg kryterium: Wszystkie pola


Tytuł:
The saturation flow volume as a function of the intersection passing speed
Gęstość strumienia nasycenia jako funkcja prędkości przejazdu skrzyżowania
Интенсивность потока насыщения как функция скорости проезда перекрестка
Autorzy:
Fornalchyk, Y.
Mohyla, I.
Hilevych, V.
Powiązania:
https://bibliotekanauki.pl/articles/375460.pdf
Data publikacji:
2013
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
signalized intersection
saturation flow
intersection passing speed
skrzyżowania z sygnalizacją świetlną
strumień nasycenia
prędkość przejazdu skrzyżowania
Opis:
Different methods of calculating the saturation flow volume were examined. It was found that none of them considers the speed of vehicles passing through the intersection (intersection passing speed). For this reason we examined the effect including intersection passing speed has on the accuracy of assessing traffic conditions at intersections by including this parameter in tests run on VISSIM software. Our tests showed that accurately assessing the saturation flow volume depends on including intersection passing speed and the size of the intersection.
Рассмотрены методы расчета интенсивности потока насыщения и установлено, что они не учитывают скорости проезда перекрестка. Исходя из этого, предложено использовать скорость проезда перекрестка как обобщенный параметр условий движения на перекрестке, для чего в среде VISSIM проведены соответствующие исследования. Установлено, что интенсивность потока насыщения зависит от скорости проезда перекрестка и его длины.
Źródło:
Transport Problems; 2013, 8, 3; 43-51
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculating study of the turbine at last stage flow field in the small volume flow condition
Autorzy:
Jiang, T.
Jin, J.
Wang, Z.
Cao, L.
Li, B.
Powiązania:
https://bibliotekanauki.pl/articles/258680.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
turbine
small volume flow
flow model
backflow
Opis:
Based on basic equation and boundary layer theory of pneumodynamics, the thesis conducts numerical modeling and theoretical analysis on the last stage of turbine characteristics at a small volume flow by using FLUENT, gives an emphasized analysis on the position of first occurrence of backflow and its expansion direction and comes up with flow structure of the turbine flow field at last stage in the small volume flow condition. In connection with specific experiments, it puts forward the flow model of backflow occurring in the last stage field and the solution to the model. The flow field at last stage for a 100MW turbine in the small volume flow condition that is calculated by using the model is basically in conformity to the actual result.
Źródło:
Polish Maritime Research; 2017, S 3; 23-27
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The importance of blood flow volume in the brainsupplying arteries for the clinical management – the impact of collateral circulation
Znaczenie objętości przepływu w tętnicach dogłowowych dla postępowania klinicznego – wpływ rozwoju krążenia obocznego
Autorzy:
Elwertowski, Michał
Leszczyński, Jerzy
Kaszczewski, Piotr
Lamparski, Krzysztof
Sin Yee Ho, Stella
Gałązka, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/1033093.pdf
Data publikacji:
2018
Wydawca:
Medical Communications
Tematy:
cerebral flow volumetry
Opis:
Aim: An assessment of increased compensatory blood flow in the brain-supplying arteries in patients with significant carotid artery stenosis. Materials and methods: Doppler ultrasound was performed in 218 patients over 60 years of age to evaluate both the degree of brain-supplying artery stenosis as well as the blood flow volume balance in all vessels supplying the brain: the internal carotid artery, the external carotid artery and the vertebral artery. The control group included 94 patients with no stenosis in the extracranial segments and no neurological manifestations, in whom blood flow values were calculated (the internal carotid artery – 290 mL/min, the external carotid artery – 125 mL/min, the vertebral artery – 80 mL/min); the total mean blood flow in the brain-supplying arteries was 985 mL/min. A 33% increase in blood flow was considered compensatory. In addition to the control group, 30 patients with asymptomatic stenosis of less than 50% and 12 patients after endarterectomy with mean blood flow of 920 mL/min and 960 mL/min, as well as two groups of particular interest to us, i.e. 38 patients with no compensatory blood flow increase despite significant stenosis (>50%) with mean blood flow of 844 mL/ min and 44 patients with similar stenosis and with compensatory blood flow increase up to 1174 mL/min were included in the analysis. Results: Comparison of the two groups showed several significant differences: increased blood flow (118% vs. 86% of the norm) in patients with compensated stenosis, an increased number of asymptomatic patients (70% vs. 37%) and a threefold increase in the number of patients with occlusions (15 : 5) in the group of patients with increased blood supply to the brain. Conclusions: All potential blood-supplying vessels, including the external carotid artery, are involved in brain tissue perfusion in some of the patients with significant stenosis. Determining the degree of compensation may have an important impact on the indications for surgical treatment, which will make a valuable contribution to the current criteria (asymptomatic/ symptomatic patients).
Cel pracy: Ocena wpływu kompensacyjnego wzrostu przepływu w naczyniach dogłowowych u chorych z istotnymi zwężeniami tętnic szyjnych. Materiał i metoda: U 218 chorych powyżej 60. roku życia wykonano rozszerzone badanie ultrasonograficzne z opcją dopplera w celu oceny zarówno stopnia zwężenia naczyń dogłowowych, jak i bilansu objętości przepływu we wszystkich głównych naczyniach doprowadzających krew do mózgu: tętnicy szyjnej wewnętrznej, tętnicy szyjnej zewnętrznej i tętnicy kręgowej. Grupę kontrolną stanowiło 94 pacjentów bez zwężeń naczyń w odcinkach przedczaszkowych oraz bez objawów neurologicznych, u których obliczono normy przepływu w naczyniach (tętnica szyjna wewnętrzna – 290 ml/min, tętnica szyjna zewnętrzna – 125 ml/min, tętnica kręgowa – 80 ml/min); całkowity przepływ w naczyniach dogłowowych wynosił u nich średnio 985 ml/min. Za kompensacyjny wzrost uznano zwiększenie przepływu o 33%. Poza grupą kontrolną analizie poddano 30 pacjentów z bezobjawowymi zwężeniami poniżej 50% i 12 osób po endarterektomii ze średnimi przepływami 920 ml/min i 960 ml/min, a także dwie szczególnie interesujące nas grupy: 38 pacjentów bez kompensacyjnego wzrostu przepływu pomimo istotnych (>50%) zwężeń ze średnim przepływem 844 ml/min oraz 44 chorych z kompensacyjnym wzrostem przepływu do 1174 ml/min przy podobnych zwężeniach. Wyniki: Porównanie dwóch grup wykazało kilka istotnych różnic: większy przepływ (118% vs 86% normy) u chorych ze skompensowanymi zwężeniami, większą liczbę chorych bezobjawowych (70% vs 37%) oraz trzykrotnie więcej chorych z niedrożnościami (15 : 5) w grupie pacjentów ze zwiększonymi przepływami domózgowymi. Wnioski: Wszystkie naczynia mogące doprowadzić krew do mózgu, w tym tętnica szyjna zewnętrzna, u części chorych z istotnymi zwężeniami biorą udział w zapewnieniu perfuzji tkanki mózgowej. Określenie stopnia kompensacji może w istotny sposób wpłynąć na wskazania do leczenia zabiegowego, co stanowi cenne uzupełnienie dotychczasowych kryteriów (pacjenci bezobjawowi/objawowi).
Źródło:
Journal of Ultrasonography; 2018, 18, 73; 112-119
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of synthetic rainfall application with respect to the flow volume at upstream Brantas watershed, East Java Province of Indonesia
Ocena użycia sztucznego deszczu w relacji do natężenia przepływu w górnej części zlewni Brantas, Prowincja Wschodniej Jawy, Indonezja
Autorzy:
Limantara, L. M.
Harisuseno, D.
Hapsari, R. K.
Powiązania:
https://bibliotekanauki.pl/articles/292575.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
control area
double ratio
flow discharge
synthetic rainfall
target area
dwustosunek
obszar badań
obszar kontrolny
sztuczny deszcz
wielkość odpływu
Opis:
Indonesian Technical Implementation Unit (UPT) of Synthetic Rainfall has modified climate by generating synthetic rainfall from 9th May until 4th June 2013. This unit has cooperated with the Department of Technological Study and Application (BPPT) of Indonesia and Perum Jasa Tirta I and TNI AU Lanud Abdulrachman Saleh. This study intended to increase reservoirs water level in upstream Brantas watershed, one of them is Sutami reservoir. Successive grade evaluation of synthetic rainfall used the method of Double Ratio and Flow Discharge. The target area is upstream Brantas watershed that is represented by 12 rainfall stations and the control area is in the distance of ±30 km from the boundary of upstream Brantas watershed and is represented by 5 rainfall stations. Results show rainfall increasing by 152.05% according to the Double Ratio method and the increase of flow discharge from Sutami reservoir by 74.19% according to the Flow Discharge method.
Indonezyjski Dział Technicznych Wdrożeń (UPT) Sztucznego Deszczu dokonał modyfikacji klimatu przez wygenerowanie sztucznego deszczu od 9 maja do 4 czerwca 2013 r. Dział ten współpracował z Departamentem Technologicznych Badań i Zastosowań (BPPT) Indonezji oraz z Perum Jasa Tirta I i z TNI AU Lanud Abdulrachman Saleh. Celem badań było podniesienie poziomu wody w zbiornikach na terenie górnej części zlewni Brantas. Jednym z tych zbiorników jest Sutami. Stopniowej oceny sztucznego opadu dokonano, używając metody dwustosunku i metody wielkości odpływu. Obiektem badań była górna część zlewni Brantas reprezentowana przez 12 posterunków pomiaru opadu i obszar kontrolny leżący ok. 30 km od granicy zlewni reprezentowany przez 5 posterunków opadowych. Wyniki wskazują wzrost opadu o 152,05% według metody dwustosunku i wzrost odpływu ze zbiornika Sutami o 74,19% według metody wielkości odpływu.
Źródło:
Journal of Water and Land Development; 2017, 35; 129-136
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wear processes of hydraulic plunger and barrel assemblies connected with the time of their work
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/246273.pdf
Data publikacji:
2014
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
pump delivery
volume flow rate
hydraulic precision pair
avionic technology
Opis:
The article discusses the wear processes of hydraulic plunger assemblies connected with the time of their work and the impact exerted by these processes on the value of parameters of a hydraulic plunger pump. It describes working conditions and loading of a hydraulic plunger assembly. The paper presents also the results of empirical analyses of the wear process of the connection of the plunger base with the working surface of the swivel disk, which is related to time and conditions of its work. It discusses the impact of the loading value and sliding speed on the character and intensity of the wear of the connection between the plunger base and the working surface of a swivel disk. Furthermore, it presents a general characteristic and mechanism responsible for the wear of the hydraulic plunger assembly through oxidation. The article also analyses the impact of the hardness of materials used for producing the hydraulic plunger assembly on the intensity of its wear. Another issue is the dependence of the coefficient of friction in the hydraulic plunger assembly on the contact pressure at different sliding speeds. Finally, the paper discusses the impact of wearing of the cooperating plunger base and the working surface of the swivel disk on the initial parameters of the hydraulic pump at a given working pressure and its volumetric efficiency.
Źródło:
Journal of KONES; 2014, 21, 4; 515-524
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Dynamics of Liquid Movement Inside the Nozzle During the Bubble Departures for Low Air Volume Flow Rate
Autorzy:
Dzienis, P.
Mosdorf, R.
Wyszkowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/386993.pdf
Data publikacji:
2012
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
pęcherze gazowe
analiza nieliniowa
bubbles
nonlinear analysis
Opis:
The main aim of investigation was to analyze the influence of liquid movement inside the nozzle on the dynamics of bubble departure. Dynamics of such process decides about the periodic and aperiodic bubble departures. During the experiment it has been simultaneously recorded: changes of the depth of the nozzle penetration by liquid, air pressure and shape of bubble trajectory directly over the nozzle (in the length of 30 mm). The air volume flow rate was in the range 0.00632 - 0.0381 l/min. There has been shown that for all air volume flow rates the time periods with periodic and aperiodic bubble departures have been occurred. Duration of these intervals varies with the air volume flow rate. It has been found that the aperiodic bubble departures begin when the time of bubble growth increases. The changes of maximum values of liquid position inside the nozzle are associated with changes of the shape of bubble trajectories. There has been shown that straightens of the trajectory precedes the appearance of periodical or aperiodic time period of bubble departures. The aperiodic bubble departures are accompanied by a significant deviation of bubble trajectory from a straight line. The correlation dimension analysis shown that three independent variables are enough to describe the behaviour of liquid movement inside the nozzle. These independent variables may be: liquid velocity, liquid position in the nozzle and gas pressure in the nozzle.
Źródło:
Acta Mechanica et Automatica; 2012, 6, 3; 31-36
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of dynamic properties attributable to hydraulic lines onto operation of avionic
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/247057.pdf
Data publikacji:
2011
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
pump delivery
volume flow rate
hydrostatic (forcing) pressure
compressibility effect
viscous friction effect
Opis:
The present paper is dedicated to discuss how dynamic parameters of a hydraulic line intended to transfer hydraulic power from a source of hydraulic power (a hydraulic pump) to an actuating device (a hydraulic motor) can affect operation of an avionic hydraulic drive. Avionic hydraulic drives are operated with fast-varying waveforms of flow intensities and pressures. It is why analysis of most hydraulic drive systems must take account of compressibility of working fluid and elasticity of hydraulic lines. It leads to a wave model for propagation of energy variation down a hydraulic line (a pipe). The paper deals with flow of a compressible liquid via a hydraulic line with flexible walls. Theoretical deliberations were successfully verified by experimental research studies that were carried out on a dedicated test bench, therefore the presented amplitude vs. frequency characteristic curves of the hydraulic line could be obtained from both theoretical considerations and experimental research studied. The experimental research studies were carried out for hydraulic line terminated with a fixed flow restrictor alone and a flow restrictor combined with a hydraulic accumulator as well as for a hydraulic line supplied from a source of constant pressure and terminated with a valve with adjustable flow together with a hydraulic accumulator. The theoretical calculations for the amplitude vs. frequency characteristic curve are based on a model for a hydraulic line with its resistance depending on frequency.
Źródło:
Journal of KONES; 2011, 18, 4; 535-542
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of dynamic properties of hydraulic lines for fluid power transmission
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/247615.pdf
Data publikacji:
2010
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
fluid power transmission
delivery of a pump
volume flow rate
hydrostatic (forcing) pressure
compressibility effect
viscous friction effect
Opis:
This paper presents the results of a hydraulic line dynamic properties analysis taking into account inertia of the fluid flowing in rigid and flexible lines, the compressibility effect for this fluid and the viscous friction effect. The following are described and analyzed: solution of the wave equation in the form binding four variables: pressure and flow rate at the line input, and pressure and flow rate and the line output; two of the above-mentioned variables should be regarded as independent (input) and the other two as dependent (output), the accuracy comparison of distributed parameters model to lumped parameters model with regard to applicability range in hydraulic systems analysis, pressure value at given installation points as a response to rapid valve closing (transient response) or to valve opening (waterhammer effect). In these considerations the hydraulic line is regarded as a two-port with two inputs and two outputs with a definite transmittance matrix. Main considerations concern the variable resistance model. A general solution is given as a function of the Laplace operator. Introducing appropriate simplifications into the variable resistance model, the constant resistance model and lossless line model is obtained. Also, general solutions for three different lump parameter models are presented. For the lumped parameters lin presents three equivalent models possible, i.e. as: a symmetrical two-port, a two-port with shared resistance and a two-port with capacitance at the output.
Źródło:
Journal of KONES; 2010, 17, 3; 467-475
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The unified algorithm for detection of potential lesions in dynamic perfusion maps cerebral blood flow, cerebral blood volume and time to peek
Autorzy:
Hachaj, T.
Powiązania:
https://bibliotekanauki.pl/articles/333475.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
dynamiczna perfuzja tomografii komputerowej
mapa perfuzji
wykrywanie zmian
wykrywanie asymetrii
dynamic CT perfusion
perfusion maps
CBF
CBV
TTP
lesions detection
asymmetry detection
Opis:
This paper presents an unified algorithm that enables detection of lesions in cerebral blood flow (CBF), cerebral blood volume (CBV) and time to peek (TTP) perfusion maps. The algorithm has one adaptive parameter for each type of perfusion map, the rest of algorithm is common for all kinds of perfusion images. There are two steps of the algorithm: in the first step the algorithm detects symmetry axis of a perfusion map (between left and right hemisphere), in the second stage the level of asymmetry in cerebral blood flow, cerebral blood volume or time to peak is measured by detection of regions with different perfusion in both brain hemispheres. Test of the algorithm were performed on a set of 84 different CBF, CBV and TTP images showing or not cerebral blood flow and volume anomalies. The algorithm presented in this publication has achieved satisfactory results. On 85,7% maps asymmetry regions was properly detected.
Źródło:
Journal of Medical Informatics & Technologies; 2008, 12; 117-122
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the continuous traverse trajectory and dynamic error of the vane anemometer on the accuracy of average velocity measurements at the cross-section of the mine heading – model-based testing
Wpływ trajektorii trawersu ciągłego oraz błędu dynamicznego anemometru skrzydełkowego na dokładność pomiaru prędkości średniej w przekroju wyrobiska kopalnianego – badania modelowe
Autorzy:
Jamróz, P.
Powiązania:
https://bibliotekanauki.pl/articles/219564.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
strumień objętości powietrza
trawers ciągły
profil prędkości
anemometr skrzydełkowy
błąd dynamiczny
air volume flow
continuous traverse
velocity profile
vane anemometer
dynamic error
Opis:
This paper discusses the problem of measuring the average velocity at the cross-section of mine heading with the use of the continuous traverse method. Based on model testing, it has been shown that measurement signals, obtained along the traversing trajectory, belong to the group of non-stationary signals. The methodology of the traversing method measurements, with the aspect of capabilities of measuring instruments used for that purpose, has been analysed. Results of simulation tests concerning the dynamic response of a vane anemometer to the measurement signal for selected trajectories of the continuous traverse have been presented. For this purpose, a velocity profile presenting an expanded stream of undisturbed air flow in the excavation has been used. Attention has been paid to the problem of selecting an adequate trajectory of anemometer movement, as the value of the velocity measured at the cross-section depends on the trajectory.
W artykule poruszono problem pomiarów prędkości średniej w przekroju wyrobiska kopalnianego z wykorzystaniem metody trawersu ciągłego. Na podstawie badań modelowych wykazano, że sygnały pomiarowe, które uzyskuje się wzdłuż trajektorii trawersowania należą do grupy sygnałów niestacjonarnych. Przeanalizowano metodologię przeprowadzania pomiarów metodą trawersowania w aspekcie możliwości pomiarowych wykorzystywanych w tym celu urządzeń pomiarowych. Przedstawiono wyniki badań symulacyjnych dynamicznej odpowiedzi anemometru skrzydełkowego na sygnał pomiarowy dla wybranych trajektorii trawersu ciągłego. W tym celu wykorzystano profil prędkości przedstawiający rozwiniętą strugę niezakłóconego przepływu powietrza w chodniku. Zwrócono uwagę na problem doboru odpowiedniej trajektorii przemieszczania anemometru, od której zależy wartość mierzonej prędkości średniej w przekroju.
Źródło:
Archives of Mining Sciences; 2014, 59, 4; 1051-1060
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flow simulations in cross-flow fans using the finite element and finite volume methods
Autorzy:
Sowa, A.
Powiązania:
https://bibliotekanauki.pl/articles/1955710.pdf
Data publikacji:
2004
Wydawca:
Politechnika Gdańska
Tematy:
turbomachinery
cross-flow fan
finite element method
finite volume method
usteady flow analysis
Opis:
Both basic computational fluid dynamics methods: the finite element method (FEM) and the finite volume method (FVM) have been used to simulate flow fields in a cross-flow fan (CFF). A review of previous numerical simulations of flow in CFF's is presented. The theorethical foundations of the applied numerical algorithms and specifications of the computer programs are given. The procedure of computations is described in detail. Computational results are shown in the form of contour and vector velocity and contour pressure plots.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2004, 8, 1; 41-49
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unstructured finite-volume meshes for two-dimensional flow in variably saturated porous media
Autorzy:
Burzyński, K.
Szymkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/1934018.pdf
Data publikacji:
2011
Wydawca:
Politechnika Gdańska
Tematy:
finite volume method
Richards' equation
unsaturated flow
unstructured mesh
Opis:
This paper presents a numerical algorithm for solving the equation describing variably saturated flow in porous media. The algorithm is based on a control volume finite element approach and can be applied to two-dimensional unstructured meshes consisting of triangular elements. Two methods of defining the dual control volume grid are discussed. We also demonstrate that the method of calculating the average permeability at the control volume face significantly influences numerical results.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2011, 15, 3-4; 339-352
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of methods for calculating the gas volume fraction in the vertical descending flow of two-phase gas-liquid mixtures
Autorzy:
Czernek, K.
Okoń, P.
Powiązania:
https://bibliotekanauki.pl/articles/95229.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
two phase flow gas-liquid
volume share of gas
hydrodynamic flow
przepływ dwufazowy gaz-ciecz
udział objętościowy gazu
przepływ hydrodynamiczny
Opis:
The paper presents the results of research on the vertical falling flow and their analysis. Methods for calculating the gas volume fraction, which are characterized by high accuracy, and are often proposed in the literature. Their accuracy was presented, as well as the methods with the highest computational usefulness when designing devices in which two-phase gas - liquid flow is used.
Źródło:
Journal of Mechanical and Energy Engineering; 2018, 2, 4; 293-300
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simplified Volume of Fluid Method (SVOF) for two-phase flows
Autorzy:
Marek, M.
Aniszewski, W.
Bogusławski, A.
Powiązania:
https://bibliotekanauki.pl/articles/1943237.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska
Tematy:
two-phase flow modeling
volume of fluid
eulerian simulation
Opis:
The PLIC approach has been usually used in recent implementations of the VOF method i.e. the interphasal surface is approximated by a plane with an arbitrary orientation with respect to the computational cell. Although this method is accurate, it is rather difficult to implement, as a large number of orientations need to be taken into account and the calculation of volume fraction fluxes is not straightforward. A simpler approach to VOF – SLIC – requires much less effort from the programmer but the interface approximation by a plane parallel to the cell surfaces is too crude and the results are not satisfactory. The method presented in the article may be considered as an intermediate approach between PLIC and SLIC – fluxes are computed directly only for the interface’s special orientations and linear interpolation is used for calculation of the fluxes for the remaining cases. Some classical tests of the proposed method are performed and an example of a broken dam problem simulation is presented.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2008, 12, 3-4; 255-265
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implicit versus explicit finite volume schemes for extreme, free surface water flow modelling
Autorzy:
Szydłowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/241313.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
general scheme implicit in time
finite volume method
extreme flows
Opis:
One explicit and three implicit finite volume method schemes of the Roe type are presented in the paper. The properties and applicability of these methods for modelling unsteady, rapidly varied, open channel flow are investigated. The schemes are used for numerical simulation of one-dimensional extreme flow described by de Saint-Venant equations. The computational results are compared with each other and an analytical (exact) solution to an idealized dam-break problem. The classical versions of general scheme implicit in time - fully implicit and trapezoidal scheme - are not restricted by a stability condition, like an explicit one, however they add some numerical diffusion and dispersion errors to the solution. The modification of parameter , originally proposed for a box scheme of finite difference method, has improved computational properties of the general one-step implicit scheme. This version of finite volume scheme of the Roe type implicit in time can be recommended for modelling and simulation of transient flows in storm sewers and open channel networks.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2004, 51, 3; 287-303
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies