Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Nitsch, K." wg kryterium: Autor


Wyświetlanie 1-6 z 6
Tytuł:
Simple Wide Frequency Range Impedance Meter Based on AD5933 Integrated Circuit
Autorzy:
Chabowski, K.
Piasecki, T.
Dzierka, A.
Nitsch, K.
Powiązania:
https://bibliotekanauki.pl/articles/221804.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impedance
converter
AD5933
system-on-a-chip
measurement
Opis:
As it contains elements of complete digital impedance meter, the AD5933 integrated circuit is an interesting solution for impedance measurements. However, its use for measurements in a wide range of impedances and frequencies requires an additional digital and analogue circuitry. This paper presents the design and performance of a simple impedance meter based on the AD5933 IC. Apart from the AD5933 IC it consists of a clock generator with a programmable prescaler, a novel DC offset canceller for the excitation signal based on peak detectors and a current to voltage converter with switchable conversion ratios. The authors proposed a simple method for choosing the measurement frequency to minimalize errors resulting from the spectral leakage and distortion caused by a lack of an anti-aliasing filter in the DDS generator. Additionally, a novel method for the AD5933 IC calibration was proposed. It consists in a mathematical compensation of the systematic error occurring in the argument of the value returned from the AD5933 IC as a result. The performance of the whole system is demonstrated in an exemplary measurement.
Źródło:
Metrology and Measurement Systems; 2015, 22, 1; 13-24
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory evaluation of rubber linings used in flue gas desulphurization plants by the gravimetric method and impedance spectroscopy
Laboratoryjna ocena wykładzin gumowych używanych w instalacjach odsiarczania spalin, metodą grawimetryczną i spektroskopii impedancyjnej
Autorzy:
Drela, I.
Masalski, J.
Nitsch, K.
Piasecki, T.
Szczygieł, B.
Powiązania:
https://bibliotekanauki.pl/articles/172882.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odsiarczanie spalin
metoda grawimetryczna
metoda spektroskopii impedancyjnej
wykładzina gumowa
materiał powłokowy
flue gases desulphurization
gravimetric method
impedance spectroscopy method
rubber linings
lining material
Opis:
Special cells made of austenitic steel were employed to carry out accelerated tests of lining materials in the autoclave at elevated temperature and at a pressure gradient along the sample’s thickness. The tests were carried out on three kinds of rubber linings: prevulcanized soft two-ply lining based on bromobutyl rubber, selfvulcanizing two-ply lining based on bromobutyl rubber and prevulcanized lining based on chlorobutyl rubber. Distilled water, 1 % aqueous solution of HCl and aqueous solution containing 50 g/dm3 of sulphuric acid and 26 g/dm3 of sodium bisulphate (IV) were used as the working medium in the tests. The temperature of the working medium in the autoclave was kept at 110±2°C and the sample exposure time amounted to 48 hours. The change in the mass of the samples after the proper time of exposure in the autoclave was determined by the gravimetric method. A measuring system made up of an Agilent 4294A high-frequency impedance analyzer and a low-frequency impedance analyzer with a Keithley 428 current/voltage transducer was used to perform measurements in a frequency range from 0.1 mHz to 10 MHz at activation with an voltage amplitude of 1 V[RMS]. The impedance measurement results show that despite the severe corrosive conditions in the autoclave and the gain in the mass of the samples, the tested coating materials did not undergo significant degradation during their exposure and keep good dielectric and protective properties.
Zastosowano specjalne komórki ze stali austenitycznej, umożliwiające przeprowadzenie przyspieszonych badań materiałów powłokowych w autoklawie w warunkach podwyższonej temperatury i gradientu ciśnienia na grubości próbki. Badania wykonano dla trzech rodzajów wykładzin gumowych: wstępnie wulkanizowanej miękkiej wykładziny dwuwarstwowej na bazie kauczuku bromobutylowego, dwuwarstwowej samowulkanizującej się wykładziny na bazie kauczuku bromobutylowego i wstępnie wulkanizowanej wykładziny na bazie kauczuku chlorobutylowego). W badaniach jako medium robocze stosowano wodę destylowaną, 1% roztwór wodny kwasu solnego oraz roztwór wodny zawierający 50 g/dm3 kwasu siarkowego i 26 g/dm3 wodorosiarczanu (IV) sodu. Temperaturę medium roboczego w autoklawie utrzymywano w zakresie 110±2°C, a czas ekspozycji próbek wynosił 48 godz. Metodą grawimetryczną oznaczano zmianę masy próbek po odpowiednim czasie ekspozycji próbek w autoklawie, a wykorzystując system pomiarowy zestawiony z wysokoczęstotliwościowego analizatora impedancji Agilent 4294A oraz niskoczęstotliwościowego analizatora impedancji z przetwornikiem prąd-napięcie Keithley 428 wykonywano pomiary w zakresie częstotliwości od 0,1 mHz do 10 MHz przy pobudzeniu o amplitudzie napięcia przemiennego 1 V[RMS]. Otrzymane wyniki badań impedancyjnych pozwalają stwierdzić, że badane materiały powłokowe, pomimo ostrych warunków korozyjnych w autoklawie i zwiększenia masy próbek, nie uległy znaczącej destrukcji podczas ekspozycji i zachowały dobre właściwości dielektryczne i ochronne.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 27-36
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hyperfine Field in YIG with Charged Substitution
Autorzy:
Kohout, J.
Štĕpánková, H.
Englich, J.
Novák, P.
Kučera, M.
Nitsch, K.
Powiązania:
https://bibliotekanauki.pl/articles/2013158.pdf
Data publikacji:
2000-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
76.60.-k
75.50.Gg
Opis:
$\text{}^{57}$Fe NMR spectra were measured on thin films of yttrium iron garnet with divalent (Ca$\text{}^{2+}$) and tetravalent (Ge$\text{}^{4+}$) cation substitutions using the spin echo technique at 4.2 K. A series of Y$\text{}_{3-x}$Ca$\text{}_{x}$Fe$\text{}_{5-x}$Ge$\text{}_{x}$O$\text{}_{12}$ samples with 0 ≤ x ≤ 0.0 5 was prepared by an epitaxial growth from BaO/B$\text{}_{2}$O$\text{}_{3}$/BaF$\text{}_{2}$ flux on gadolinium gallium garnet substrate. Satellite lines corresponding to the iron ions having the Ge$\text{}^{4+}$ and Ca$\text{}^{2+}$ in their neighbourhood were identified. The sample with the germanium content of x(Ge) = 0.004 and (110) substrate orientation was used for a detailed study: NMR spectra of this sample were measured in an external magnetic field of 0.1 T applied along several directions in the plane of the film. The modification of the isotropic part and the anisotropy tensor of the hyperfine interaction caused by the Ge$\text{}^{4+}$ substituent were obtained from the experimental data. The results were compared with those previously reported for trivalent substitution (Ga$\text{}^{3+}$).
Źródło:
Acta Physica Polonica A; 2000, 97, 3; 519-522
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atmospheric Pressure Plasma Jet for Mass Spectrometry
Autorzy:
Babij, M.
Gotszalk, T.
Kowalski, Z.
Nitsch, K.
Silberring, J.
Smoluch, M.
Powiązania:
https://bibliotekanauki.pl/articles/1198872.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.50.Dg
82.80.Ms
Opis:
The atmospheric pressure plasma is much advantageous over low pressure plasmas in various aspects, e.g. vacuum-free operation, relative low cost, flexibility of a continuous process. Among various plasmas generated in atmospheric pressure discharges there are cold plasma jets that represent a technology of great application promise (industry, medicine, biology). To generate low-temperature plasmas at atmospheric pressure the dielectric barrier discharge can be used. It is suitable for the atomization of volatile species and can also be served as a ionization source for ambient mass and ion mobility spectrometry. As the discharge is generated in a restricted electrode structure, a plasma jet (plume) is usually formed outside the electrode region (that provides spatial separation of the plasma generation and surface processing regions). The paper presents a source based on a plasma jet established at the end of a capillary dielectric barrier discharge at atmospheric pressure and its application to mass spectrometry. The structure of the jet generator consists of piezoelectric transformer and two concentric and symmetric electrodes, between which the working gas flows at definite rate. Besides the source description early results of spectroscopic analysis are also given.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1260-1262
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Antisite Defects in Epitaxial Films of Lutetium Doped Yttrium Iron Garnets Studied by Nuclear Magnetic Resonance
Autorzy:
Chlan, V.
Štěpánková, H.
Englich, J.
Řezníček, R.
Kouřil, K.
Kučera, M.
Nitsch, K.
Powiązania:
https://bibliotekanauki.pl/articles/1534129.pdf
Data publikacji:
2010-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
75.50.Gg
76.60.-k
76.60.Lz
68.35.Dv
68.55.Ln
Opis:
Series of lutetium doped yttrium iron garnet films is studied by means of $\text{}^{57}Fe$ nuclear magnetic resonance. Satellite spectral lines are resolved and identified in the spectra and concentrations of lutetium in dodecahedral sites as well as yttrium/lutetium antisite defects in octahedral sites are estimated. Compared to yttrium, lutetium cations are found to have stronger disposition towards creating the antisite defects.
Źródło:
Acta Physica Polonica A; 2010, 118, 5; 846-847
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impedance Sensors Made in PCB and LTCC Technologies for Monitoring Growth and Degradation of Pseudomonal Biofilm
Autorzy:
Chabowski, K.
Junka, A. F.
Piasecki, T.
Nowak, D.
Nitsch, K.
Smutnicka, D.
Bartoszewicz, M.
Moczała, M.
Szymczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/221326.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Pseudomonas aeruginosa
biofilm
interdigitated sensor
impedance spectroscopy
Opis:
The suitability of low-cost impedance sensors for microbiological purposes and biofilm growth monitoring was evaluated. The sensors with interdigitated electrodes were fabricated in PCB and LTCC technologies. The electrodes were golden (LTCC) or gold-plated (PCB) to provide surface stability. The sensors were used for monitoring growth and degradation of the reference ATCC 15442 Pseudomonas aeruginosa strain biofilm in invitro setting. During the experiment, the impedance spectra of the sensors were measured and analysed using electrical equivalent circuit (EEC) modelling. Additionally, the process of adhesion and growth of bacteria on a sensor’s surface was assessed by means of the optical and SEM microscopy. EEC and SEM microscopic analysis revealed that the gold layer on copper electrodes was not tight, making the PCB sensors susceptible to corrosion while the LTCC sensors had good surface stability. It turned out that the LTCC sensors are suitable for monitoring pseudomonal biofilm and the PCB sensors are good detectors of ongoing stages of biofilm formation.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 369-380
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies