Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Nitsch, K." wg kryterium: Autor


Wyświetlanie 1-15 z 15
Tytuł:
Simple Wide Frequency Range Impedance Meter Based on AD5933 Integrated Circuit
Autorzy:
Chabowski, K.
Piasecki, T.
Dzierka, A.
Nitsch, K.
Powiązania:
https://bibliotekanauki.pl/articles/221804.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impedance
converter
AD5933
system-on-a-chip
measurement
Opis:
As it contains elements of complete digital impedance meter, the AD5933 integrated circuit is an interesting solution for impedance measurements. However, its use for measurements in a wide range of impedances and frequencies requires an additional digital and analogue circuitry. This paper presents the design and performance of a simple impedance meter based on the AD5933 IC. Apart from the AD5933 IC it consists of a clock generator with a programmable prescaler, a novel DC offset canceller for the excitation signal based on peak detectors and a current to voltage converter with switchable conversion ratios. The authors proposed a simple method for choosing the measurement frequency to minimalize errors resulting from the spectral leakage and distortion caused by a lack of an anti-aliasing filter in the DDS generator. Additionally, a novel method for the AD5933 IC calibration was proposed. It consists in a mathematical compensation of the systematic error occurring in the argument of the value returned from the AD5933 IC as a result. The performance of the whole system is demonstrated in an exemplary measurement.
Źródło:
Metrology and Measurement Systems; 2015, 22, 1; 13-24
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory evaluation of rubber linings used in flue gas desulphurization plants by the gravimetric method and impedance spectroscopy
Laboratoryjna ocena wykładzin gumowych używanych w instalacjach odsiarczania spalin, metodą grawimetryczną i spektroskopii impedancyjnej
Autorzy:
Drela, I.
Masalski, J.
Nitsch, K.
Piasecki, T.
Szczygieł, B.
Powiązania:
https://bibliotekanauki.pl/articles/172882.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odsiarczanie spalin
metoda grawimetryczna
metoda spektroskopii impedancyjnej
wykładzina gumowa
materiał powłokowy
flue gases desulphurization
gravimetric method
impedance spectroscopy method
rubber linings
lining material
Opis:
Special cells made of austenitic steel were employed to carry out accelerated tests of lining materials in the autoclave at elevated temperature and at a pressure gradient along the sample’s thickness. The tests were carried out on three kinds of rubber linings: prevulcanized soft two-ply lining based on bromobutyl rubber, selfvulcanizing two-ply lining based on bromobutyl rubber and prevulcanized lining based on chlorobutyl rubber. Distilled water, 1 % aqueous solution of HCl and aqueous solution containing 50 g/dm3 of sulphuric acid and 26 g/dm3 of sodium bisulphate (IV) were used as the working medium in the tests. The temperature of the working medium in the autoclave was kept at 110±2°C and the sample exposure time amounted to 48 hours. The change in the mass of the samples after the proper time of exposure in the autoclave was determined by the gravimetric method. A measuring system made up of an Agilent 4294A high-frequency impedance analyzer and a low-frequency impedance analyzer with a Keithley 428 current/voltage transducer was used to perform measurements in a frequency range from 0.1 mHz to 10 MHz at activation with an voltage amplitude of 1 V[RMS]. The impedance measurement results show that despite the severe corrosive conditions in the autoclave and the gain in the mass of the samples, the tested coating materials did not undergo significant degradation during their exposure and keep good dielectric and protective properties.
Zastosowano specjalne komórki ze stali austenitycznej, umożliwiające przeprowadzenie przyspieszonych badań materiałów powłokowych w autoklawie w warunkach podwyższonej temperatury i gradientu ciśnienia na grubości próbki. Badania wykonano dla trzech rodzajów wykładzin gumowych: wstępnie wulkanizowanej miękkiej wykładziny dwuwarstwowej na bazie kauczuku bromobutylowego, dwuwarstwowej samowulkanizującej się wykładziny na bazie kauczuku bromobutylowego i wstępnie wulkanizowanej wykładziny na bazie kauczuku chlorobutylowego). W badaniach jako medium robocze stosowano wodę destylowaną, 1% roztwór wodny kwasu solnego oraz roztwór wodny zawierający 50 g/dm3 kwasu siarkowego i 26 g/dm3 wodorosiarczanu (IV) sodu. Temperaturę medium roboczego w autoklawie utrzymywano w zakresie 110±2°C, a czas ekspozycji próbek wynosił 48 godz. Metodą grawimetryczną oznaczano zmianę masy próbek po odpowiednim czasie ekspozycji próbek w autoklawie, a wykorzystując system pomiarowy zestawiony z wysokoczęstotliwościowego analizatora impedancji Agilent 4294A oraz niskoczęstotliwościowego analizatora impedancji z przetwornikiem prąd-napięcie Keithley 428 wykonywano pomiary w zakresie częstotliwości od 0,1 mHz do 10 MHz przy pobudzeniu o amplitudzie napięcia przemiennego 1 V[RMS]. Otrzymane wyniki badań impedancyjnych pozwalają stwierdzić, że badane materiały powłokowe, pomimo ostrych warunków korozyjnych w autoklawie i zwiększenia masy próbek, nie uległy znaczącej destrukcji podczas ekspozycji i zachowały dobre właściwości dielektryczne i ochronne.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 27-36
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hyperfine Field in YIG with Charged Substitution
Autorzy:
Kohout, J.
Štĕpánková, H.
Englich, J.
Novák, P.
Kučera, M.
Nitsch, K.
Powiązania:
https://bibliotekanauki.pl/articles/2013158.pdf
Data publikacji:
2000-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
76.60.-k
75.50.Gg
Opis:
$\text{}^{57}$Fe NMR spectra were measured on thin films of yttrium iron garnet with divalent (Ca$\text{}^{2+}$) and tetravalent (Ge$\text{}^{4+}$) cation substitutions using the spin echo technique at 4.2 K. A series of Y$\text{}_{3-x}$Ca$\text{}_{x}$Fe$\text{}_{5-x}$Ge$\text{}_{x}$O$\text{}_{12}$ samples with 0 ≤ x ≤ 0.0 5 was prepared by an epitaxial growth from BaO/B$\text{}_{2}$O$\text{}_{3}$/BaF$\text{}_{2}$ flux on gadolinium gallium garnet substrate. Satellite lines corresponding to the iron ions having the Ge$\text{}^{4+}$ and Ca$\text{}^{2+}$ in their neighbourhood were identified. The sample with the germanium content of x(Ge) = 0.004 and (110) substrate orientation was used for a detailed study: NMR spectra of this sample were measured in an external magnetic field of 0.1 T applied along several directions in the plane of the film. The modification of the isotropic part and the anisotropy tensor of the hyperfine interaction caused by the Ge$\text{}^{4+}$ substituent were obtained from the experimental data. The results were compared with those previously reported for trivalent substitution (Ga$\text{}^{3+}$).
Źródło:
Acta Physica Polonica A; 2000, 97, 3; 519-522
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atmospheric Pressure Plasma Jet for Mass Spectrometry
Autorzy:
Babij, M.
Gotszalk, T.
Kowalski, Z.
Nitsch, K.
Silberring, J.
Smoluch, M.
Powiązania:
https://bibliotekanauki.pl/articles/1198872.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.50.Dg
82.80.Ms
Opis:
The atmospheric pressure plasma is much advantageous over low pressure plasmas in various aspects, e.g. vacuum-free operation, relative low cost, flexibility of a continuous process. Among various plasmas generated in atmospheric pressure discharges there are cold plasma jets that represent a technology of great application promise (industry, medicine, biology). To generate low-temperature plasmas at atmospheric pressure the dielectric barrier discharge can be used. It is suitable for the atomization of volatile species and can also be served as a ionization source for ambient mass and ion mobility spectrometry. As the discharge is generated in a restricted electrode structure, a plasma jet (plume) is usually formed outside the electrode region (that provides spatial separation of the plasma generation and surface processing regions). The paper presents a source based on a plasma jet established at the end of a capillary dielectric barrier discharge at atmospheric pressure and its application to mass spectrometry. The structure of the jet generator consists of piezoelectric transformer and two concentric and symmetric electrodes, between which the working gas flows at definite rate. Besides the source description early results of spectroscopic analysis are also given.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1260-1262
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antisite Defects in Epitaxial Films of Lutetium Doped Yttrium Iron Garnets Studied by Nuclear Magnetic Resonance
Autorzy:
Chlan, V.
Štěpánková, H.
Englich, J.
Řezníček, R.
Kouřil, K.
Kučera, M.
Nitsch, K.
Powiązania:
https://bibliotekanauki.pl/articles/1534129.pdf
Data publikacji:
2010-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Gg
76.60.-k
76.60.Lz
68.35.Dv
68.55.Ln
Opis:
Series of lutetium doped yttrium iron garnet films is studied by means of $\text{}^{57}Fe$ nuclear magnetic resonance. Satellite spectral lines are resolved and identified in the spectra and concentrations of lutetium in dodecahedral sites as well as yttrium/lutetium antisite defects in octahedral sites are estimated. Compared to yttrium, lutetium cations are found to have stronger disposition towards creating the antisite defects.
Źródło:
Acta Physica Polonica A; 2010, 118, 5; 846-847
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impedance Sensors Made in PCB and LTCC Technologies for Monitoring Growth and Degradation of Pseudomonal Biofilm
Autorzy:
Chabowski, K.
Junka, A. F.
Piasecki, T.
Nowak, D.
Nitsch, K.
Smutnicka, D.
Bartoszewicz, M.
Moczała, M.
Szymczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/221326.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Pseudomonas aeruginosa
biofilm
interdigitated sensor
impedance spectroscopy
Opis:
The suitability of low-cost impedance sensors for microbiological purposes and biofilm growth monitoring was evaluated. The sensors with interdigitated electrodes were fabricated in PCB and LTCC technologies. The electrodes were golden (LTCC) or gold-plated (PCB) to provide surface stability. The sensors were used for monitoring growth and degradation of the reference ATCC 15442 Pseudomonas aeruginosa strain biofilm in invitro setting. During the experiment, the impedance spectra of the sensors were measured and analysed using electrical equivalent circuit (EEC) modelling. Additionally, the process of adhesion and growth of bacteria on a sensor’s surface was assessed by means of the optical and SEM microscopy. EEC and SEM microscopic analysis revealed that the gold layer on copper electrodes was not tight, making the PCB sensors susceptible to corrosion while the LTCC sensors had good surface stability. It turned out that the LTCC sensors are suitable for monitoring pseudomonal biofilm and the PCB sensors are good detectors of ongoing stages of biofilm formation.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 369-380
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lifestyle intervention towards Mediterranean Diet, physical activity adherence and anthropometric parameters in normal weight women with Polycystic Ovary Syndrome or Hashimoto’s Thyroiditis - preliminary study
Autorzy:
Kamińska, W.
Wiśniewska, K.
Okręglicka, K.
Pazura, I.
Nitsch-Osuch, A.
Powiązania:
https://bibliotekanauki.pl/articles/28761656.pdf
Data publikacji:
2023
Wydawca:
Instytut Medycyny Wsi
Źródło:
Annals of Agricultural and Environmental Medicine; 2023, 30, 1; 111-117
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Takayasu’s arteritis: a rare disease in Poland
Autorzy:
Kanecki, K.
Nitsch-Osuch, A.
Tyszko, P.Z.
Goryński, P.
Smolarczyk, R.
Suchta, K.
Powiązania:
https://bibliotekanauki.pl/articles/2081905.pdf
Data publikacji:
2018
Wydawca:
Instytut Medycyny Wsi
Tematy:
vasculitis
epidemiology
aortoarteritis
pulseless disease
granulomatous arteritis
rural regions
urban regions
Opis:
Introduction. Takayasu’s arteritis (TA) is a rare and potentially life-threatening granulomatous large-vessel vasculitis that involves mostly in the aorta and its proximal branches, and occurs most commonly in young females. This study measures the incidence and prevalence of TA, and assesses the gender distribution and territorial differences in the occurrences of this disease in Poland over a five-year period. To the best of our knowledge, this is the first evaluation of this rare disease in Poland based on a hospital morbidity database. Materials and method. Analyses were performed with population-based administrative data obtained from a national hospital morbidity study carried out between January 2011 – December 2015 by the Polish National Institute of Public Health. Yearly incidence rates and prevalence of TA were calculated using the number of TA patients and corresponding census data for the overall Polish population. Results. Data included 660 hospitalization records. The final study sample comprised 177 patients: 154 female (87%) and 23 male (13%) with first-time hospitalization for TA. The mean age was 45.4years (95% CI: 42.9–47.8; SD 16.8; range 4–81 years), median 47. The incidence rate of TA was estimated at 0.92 per million per year (95% CI: 0.68–1.16). Five-year TA prevalence was estimated to be 4,6 per million. Incidence rates of TA did not vary significantly between more urban and more rural regions. Conclusions. The incidence of TA in Poland was similar or lower to data reported by other European countries. The study provides epidemiological data on TA in Poland that may be useful while comparing it with other geographical regions.
Źródło:
Annals of Agricultural and Environmental Medicine; 2018, 25, 3; 469-472
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Neutralization efficiency of alcohol based products used for rapid hand disinfection
Autorzy:
Chojecka, A.
Tarka, P.
Kierzkowska, A.
Nitsch-Osuch, A.
Kanecki, K.
Powiązania:
https://bibliotekanauki.pl/articles/874915.pdf
Data publikacji:
2017
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
neutralization
hygienic behaviour
disinfection
ethanol
bactericidal activity
hand
Opis:
Background. Alcohols are the most commonly used active substances in preparations for quick hand disinfection. They should be bactericidal in very short contact time. PN-EN 13727 + A2: 2015-12 standard, for testing hygienic and surgical handrub disinfection preparations, provides mandatory test conditions of disinfectants in contact times with the range of 30 s to 60 s (hygienic handrub disinfection) and 60 s to 5 min (surgical handrub disinfection). A short contact times for hand hygiene products require a short time of neutralization process. For contact times less than or equal to 10 minutes, the estimated neutralization time is 10 s ± 1 s. Neutralization is a process that abolishes the action of disinfectants. Correct application of this process allows for proper use of disinfectants in practice and its biocidal effect. Objectives. Verification of the effectiveness of 10-second neutralization time of alcohol based preparations for hygienic handrub disinfection. Materials and Method. Neutralization of two products with different ethanol content (89% and 70%) for hygienic handrub disinfection according to PN-EN 13727 + A2: 2015-12 was investigated. The effectiveness of the neutralizer was assessed by determining toxicity of neutralizer, activity of residual effects of the tested products and their derivatives produced during neutralization (10 s) for test organisms (Staphylococcus aureus ATCC 6538; Pseudomonas aeruginosa ATCC 15442; Enterococcus hirae ATCC 10541; Escherichia coli K12 NCTC 10538). Results. The 10-second neutralization time was sufficient to eliminate the residual activity of products for hygienic handrub disinfection with differentiated ethanol concentration. The neutralizer used did not show toxicity to bacteria and did not produce toxic products with tested preparations after neutralization. Conclusions. The use of 10-second neutralization time allows in a precise way designate the contact times for hygienic handrub disinfection products.
Wprowadzenie. Alkohole są substancjami aktywnymi najczęściej stosowanymi w preparatach do szybkiej dezynfekcji rąk. Powinny one działać dezynfekcyjnie w bardzo krótkich czasach kontaktu. Norma PN-EN 13727+A2: 2015-12 przeznaczona do badania preparatów do higienicznej i chirurgicznej dezynfekcji rąk przewiduje obligatoryjne warunki badania preparatów w czasach kontaktu w zakresie od 30 s do 60 s (higieniczna dezynfekcja rąk) i od 60 s do 5 minut (chirurgiczna dezynfekcja rąk). Krótkie czasy kontaktu produktów przeznaczonych do higieny rąk wymagają zastosowania krótkiego procesu neutralizacji. Dla czasów kontaktu poniżej lub równych 10 minut przewidziany czas neutralizacji wynosi 10 s ± 1s. Neutralizacja jest procesem znoszącym działanie preparatów dezynfekcyjnych. Prawidłowe wykonanie tego procesu warunkuje prawidłowe zastosowanie preparatu w praktyce i jego działanie biobójcze. Cel. Sprawdzenie skuteczności 10-sekundowego czasu neutralizacji wobec preparatów na bazie alkoholu przeznaczonych do higienicznej dezynfekcji rąk. Materiały i metody. Badano etap neutralizacji dwóch produktów o różnej zawartości etanolu (89% i 70%) przeznaczonych do higienicznej dezynfekcji rąk wg normy PN-EN 13727+A2: 2015-12. Skuteczność neutralizatora oceniano poprzez określenie braku wpływu toksyczności neutralizatora oraz działania resztkowego badanych produktów lub ich pochodnych powstałych w czasie neutralizacji (10 s ± 1s) na badane organizmy testowe (Staphylococcus aureus ATCC 6538; Pseudomonas aeruginosa ATCC 15442; Enterococcus hirae ATCC 10541; Escherichia coli K12 NCTC 10538). Wyniki. 10-sekundowy czas neutralizacji był wystarczający do zniesienia aktywności produktów o zróżnicowanej zawartości etanolu przeznaczonych do higienicznej dezynfekcji rąk. Zastosowany neutralizator nie wykazywał działania toksycznego wobec bakterii oraz nie tworzył toksycznych produktów z badanymi preparatami po neutralizacji. Wnioski. Zastosowanie 10-sekundowego czasu neutralizacji pozwala w precyzyjny sposób wyznaczyć czasy działania produktów przeznaczonych do higienicznej dezynfekcji rąk.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2017, 68, 4
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Congenital herpes simplex virus infection among hospitalized infants in Poland
Autorzy:
Rząd, M.
Nitsch-Osuch, A.
Tyszko, P.Z.
Goryński, P.
Bogdan, M.
Lewtak, K.
Kanecki, K.
Powiązania:
https://bibliotekanauki.pl/articles/28762711.pdf
Data publikacji:
2021
Wydawca:
Instytut Medycyny Wsi
Źródło:
Annals of Agricultural and Environmental Medicine; 2021, 28, 4; 612-616
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Congenital cytomegalovirus infections in Poland - a national hospital register-based study
Autorzy:
Kanecki, K.
Nitsch-Osuch, A.
Goryński, P.
Bogdan, M.
Barańska, A.
Tyszko, P.
Powiązania:
https://bibliotekanauki.pl/articles/28762965.pdf
Data publikacji:
2020
Wydawca:
Instytut Medycyny Wsi
Źródło:
Annals of Agricultural and Environmental Medicine; 2020, 27, 4; 574-578
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Paget disease of bone among hospitalized patients in Poland
Autorzy:
Kanecki, K.
Nitsch-Osuch, A.
Goryński, P.
Bogdan, M.
Tarka, P.
Tyszko, P.Z.
Powiązania:
https://bibliotekanauki.pl/articles/2081574.pdf
Data publikacji:
2018
Wydawca:
Instytut Medycyny Wsi
Tematy:
Paget’s disease of bone
hospitalization
rural population
urban population
risk factors
Opis:
Introduction. Paget’s disease (PDB) is a focal disorder of bone remodeling that occurs commonly in older people with decreasing prevalence reported in European countries. This disease is most often asymptomatic, but it can cause a variety of medical complications resulting in considerable morbidity and reduced quality of life. There is little information regarding the epidemiology of PDB in Poland. To the best of the authors’ knowledge, this is the first large epidemiological analysis of this disease in Poland. Objective. The aim of this study was to analyze factors that may be related to the PDB epidemiology among hospitalized patients in Poland. Materials and method. The analysis was conducted on the basis of population-based administrative data, taken from a Polish hospital morbidity study carried out by the National Institute of Public Health between January 2008 – December 2014. Results. Analyzed data covered 662 hospitalization records. The final study sample comprised 94 (41.8%) male and 131 (58.2%) female patients with first-time hospitalizations for PDB, with a significant predominance of females (P<0.02), and the predominance of patients living in urban (73%) than in rural areas (27%), P<0.001. The average age of the sample was 56.8 years (CI: 54.3–59.3; SD 18.8; range 1–93 years). The number of PDB cases hospitalized in Poland significantly decreased during the analyzed period of time. Conclusions: PDB is a rare disease with decreasing trends observed among hospitalized patients in Poland. The study results may suggest the existence of environmental risk factors for the development of PDB.
Źródło:
Annals of Agricultural and Environmental Medicine; 2018, 25, 1; 182-185
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Colonization with drug-resistant pathogens among patients in long-term care facilities and under home hospice care – a cross-sectional study
Autorzy:
Dawgiałło, M.
Zasztowt-Sternicka, M.
Jagielska, A.
Kuthan, R.
Kanecki, K.
Nitsch-Osuch, A.
Powiązania:
https://bibliotekanauki.pl/articles/28763025.pdf
Data publikacji:
2023
Wydawca:
Instytut Medycyny Wsi
Źródło:
Annals of Agricultural and Environmental Medicine; 2023, 30, 4; 606-610
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Asbestosis hospitalizations in Poland (2006–2016): results from the National Hospital Discharge Registry
Autorzy:
Kanecki, K.
Kosińska, I.
Tyszko, P.Z.
Nitsch-Osuch, A.
Goryński, P.
Zieliński, G.
Powiązania:
https://bibliotekanauki.pl/articles/2085542.pdf
Data publikacji:
2020
Wydawca:
Instytut Medycyny Wsi
Tematy:
public health
environmental health
lung disease
occupational exposure
Opis:
Introduction and objective. Occupational asbestos exposure is one of the major public health issues. Although asbestos use in Poland has decreased, asbestosis continues to remain an important health concern in the area of occupational medicine. The aim of the study is to perform a descriptive analysis of hospitalization cases in patients suffering from asbestosis in Poland. Materials and method. The authors used hospital discharge records to conduct a retrospective, population-based study. To estimate the asbestosis hospitalization rate, data from the Nationwide General Hospital Morbidity Study conducted by the National Institute of Public Health were used. Events were defined as in-patient hospital discharges during 2006–2016. 1,101 hospitalization records of 764 patients were included in the study. Results. In the study group of first-time hospitalized patients, the mean and median ages were 68.1 and 69 years, respectively; CI: 67.3–68.9; SD: 11.1, min-max:16–99 years. In this group, significant gender differences were observed (560 males vs. 204 female; P<0.001). No statistical differences were observed regarding the place of residence. During the observation period, 61 in-hospital deaths were reported (8% of all patients), 40 of whom (5.2 % of all patients) took place during the first-time hospitalizations. Asbestosis hospitalizations were mainly clustered in the south-western region, whereas the highest hospitalization rates were clustered in several areas of Poland. Conclusions. The authors believe this study to be the first evaluation of asbestosis in Poland made on the basis of the hospital morbidity database. The data presented may be helpful in comparative studies on the epidemiology of asbestosis across European countries.
Źródło:
Annals of Agricultural and Environmental Medicine; 2020, 27, 2; 284-289
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The cysteine-rich receptor-like kinase family in Arabidopsis – a phenotypic framework for stress responses and ROS signaling
Autorzy:
Bourdais, G.
Burdiak, P.
Gauthier, A.
Nitsch, L.
Rayapuram, C.
Salojarvi, J.
Tri Anggoro, D.
Glow, D.
Zhou, J.
Kaufholdt, D.
Oracz, K.
Idanheimo, N.
Willem Borst, J.
Collinge, D.B.
Karpinski, S.
L yngkjaer, M.F.
Robatzek, S.
Kangasjarvi, J.
Wrzaczek, M.
Powiązania:
https://bibliotekanauki.pl/articles/79974.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
conference
receptor-like kinase
cysteine
Arabidopsis
reactive oxygen species
stress response
signalling
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2013, 94, 2
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-15 z 15

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies