Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Sewage" wg kryterium: Temat


Tytuł:
Reliability of sewage treatment plants processing sewage from school buildings located in non-urban areas
Autorzy:
Bugajski, P.
Almeida, M. A. A.
Kurek, K.
Powiązania:
https://bibliotekanauki.pl/articles/101488.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
sewage
reliability
on-site sewage treatment facility
Opis:
The aim of this study was to assess the reliability of two on-site sewage treatment facilities (BCT S-12 and TJ EP-4) serving two school buildings located in rural communes in Małopolska region. The reliability was determined using Weibull reliability method. The research was conducted for 24 months and it involved the collection and analysis of 48 samples of raw and treated sewage from each facility. The analyses included organic and biogenic pollution, i.e. BOD5 , COD, and total nitrogen. Reliability assessment revealed the following effectiveness for BCT S-12 facility: 77% for BOD5 , 96% for COD and 25% for total nitrogen. For TJ EP-4 facility, the effectiveness was 81%, 88% and 72% for BOD5 , COD and total nitrogen, respectively. Both facilities used the activated sludge process and experienced periodic disturbances in the treatment flow that resulted in reduced sewage treatment efficiency. Considering the above, the processes of nitrification and denitrification in the biological reactor should be streamlined to provide more effective removal of organic and nitrogen-based compounds in the investigated facilities.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, IV/3; 1547-1557
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the sewage system expandability in Mściwojów commune
Autorzy:
Bergel, T.
Bugajski, P.
Pawełek, J.
Powiązania:
https://bibliotekanauki.pl/articles/100285.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Rolniczy im. Hugona Kołłątaja w Krakowie
Tematy:
sewage system
expansion
sewage
kanalizacja
rozwój
ścieki
Opis:
The aim of the study is to analyze the hydraulic conditions of the existing sewage system and the sewage treatment plant in the commune of Mściwojów. This is in relation to the aspect of connecting new buildings, as a part of the investments in the pilot project VITAL LANDSCAPES no. 2CE164P3. The analysis led to the conclusion that an increased wastewater inflow from the new buildings is manageable. The current capacity of the sewage treatment plant will be increased by 3 to 5%, which will not affect the stability of the existing treatment process. The hydraulic analysis of the sewer network proved that the existing sewer collectors can handle the increased flow.
Źródło:
Geomatics, Landmanagement and Landscape; 2013, 2; 7-14
2300-1496
Pojawia się w:
Geomatics, Landmanagement and Landscape
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza procesu technologicznego w zakładzie oczyszczania ścieków i przygotowania osadów
Analysis of the technological process in the sewage treatment plant
Autorzy:
Richter, D.
Fokczyńska, E.
Ogłaza, P.
Kijo-Kleczkowska, A.
Środa, K.
Powiązania:
https://bibliotekanauki.pl/articles/357309.pdf
Data publikacji:
2016
Wydawca:
Politechnika Śląska
Tematy:
sewage treatment plant
sewage
sewage sludge
oczyszczalnia ścieków
ściek
osad ściekowy
Opis:
The paper presents an analysis of the technological process of wastewater treatment and the process of preparation of sludge in a wastewater treatment plan t in Koszęcin. Firstly we presented the location of the plant, described its characteristics and discussed the environmental conditions of the functioning of the plant. Then we investigated parameters of the process and technology in the considered plant, the stages of wastewater tratment and dewatering of excess sludge. Also we presented laboratory tests of wastewater and sludge.
W pracy zaprezentowano analizę procesu technologicznego oczyszczania ścieków oraz przygotowania osadów w oczyszczalni ścieków w Koszęcinie. Na wstępie zaprezentowano lokalizację zakładu, dokonano jego charakterystyki oraz omówiono warunki środowiskowe funkcjonowania wspomnianej oczyszczalni. Rozpatrzono parametry procesowo-technologiczne w rozpatrywanym zakładzie etapy oczyszczania ścieków i odwadnianie osadu nadmiernego. Przedstawiono również badania laboratoryjne ścieków i osadów.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2016, 18, 3; 35-50
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of Flushing of Sewage Sludge Collected on the Bottom of a Retention Chamber
Autorzy:
Malmur, R.
Mrowiec, M.
Powiązania:
https://bibliotekanauki.pl/articles/125069.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
drainage system
retention
sewage
sewage reservoirs
transfer reservoirs
Opis:
This paper presents new achievements in the field of designing the gravitation and gravitation-underpressure chamber for bottom flushing in the detention chamber immediately after its emptying from the accumulated sewage. Temporary accumulation of the sewage in the detention chamber of the reservoir causes partial sedimentation of the solids suspended in the liquid. The location of the flushing chamber at the maximal level of filling with sewage in the retention chamber substantially improves the effectiveness of flushing of the bottom of the retention chamber with the stream of sewage that is discharged from the flushing chamber. An opportunity for effective flushing of the sludge that remains on the bottom of a detention chamber represents an important operation which is essential for reliable functioning of retention reservoirs within sewerage systems.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 200-209
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność termicznego przekształcania osadów na tle innych metod zagospodarowania na przykładzie wybranej oczyszczalni ścieków
Sludge thermal processing efficiency compared to other methods of management on the example of selected wastewater treatment plant
Autorzy:
Rybicki, S. M.
Łuszczek, B.
Powiązania:
https://bibliotekanauki.pl/articles/297246.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
oczyszczanie ścieków
przeróbka osadów
suszenie osadów
termiczna przeróbka osadów
sewage
sewage sludge
agricultural use of sewage sludge
natural use of sewage sludge
Opis:
Oczyszczalnia ścieków Kraków-Płaszów (największy obiekt spośród dziewięciu oczyszczalni obsługujących aglomerację) została zmodernizowana w latach 2004-2007, tak że obecnie jest obiektem o przepustowości 165 tys. m3/dobę, składającym się z 5 reaktorów biologicznych i 10 osadników wtórnych. Przeróbkę osadu realizuje się w całkowicie nowym obiekcie, w którym prowadzi się zagęszczanie, fermentację metanową, końcowe odwadnianie oraz produkcję energii elektrycznej i ciepła użytkowego z gazu fermentacyjnego. W 2009 roku uruchomiono obiekt Stacji Termicznej Utylizacji Osadów o przepustowości średnio 64 ton suchej masy na dobę, spełniającej wymogi najlepszych dostępnych technik. Celem budowy była minimalizacja kosztów transportu i zagospodarowania osadów, jako że oczyszczalnia, która lokalizowana była przed półwieczem daleko poza miastem, obecnie w całości znajduje się wewnątrz gęsto zabudowanego obszaru. Dążenie do minimalizacji ryzyka związanego z transportem tzw. masy mokrej oraz chęć ogólnego obniżenia kosztów stały się podstawą zastosowania wybranej metody. W artykule przedstawiono wyniki z pierwszych lat eksploatacji obiektu. Na podstawie doświadczeń zebranych w trakcie eksploatacji pokazano, jakie problemy należało rozwiązać przy uruchamianiu i wstępnym eksploatowaniu tego obiektu, tak aby uzyskać stabilną, ekonomicznie uzasadnioną eksploatację obiektu. Wobec braku rzeczywistych możliwości rolniczego (czy tzw. „proekologicznego”) wykorzystania osadów (lokalizacja obiektu w dużej odległości od terenów uprawowych) metoda suszenia może być dobrą alternatywą zagospodarowania osadów, szczególnie dla dużych oczyszczalni, które zlokalizowane są w oddaleniu od obszarów intensywnie eksploatowanych rolniczo.
Wastewater treatment plant Krakow-Plaszow (the largest of the nine sewage treatment facilities serving the agglomeration), was upgraded between 2004 and 2007, so that it is an object with a capacity of 165 thousand m3/day, consisting of 5 bioreactors and 10 secondary settling tanks. Sludge processing is carried out in brand-new train consisting of sludge thickening, mesophilic digestion (with methane-rich gas production) the final dewatering and heat production of the fermentation gas. In year 2009 the Thermal Utilization of Sludge station was launched, with a capacity of 64 tons on average dry matter per day, fulfilling the requirements of best available techniques. The purpose of the construction was to minimize transport costs and land deposits, as the object Krakow-Plaszow, which half a century ago was located far outside the city, now is entirely located within the densely built-up area. Aiming to minimize the risks associated with the transport of so-called wet mass and the desire to reduce the overall cost became the basis for the application of the chosen method. The paper presents the results of the first years of operation of the facility. Based on experience gained during the operation shows which problems had to be solved at startup and initial exploitation of this property, so as to balance the production of biogas and energy recovery from it with needs drying sludge. In the absence of the real possibilities of agricultural (or so-called ‘ecological’) use of sludge (location of the object at a great distance from land cultivation) drying method may be a good alternative sludge management. Operational experiences proved that proposed method of thermal utilization of digested sludge is a reliable method leading to minimization of the burden on wastewater sludge and especially significant - more than five times - reducing the volume of total waste then an ecological footprint of the plant. Unit consumption of chemicals as well as electrical energy and biogas is relatively low comparing with other technologies. Use of a biogas produced on the plant for thermal stabilization only slightly reduces the disposable surplus of this energy carrier on a scale wastewater treatment plant.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 3; 377-391
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conditions of agricultural and natural use of sewage sludge in rural areas
Uwarunkowania rolniczego i przyrodniczego wykorzystania osadów ściekowych na terenach wiejskich
Autorzy:
Bauman-Kaszubska, H.
Sikorski, M.
Powiązania:
https://bibliotekanauki.pl/articles/297591.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
sewage
sewage sludge
agricultural use of sewage sludge
natural use of sewage sludge
ścieki
osady ściekowe
rolnicze wykorzystanie osadów ściekowych
przyrodnicze wykorzystanie osadów ściekowych
Opis:
Steady increase in sludge quantity emerging from municipal sewage treatment plants and shortcoming in managing sludge cause that problems of sludge management require urgent solution. The final stage of sewage sludge disposal should be its agricultural or natural utilization. This is possible if the sludge complies with qualitative requirements (stabilization, decontamination, composting). In the report there will be presented the analysis and estimation of possibilities of agricultural or natural use of sewage sludge as organic fertilizers. Municipal sewage sludge, produced in sewage treatment plants, is not a fertilizer and can not be treated like natural fertilizer e.g. manure. It can be used in agriculture in processed and not processed form and on condition that it is stabilized and fulfills requirements in permissible levels of heavy metals and sanitary indicators and included definite quantities of organic matter and fertilize compounds of nitrogen, phosphorus and potassium. It can be treated as organic fertilizers according to the act on fertilizers and manuring. The additional point of consideration is the problem connected with sewage sludge in relation to special planning and managing. The important role plays possibility of disposing proper base of areas, fields in it (agricultural and green grounds) fulfilling particular requirements as far as the content of heavy metals is concerned taking into consideration ecological and physiographic condition. Therefore on every step of studying water - sewage and sewage sludge management in the variant expression it is essential to carry out recognition and listing of areas e.g. in the form of multiaspect survey. The starting point for consideration concerning processing and possible managing of sewage sludge for agricultural or natural aims is recognition of range of conditions connected with it. The law regulations mentioned before are uppermost and stating quantity and quality characterization of sewage sludge made in sewage treatment plants yearly as well. In the article the quality characterization of sewage sludge made in sewage treatment plants serving rural settlement units and small cities from the point of view of fertilizing compounds contents (N, P, K) and heavy metals will be included. Precise knowledge of sewage sludge characteristic is the basis of choice as far as proper way of its processing, usage and management is concerned. The next criteria of dealing with sewage sludge will be preparation of sewage sludge preceding their agricultural or natural use. Particularly there will be discussed law essentials including quality requirements of sewage sludge and areas characterization, on which they would be used, stating annual doses of sludge used in an agricultural or natural way with taking into consideration needs of plants, the degree of plants demand for nitrogen from this source, the content of nitrogen in sludge or composts made on their basis and fertilization equivalent of nitrogen in relation to mineral fertilizers.
Stały wzrost ilości osadów powstających w komunalnych oczyszczalniach ścieków oraz niedociągnięcia w zakresie ich zagospodarowania powodują, że problemy gospodarki osadowej wymagają pilnego rozwiązania. Końcowym etapem unieszkodliwiania komunalnych osadów ściekowych powinno być ich rolnicze bądź przyrodnicze wykorzystanie, oczywiście po spełnieniu przez nie wymagań jakościowych (osady ustabilizowane, odkażone, przekompostowane). W artykule zostanie przedstawiona analiza i ocena możliwości rolniczego bądź przyrodniczego wykorzystania osadów ściekowych jako nawozów organicznych. Komunalne osady ściekowe, powstające w oczyszczalniach ścieków, nie są nawozami i nie mogą być traktowane jak nawozy naturalne, np. obornik. Mogą być stosowane w rolnictwie w formie przetworzonej i nieprzetworzonej pod warunkiem, że są ustabilizowane i spełniają wymagania dopuszczalnych poziomów metali ciężkich oraz wskaźników sanitarnych, a także zawierają określone ilości substancji organicznych oraz związków nawożących azotu, fosforu i potasu. Mogą być wówczas traktowane jako nawozy organiczne zgodnie z ustawą o nawozach i nawożeniu. Dodatkowym punktem rozważań jest problematyka wykorzystania osadów ściekowych w odniesieniu do planowania i zagospodarowania przestrzennego. Istotną rolę odgrywa możliwość dysponowania odpowiednim zapleczem terenów, w tym pól (gruntów ornych i użytków zielonych) spełniających określone wymagania ze względu na zawartość metali ciężkich z uwzględnieniem uwarunkowań ekologicznych i fizjograficznych. Zatem na każdym etapie opracowywania gospodarki wodno-ściekowej i osadami ściekowymi w ujęciu wariantowym konieczne jest przeprowadzenie rozpoznania i inwentaryzacji terenów np. w formie wieloaspektowej ankiety. Punktem wyjścia do rozważań dotyczących przeróbki i ewentualnego zagospodarowania osadów ściekowych w celach rolniczych bądź przyrodniczych jest rozpoznanie szeregu uwarunkowań z tym związanych. Na pierwszy plan wysuwają się wspomniane podstawy prawne oraz określenie charakterystyki ilościowej i jakościowej osadów ściekowych powstających w ciągu roku w oczyszczalni ścieków. W pracy zawarto zatem charakterystykę jakościową osadów ściekowych powstających w oczyszczalniach obsługujących wiejskie jednostki osadnicze i małe miasta z punktu widzenia zawartości związków nawożących (N, P, K) oraz metali ciężkich. Bardzo dokładne poznanie charakterystyki osadów jest podstawą wyboru odpowiedniego sposobu ich przeróbki, wykorzystania lub zagospodarowania. Kolejnymi kryteriami wyboru sposobu postępowania z osadami będzie przygotowanie osadów ściekowych poprzedzające ich rolnicze bądź przyrodnicze wykorzystanie. W szczególności omówione zostanie określenie rocznych dawek osadów ściekowych wykorzystywanych rolniczo bądź przyrodniczo z uwzględnieniem potrzeb roślin, stopnia pokrycia potrzeb roślin na azot z tego źródła, zawartości azotu w osadach bądź kompostach tworzonych na ich bazie oraz równoważnika nawozowego azotu w odniesieniu do nawozów mineralnych.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 1; 105-115
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the Hydraulic Load of a Local WWTP in the South-Eastern Poland Including Hydraulic Capacity of the Sewage Receiver
Autorzy:
Młyńska, Anna
Młyński, Dariusz
Chmielowski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2202274.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
hydraulic load
sewage
sewage receiver
sewage outflow
mean low flow
SNQ
wastewater treatment plant
WWTP
Opis:
The paper constitutes the analysis of hydraulic load of a local wastewater treatment plant in the south-eastern Poland along with the analysis of sewage receiver hydraulic capacity and related receiving waters protection. Assuming that the daily outflow of treated sewage should not exceed 10% of the mean-low flow (SNQ) of the receiver, no case of daily sewage outflow greater than 10%·SNQ = 51 840 m3·d-1 was recorded. Moreover, average daily hydraulic load of the treatment plant was lower than the limit value by over 70% and the maximum recorded value – by over 40%. Furthermore, the conducted analysis shows that the particular months differed from each other in the values of the daily hydraulic load of the wastewater treatment plant at the outflow; May was the month with the highest average daily sewage outflow, while September was characterized by the lowest average daily outflow of treated sewage. There was also no clear dependence between the hydraulic load of the WWTP and the day of the week. Daily sewage outflows ranging from 10 000 m3·d-1 to 12 000 m3·d-1 constituted the largest part of all observations. The daily sewage outflows directed to the receiver prove that there is no threat to the preservation of the water environment quality.
Źródło:
Journal of Ecological Engineering; 2022, 23, 11; 261--272
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena pracy oczyszczalni ścieków w Starachowicach
Validation of the operations of wastewater treatment plant in Starachowice
Autorzy:
Budkowska, A.
Długosz, J.
Gawdzik, J.
Powiązania:
https://bibliotekanauki.pl/articles/357090.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska
Tematy:
ścieki
oczyszczalnia ścieków
wskaźniki zanieczyszczeń
sewage
sewage treatment plant
pollutants indexes
Opis:
W pracy przedstawiono ocenę funkcjonowania jednej  z największych oczyszczalni ścieków w województwie świętokrzyskim - oczyszczalni ścieków komunalnych w Starachowicach. Ocenę sprawności działania oczyszczalni oparto na wielkości redukcji 5 wybranych wskaźników zanieczyszczeń: BZT5, ChZT, zawiesina ogólna, azot ogólny i fosfor ogólny. Redukcja wszystkich analizowanych wskaźników z wyjątkiem azotu ogólnego była na poziomie wyższym od wytycznych podanych w Rozporządzeniu z dnia 31 lipca 2006 roku. Przedstawiono charakterystykę procesów jednostkowych oraz dokonano oceny efektywności systemu oczyszczania ścieków na oczyszczalni. Analizując wartości średniodobowego niskiego przepływu rzeki oraz średniej dobowej ilości ścieków odprowadzanej do odbiornika  można stwierdzić, iż rzeka Kamienna jest odpowiednim odbiornikiem dla oczyszczonych ścieków.
The paper presents an evaluation of functioning of one sewage treatment plant in Swietokrzyskie Province – wastewater treatment plant near Starachowice. Evaluation of operation capacity was based on reduction size of 5 chosen pollutants' indexes: BOD5, COD, total suspended solids, total nitrogen and total phosphorus. Reduction of all analysed indexes except total nitrogen and total phosphorus was on the level higher than guidelines given by the Ordinance from 31st July 2006. The characteristics of unit processes and assessment of the effectiveness of the sewage treatment systems was done in this work. Analyzing of the average daily volume of wastewater discharged into the receiver can be concluded, that Kamienna river is a suitable receiver for the treated wastewater.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2012, 14, 3; 1-11
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ ścieków oczyszczonych na oczyszczalni w Myślenicach na jakość wód ich odbiornika
Impact of treated sewage on sewagetreatment plant in Myślenice on the quailty of their receiver
Autorzy:
Miernik, W.
Młyński, D.
Wałęga, A.
Chmielowski, K.
Karwacki, A.
Powiązania:
https://bibliotekanauki.pl/articles/101265.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki
oczyszczalnia
odbiornik
rzeka Raba
sewage
sewage treatment plant
receiver
Raba river
Opis:
Artykuł zawiera analizę i ocenę wpływu ścieków oczyszczonych w oczyszczalni w Myślenicach w latach 2008 - 2011, na skład fizyczno-chemiczny oraz jakość wód ich odbiornika - rzeki Raby. Pracę wykonano na podstawie zebranych oraz statystycznie opracowanych wyników badań, obejmujących ilość i skład ścieków oczyszczonych, odprowadzanych do Raby, a także skład wód odbiornika w przekrojach Stróże i Osieczany, znajdujących się odpowiednio powyżej i poniżej punktu zrzutu ścieków oczyszczonych. Zakres wskaźników zanieczyszczeń oznaczanych w ściekach i wodzie obejmował: zawiesinę ogólną, BZT5 , ChZTCr, fosfor ogólny oraz azot ogólny. Na podstawie wykonanych badań stwierdzono, że oczyszczalnia ścieków w Myślenicach, w latach 2008 - 2011, funkcjonowała prawidłowo, ponieważ oczyszczone na niej ścieki, spełniały wymogi pozwolenia wodno-prawnego, co przekładało się bezpośrednio na skuteczną ochronę przed zanieczyszczeniem wód ich odbiornika. Ponadto stwierdzono, że w obu badanych przekrojach skład fizyczno-chemiczny wód Raby był do siebie zbliżony. Potwierdziły to wyniki zastosowanego testu U Mann'a-Whitney'a, które nie wykazały statystycznie istotnych różnic pomiędzy średnimi wartościami stężeń analizowanych wskaźników zanieczyszczeń. Ścieki oczyszczone, odprowadzane z oczyszczalni w Myślenicach do rzeki Raby nie przyczyniają się do pogorszenia jakości jej wód.
The article contains analysis and evaluation of the impact of clean sewage on sewage treatment plant in Myślenice, in the period 2008 - 201,1 on the physico-chemical composition and water quality of the receiver - river Raba. The analysis conducted based on collected and statistical research: amount and composition of clean sewage and composition of the water receiver in cross-section: Stróże (above of inflow clean sewage) and Osieczany (below of inflow clean sewage). The following pollution index were tested: total suspended solids, BOD5, CODCr, total nitrogen and total phosphorus. Based on obtained results its concluded that in period 2008 - 2011 sewage treatment plant was working properly, what explain quality of clean sewage. What reflected in directly protection of receiver water against pollution. Moreover, based on the results of U Mann Whitney test, concluded that in the both cross-section, composition of the water of Raba river was similar, what explain the results of this test, which didn't show statistically significant differences between average values of concentrations analyzed indicators of pollutions. Based on obtained results its concluded that sewage treatment plant in Myślenice doesn't negatively impact on quality of the water receiver -Raba river.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, I/1; 191-207
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności pracy oczyszczalni ścieków w Jaśle
Evaulation of efficency of sewage treatment plant in Jasło
Autorzy:
Młyński, D.
Chmielowski, K.
Młyńska, A.
Miernik, W.
Powiązania:
https://bibliotekanauki.pl/articles/101438.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
ścieki
oczyszczalnia ścieków
niezawodność pracy
sewage
sewage treatment plant
reliability of work
Opis:
Artykuł zawiera ocenę funkcjonowania oczyszczalni ścieków w Jaśle, w wieloleciu 2010 - 2014. Na podstawie wyników badań fizyko-chemicznych ścieków surowych i oczyszczonych wyznaczono wskaźniki niezawodności pracy oczyszczalni takie jak: sprawność oczyszczania, współczynnik niezawodności technologicznej, technologiczną sprawność oczyszczania oraz ryzyko negatywnej oceny działania oczyszczalni, w odniesieniu do następujących wskaźników zanieczyszczeń: zawiesina ogólna, BZT5 , ChZTCr, azot ogólny oraz fosfor ogólny. Na podstawie przeprowadzonych, badań stwierdzono, że średnia redukcja ładunku zanieczyszczeń kształtowała się na poziomie powyżej 90%. Tylko w przypadku azotu ogólnego średnia redukcja była niższa i wynosiła 77%. Bazując na wynikach obliczeń pozostałych wskaźników niezawodności stwierdzono, że badana oczyszczalnia ścieków działała poprawnie i oczyszczała ścieki, których skład spełniał wymogi pozwolenia wodno-prawnego.
The article contains evaluation of functionality of sewage treatment plant in Jasło for multiplicity 2010 - 2014. On the basis of the results raw and cleaned sewage physico-chemical analysis, the efficiency of sewage treatment, coefficient of technological reliability, technological efficiency of sewage treatment and risk of the negative assessment of work of sewage treatment plant, were obtained, for following pollutions indicators: total suspended solids, BOD5 , CODCr, total nitrogen and total phosphorus. Based on obtained results its conclude the average reduction of pollution on level below 90%. Only for total nitrogen the average reduction is lower and is on level 77%. Based on other values of indicators of reliability work of sewage treatment plant its conclude that the tested sewage treatment plant may be certified to operate in high quality and the sewage treated by this plant doesn't threaten the collector of the treated sewage.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2016, I/1; 147-162
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena poprawności funkcjonowania miejskiej oczyszczalni ścieków w Piasecznie
Validation of the operations of municipal wastewater treatment plant in Piaseczno
Autorzy:
Długosz, J.
Gawdzik, J.
Powiązania:
https://bibliotekanauki.pl/articles/357202.pdf
Data publikacji:
2012
Wydawca:
Politechnika Śląska
Tematy:
ścieki
oczyszczalnia ścieków
wskaźniki zanieczyszczeń
sewage
sewage treatment plant
pollutants’ indexes
Opis:
W pracy przedstawiono ocenę funkcjonowania oczyszczalni ścieków komunalnych w Piasecznie. Ocenę sprawności działania oczyszczalni oparto na wielkości redukcji 5 wybranych wskaźników zanieczyszczeń: BZT5, ChZT, zawiesina ogólna, azot ogólny i fosfor ogólny. Obiekt uzyskuje bardzo dobre wyniki w oczyszczaniu ścieków, które zgodne są z dopuszczalnymi wartościami zawartymi w Rozporządzeniu Ministra Środowiska z dnia 24 lipca 2006 oraz z pozwoleniem wodnoprawnym. Przedstawiono charakterystykę procesów jednostkowych oraz dokonano oceny efektywności systemu oczyszczania ścieków na oczyszczalni. Analizując wartości średniodobowego niskiego przepływu rzeki oraz średniej dobowej ilości ścieków odprowadzanej do odbiornika można stwierdzić, iż Kanał Piaseczyński jest odpowiednim odbiornikiem dla oczyszczonych ścieków
The paper presents an evaluation of functioning wastewater treatment plant near Piaseczno. Evaluation of operation capacity was based on level of reduction of 5 chosen pollution indexes: BOD5, COD, total suspended solids, total nitrogen and total phosphorus Very good results of wastewater treatment, which complies with the limit values laid down in the Regulation of the Minister of Environment of 24 July 2006 and in the water-legal permission were achieved. The characteristics of unit processes and assessment of the effectiveness of the sewage treatment systems were done in this work. River and the average daily volume of wastewater discharged into the receiver can be concluded, that Kanał Piaseczyński is a suitable receiver for the treated wastewater.
Źródło:
Archiwum Gospodarki Odpadami i Ochrony Środowiska; 2012, 14, 4; 31-40
1733-4381
Pojawia się w:
Archiwum Gospodarki Odpadami i Ochrony Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innovative activities in the water and sewage industry
Autorzy:
Ober, Józef
Karwot, Janusz
Powiązania:
https://bibliotekanauki.pl/articles/393088.pdf
Data publikacji:
2019
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
innovations
sewage
sewerage
water and sewage industry
innowacje
ścieki
kanalizacja
przemysł wodno-ściekowy
Opis:
The purpose of this study is to analyze and present the results of research devoted to the development and intentions of water and sewage companies operating on the Polish market in the context of innovation. The data collected and analysed in the research has not been published yet. The specific purposes of the study is to describe the state of innovation of water and sewage companies operating across the country, and to indicate the directions for their development, their barriers and problems in the context of implementing innovation. The first part of the study focuses on the theoretical aspects of innovative activities of municipal companies, and characterizes the notions of innovation and innovativeness. In its subsequent part, the study describes the object, subject, purpose of the study, the research methods and techniques applied in the paper. The analysis and discussion of a selected research part is included in the last part of the study, which is closed by the final conclusions.
Źródło:
Organizacja i Zarządzanie : kwartalnik naukowy; 2019, 2; 87-97
1899-6116
Pojawia się w:
Organizacja i Zarządzanie : kwartalnik naukowy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza przydomowego rozwiązania do oczyszczania ścieków
Analysis of domestic sewage treatment system
Autorzy:
Pawlita-Posmyk, M.
Wzorek, M.
Powiązania:
https://bibliotekanauki.pl/articles/1215418.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
ścieki
oczyszczanie
przydomowa biologiczna oczyszczalnia ścieków
sewage
wastewater treatment
domestic sewage treatment plant
Opis:
Zainteresowanie przydomowymi rozwiązaniami do oczyszczania ścieków wzrasta i technologie te cieszą się coraz większą popularnością. Przydomowe oczyszczalnie ścieków wciąż są udoskonalane i rozwijane, aby skutecznie podnosić efektywność oczyszczania ścieków oraz obniżać koszty użytkowania. W artykule przedstawiono jedno z nowocześniejszych rozwiązań dostępnych na rynku oraz dokonano oceny jego pracy w zakresie dotrzymywania parametrów ścieków oczyszczonych. W ściekach oczyszczonych oznaczano podstawowe wskaźniki zanieczyszczeń, które porównano z danymi producenta oraz wartościami dopuszczalnymi (zgodnie z RMŚ z dn. 18 listopada 2014 r.). Na podstawie przeprowadzonych badań stwierdzono, że dzięki badanej technologii można efektywnie oczyszczać ścieki z domostw, gdzie nie ma możliwości korzystania z kanalizacji zbiorowej.
There is a growing interest in household sewage treatment systems with increasing popularity of such solutions. Household sewage treatment systems are constantly improved and developed in order to effectively increase efficiency of wastewater treatment and reduce operation costs. The article presents one of commercially available state-of-the-art solutions with assessment of its operation in terms of obtaining parameters of treated wastewater. Basic contamination indicators were determined for treated wastewater and compared with manufacturer data and allowable values (According to the Regulation of the Ministry of Environment of 18th November 2014). The conducted studies lead to the conclusion that the studied technology can be used successfully to treat household wastewater in the areas where no collective sewage system is available.
Źródło:
Chemik; 2016, 70, 10; 620-625
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of water supply and sewage systems in rural areas of Małopolskie and Podkarpackie Voivodeships
Autorzy:
Bargiel, T.
Chmielowski, K.
Pawełek, J.
Powiązania:
https://bibliotekanauki.pl/articles/100550.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Rolniczy im. Hugona Kołłątaja w Krakowie
Tematy:
water supply network
sewage system
rural areas
sewage
ściek
system ściekowy
obszary wiejskie
Opis:
The paper presents the development of water supply networks and sewage systems in rural areas of Małopolskie and Podkarpackie Voivodeships in the Polish context. The scope of the thesis includes the analyses of length of water supply networks and sewage systems, number of people using them, number of water and sewage connections and volume of used water and volume of discharged sewage. The results of the study were presented in the graphs. The research material was taken from the reports on municipal infrastructure published by The Polish Central Statistical Office (GUS) for 2002-2012 and Local Data Bank (BDL) for 1995-2001. Though there has been a significant improvement in water supply and sewage systems, Poland will have great difficulty in meeting the requirements concerning their development in rural areas by 2015.
Źródło:
Geomatics, Landmanagement and Landscape; 2014, 3; 17-32
2300-1496
Pojawia się w:
Geomatics, Landmanagement and Landscape
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gravimetric Evolution During Sewage Sludge Biostabilization
Autorzy:
Posligua, P.
Peñaherrera, M.
Villegas, E.
Banchón, C.
Powiązania:
https://bibliotekanauki.pl/articles/124697.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pathogens
biosolids
sewage
mesophilic
anaerobic
Opis:
Sewage sludge is a by-product in the wastewater treatment and is an inherent hazardous issue because of the pathogenic contamination of natural resources. Therefore, in this study, domestic sludge was treated with premontane forest soil, macronutrients, and also pasteurization to reduce the content of volatile solids and pathogens. The best biostabilization treatment using premontane forest soil and pasteurization obtained a volatile solids reduction of 87% according to the environmental regulations, in which a biosolid is stable in a range of 38% of volatile solids reduction. In less than 30 days in a mesophilic range, the coliform count was reduced up to 71% when using forest soil and pasteurization. Thus, a biosolid-class B was obtained using gravimetric means as a platform to promote fast quality control.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 76-85
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies