Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Silniki" wg kryterium: Temat


Tytuł:
Silniki przewietrzane o wzniosach H=200-355 mm (37-400 kW) tańsze, ale nie gorsze od silników zamkniętych
Ventilated ODP motors shaftheights 200 through 355 mm, an economical alternative to totally enclosed ones
Autorzy:
Bernatt, M.
Powiązania:
https://bibliotekanauki.pl/articles/1374889.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki przewietrzane
silniki zamknięte
silniki elektryczne
Opis:
Design and operating properties of ventilated (open drip proof) induction squirrel cage integral HP motors compared to totally enclosed fan cooled (TEFC) ones. In Europe TEFC motors are regarded as more reliable and better withstanding any environmental hazards. In US the approach to ODP motors is different, ODP motors are regarded as standard. In Poland manufacturing of ODP integral HP motors was abandoned in the 60-70 of the last century. Actually a new series of ventilated ODP motors of shaftheights 200-355 mm have been designed by KOMEL Centre. The motors, IEC degree of protection IP23, will be manufactured by two polish companies. Main features of the new motors incl. test results of 315 kW motor are presented.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 71; 7-10
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Trzy modele silnika skokowego hybrydowego
Three models of hybrid stepping motor
Autorzy:
Pochanke, A.
Wierciak, J.
Powiązania:
https://bibliotekanauki.pl/articles/159233.pdf
Data publikacji:
2003
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
silniki elektryczne
silniki skokowe
Opis:
W pracy podjęto porównanie funkcjonalnego działania trzech modeli silnika skokowego z punktu widzenia występowania i oddziaływania tłumienia elektromagnetycznego. Porównanie przeprowadzono na przykładzie silnika skokowego hybrydowego reprezentowanego kolejno przez model ruchu obrotowego o wymuszeniu dyskretnym, model elektromagnetyczny oraz model ruchu obrotowego z uwzględnieniem tłumienia elektromagnetycznego.
Stepping motors are electromechanical devices which convert electrical pulses into discrete mechanical movements. The shaft of a stepping motor rotates in discrete step increments when electrical command pulses are applied to it in the proper sequence. The speed of the motor shafts rotation is directly related to the frequency of the input pulses and the length of rotation is directly related to the number of input pulses applied. The value of the frequency of the input pulses does not depend on the shaft position, so stepping motors use open-loop control. It is very important to use correct mathematical model for computer simulation during simulation investigation of the electrical drive with stepping motor. The simplest mathematical model of the stepping motor is a model of discrete mechanical movement. But it does not take into consideration the electromagnetic damping produced by induced voltage. It is possible to use the full electromagnetic model of a stepping motor, but it is often very difficult. Particularly difficult is modelling of the winding band. Authors show that it is possible to use the simple mathematical model of discrete mechanical movement which takes into consideration the electromagnetic damping without necessity of modelling of the winding band.
Źródło:
Prace Instytutu Elektrotechniki; 2003, 216; 143-153
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of transverse branch parameters of capacitor dc brushless motor on its operational properties
Wpływ parametrów gałęzi poprzecznej kondensatorowego silnika bezszczotkowego prądu stałego na jego właściwości ruchowe
Autorzy:
Glinka, T.
Fręchowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/158910.pdf
Data publikacji:
2004
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
silniki elektryczne
silniki bezszczotkowe
Opis:
Work conducted at the Silesian University of Technology on the drive systems of brushless motors which could be operated at speeds higher than the basic speed led to creation of a new design, which was called the capacitor type, brushless, dc motor. This design is characterised by a not complicated scheme of connections and simple control system (Fig.1). The stator winding is made as a divided three-phase one and capacitors connected in delta are connected between the common points of coils of each phase of the winding. When loaded by a not high torque, the motor rotates with a speed near the double basic speed. At the instants when the inverter transistors are being commutated, the capacitors are recharged by current pulses. The pulses, flowing through half of the two armature phases produce a pulse type drive torque which accelerates the rotating masses. Increase in load decreases the rotating speed and causes that the current pulses flowing through the phase halves become higher and higher and produce higher and higher torque. When the rotor slows down to a speed lower than the basic one, the current begins to flow through the whole winding. From that instant the motor begins to behave like a classical brushless dc motor. Figure 2 shows the mechanical characteristic of the presented drive system supplied by a PWM wave shape with the filling factor near unity. Mechanical characteristics of the same motor are shown in the same diagram, when it operates in the classical system with full winding and with a half of the rotor coils. It can be seen that with changing load the characteristic of the drive approaches the one or the other characteristic of the motor operating in the classical system. The paper also discusses the effect of changes in capacitance and resistance of the transversal branch on the operation properties of the whole drive system (Figs.5, 6, 7). Increased capacitance of the capacitors used causes the rotational speed to be increased in the range of medium loads but at the same time the input motor current rises. The capacitance of the capacitors, if selected properly, permits easy speed control, without exceeding the maximum motor current. Increased resistance in the transversal branch decreases the value of the current pulses which recharge the capacitors and by doing this decreases the motor rotation speed in the range of medium loads.
Prace prowadzone na Politechnice Śląskiej nad układami napędowymi silników bezszczotkowych, które mogłyby pracować przy prędkościach większych niż prędkość bazowa, doprowadziły do powstania nowej konstrukcji, która została nazwana kondensatorowym, bezszczotkowym silnikiem prądu stałego. Konstrukcja ta charakteryzuje się nieskomplikowanym układem połączeń i prostotą układu sterowania (rys.1). Uzwojenie stojana wykonane jest jako trójpasmowe, dzielone, a między punkty wspólne cewek każdego z pasm uzwojenia są włączone kondensatory połączone w układ trójkąta. Przy obciążeniu niewielkim momentem, silnik wiruje z prędkością zbliżoną do podwójnej prędkości bazowej. W momentach komutacji tranzystorów falownika kondensatory przeładowywane są impulsami prądów. Impulsy przepływając przez połowę dwóch pasm twornika, wytwarzają impulsowy moment napędowy rozpędzający masy wirujące. Powiększanie obciążenia zmniejsza prędkość wirowania i powoduje, że impulsy prądowe przepływające przez połówki pasm są co-raz większe i wytwarzają coraz większy moment. Kiedy wirnik zwolni do prędkości niższej niż prędkość bazowa, prąd zaczyna płynąć przez całe uzwojenie. Od tej chwili silnik zaczyna zachowywać się jak klasyczny bezszczotkowy silnik prądu stałego. Na rysunku 2 pokazano charakterystykę mechaniczną prezentowanego układu napędowego przy zasilaniu falą PWM o współczynniku wypełnienia zbliżonym do jedności. Na tym samym wykresie naniesiono charakterystyki mechaniczne tego samego silnika, pracującego w układzie klasycznym, przy pełnym uzwojeniu i przy połowie zwojów twornika. Widać, że wraz ze zmianą obciążenia, charakterystyka napędu zbliża się do jednej lub drugiej charakterystyki silnika pracującego w układzie klasycznym. Ponadto w referacie omówiono wpływ zmian pojemności i rezystancji gałęzi poprzecznej na własności ruchowe całego układu napędowego (rys.5, 6, 7). Powiększanie pojemności zastosowanych kondensatorów powoduje zwiększenie prędkości obrotowej w zakresie średnich obciążeń, ale równocześnie wzrasta prąd pobierany przez silnik. Właściwie dobrana pojemność kondensatorów umożliwia wygodną regulację prędkości, bez przekroczenia prądu maksymalnego silnika. Wzrost rezystancji gałęzi poprzecznej zmniejsza wartość impulsów prądowych przeładowujących kondensatory, a tym samym zmniejsza prędkość wirowania silnika w zakresie średnich obciążeń.
Źródło:
Prace Instytutu Elektrotechniki; 2004, 220; 89-99
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie kosztów cyklu zużycia standardowych i energooszczędnych silników indukcyjnych niskiego napięcia przy pracy z różnym obciążeniem
The life cycle cost of standard and energy-efficient low-voltage induction motors at different load
Autorzy:
Zieliński, T.
Bernatt, M.
Powiązania:
https://bibliotekanauki.pl/articles/2076285.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
cykl życia
silniki elektryczne
silniki indukcyjne
silniki niskiego napięcia
energooszczędność
Opis:
The paper brings up the problems of low-voltage induction motor use. General use and large number of installations have the impact on significant electric energy consumption caused by these devices. A lot of working induction motors have been exploited for twenty years or more. They were repaired many times. This decreased their efficiency and makes large potential for electricity savings. Implementation of energy efficient motors may be the solution of the problem. Unfortunately, the barrier is the higher price of the energy saving motor than of the standard one. Investors are accustomed to the installation of low-efficient and cheap equipment or the repair of obsolete devices. Authors proposed the method of costs calculation in the whole life cycle of the devices (LCC analysis) as key method for making the decision about the purchase. The profitability of the energy efficient motor use and standard motor use was shown as the difference in the life cycle costs of those devices. Moreover, the cost of the standard motor repair and cost of the exchange of standard motor on energy efficient one were compared.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 73; 15-22
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ szerokości otwarcia żłobków na parametry eksploatacyjne silnika indukcyjnego małej mocy
Influence of slots width opening on the operating parameters of a small power induction motor
Autorzy:
Antal, L.
Antal, M.
Zawilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/2076289.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki indukcyjne
silniki elektryczne
stojan
wirnik
Opis:
The work presents calculation results of a small (1.5 kW) squirrel cage induction motor. The influence of slots width opening on efficiency and other operating characteristics of the motor was examined. The efficiency calculations were realized by finding distribution of time-harmonic magnetic field in a two-dimensional field-circuit motor model. Calculations for different combination of stator and rotor slot width openings showed influence of these geometric parameters on shape of magnetic field in motor air-gap. Field harmonic analysis shows that there is a possibility to decrease slot harmonics and in consequence, increase motor efficiency and other parameters.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 73; 125-130
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Doświadczenia eksploatacyjne z silnikiem synchronicznym
Experience in exploitation of synchronous motor
Autorzy:
Rasz, Z.
Polak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1374815.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki elektryczne
silniki synchroniczne
eksploatacja silnika elektrycznego
Opis:
The article presents authors' experience with exploitation of synchronous motor. The motor is a part of Ward-Leonard system. Since mounting in 1970, the motor has been still in use. It was a main construction of electrical machines for industrial use that time.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 71; 55-58
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synchronizacja silników synchronicznych przez sterowanie prądem wzbudzenia
Synchronization process of synchronous motors - control of excitation current value
Autorzy:
Zalas, P.
Zawilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/2076293.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki synchroniczne
synchronizacja
silniki elektryczne
model polowo-obwodowy
Opis:
The work presents calculation results of synchronization process of a two-speed, silent-pole, high power synchronous motor. The calculations were based on the examined two-dimensional, field-circuit model for the high power motor, type GAe 1716/20p with switchable configuration connection of armature winding and field magnet. The motor characteristics make it suitable for drives of fan - type machines. The work presents description of computable model and general parameters of analyzed two-speed motor. The influence of the synchronization moment on stator currents, electromagnetic torque and shaft velocity, during synchronization process with nominal excitation voltage and high value of load torque, was examined. The influence of the excitation voltage value greater than nominal, during synchronization process with high value of load torque, on stator currents, electromagnetic torque and shaft velocity was analyzed. The influence of the method control of excitation current, during synchronization process witch high value of load torque was also investigated. Dynamic diagrams of stator currents, excitation current, excitation voltage, electromagnetic torque and shaft velocity during synchronization process as results of computer simulation are presented.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 73; 143-148
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zespoły napędowe bezzałogowych statków powietrznych
Autorzy:
Sabak, R.
Powiązania:
https://bibliotekanauki.pl/articles/212935.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Lotnictwa
Tematy:
napędy BSP
spalinowe silniki tłokowe i turbinowe
silniki elektryczne
Opis:
W artykule przedstawiono problematykę wyboru rodzaju napędu do BSP o wyraźnie określonych zadaniach wojskowych. Z nich wynikają bowiem osiągi lotne jak prędkość i wysokość lotu oraz zakres czasowy ich osiągania, utrudnienia rozpoznania BSP wzrokowego, radarowego czy dźwiękowego, a także – udźwig i długotrwałość lotu.
Źródło:
Prace Instytutu Lotnictwa; 2011, 4 (213); 185-188
0509-6669
2300-5408
Pojawia się w:
Prace Instytutu Lotnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Napędy elektryczne wielobiegowe
Multi-speed electric drives
Autorzy:
Glinka, T.
Jakubiec, M.
Powiązania:
https://bibliotekanauki.pl/articles/1374875.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
napęd elektryczny
napęd wielobiegowy
silniki elektryczne
silniki wielobiegowe
energooszczędność
Opis:
Multi-speed electric drives are usually used in these cases, where work cycle of a given drive requires two or more different rotational speeds. Examples of such drives are pumps, fans, centrifuges, lifts etc. Another reason for using multi-speed drives is decreasing the energy consumption. Low energy consumption is ecological and economical criterion of the drive. If energy is not spent unnecessarily, then it need not be generated. About 98 of electrical energy in Poland is produced by burning coal and therefore, if less coal is burnt, the emission of carbon dioxide, sulphur dioxide and nitrogen oxides goes down. Lower speed of the drive causes diminished wear of driven mechanical devices and decreases generated noise; a good instance of such drive is belt conveyor. Energy-saving drive is the type of drive drawing minimum energy from the network necessary from the viewpoint of the engineering process - Fig.1. Energy required for engineering process during time t (e.g. day, month, year) is equal to. The driven mechanical system imposes load torque T(ob) and angular speed omega(m) on the motor. Equation (1) shows that the minimum energy consumption is achieved, when the drive operates at minimum allowable angular speed (omega (m min)). Usually the load torque is also minimum under such conditions. This type of working cycle algorithm in modern electric drives can be obtained by using cage induction motor supplied from power electronics converter (inverter). If we assume that, for a chosen drive, e.g. belt conveyor, the energy consumption per time unit (e.g. t = 24 h): - is equal to 100 per cent, when angular speed is kept constant (omega(m) = const) - drops down to 50 per cent in accordance with omega(m min) criterion (for a belt conveyor this speed corresponds to 100 per cent loading of the belt), then when two-speed drive is used, the energy consumption will go down to c. 70 percent, and with three-speed drive to c. 60 per cent. Two-or three-speed drive is cheaper and as easy to design as one-speed drive. Multi-speed drives can utilize the following motors: - multi-speed cage induction motors, - system of two induction slip-ring motors, supplied either individually or as a cascade system, - synchronous motors of special design, stator winding with switchable number of poles, - induction or synchronous motors supplied either from the network or from power-generator set (lower frequency, also lower voltage).
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 71; 135-141
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Doświadczenia Grupy Cantoni w zakresie silników energooszczędnych
Experiences of Cantoni Group in developing of energy efficient motors
Autorzy:
Damm, Z.
Powiązania:
https://bibliotekanauki.pl/articles/2076303.pdf
Data publikacji:
2005
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki elektryczne
energooszczędność
Opis:
This paper presents experiences of Polish manufacturers of electric motors combined in Cantoni Group in designing and producing of energy efficient motors. New products of Cantoni Group in scope of energy efficient motors are presented. Moreover Cantoni Group cooperate with European and American Units that certify energy efficient motors. One of the most important problems is to unify mothods of determining of efficiency.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2005, 73; 55-60
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modele liniowe serwosilników prądu stałego - systematyzacja
Linear models of DC servomotors - systematisation
Autorzy:
Missala, T.
Powiązania:
https://bibliotekanauki.pl/articles/159227.pdf
Data publikacji:
2003
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
silniki elektryczne
model liniowy
Opis:
W analizie pracy dynamicznej i sterowania serwomechanizmów prądu stałego są wykorzystywane modele liniowe silników napędowych. Model dynamiczny silnika jest, jak wiadomo, scharakteryzowany: stałymi momentu K(T), napięcia K(E), tarcia lepkiego K(D), tarcia suchego T(F), momentem bezwładności J, rezystancją R(a), i indukcyjnością L(a) wirnika. Z parametrów tych wynikają stałe czasowe: elektromagnetyczna, elektromechaniczna i bezwładności. W zależności od konstrukcji silnika, rodzaju sterowania i zastosowania niektóre parametry można pominąć. Prowadzi to do modeli o różnym stopniu złożoności, odpowiednio mniej lub bardziej dokładnie odtwarzających zjawiska rzeczywiste. Na podstawie równań i schematów blokowych zdefiniowano 10 modeli: sześć stopnia pierwszego i cztery stopnia drugiego. Podano ich transmitancje, wyrażenia do określenia prądów, końcowych prędkości kątowych i przyspieszeń przy rozruchu.
The dynamic properties of the DC servomotors are described by the set of parameters: armature polar moment of intertia - J; voltage constant - K(E); viscous damping constant - K(D); electromagnetic torque constant - K(T); dry friction torque - T(f); armature resistance - R(a); armature inductance - L(a) and resulting parameters: armature electromagnetic time constant - T(a); electromechanical time constant - T(m); inetria time constant - T(B). In relation to the servomotor construction (permanent magnet motor or electromagnetic excited motor), the kind of source of supply (voltage source or current source) and work conditions (dry friction is low or high), same of the motor parameters can be neglected by the dynamic analysis, what leads to diversity of mathematical models. The formula (1) to (9) present the basis set of equations. The diversity of models is illustrated on the block diagrams - figures 1 to 4. The diagrams - figures 1 and 4 present the case of voltage source supply, figures 2 and 3 - the case of current source supply. The formula (11), (20), (33) and (41) present the transfer functions of four mathematical models, which are developed on the basis of the diagram, fig. 1. The formula (27) and (30) present the transfer functions derived from the diagrams fig. 2. and 3. The formula (48), (58), (67) and (75) - the transfer functions derived from diagram, fig. 4. The remaining formulas describe the other characteristics of the motors. The systematic presentation of the dynamic characteristics of the DC servomotors is intended as a facility by the analysis of motion systems.
Źródło:
Prace Instytutu Elektrotechniki; 2003, 216; 81-102
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Silniki reluktancyjne - badania eksperymentalne
Reluctance motors - measurements results
Autorzy:
Zawilak, T.
Wieczorek, A.
Damm, Z.
Zawilak, J.
Powiązania:
https://bibliotekanauki.pl/articles/2076386.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik reluktancyjny
silniki elektryczne
Opis:
This paper presents experimental results of two different structures of reluctance motors with asynchronous starting. The torque, speed and stator current transient were measured during motor's line start up. The comparison of both structure is made.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2007, 77; 273-276
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wyników pomiarów wyładowań niezupełnych w silnikach elektrycznych
Interpreting partial discharge test results from motor
Autorzy:
Szymaniec, S.
Powiązania:
https://bibliotekanauki.pl/articles/1374324.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki elektryczne
wyładowania niezupełne
pomiary
Opis:
Partial discharge monitoring is an effective on-line predictive maintenance test for 6 kV motors. An understanding of the theory related to partial discharge, and the relationship to early detection of insulation deterioration is required to properly evaluate this predictive maintenance tool. This paper will present a theory to promote the understanding of partial discharge technology, as well as various implementation and measurement techniques that have evolved in the industry. Data interpretation, corrective actions and application to electrical distribution equipment will also bereviewed.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2007, 76; 95-100
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ niewyważenia na kondycje silników elektrycznych i maszyn elektrycznych. Niewyważenie zespołu wirujacego silnika jako jeden z podstawowych problemów maszyn elektrycznych
Influence unbalance on shape of electrical engines (armatures) and electrical machines (unbalance of rotating assembly as an essential problem of electrical machines
Autorzy:
Cimr, P.
Powiązania:
https://bibliotekanauki.pl/articles/1374336.pdf
Data publikacji:
2007
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
niewyważenie
silniki elektryczne
maszyny elektryczne
Opis:
During presentation there will be raised all aspects of balancing technology. Definitions concerning unbalance states as well as reasons and consequences of unbalance will be explained in details. There will be presented quality grades of balancing and correction methods, with special emphasis on electrical rotors balancing. There will be also presented different solution concerning cycle time: from manual to fully automatic. Paper includes also explaining safety aspects of balancing technology according to ISO and showing a film about modern, automatic balancing systems for electric armatures.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2007, 76; 11-17
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niektóre aspekty doboru silników energooszczędnych zastępujących silniki standardowe
Some aspects of a choise of the energy-efficient motors used in the place of the standard motors
Autorzy:
Zapaśnik, R.
Powiązania:
https://bibliotekanauki.pl/articles/1374361.pdf
Data publikacji:
2006
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silniki elektryczne
energooszczędność
efektywność energetyczna
Opis:
Speeds of the energy-efficient motors are almost always higher than the speeds of the standard motors identical with the rated outputs and the number of poles. It is necessary, these speed differences to take into account in evaluation of the energy effect obtained as a result of application the energy-efficient motor instead of standard one. The recommendation is especially essential as the energy-efficient motor has the die-cast copper rotor.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2006, 74; 1-3
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies