Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water treatment sludge" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Current stage of knowledge relating to the use ferruginous sludge from water treatment plants – a preliminary review of the literature
Autorzy:
Wołowiec, Magdalena
Bajda, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/127615.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mineralogiczne
Tematy:
water treatment residuals
reuse
water treatment
plant sludge management
Opis:
In water treatment plants, a large amount of wastewater and sludge is generated during the processing of drinking water. The composition of the sludge is determined by the type and raw water chemistry, as well as the methods and materials used for purification. The major components of the sludge are iron and manganese oxyhydroxides. In the past, the sludge was landfilled, but for environmental reasons it became necessary to find uses for the sludge. The aim of this study was to identify examples of using this sludge. Nowadays, the sludge is applied in the treatment of municipal wastewater, agriculture, and the production of cement and bricks, among others. Attention was also paid to the possibility of using the water processing sludge in different sorption applications.
Źródło:
Mineralogia; 2017, 48, 1/4; 39-45
1899-8291
1899-8526
Pojawia się w:
Mineralogia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of Alum Sludge from Surabaya Water Treatment Plant, Indonesia
Autorzy:
Barakwan, Rizkiy Amaliyah
Trihadiningrum, Yulinah
Bagastyo, Arseto Yekti
Powiązania:
https://bibliotekanauki.pl/articles/124534.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
aluminum sludge
characteristics
comparison
water treatment
Opis:
A conventional water treatment plant (WTP) typically involves coagulation-flocculation processes to remove suspended particles and colloids in raw water. The process generates a large volume of alum sludge with high aluminum content, which is discharged into a river with improper treatment. The sludge may cause a potential risk to human health, and disrupt the life of river biota. The aims of this study were to determine the physical and chemical characteristics of alum sludge from Surabaya WTP, and to compare them with those of alum sludge from other plants in Indonesia and developing countries. The alum sludge sample was obtained from the Surabaya WTP in Indonesia. The results showed that the alum sludge had a pH value of 7.47, volatile solids of 12,696 mg/L, total suspended solids of 12,511 mg/L, chemical oxygen demand (COD) 9666.7 mg/L, biochemical oxygen demand (BOD) 1082.5 mg/L, and sludge volume index 114.18 mL/g. The sludge had high aluminum and iron concentrations. The aluminum content of the sludge was 1194 mg/L, iron 515 mg/L, chromium 0.217 mg/L, and copper 0.559 mg/L. Having a BOD/COD ratio of 0.1, the alum sludge contained high level of nonbiodegradable organic matter.
Źródło:
Journal of Ecological Engineering; 2019, 20, 5; 7-13
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post-coagulation sludge management for water and wastewater treatment with focus on limiting its impact on the environment
Zagospodarowanie osadów po procesie koagulacji wody, celem ograniczenia ich wpływu na środowisko
Autorzy:
Łukasiewicz, Ewelina
Powiązania:
https://bibliotekanauki.pl/articles/434998.pdf
Data publikacji:
2016-12-15
Wydawca:
Uniwersytet Opolski
Tematy:
post-coagulation sludge
sludge management
water treatment
osad pokoagulacyjny
gospodarka osadowa
oczyszczanie wody
Opis:
Water treatment process produces great amount of sludge. According to growing interest in sustainable development and environment protection, sludge management problem should be taken into consideration. Accordingly, its recovery, recycling and reuse are optimal solutions for Water Treatment Sludge(WTS) management. The conventional Water Treatment Plants (WTP) produce even up to 100 000 ton/year of sludge. The coagulation process produces a huge amount of sludge. This contamination may be recovered and reused. Some amount of coagulants may be recovered and reused during the wastewater treatment process. The Water Treatment Sludge with e.g. iron or alum content, may be also used as a coagulant at a wastewater treatment plant. In the course of this paper, few methods for post-coagulation sludge management are presented.
Proces oczyszczania wody skutkuje powstaniem dużej ilości osadów. Polityka zrównoważonego rozwoju, wymaga bezpiecznych dla środowiska działań proekologicznych, związanych z gospodarką wodno-ściekową. Zgodnie z tym stosuje się metody odzysku, recyklingu oraz ponownego użycia w stosunku do osadów powstających podczas uzdatniania wody.Proces koagulacji wód powierzchniowych i podziemnych powoduje powstanie dużej ilości osadów. Konwencjonalna stacja uzdatniania wody może produkować nawet do 100000 ton osadu rocznie. W niniejszej pracy przedstawiono metody stosowane w gospodarce osadowej, takie jak między innymi odzysk koagulantów z osadów, użycie osadu jako koagulantu na stacjach uzdatniania oraz oczyszczalniach ścieków, zastosowanie osadów jako kompozytu w budownictwie, stabilizację tlenową osadu celem zmniejszenia jego ilości, poprzez redukcję materiału organicznego.
Źródło:
Economic and Environmental Studies; 2016, 16, 4(40); 831-841
1642-2597
2081-8319
Pojawia się w:
Economic and Environmental Studies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ recyrkulacji osadu pokoagulacyjnego na skuteczność oczyszczania wody o dużej intensywności barwy
Effect of coagulation sludge recirculation on the efficiency of water treatment in the case of high color intensity
Autorzy:
Gumińska, J.
Kłos, M.
Powiązania:
https://bibliotekanauki.pl/articles/237470.pdf
Data publikacji:
2008
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
koagulacja
osad pokoagulacyjny
recyrkulacja osadu
water treatment
coagulation
sludge recirculation
Opis:
Skuteczność procesu koagulacji decyduje w znacznym stopniu o skuteczności całego układu oczyszczania wody. W celu poprawy skuteczności oczyszczania wody, procesy koagulacji i sedymentacji mogą być realizowane w urządzeniach wielofunkcyjnych z zawieszonym osadem, w których stosuje się recyrkulację osadu pokoagulacyjnego. W pracy podjęto problem wpływu stopnia recyrkulacji osadu pokoagulacyjnego na wymaganą dawkę koagulantu oraz skuteczność oczyszczania wody modelowej o dużej intensywności barwy. W oparciu o uzyskane wyniki stwierdzono, że przy optymalnym stopniu recyrkulacji osadu pokoagulacyjnego możliwe jest znaczne zmniejszenie dawki koagulantu w stosunku do dawki w przypadku koagulacji klasycznej, tj bez recyrkulacji osadu. Stwierdzono, że nawet stosując nieco mniejszy od optymalnego stopień recyrkulacji możliwe było przy tej samej dawce koagulantu uzyskanie lepszej jakości wody oczyszczonej niż podczas typowej koagulacji. Jednocześnie wprowadzenie zbyt dużej ilości osadu pokoagulacyjnego prowadziło do pogorszenia skuteczności oczyszczania wody, nawet w stosunku do klasycznej koagulacji.
The efficiency of the coagulation process makes a remarkable contribution to the efficiency of the whole water treatment train. To enhance the efficiency of the water treatment process, it is advisable to conduct coagulation and sedimentation in a multifunctional system with a sludge blanket, where coagulation sludge can be made subject to recirculation. The study reported on in this paper focused on the problem of how the recirculation of the coagulation sludge affects the coagulant dose required and the efficiency of pollutant removal from model water characterized by a high colored matter content. The results have shown that with an optimal extent of sludge recirculation the coagulant dose can be noticeably reduced as compared to the one required in conventional coagulation, where sludge is not recirculated. It has also been found that even if the extent of recirculation slightly deviates from the optimal value, the quality of the treated water, obtained with the same coagulant dose, will be higher than when use is made of conventional coagulation. But if the quantity of recirculated coagulation sludge was excessively high, this was concomitant with a decrease in the efficiency of water treatment even in comparison to the classical coagulation process.
Źródło:
Ochrona Środowiska; 2008, 30, 1; 9-12
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odwadnianie osadów powstających w procesach oczyszczania wody powierzchniowej na przykładzie wodociągu Raba
Dewatering of the sludge produced in the course of surface water treatment: A case study
Autorzy:
Balcerzak, W.
Rybicki, S.M.
Kaszowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/237792.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
woda powierzchniowa
osad pokoagulacyjny
odwadnianie osadu
poletka osadowe
prasa taśmowa
water treatment
surface water
coagulation sludge
sludge dewatering
sludge drying beds
belt press
Opis:
Na przykładzie zakładu oczyszczania wody Raba w Dobczycach, zaopatrującego Kraków w wodę, przeanalizowano stan gospodarki osadami powstającymi w procesach oczyszczania wody powierzchniowej. Przeanalizowano wyniki badań nad składem oraz podatnością osadów na odwadnianie na poletkach. W badaniach uwzględniono sezonową zmienność jakości ujmowanej wody i jej wpływ na charakterystykę powstających osadów. W celu zintensyfikowania odwadniania osadów zaproponowano modernizację gospodarki osadowej w wodociągu Raba, polegającą na zastosowaniu pras taśmowych w miejsce poletek do odwadniania osadu. Wykazano, że podczas doboru urządzeń do odwadniania osadu należy zwrócić uwagę na dużą elastyczność projektowanego układu, konieczną z uwagi na znaczną zmienność masy osadu powstającego w urządzeniach do oczyszczania wody. Ważne jest także uwzględnienie większego - niż dotychczas przyjmowano - udziału suchej masy organicznej w całkowitej masie osadu.
The case in point is the Raba Water Treatment Plant of Dobczyce, which supplies water to the city of Cracow. The plant was chosen to exemplify the approach to the management of the sludge generated during surface water treatment in Polish water treatment plants. The study included analyses of sludge composition and the readiness of the sludge to dewatering in drying beds. Consideration was given to the seasonal variations in the quality of the taken-in water, with emphasis on their contribution to the characteristics of the sludge produced. In order to enhance the extent of sludge dewatering, a rationalization of the sludge management at the plant has been proposed, which consists in the replacement of the sludge drying beds with belt presses. When choosing the devices for sludge dewatering, it is essential to attach importance to the flexibility of the system being designed, because of the remarkable variations in the mass of the sludge which forms in particular units of the water treatment lines. It is also of importance to take into account that the content of organic substances in the overall mass of the sludge is higher than the one assumed so far.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 3, 3; 65-68
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metale ciężkie w osadach powstających przy uzdatnianiu wody
Heavy metals in post-coagulation sludge from water treatment
Autorzy:
Płonka, I.
Pieczykolan, B.
Amalio-Kosel, M.
Loska, K.
Powiązania:
https://bibliotekanauki.pl/articles/126867.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
metale ciężkie
osady pokoagulacyjne
oczyszczanie wody
heavy metals
post-coagulation sludge
water treatment
Opis:
Głównym źródłem zaopatrywania w wodę przeznaczoną do spożycia są wody powierzchniowe. Szacuje się, że w Polsce ok. 50% wody jest pobierane z ujęć powierzchniowych, tj. rzek, jezior i zbiorników zaporowych, z czego ok. 15% stanowią wody infiltracyjne. Aby woda mogła trafić do odbiorców, musi zostać poddana odpowiednim procesom oczyszczania. Do najczęściej stosowanych jednostkowych procesów oczyszczania wody powierzchniowej należą koagulacja i filtracja. Z tego względu w zakładach uzdatniania wody powstają głównie osady pokoagulacyjne. Osady te zawierają wszystkie zanieczyszczenia usuwane z wody surowej pobieranej do oczyszczania, w tym również metale ciężkie. W pracy przedstawiono wyniki badań zawartości metali ciężkich w osadach pokoagulacyjnych powstających w dwóch zakładach uzdatniania wody: Zakładzie Produkcji Wody I (ZPW I) i Zakładzie Produkcji Wody II (ZPW II). Zakłady te różnią się stosowaną technologią oczyszczania wody oraz charakterem zbiorników wody powierzchniowej. Osady do badań pobierano w ciągu całego roku w celu określenia wpływu zmian jakości wody surowej na zawartość metali ciężkich w osadach. Oznaczenie zawartości metali ciężkich: niklu, miedzi, chromu, cynku, kadmu, ołowiu i rtęci wykonano dla zmineralizowanych próbek metodą AAS.
The main sources of water supply for human consumption are the surface water. It is estimated that in Poland about 50% of water is collected from surface water intakes, rivers, lakes and reservoirs, of which about 15% are water infiltration. Raw water must be subjected to appropriate treatment processes before it is directed to human consumption. The most commonly treatment processes used of surface water are coagulation and filtration. Therefore, water treatment plants are precipitated post-coagulation sludge. This post-coagulation sludge contains all the pollution which is removed from treated raw water, including heavy metals. The paper presents the results of researches of contents heavy metals in post-coagulation sludge collected from two water treatment plants: Water Treatment Plant I (WTP I) and Water Treatment Plant II (WTP II). These plants differ in used water treatment technology and the nature of surface water reservoirs. Post-coagulation sludge were taken throughout the year to determine the impact of raw water quality changes on the content of heavy metals in the sludge. Determination of heavy metals: nickel, copper, chromium, zinc, cadmium, lead, mercury was made for the mineralized samples by AAS method.
Źródło:
Proceedings of ECOpole; 2012, 6, 1; 337-342
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary study of hot mix asphalt containing water treatment and sewage sludge
Autorzy:
Bastidas-Martínez, J. G.
Camapum de Carvalho, J.
Lucena, L. C.
Farias, M. M.
Rondón-Quintana, H. A.
Powiązania:
https://bibliotekanauki.pl/articles/230585.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
osad
uzdatnianie wody
osad ściekowy
wypełniacz mineralny
mieszanka asfaltowa gorąca
water treatment
sludge
sewage sludge
mineral filler
hot mix asphalt
Opis:
Throughout the world, considerable quantities of water treatment sludge (WTS) and sewage sludge (SS) are produced as waste. This study assessed in the laboratory, the possibility to use both waste products when they are incorporated as filler at 1% with relation to the total mass of a hot mix asphalt - HMA. To this end, both waste products were initially reduced to ash through a calcination process. Resistance tests under monotonic load (Marshall and indirect tension tests), and cyclic load (resilient modulus test) were applied on mixes that contained WTS and SS. Besides, moisture damage (modified Lotmman test), and abrasion (Cantabro) resistance were assessed. An analysis of variance (ANOVA) test was performed in order to verify if the results are statically equal or not to those of the control HMA. As a general conclusion, it is reported that both materials show a resistance increase under monotonic load and higher stiffness under cyclic load (cohesion) when they are incorporated into the mix as filler despite the fact that the asphalt content used was less than the control mix. However, some problems are observed associated with moisture damage resistance, and friction wear (adherence).
Źródło:
Archives of Civil Engineering; 2020, 66, 1; 225-240
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the most effective operating conditions of membrane bioreactor used to industrial wastewater treatment
Autorzy:
Świerczyńska, A.
Bohdziewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/208164.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wastewater treatment
activated sludge process
bioconversion
bioreactors
industrial water treatment
landfill
leachate treatment
water treatment
activated sludge
dairy wastewater
industrial wastewater treatment
membrane bioreactor
municipal landfills
oczyszczalnia ścieków
proces osadu czynnego
biokonwersja
bioreaktory
uzdatnianie wody przemysłowej
uzdatnianie wody
osad czynny
ścieki mleczarskie
oczyszczanie ścieków przemysłowych
bioreaktor membranowy
składowiska odpadów komunalnych
Opis:
The effectiveness of co-treatment of leachates from an old site of municipal landfill with a dairy industry wastewater in a membrane bioreactor has been investigated. The subjects of the study were leachates collected at the municipal landfill in Tychy and dairy wastewaters from Dairy Plant in Bieruń. The determination of the most effective technological parameters of the process, i.e. activated sludge load and its concentration and types of COD fractions in the reactor influent was made. It was shown that the activated sludge load at the level of 0.06 g COD/(gDM·d) was the highest permissible one among all the investigated loads and the process run effectively within the whole investigated range of concentrations of activated sludge in a bioreactor. It was found that in the treated wastewater, the fraction of easily degradable organic compounds was the dominant one.
Źródło:
Environment Protection Engineering; 2015, 41, 1; 41-51
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potato waste treatment by microbial fuel cell. Evaluation based on electricity generation, organic matter removal and microbial structure
Autorzy:
Du, H.
Li, F.
Huang, K.
Li, W.
Feng, C.
Powiązania:
https://bibliotekanauki.pl/articles/206898.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water treatment
performance
technology
bacterial
recovery
sludge
carbon
microbial fuel cell
COD
potato waste
uzdatnianie wody
ChZT
węgiel
odpady ziemniaczane
Opis:
The performance of microbial fuel cell (MFC) in treating potato waste was evaluated using a two-chamber MFC supplied with potato liquid after mastication of market available fresh potato. Evaluation was conducted based on electricity generation, organic matter removal (CODCr, DOC and volatile fatty acids (VFAs)), and microbial structure on the anode and in the anodic solution of the reactor. Current density exhibited a trend that followed the concentration changes of organic matter in the solution, with its highest value being observed as 208 mA/m2. Effective removal of organic matter was also observed. By the end of the experiment, the removal for total COD reached about 84%. Bacterial structure analysis based on PCR, DGGE and sequencing indicated that more species were developed in the anodic solution than on the anode, with Proteobacteria, Firmicutes and Bacteroides being dominant. Geobacter, a well reported exoelectrogenic species, was found more predominant on the anode than in the anodic solution. The results thus indicated that simultaneous stabilization and electricity generation could be achieved when potato waste is treated in MFC.
Źródło:
Environment Protection Engineering; 2017, 43, 1; 5-18
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu pylistego węgla aktywnego na właściwości sedymentacyjne i adsorpcyjne osadu pokoagulacyjnego
Effect of powdered activated carbon on the settleability and adsorptive properties of coagulation sludge
Autorzy:
Szlachta, M.
Adamski, W.
Powiązania:
https://bibliotekanauki.pl/articles/236464.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
koagulacja
sedymentacja
osad pokoagulacyjny
węgiel aktywny
węgiel pylisty
water treatment
coagulation
adsorption
sedimentation
coagulation sludge
activated carbon
powdered carbon
Opis:
Przeprowadzono badania wpływu pylistego węgla aktywnego stosowanego podczas koagulacji objętościowej na właściwości sedymentacyjne i adsorpcyjne osadu pokoagulacyjnego. Określono ilość zsedymentowanych zawiesin kłaczkowatych w zależności od dawki pylistego węgla aktywnego, a także zdolność adsorpcyjną osadu powstałego w procesie koagulacji i koagulacji wspomaganej PWA w stosunku do rozpuszczonych substancji organicznych w wodzie naturalnej. Wykazano, że wspomaganie koagulacji pylistym węglem aktywnym w istotny sposób przyczyniło się do poprawy właściwości sedymentacyjnych zawiesin pokoagulacyjnych, co pozwoliło na osiągnięcie porównywalnej skuteczności w czasie krótszym o około 50÷75% niż przyjęty w badaniach dwugodzinny czas sedymentacji. Analiza kinetyki sedymentacji PWA wykazała, że po 2 h sedymentacji w wodzie pozostało średnio około 18% adsorbentu. Z tego względu w optymalizacji procesu koagulacji wspomaganej PWA szczególną uwagę należy poświęcić właściwemu doborowi kolejności dawkowania koagulantu i adsorbentu w celu zmniejszenia ryzyka przechodzenia ziaren PWA do oczyszczonej wody. Osad powstały w procesach koagulacji oraz koagulacji-adsorpcji z udziałem PWA miał zdolność do adsorbowania rozpuszczonych substancji organicznych (mierzonych jako RWO i absorbancja w UV) z oczyszczonej wody. Jednakże wydajność adsorpcji na osadzie pokoagulacyjnym była niewielka w porównaniu z osadem powstałym w procesie koagulacji-adsorpcji z udziałem PWA.
The paper addresses the problem of how the powdered activated carbon (PAC) applied during coagulation affects the settling and adsorptive properties of coagulation sludge. The quantity of the settled flocs was related to the PAC dose used, whereas the adsorptive capacity of the sludge produced in the processes of coagulation and PAC-aided coagulation was determined in relation to the dissolved organic substances (expressed as DOC and UV absorbance) that were present in natural water. PAC-aided coagulation was found to substantially improve the settling properties of the coagulation sludge, thus making it possible to achieve a comparable efficiency in a time by approx. 50 to 75% shorter than the time of two hours adopted for sedimentation in our study. Kinetic analysis of PAC sedimentation has revealed that after 2 hours of the process approx. 18% of the adsorbent persisted in the water on average. For this reason it is recommended that during optimation of the PAC-aided coagulation process particular consideration should be given to the sequence in which the coagulant and adsorbent are dosed, in order to reduce the risk that the PAC grains will penetrate into the treated water. The sludge produced in the processes of coagulation and coagulation-PAC adsorption displayed a capacity to adsorb dissolved organic substances from the treated water. The efficiency of adsorption onto the coagulation sludge, however, was poor as compared to the sludge produced during the process where coagulation was combined with PAC adsorption.
Źródło:
Ochrona Środowiska; 2009, 31, 1; 37-40
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania mozliwosci biologicznego wykorzystania osadow pokoagulacyjnych Zakladow Uzdatniania Wody, zasobnych w glin
Studies on the possibilities of biological utylization of coagulation sludges enriched in aluminium, from the Water Cleaning Company
Autorzy:
Szerszen, L
Chodak, T.
Karczewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/874790.pdf
Data publikacji:
1993
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
ochrona srodowiska
wykorzystanie sciekow
uzdatnianie wody
osady pokoagulacyjne
glin
konferencje
woda
Warszawa konferencja
environment protection
sewage utilization
water treatment
post-coagulation sludge
aluminium
conference
water
Warsaw conference
Źródło:
Roczniki Państwowego Zakładu Higieny; 1993, 44, 1; 105-112
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Environmental contaminants of emerging concern: occurrence and remediation
Autorzy:
Prasad, Majeti Narasimha Vara
Elchuri, Sailaja V.
Powiązania:
https://bibliotekanauki.pl/articles/31342696.pdf
Data publikacji:
2023
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
contaminants of emerging concern
CECs
health hazards
chemical waste
disposal
sludge treatment
water treatment
bioremediation
engineered organisms
zagrożenie zdrowotne
odpady chemiczne
usuwanie odpadów
osad ściekowy
oczyszczanie wody
bioremediacja
organizmy inżynieryjne
Opis:
Certain contaminants are termed as emerging (Contaminants of Emerging Concern, CEC) since all aspects of these pollutants are not known and their regulation is not ununiform across the nations. The CECs include many classes of compounds that are used in various industries, plant protection chemicals, personal care products and medicines. They accumulate in waterbodies, soils, organisms including humans. They cause deleterious effects on plant animal and human health. Therefore, alternative greener synthesis of these chemicals, sustainable economic methods of waste disposal, scaling up and circular methods using sludge for removing the contaminants are innovative methods that are pursued. There are several improvements in chemical waste treatments using electro-oxidation coupled with solar energy, high performing recycled granular activated charcoal derived from biomass are few advances in the field. Similarly, use of enzymes from microbes for waste removals is a widely used technique for bioremediation. The organisms are genetically engineered to remove hazardous chemicals, dyes, and metals. Novel technologies for mining economically the precious and rare earth elements from e-waste can improve circular economy. However, there is additional need for participation of various nations in working towards greener Earth. There should be pollution awareness in local communities that can work along with Government legislations.
Źródło:
Chemistry-Didactics-Ecology-Metrology; 2023, 28, 1-2; 57-77
2084-4506
Pojawia się w:
Chemistry-Didactics-Ecology-Metrology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Post-coagulation sludge as an adsorbent of dyes from aqueous solutions
Osad pokoagulacyjny jako adsorbent barwników z roztworów wodnych
Autorzy:
Pieczykolan, B.
Płonka, I.
Powiązania:
https://bibliotekanauki.pl/articles/127092.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
water treatment
coagulation
post-coagulation sludge
dyes
waste sorbent
sorption process
sorption isotherm
uzdatnianie wody
koagulacja
osad pokoagulacyjny
barwnik
proces sorpcji
sorbenty odpadowe
izoterma sorpcji
Opis:
Water taken from the environment, before it is directed to recipients as drinking water, must be purified via different processes. From the water, inter alia, suspensions, organic compounds, colloidal particles as well as bacteria and viruses must be removed. The main source of usable water supply is surface water. The most frequently used methods of surface water treatment are coagulation and filtration processes. During these processes post-coagulation sludge is generated, which is the main waste produced in water treatment plants. This sludge is characterized by an amorphous structure with a strongly developed specific surface, similar to sewage sludge. In addition, it has a high content of organic compounds. In recent years, attempts have been made to transform sewage sludge from municipal wastewater treatment plants into waste sorbents. Taking into account some similarity between sewage sludge and post-coagulation sludge, an attempt was made to apply post-coagulation sludge as sorbent of dyes from aqueous solutions. Dried and crushed post-coagulation sludge was used in the studies. The most favourable pH of process and contact time as well as sorption isotherm were established. Moreover, based on the different isotherm two-parameter models, the sorption capacity, type of sorption and energy of sorption were calculated.
Woda pitna, zanim zostanie skierowana do odbiorców, musi zostać poddana procesom oczyszczania. Z wody muszą zostać usunięte między innymi zawiesiny, substancja organiczna, cząstki koloidalne oraz bakterie i wirusy. Głównym źródłem zaopatrywania w wodę użytkową są wody powierzchniowe. Najczęściej stosowanymi metodami uzdatniania wody powierzchniowej są metody koagulacji i filtracji. W trakcie tych procesów powstają osady pokoagulacyjne, które są głównymi odpadami powstającymi w zakładach uzdatniania wody. Osady te charakteryzują się strukturą amorficzną o mocno rozbudowanej powierzchni właściwej, podobnie jak osady ściekowe. Ponadto posiadają dużą zawartość związków organicznych. W ostatnich latach podjęto próby przeróbki osadów ściekowych pochodzących z komunalnych oczyszczalni ścieków w celu uzyskania odpadowych sorbentów. Uwzględniając pewne podobieństwo pomiędzy osadami ściekowymi, jak również pokoagulacyjnymi podjęto próbę wykorzystania osadów pokoagulacyjnych jako sorbentów barwników z roztworów wodnych. W trakcie badań wykorzystano wysuszone i rozdrobnione osady pokoagulacyjne. Wyznaczono najkorzystniejsze parametry procesu sorpcji statycznej (pH i czas kontaktu), jak również izotermę adsorpcji. Ponadto wykorzystując różne modele dwuparametryczne, wyznaczono maksymalną pojemność sorpcyjną, typ adsorpcji oraz energię adsorpcji.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 315-323
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ recyrkulacji osadu pokoagulacyjnego na skuteczność oczyszczania wody w procesie koagulacji
Effect of post-coagulation sludge recirculation on the efficiency of water treatment involving coagulation
Autorzy:
Gumińska, J.
Powiązania:
https://bibliotekanauki.pl/articles/236933.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
koagulacja wymiatająca
osad pokoagulacyjny
recyrkulacja
koagulant wstępnie zhydrolizowany
analizator prądu strumieniowego
water treatment
sweep coagulation
post-coagulation sludge
recirculation
pre-hydrolyzed coagulant
stream current analyzer
Opis:
W badaniach pilotowych wykazano, że wprowadzenie recyrkulacji osadu pokoagulacyjnego do układu koagulacji klasycznej poprawiło skuteczność procesu sedymentacji, zwłaszcza w zakresie usuwania drobnych cząstek zawiesin (ok. 1 žm). Określenie właściwego stopnia recyrkulacji pozwoliło na znaczne zmniejszenie liczby niezaglomerowanych cząstek zawiesin w wodzie odpływającej z osadnika, przy maksymalizacji stopnia usunięcia związków organicznych z wody. Nie zaobserwowano natomiast wpływu stopnia recyrkulacji na skuteczność usuwania rozpuszczonych związków organicznych z wody. Niezależnie od tego, czy proces oczyszczania prowadzono z zastosowaniem układu recyrkulacji, czy też bez niego, zmniejszenie absorbancji w nadfiolecie (254 nm) w przypadku próbek sączonych mieściło się w zakresie 55÷60%. W przypadku gdy proces oczyszczania wody prowadzi się zgodnie z mechanizmem koagulacji wymiatającej, sterowanie stopniem recyrkulacji powinno być uzależnione od liczby cząstek w wodzie odpływającej z osadnika i realizowane na zasadzie sprzężenia zwrotnego minimalizującego ich liczbę. W celu właściwej oceny skuteczności procesu koagulacji należy - oprócz kontroli mętności wody - prowadzić pomiar liczby cząstek w wodzie po sedymentacji.
Pilot tests have produced the following findings. The inclusion of recirculation of post-coagulation sludge into the conventional coagulation system improved the efficiency of the sedimentation process, especially with respect to suspended fine particle (~1 žm) removal. Determination of the desired extent of recirculation made it possible to significantly reduce the number of non-agglomerated suspended particles in the effluent from the settling tank and, at the same time, maximize the efficiency of organic matter removal from the water being treated. No effect was observed of the extent of recirculation on the efficiency of dissolved organic matter removal from the water. Regardless of whether the treatment process was conducted with or without recirculation, the reduction in UV absorbance (254 nm) in the case of filtered samples averaged between 55% and 60%. When the water treatment process follows the mechanism of sweep coagulation, the extent of recirculation will require control based not only on the number of particles in the effluent from the settling tank, but also on the feedback principle minimizing their number. To reliably assess the efficiency of the coagulation process, it is necessary to measure the number of particles in the water after sedimentation - in addition to water turbidity control.
Źródło:
Ochrona Środowiska; 2012, 34, 3; 19-32
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies