Tytuł:
Temperature Distribution in a Steel Beam-to-Column Joint when Exposed to Fire. Part 1: End-Plate Joint
Autorzy:
Maślak, M.
Suchodoła, M.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/105584.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
beam-to-column steel end-plate joint
fire
temperature distribution
joint components
numerical simulation
Opis:
Temperature distribution usually observed in steel beam-to-column end-plate joint after 15 minutes of its standard fire exposure is presented and discussed in detail. Two types of joints are analysed for comparative purposes. The first one is a pure steel connection while the other is covered by a reinforced concrete slab. Numerical simulation of the considered joint heating scenario was performed using the 3D model in the ANSYS environment. Some results were additionally verified by simpler calculations carried out on 2D models using the SAFIR computer program. It is emphasized that due to the local accumulation of many massive steel plates the representative temperature values identified in particular joint components are significantly lower than those which at the same time are measured in beam and column outside the connection. This means that the classic assumption of even temperature over the entire length of all the structural elements of a frame load-bearing structure exposed to fire at any time during such fire, without distinguishing in the formal model any cooler nodal elements, is always safe but very conservative. In addition, as the fire develops the differentiation between the temperature values relating to the beam web and to the beam flanges becomes more visible. This effect is particularly significant in the presence of a massive floor slab adjacent the upper flange of a frame I-beam which effectively cools it.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 25-34
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature Distribution in a Steel Beam-to-Column Joint when Exposed to Fire. Part 2: Flange-Plates and Web-Cleats Joint
Autorzy:
Maślak, M.
Suchodoła, M.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/104693.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
beam-to-column joint
flange-plates joint
web-cleats joint
temperature distribution
section factor
numerical simulation
Opis:
In the second part of this paper the temperature distribution is analysed for a thermally uninsulated steel beam-to-column flange-plates and web-cleats joint after 15 minutes of its exposure to a fully developed fire. Two types of such a joint are considered separately, firstly the pure steel connection with a beam and a column evenly heated on all four sides and then the analogous one, but with a massive reinforced concrete floor slab lying on the upper beam flange. In the latter case the joint beam is heated only on three sides. In addition, in each of the analysed joint the beams of two sizes are analysed independently for comparative purposes. Those that are made of the bigger I-section have a more slender web, while the smaller ones are more stocky. However, the smaller I-section heats faster than the bigger one because the section factor calculated for it has a greater value. In general, it can be concluded that in all the joints considered by the authors the steel temperature turned out to be much lower than that measured outside these joints. Moreover, a significant difference is observed in the temperature values identified in the beam web and in the beam flanges. Finally, the temperature distribution obtained from a numerical simulation and identified in the selected cross-sections of the joint beam in the case of a joint with adjacent floor slab is referred to the analogous distribution recommended for use in such circumstances in the standard EN 1993-1-2.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 103-114
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Użyteczność modelu obliczeniowego pojedynczej ramy poprzecznej w szacowaniu odporności ogniowej hali stalowej
The Usability of a Computational Model of a Single Transverse Frame in the Fire Resistance Assessment of an Entire Steel Hall
Autorzy:
Maślak, M.
Tkaczyk, A.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/373628.pdf
Data publikacji:
2017
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
hala stalowa
odporność ogniowa
rama poprzeczna
model obliczeniowy
podejście Merchanta-Rankine’a
nośność sprężysta
nośność plastyczna
temperatura krytyczna
steel hall
fire resistance
transverse frame
computational model
Rankine-Merchant approach
purely elastic resistance
purely plastic resistance
critical temperature
Opis:
Cel: Celem zaprezentowanych rozważań jest wypracowanie miarodajnej odpowiedzi na pytanie o wiarygodność stosowania modelu obliczeniowego pojedynczej ramy poprzecznej wyizolowanej ze złożonego ustroju nośnego hali stalowej w ocenie odporności ogniowej tej hali. Badanie zachowania się w pożarze pojedynczej ramy poprzecznej poprzez weryfikację kolejnych potencjalnie możliwych form jej zniszczenia umożliwia specyfikację poszukiwanej odporności interpretowanej jako określona dla tej ramy temperatura krytyczna, niezależna od przyjętego scenariusza rozwoju pożaru. Temperatura ta kojarzona jest jednoznacznie z osiągnięciem przez ustrój nośny analizowanej ramy stanu granicznego nośności ogniowej. Metody: Do specyfikacji temperatury krytycznej wybranej ramy proponuje się procedurę obliczeniową opartą na uogólnionej na przypadek pożaru formule Merchanta-Rankine’a. Kwantyfikuje ona miarodajną nośność badanej ramy poprzez interakcję odpowiednich nośności skojarzonych z czysto sprężystą i czysto plastyczną formą jej zniszczenia. Opisano ograniczenia wybranej przez autorów metody oceny wynikające z konieczności akceptacji wielu upraszczających założeń formalnych. Pokazano również, jak na otrzymane rezultaty wpływa stopień złożoności zastosowanego modelu obliczeniowego. Wyniki: Weryfikację i walidację proponowanej w artykule procedury obliczeniowej przeprowadzono porównując przemieszczenia wybranych węzłów ramy poprzecznej hali stalowej analizowanej dla warunków pożaru. Chodziło o sprawdzenie, jakiego typu i jak duże rozbieżności wynikają z zastosowania uproszczonego modelu dwuwymiarowego pojedynczej ramy w stosunku do wyników otrzymanych z analizy pełnego trójwymiarowego modelu ustroju nośnego całej hali. Wnioski: Wykazano, że uproszczony model obliczeniowy pojedynczej ramy poprzecznej hali stalowej jest wystarczająco wiarygodny w przypadku, gdy o odporności ogniowej tej ramy decyduje pierwsza faza pożaru, gdy nie ma jeszcze znaczącego przyrostu prędkości deformacji elementów nośnych. Jeżeli jednak badana rama zapewnia bezpieczne przenoszenie przyłożonych do niej obciążeń także wtedy, gdy mamy do czynienia z dużymi deformacjami i znacznym osłabieniem elementów decydujących o nośności ramy, to oszacowanie prognozowanej odporności na podstawie modelu ograniczonego do pojedynczej ramy poprzecznej może być nazbyt optymistyczne. Nie uwzględnia bowiem przyspieszania ugięcia rygla przez ogrzane w pożarze płatwie dachowe rozciągane osiowo wskutek tak zwanego efektu cięgna.
Aim: The aim of these considerations is to achieve a reliable answer to the question about the credibility of the use of a simple computational model with a single transverse frame isolated from a complex load-bearing structure of an entire steel hall in the fire resistance-evaluation of such a hall. The study of the behaviour of a simple transverse frame under fire conditions through checking all its potential failure modes allows to specify the required fire resistance which can be interpreted as the critical temperature set especially for this frame and being independent of the fire scenario adopted for the analysis. This temperature is unequivocally associated with the reaching by the frame load-bearing structure of the fire-resistance limit state. Methods: The classical Rankine-Merchant formula generalised to the fire case is proposed to be used in the specification of the critical temperature for the transverse frame selected for the analysis. It quantifies the reliable bearing capacity of the tested frame through the interaction of the appropriate capacities associated with purely elastic and purely plastic failure modes. The limitations of the assessment method recommended by the authors are described in detail, resulting from the need for the acceptance of many formal assumptions simplifying the analysis. The impact of the complexity of the formal model adopted for the assessed frame fire-resistance evaluation on the obtained results is also verified. Results: Both the verification and the validation of the computational procedure proposed by the authors in this article were performed by comparing the displacements of the selected nodes in the transverse frame analysed for fire conditions. The idea was to check what type of differences are obtained through the use of a simplified two-dimensional computational model of a single frame in relation to the corresponding results obtained when a complex three-dimensional model of the entire hall is considered, and how big they are. Conclusions: It has been shown that the simplified computational model of a single transverse frame selected from the entire steel hall seems to be sufficiently reliable in the case in which fire resistance of such a frame is determined by the first phase of this fire, when the deformation rate of all bearing members is not yet significantly increased. However, if the tested frame also ensures the safe transfer of all loads applied to it when we are dealing with large deformations and large weakening of the members determining the real capacity of such a frame then the assessment of the predicted fire resistance obtained on the basis of the model limited to the analysis of only a single transverse frame might prove to be too optimistic. It does not account for the acceleration of the deflection of the frame beam due to the action of the heated purlins being in tension as a consequence of the so called catenary effect.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2017, 45, 1; 52-67
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ lokalizacji źródła ognia na rozwój pożaru w wielkopowierzchniowym halowym obiekcie handlowym
The Impact of the Fire Source Location on Fire Development in a Large-Space Steel Commercial Building
Autorzy:
Maślak, M.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/372699.pdf
Data publikacji:
2017
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
hala handlowa
pożar lokalny
rozwój pożaru
warunki wentylacji
temperatura spalin
lokalizacja źródła ognia
steel commercial building
localised fire
fire development
ventilation conditions
fire-plume-gas temperature
fire-source location
Opis:
Cel: Celem prezentowanych rozważań jest pokazanie, że rozwój pożaru w wielkopowierzchniowym obiekcie handlowym może mieć różny przebieg, zależny od tego, w jakiej lokalizacji miała miejsce jego inicjacja. Hale tego typu charakteryzują się zwykle dużą powierzchnią przy stosunkowo małej wysokości, co utrudnia cyrkulację powietrza i odprowadzenie gazów spalinowych. Dodatkowym ograniczeniem tłumiącym swobodny rozwój pożaru jest w tym przypadku mały wskaźnik otworów. Wszystko to sprawia, że pożarem miarodajnym do oceny bezpieczeństwa takich obiektów powinien być raczej pożar zlokalizowany, dla którego nie doszło do rozgorzenia i wyrównania temperatury spalin w całej strefie pożarowej. Metody: W pracy rozważa się rozwój pożaru lokalnego zainicjowanego w trzech alternatywnych lokalizacjach różniących się położeniem źródła ognia i jego odległością od otworów bramowych wentylujących strefę pożarową. Do numerycznego modelowania pożaru wykorzystano program FDS specyfikujący zmieniające się w czasie przestrzenne mapy temperatury spalin na podstawie uogólnionych równań dynamiki płynów ze zmiennymi termodynamicznymi i aerodynamicznymi. Wyniki: Prezentowane wyniki, otrzymane w dotychczasowych badaniach, dotyczą przypadku hali handlowej, w której nie zastosowano wymaganych prawem klap dymowych, instalacji tryskaczowych ani żadnych innych środków czynnej ochrony przed ogniem. W dalszych pracach do modelowania planuje się wprowadzać kolejne elementy formalne, pozwalające na rozeznanie wpływu tego typu zabezpieczeń na rozwój pożaru. Uzyskane profile temperatury gazów spalinowych, skojarzone z kolejnymi rozpatrywanymi lokalizacjami pożaru, w celach porównawczych odniesiono do analogicznych wyników otrzymanych po zastosowaniu różnego typu modeli analitycznych zalecanych do stosowania w profesjonalnej literaturze. Wnioski: Uzyskane rezultaty wydają się potwierdzać konstatację, że modelowanie rozwoju pożaru lokalnego jedynie na podstawie dostępnych modeli analitycznych nie musi prowadzić do wystarczająco wiarygodnych oszacowań prognozowanego bezpieczeństwa zwłaszcza wtedy, gdy rozwój ten zależy od czynników nie branych pod uwagę przy formułowaniu tych modeli. Przykładem tego typu ograniczeń jest sytuacja rozpatrywana w niniejszym artykule, dla której intensywność przewidywanego pożaru zależy od lokalizacji źródła ognia, co w konsekwencji różnicuje realną dostępność tlenu podtrzymującego spalanie.
Aim: The aim of this paper is to show that fire development in a large-space steel commercial building may have a different intensity depending on the location in which the fire originated. Buildings of this type are usually characterised by a large area with a relatively low height, which makes air circulation and fire-gas evacuation difficult. The low value of the opening factor in this case is an additional constraint preventing fire from developing freely. All this makes a localised fire which has not reached a flashover and for which the fire-plume-gas temperature has not become uniform throughout the fire compartment a representative pattern which should be considered to assess the fire safety of such buildings. Methods: This paper investigates the development of a localised fire which originates in three alternative locations differing in the position of the fire source and in the distance to the gate openings which ventilate the fire compartment. The FDS software is used for numerical fire modelling, specifying the time-varying spatial maps of the fire-plume-gas temperature on the basis of the equations taken from the fluid dynamics methodology with thermodynamic and aerodynamic variables. Results: The presented results, obtained hitherto, involve a steel commercial building which has no smoke vents, which are legally required, and sprinkler systems or any other active fire protection solutions. The plan for future works is to include additional formal components for modelling purposes to explore the impact of these safety measures on fire development. The fire-plume-gas temperature profiles associated with the individual fire locations investigated are linked for comparative purposes to the corresponding results yielded by the analytical models recommended by the professional literature. Conclusions: The obtained results seem to support the assertion that the modelling of a localised fire only on the basis of the existing analytical models does not necessarily lead to sufficiently reliable evaluations of the projected safety, particularly when this development depends on the factors which have not been accounted for in such models. An example of such a situation is the case investigated in this article, when the intensity of the anticipated fire depends on the location of the fire source, which involves varying oxygen availability necessary to sustain combustion.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2017, 45, 1; 154-169
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies