Tytuł:
Experimental investigation on a rotodynamic pump operating in the cogeneration system with a low-boiling working medium
Autorzy:
Kaczmarczyk, T.
Żywica, G.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/175328.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
organic rankine cycle
micro-CHP
rotodynamic peripheral pump
low-boiling medium
HFE7100
Opis:
The article presents the research carried out on the circulating rotodynamic pump (peripheral pump) operating in the organic Rankine cycle with or without regeneration. The low-boiling solvent HFE7100 was used as the working fluid. Its boiling point is around 61 ◦C at atmospheric pressure. An expansion valve, which simulated the operation of an expansion machine, was used to load the tested pump. The flow characteristics were given for the working media: a solution of glycol and HFE7100 in the condenser, thermal oil and HFE7100 in the evaporator and HFE7100 in the regenerator. The research results concerning the PK70 pump operating in an ORC cycle are reported for the HFE7100 temperature range 15-60 ◦C and the dynamic viscosity range of 0.132 to 0.66 mPas. The maximum flow rate and pressure of the pump during its operation in the ORC system were assessed. The analysis of the results demonstrates that the maximum efficiencies of the pump operating with or without regeneration were 44% and slightly below 37%, respectively. The impact of the selected physicochemical parameters of the working mediums on the pressure drops occurring in the ORC cogeneration installation was discussed. Based on the research conducted and the measurement results, the possibility to apply a PK70 unit as a circulating pump for the working medium in an ORC cycle was checked.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 134; 63-87
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Expanders for dispersed power generation: maintenance and diagnostics problems
Autorzy:
Żywica, G.
Kaczmarczyk, T.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/175441.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
expansion devices
expanders
turbines
ORC systems
cogeneration
Opis:
The article discusses the problems related to the operation of various types of expansion devices used in small cogeneration systems. Both volumetric and dynamic expanders were considered, including scroll, screw, vane, piston and turbine expanders. For each of these solutions, principles of operation were explained as well as major advantages and disadvantages. The results of experimental research on several expanders of various types were also presented. The overview of expanders included in this paper, along with basic operational problems and functional characteristics, is the collection of valuable information facilitating selection of a suitable expander for specific applications. This is particularly important in the context of search for new energy sources and opportunities to improve the energy efficiency of available energy resources.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 131; 173-188
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements and vibration analysis of a five-stage axial-flow microturbine operating in an ORC cycle
Pomiary i analiza poziomu drgań pięciostopniowej mikroturbiny osiowej pracującej w obiegu ORC
Autorzy:
Kaczmarczyk, T. Z.
Żywica, G.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/328882.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
five-stage axial-flow microturbine
distribution of vibration level
HFE7100
ORC
pięciostopniowa mikroturbina osiowa
rozkład poziomu drgań
Opis:
This paper presents results concerning the experimental investigation of a five-stage prototypical axial-flow microturbine operating in an ORC installation. The microturbine has an electrical capacity of 3 kW at the nominal rotational speed of 12000 rpm and is supplied with a low-boiling medium's vapour HFE7100. During the test, both the full vibration frequency distribution and the overall level of the velocity vibrations RMS in the microturbine were measured. A spectral analysis of vibration velocity was conducted during the grind-in process after a modernisation of the shrouding bandage of the microturbine set's flow system took place. The article presents the operational characteristics of the ORC system as well as the characteristics showing the electric power produced as the function of rotational speed of the microturbine. On the basis of the results obtained, there was assessed the dynamic performance of the microturbine and it was ranked according to ISO 10816-1 standard. The paper also shows the measurement results of the so-called kurtosis within the frequency range of 15 to 30 kHz, which made it possible to evaluate the dynamic state of the rolling bearings by which the microturbine rotor was supported.
W artykule przedstawiono wyniki badań poziomu drgań podczas rozbiegu prototypowej 5-stopniowej osiowej mikroturbiny pracującej w obiegu Rankine'a. Mikroturbina o nominalnej mocy 3 kW i prędkości obrotowej 12000 obr/min była zasilana parą czynnika niskowrzącego HFE7100. Podczas badań zmierzono rozkłady częstotliwościowe oraz ogólny poziom prędkości drgań Vrms mikroturbiny w zależności od prędkości obrotowej. Przedstawiono analizę prędkości drgań podczas docierania i po modernizacji bandaży układu przepływowego mikroturbozespołu. Zamieszczono charakterystyki pracy obiegu ORC oraz charakterystyki mocy elektrycznej w zależności od prędkości obrotowej mikroturbiny. Na podstawie uzyskanych wyników oceniono stan dynamiczny mikroturbiny oraz zaklasyfikowano badaną maszynę przepływową wg normy ISO 10816-1. W pracy zamieszczono wyniki pomiarów tzw. kurtozy w przedziale 15-30 kHz na podstawie której wykonano ocenę stanu łożysk tocznych układu wirującego mikroturbiny.
Źródło:
Diagnostyka; 2017, 18, 2; 51-58
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic investigation of the cogenerative ORC system with low-boiling medium
Badania termowizyjne układu kogeneracyjnego ORC z czynnikiem niskowrzącym
Autorzy:
Kaczmarczyk, T. Z.
Żywica, G.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/329692.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
organic Rankine cycle
low-boiling medium
thermographic
obieg organiczny Rankine’a
czynnik niskowrzący
termografia
Opis:
The paper presents the results of experimental investigations of the ORC system equipped with the expansion valve simulating microturbine operation. The aim of the research was to verify the correct functioning of the installation components and to access the technical condition of the thermal insulation in the heating and cooling mode with regard to the design assumptions. The research was conducted for different values of medium flow rates. The images were acquired using the thermal imaging camera FLIR E50, which is equipped with a specialized software. On the basis of the experimental results, the heat losses have been estimated, together with the places which were the major source of loss (the so-called thermal bridges). It was shown experimentally that the application of a thermal imaging camera can constitute a simple and fast thermal diagnostics method for installations of this type.
W pracy przedstawiono wyniki badań eksperymentalnych układu ORC z zaworem rozprężnym symulującym pracę mikroturbiny. Badania miały na celu sprawdzenie poprawności działania podzespołów instalacji oraz ocenę stanu technicznego izolacji termicznej podczas procesów grzania, chłodzenia i regeneracji w stosunku do założeń projektowych. Badania przeprowadzono dla wybranych natężeń przepływów mediów roboczych. W badaniach wykorzystano kamerę termowizyjną FLIR E50 wraz ze specjalistycznym oprogramowaniem. Na podstawie wyników badań oszacowano straty ciepła instalacji oraz określono miejsca, w których występowały największe straty (tzw. mostki termiczne). Wykazano, że zastosowanie kamery termowizyjnej może być szybką i prostą metodą diagnostyki termicznej tego typu instalacji energetycznych.
Źródło:
Diagnostyka; 2015, 16, 3; 25-32
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies