Tytuł:
Porównanie czasu odnowy w czynnościowej próbie termicznej wykonanej dwiema metodami u osób z acrohomoiotermicznym typem regulacji naczyń obwodowych
Comparison of recovery time in a cold provocation test performed by two methods in subjects with acrohomoiothermic regulation of the peripheral circulation
Autorzy:
Harazin, Barbara
Zieliński, Grzegorz
Malinowska-Borowska, Jolanta
Kałamarz, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1039977.pdf
Data publikacji:
2009
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
akrohomoiotermiczna regulacja
czas odnowy
czynnościowa próba termiczna
Opis:
BACKGROUND A quantitative evaluation of vascular response to cold provocation is determined by measurements of the fi nger skin temperature. In the study two methods of cold exposure were used to assess the eff ect of water temperature and immersion duration on recovery time in subjects with the homoiothermic regulation. MATERIAL AND METHODS In the study two cold provocation tests were performed. One test consisted of a 10-min immersion of the both hands in cold water at 14 °C (Polish requirements) and the second one adequately, of a 5-min immersion in cold water at 12 °C (ISO 14835-1:2004 standard). Twenty young (22-24 years) and health subjects took part in each test. Finger skin temperature was measured on all fingers of both hands before and after immersion. RESULTS The mean recovery time of the cold provocation test was not statistically significant in the group examined by ISO 14835-1:2004 standard requirements in comparison with the group examined by the method used in Poland. CONCLUSIONS Immersion parameters used in the cold provocation test performed in acrohomoiothermics do not have a significant effect on recovery time.
WSTĘP Ilościowa ocena reakcji naczyniowej na prowokację chłodem jest określana za pomocą pomiarów temperatury skóry palców rąk. W badaniach zastosowano dwa sposoby oziębienia rąk celem oceny wpływu temperatury wody i okresu chłodzenia na czas odnowy u osób o akrohomoiotermicznym typie regulacji obwodowej. MATERIAŁ I METODY W badaniach wykonano dwa testy czynnościowej próby termicznej. W jednym teście stosowano oziębianie obu rąk przez 10 minut w wodzie o temperaturze 14 °C (krajowe wytyczne), a w drugim odpowiednio oziębiano ręce przez 5 minut w wodzie o temperaturze 12 °C (norma ISO 14835-1:2004). W każdym teście uczestniczyło po 20 młodych (22-24 lata) i zdrowych osób. Temperaturę skóry mierzono na wszystkich palcach obu rąk przed i po oziębianiu. WYNIKI Średni czas odnowy w czynnościowej próbie termicznej nie różnił się statystycznie w grupie badanej wg zaleceń normy ISO 14835-1:2004 w porównaniu do grupy badanej wg wytycznych krajowych. WNIOSKI Parametry oziębiania stosowane w czynnościowej próbie termicznej nie mają istotnego wpływu na czas odnowy u osób z homoiotermicznym typem regulacji naczyń obwodowych.
Źródło:
Annales Academiae Medicae Silesiensis; 2009, 63, 5; 50-55
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Środowiskowa ocena ekspozycji dzieci na wolnozmienne pola magnetyczne w budynkach szkolnych z terenu Tychów, usytuowanych w pobliżu transformatorów energetycznych
Environmental exposure of primary school buildings located in Tychy to extremely low frequency magnetic fields from nearby transformers
Autorzy:
Zieliński, Grzegorz
Harazin, Barbara
Mroczek, Alina
Malinowska-Borowska, Jolanta
Szołtysik, Izabela
Powiązania:
https://bibliotekanauki.pl/articles/1038952.pdf
Data publikacji:
2012
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
wolnozmienne pole magnetyczne
szkoły
ekspozycja
transformatory
uczniowie
extremely low frequency magnetic fi elds
schools
exposition
transformer
pupils
Opis:
INTRODUCTION In city agglomerations, educational establishments are very often within the vicinity of energy infrastructure such as, power lines, distribution transformers; power distribution rooms, mobile phone base stations and overhead tramway power lines. The levels of magnetic fields in the classrooms of such educational establishments are not well known. MATERIAL AND METHODS Ten primary schools from Tychy were chosen for the study, all of which are located within a radius of 100 meters from distribution transformers. The magnetic induction was measured in at least two classrooms, i.e. in the information technology classroom and a humanistics classroom. RESULTS Based on visual inspection, it was ascertained that for two schools, the transformers were installed at a distance of not more than 20 m. In one school the distance is 15 m and in another there was an aerial voltage line at a distance of 20 m. The latter school contained elevators. In the humanistics classroom adjacent to the elevator shaft, an induction level of 110 nT was measured. In one of the three oldest schools tested, which was 125 years old, the measured magnetic induction levels were even higher: in the humanistic classroom – 226 nT and in the computer studies classroom – 59 nT. We also found that for 10 schools, the magnetic induction levels were higher in the information technology classroom than in the humanistics classroom. CONCLUSIONS Transformers installed within the vicinity of school buildings do not influence the magnetic induction levels within classrooms and school premises.
WSTĘP W aglomeracjach miejskich bardzo często placówki oświatowe zlokalizowane są w pobliżu infrastruktury energetycznej, takiej jak: przesyłowe linie energetyczne, stacje transformatorowe, rozdzielnie napięć, stacje bazowe telefonii komórkowej, sieci trakcji tramwajowej. Nie są znane poziomy pól magnetycznych w salach lekcyjnych tak usytuowanych budynków szkolnych. Celem podjętych badań była ocena poziomu indukcji magnetycznej w klasach i pracowniach budynków szkolnych usytuowanych w pobliżu stacji transformatorowo-rozdzielczych. MATERIAŁ I METODY Do badań wybrano 10 szkół podstawowych z terenu Tychów, w pobliżu których (w promieniu 100 metrów) zainstalowane były transformatory. Indukcję magnetyczną mierzono co najmniej w dwóch salach lekcyjnych (w pracowni informatycznej i pracowni do przedmiotów humanistycznych). WYNIKI Na podstawie przeprowadzonej wizji lokalnej stwierdzono, że tylko w dwóch szkołach transformatory energetyczne zainstalowane zostały w odległości nieprzekraczającej 20 m. W odległości 15 m od jednej ze szkół zainstalowany był transformator, a w odległości 20 m przebiegała napowietrzna linia elektryczna niskiego napięcia. W szkole tej, wewnątrz budynku, stwierdzono windę towarową. Zmierzony w sali humanistycznej sąsiadującej z tunelem windy poziom indukcji wynosił 110 nT. W jednej z trzech najstarszych badanych szkół (125-letniej) poziomy indukcji magnetycznej były jeszcze wyższe: w klasie humanistycznej 226 nT, a w pracowni informatycznej 59 nT. Wykazano ponadto, że w 6 spośród 10 zbadanych pracowni informatycznych poziomy indukcji magnetycznej były wyższe niż w klasach humanistycznych. WNIOSKI Transformatory zainstalowane w pobliżu budynków szkolnych nie miały wpływu na zmierzoną indukcję magnetyczną w klasach i pomieszczeniach szkolnych.
Źródło:
Annales Academiae Medicae Silesiensis; 2012, 66, 5; 54-61
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies