Tytuł:
Applying the coagulation and reverse osmosis for water recovery from evaporative water
Zastosowanie koagulacji i odwróconej osmozy do odzysku wody z wód wyparnych
Autorzy:
Michel, M.M.
Reczek, L.
Siwiec, T.
Rudnicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/81589.pdf
Data publikacji:
2014
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Opis:
Evaporative water from the concentration of yeast slurry is a potential raw material for water recovery. It is characterized by low pH (4.6–6.3), increased turbidity (3.65–13.7 NTU), and high content of total organic carbon (356–754 mg/L). Its treatment in the volume coagulation process using NaOH and coagulant PIX 111, was studied. Water turbidity was lowered to a value below 1 NTU, but coagulation did not allow for the removal of organic compounds. Coagulation was effective at temperatures of 20 and 40°C. Pre- -treatment of the feed water for RO included alkalization, coagulation, sedimentation, and 5 μm fine filtration (variant I), as well as single 5 μm fine filtration (variant II as a blank). In variant I the feed with improved properties was achieved. Membrane filtration allowed for effective desalination of evaporative water, 98 and 73% conductivity retention was obtained, depending on the method of the feed pre-treatment. The organic compounds were removed less effi ciently, at 94 and 84%, respectively.
Wody wyparne z zatężania gęstwy drożdżowej stanowią potencjalny surowiec do odzysku wody. Charakteryzują się niskim odczynem (pH 4.6–6.3), podwyższoną mętnością (3.65–13.7 NTU) i dużą zawartością ogólnego węgla organicznego (356–754 mg/L). Badano ich oczyszczanie w procesie koagulacji objętościowej, stosując NaOH oraz koagulant PIX 111. Obniżono mętność wody do wartości poniżej 1 NTU, jednak koagulacja nie pozwalała na usunięcie związków organicznych. Koagulacja przebiegała efektywnie w 20 i 40°C. Oczyszczanie wstępne nadawy do RO obejmowało alkalizację, koagulację, sedymentację i filtrację dokładną (wariant I) oraz filtrację dokładną (wariant II jako blank). W wariancie I otrzymano nadawę o lepszych właściwościach. Filtracja membranowa pozwoliła na skuteczne odsolenie wód wyparnych, uzyskano 98 i 73% retencję przewodności w zależności od sposobu przygotowania nadawy. Związki organiczne były usuwane z mniejszą efektywnością, odpowiednio 94 i 84%.
Źródło:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation; 2014, 46, 4
0208-5771
Pojawia się w:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Treatment of evaporative water from brewer’s yeast concentration by Fenton and Fenton-like processes
Oczyszczanie wody wyparnej z zatężania gęstwy drożdżowej w procesie Fentona
Autorzy:
Michel, M. M.
Reczek, L.
Siwiec, T.
Rudnicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/204618.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chemical oxidation
COD removal
industrial water
TOC removal
water reuse
utlenianie chemiczne
usuwanie ChZT
woda przemysłowa
usuwanie OWO
ponowne wykorzystanie wody
Opis:
Evaporative water from yeast slurry concentration is acidic, low mineralized and contains large amounts of dissolved organic contaminants. The treatment of evaporative water from yeast slurry concentration by Fenton (Fe(II)/H2O2) and Fenton-like (Fe(III)/H2O2) reactions has been studied. The processes in terms of system variables have been compared: catalyst and oxidant doses, initial pH, temperature of reaction, and the reaction kinetic. For determination of mineralization efficiency the total organic carbon (TOC) in water before and after reactions was measured. The Fenton reaction was more efficient for mineralization of organic compounds: the highest efficiency of TOC removal was 45–50%, while for the Fenton-like it was 20–30%. The pH adjustment of evaporative water in the range of 2–5 did not change the efficiency of treatment. Temperature of 30°C was the most favorable for both reactions. The Lumped Kinetic Model fitted very well the experimental results. The reaction rate analysis indicated that the rate of direct mineralization of organic compounds is similar to the rate of its oxidation to organic intermediates, its selectivity factor was more favorable to the Fenton reaction. The strong correlation between chemical oxygen demand (COD) and TOC in evaporative water after the Fenton and Fenton-like reactions has been determined, providing a simple tool for calculating COD on the basis of values of TOC measurement.
Woda wyparna z zatężania gęstwy drożdżowej jest kwaśna, nisko zmineralizowana i zawiera dużą ilość rozpuszczonych związków organicznych. W pracy badano oczyszczanie wody wyparnej w reakcji Fentona (Fe(II)/H2O2) i pokrewnej (Fe(III)/H2O2). Porównywano procesy przy następujących zmiennych: dawki katalizatorów i utleniacza, pH początkowe, temperatura i kinetyka reakcji. Efektywność oceniano poprzez pomiar ogólnego węgla organicznego przed i po reakcji. Związki organiczne były bardziej skutecznie mineralizowane w reakcji Fentona: najwyższa efektywność usuwania OWO wynosiła 45–50%, a w reakcji pokrewnej jedynie 20–30%. Korekta odczynu wody wyparnej w zakresie 2–5 pH nie wpłynęła na efektywność oczyszczania. Temperatura 30°C była najbardziej korzystna dla obydwu reakcji. Model kinetyczny o parametrach skupionych bardzo dobrze opisywał wyniki badań eksperymentalnych. Analiza szybkości reakcji wykazała, że jest ona zbliżona w przypadku mineralizacji organicznych składników oraz utleniania do produktów pośrednich, a współczynnik selektywności reakcji był korzystniejszy dla procesu Fentona. Określono silną korelację pomiędzy parametrami ChZT i OWO w wodzie po reakcji Fentona i pokrewnej, co może być przydatnym do obliczania ChZT na podstawie pomiaru OWO.
Źródło:
Archives of Environmental Protection; 2018, 44, 3; 11-18
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies