Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power system reliability" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Probabilistic methods in the reliability assessment of power units
Metody probabilistyczne w ocenie niezawodności bloków energetycznych
Autorzy:
Buchta, J.
Oziemski, A.
Powiązania:
https://bibliotekanauki.pl/articles/173015.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
system elektroenergetyczny
blok energetyczny
niezawodność
power system
power unit
reliability
Opis:
The paper presents results of reliability analysis made for a lignite-fired 370 MW rated power units installed in the Bełchatów Power Station. The concept of a standardized power unit and the method of a histogram with a set number of observations in each class were applied. The study includes analysis of probability distributions of operation times and repair times for the main power unit components. Empirical probability distribution functions have been identified and their parameters estimated in the study. The final forecast includes an estimation of such reliability measures like expected operation time, expected failure rate, average repair time and expected annual failure duration.
W artykule dokonano oceny niezawodności pracy krajowych bloków 370 MW opalanych węglem brunatnym, zainstalowanych w Elektrowni Bełchatów. W oparciu o koncepcję bloku reprezentatywnego i metodę histogramu o założonej liczbie realizacji w klasach wyznaczono rozkłady prawdopodobieństwa występowania czasów pracy i czasów awarii dla głównych urządzeń bloku oraz ich najbardziej zawodnych elementów. Następnie na podstawie estymacji parametrów uzyskanych w ten sposób rozkładów empirycznych określono dla tych elementów wartości oczekiwane ich podstawowych wskaźników niezawodnościowych: intensywności awarii, średniego czasu wyłączenia, łącznego czasu wyłączeń w ciągu roku i czasu pracy bezawaryjnej.
Źródło:
Archiwum Energetyki; 2012, 42, 3/4; 15-29
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy niezawodnościowo-eksploatacyjne układów zasilających elektroniczne systemy bezpieczeństwa
Reliability and operation aspects of power supply units for electronic safety systems
Autorzy:
Szulc, W.
Powiązania:
https://bibliotekanauki.pl/articles/276127.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
niezawodność
system bezpieczeństwa
źródło zasilania
reliability
safety system
power supply unit
Opis:
W artykule przedstawiono istotne problemy niezawodnościowo-eksploatacyjne dotyczące układów zasilających elektroniczne systemy bezpieczeństwa. Liczne badania długofalowe umożliwiły określenie istotnych wskaźników eksploatacyjnych i niezawodnościowych tak ważnych dla prawidłowego funkcjonowania elektronicznego systemu bezpieczeństwa.
In the paper the important reliability and operation aspects of power supply units for electronic safety systems are presented. The author has done an extensive long-term research which made possible the identification of reliability and operation indicators important for the proper functioning of electronic safety systems.
Źródło:
Pomiary Automatyka Robotyka; 2012, 16, 1; 54-63
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Regulacja jakościowa a niezawodność sieci dystrybucyjnej
Quality regulation and reliability of a distribution network
Autorzy:
Kornatka, Mirosław
Powiązania:
https://bibliotekanauki.pl/articles/266913.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
niezawodność
system elektroenergetyczny
regulacja jakościowa
SAIDI
SAIFI
reliability
power system
quality regulation
Opis:
W artykule przedstawiono wyniki analizy danych dotyczących niezawodności krajowych sieci dystrybucyjnych w świetle obowiązującej regulacji jakościowej. Obliczenia przeprowadzono w środowisku R z zastosowaniem nieparametrycznych metod analizy danych. Zaprezentowano rozkłady zmienności i rozrzuty wartości wskaźników SAIDI, SAIFI pięciu Operatorów Systemu Dystrybucyjnego. Graficzną prezentację wyników przedstawiono na wykresach pudełkowych. Przedstawiono również wybrane zagadnienia związane z obowiązującym w Polsce modelem regulacji jakościowej.
The power system it is the "bloodstream" of the economy, which supplies electricity to consumers in a given time and quantity. The article presents the results of the analysis of data on the reliability of Polish distribution networks in the years 2012-2018, in the light of the applicable quality regulation. Calculations were carried out in the R environment using nonparametric data analysis methods. Distribution of variation and spread of SAIDI and SAIFI indicators of five Distribution System Operators were presented. Graphic presentation of results is presented on box charts. Selected issues related to the quality regulation model in force in Poland were also presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 67; 21-24
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel power quality data analysis and reporting framework for wide-area system of registration and processing of power quality data
Autorzy:
Rezmer, J.
Leonowicz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/136208.pdf
Data publikacji:
2015
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
power quality
faults
power distribution
reliability
power system restoration
power system transients
relational databases
distributed generation
voltage dips
GIS
data visualization
data analysis
localization of disturbances
Opis:
This paper presents a novel method for data analysis and visualization, including real-time visual monitoring and proposal for combined area PQ indices on the example of the developed and operational comprehensive system of registration, archiving and data processing for the wide-area monitoring of power quality in a separated part of real power grid with distributed renewable generation. Real case studies related to power quality disturbances are presented.
Źródło:
Transactions on Environment and Electrical Engineering; 2015, 1, 1; 1-3
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane aspekty analizy niezawodnościowo-eksploatacyjnej układów zasilania systemów telematyki autostradowej
Selected aspects of reliability-exploitation analysis of power supply of highway telematics systems
Autorzy:
Rosiński, A.
Powiązania:
https://bibliotekanauki.pl/articles/158181.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
układ zasilania
niezawodność
eksploatacja
telematyka autostradowa
power supply system
reliability
exploitation
highway telematics
Opis:
W artykule zaprezentowano analizę dwutorowego układu zasilania systemu telematyki autostradowej w aspekcie niezawodnościowoeksploatacyjnym. Przyjmując trzy stany (pełnej zdatności SPZ, zagrożenia bezpieczeństwa QZB i zawodności bezpieczeństwa QB) oraz określone przejścia pomiędzy nimi, wyznaczono zależności pozwalające na wyznaczenie prawdopodobieństw przebywania układu zasilania systemu telematyki autostradowej w wymienionych stanach.
The reliability of functioning of highway telematics systems requires ensuring the adequate supply of the devices they consist of. Their failure is a failure in the system, which may result in interruption of the operation of the whole or a part of the system. Therefore, the devices are usually supplied from two sources. The first one is the main power supply. In the case of the main power supply failure, the system is automatically switched to the reserve power source. The paper presents the analysis of a two-way power supply of highway telematics system in terms of reliability-exploitation. Assuming three states (full ability SPZ, impendency over safety QZB and unreliability of safety QB) and certain transitions between them, there were determined the probabilities of staying the power supply highway telematics systems in those states.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 9, 9; 788-790
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza awaryjności oraz rangi stacji transformatorowych w sieci rozdzielczej SN
The analysis of failures and importance of transformer stations in MV distribution network
Autorzy:
Stasiak, N.
Subocz, J.
Powiązania:
https://bibliotekanauki.pl/articles/156787.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stacja transformatorowa SN/nn
awaryjność
ranga w systemie
transformer power station
reliability
importance in the distribution system
Opis:
W pracy omówiono najważniejsze strategie obsługi stacji rozdzielczych SN/nn. Przedstawiono ogólne założenia metody oceny rangi stacji w systemie elektroenergetycznym. Wykonano analizę awaryjności i rangi w systemie 1351 stacji SN/nn. Stwierdzono, że awaryjność głównych elementów wyposażenia stacji nie przekracza 1,5%. Ponad 90% stacji zaliczono do rangi „mało ważna”, a tylko nieco ponad 1% sklasyfikowano jako „strategiczne”.
The paper describes the most important strategies of MV/LV distribution station operation. There are given general ideas of the method for assessment of the importance of the station in a power system. The analysis of failures and importance was performed for 1351 stations. It was found that the failure ratio of main station elements was below 1.5%. The highest value of the failure ratio had MV switches, followed by transformers (approx. 0.7 %). The process of importance assessment was based on the following parameters: the number and power of transformers in a station, the load ratio, a type of the customer of the station, power supply configuration and a type of the station. On this basis over 90% stations were categorized as having “low importance”, while only 1% was found to be “strategic”. The above data suggests changes in the station operation procedures. The currently used TBM strategy should be replaced by the CM strategy. It would lead to lowering the operation costs without significant decrease in the energy supply quality.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 168-171
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System Sterowania i Nadzoru nad pracą sieci przesyłowej w PSE Operator S.A.
Substation Control System for transmission network supervising in Polish Transmission System Operator (PSE Operator S.A.)
Autorzy:
Wójcicki, P.
Powiązania:
https://bibliotekanauki.pl/articles/151420.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
system sterowania i nadzoru
telemechanika
stacja elektroenergetyczna
niezawodność
wymagania techniczne
sterowanie
nadzór techniczny
standard
SCS
substations control system
power substation
asset management
reliability
technical requirements
technical supervising
Opis:
Systemy sterowania i nadzoru (SSiN) wdrażane jako rozbudowane układy telemechaniki są w obiektach Krajowego Systemu Elektroenergetycznego od lat '90 ubiegłego wieku. Potrzeby wynikające z obowiązku zapewnienia bezpieczeństwa energetycznego oraz wysokiej dyspozycyjności sieci determinują szerokie wdrożenie nowoczesnych systemów telemechaniki zapewniających pozyskiwanie informacji i danych niezbędnych do wykonywania zdalnych sterowań i nadzoru. Zastosowane rozwiązania konstrukcyjne i technologiczne dla SSiN gwarantują wysoki poziom dyspozycyjności systemów oraz nadzorowanych i sterowanych obiektów energetycznych. Dla uzyskania wysokiej sprawności układów zdecydowano o powszechnym zastosowaniu standardu IEC 61850, coraz powszechniej stosowanego przez energetykę zawodową na świecie.
A project of Substation Control System (SCS) implementation in power substations of the national HV (220 and 400 kV) power transmission grids results from the main needs of new methods for asset management. The requirements are based on ensuring the transmission system energy safety as well as the high operational reliability and availability of the grid elements. Reliable operational, maintenance and technical information in real time on power substations and power lines gives many possibilities for increase in the level of using the power assets and for the safe remote control of power system elements. System Operator in Poland accepted the international standard IEC 61850 for new implementation of SCS in own HV power substations. Additionally, the system operator defined many own standards for determining the requirements concerning construction, functions, telecommunication and other technical problems for HV power substations and also for SCS components. These standards deal with the main requirements and typical solutions for building and modernisation of power substations. The paper presents the main assumptions and general effects of the project implemented, general technical requirements and the structure of the proposed technical solutions, general organisational conditions for new methods in operation process of power HV substations and the main advantages of this implementation.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 6, 6; 396-399
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of recloser functionality for MV grid automation
Przegląd funkcjonalności reklozerów do celów automatyzacji sieci SN
Autorzy:
Nandzik, P.
Rzepka, P.
Szablicki, M.
Halinka, A.
Powiązania:
https://bibliotekanauki.pl/articles/397495.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
recloser
grid operation control
communication master system
medium voltage grid
distributed power recovery systems
reliability
reklozer
sterowanie ruchem sieciowym
komunikacja z systemem nadrzędnym
sieć średnich napięć
niezawodność
Opis:
Distribution system operators (DSOs) are now undertaking intensive actions aimed at increasing the degree of medium voltage (MV) grid automation. One of the means to accomplish this task are reclosers. The use of these devices enables improved reliability of electricity supplies to recipients by automatic separation of the disturbance-affected grid portion (then – differently than previously – recipients connected to the rest of the grid can be supplied with electricity). In addition, with the appropriate functional connection of these devices, it is possible to develop master systems for grid operation monitoring and control. Therefore, the paper compares the functionality and parameters of reclosers made by selected manufacturers in terms of assessing their suitability for the development of extensive restitutive automation systems.
Operatorzy systemów dystrybucyjnych (OSD) podejmują obecnie intensywne działania mające na celu zwiększenie stopnia automatyzacji sieci średnich napięć (SN). Jednym ze środków umożliwiających realizację tego zadania są reklozery. Zastosowanie tych urządzeń umożliwia poprawę niezawodności dostaw energii elektrycznej do odbiorców poprzez automatyczne wydzielenie fragmentu sieci objętego zakłóceniem (wówczas – odmiennie niż dotychczas – odbiorcy przyłączeni do pozostałej części sieci mogą być zasilani w energię elektryczną). Ponadto, przy odpowiednim powiązaniu funkcjonalnym tych urządzeń, istnieje możliwość konstruowania nadrzędnych systemów nadzoru i sterowania ruchem sieciowym. W związku z tym w artykule porównano funkcjonalność i parametry reklozerów wybranych producentów pod kątem oceny ich przydatności do tworzenia rozbudowanych systemów automatyki restytucyjnej.
Źródło:
Acta Energetica; 2017, 4; 98-104
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Концепция мониторинга и диагностирования электрооборудования тяговых подстанций электрифицированных железных дорог
Koncepcja monitoringu i diagnostyki elektrycznego wyposażenia kolejowych podstacji trakcyjnych
Concept of Monitoring and Diagnosis Electric Fixtures of Railway Substation of Electrified Railways
Autorzy:
Matusevič, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/952268.pdf
Data publikacji:
2015
Wydawca:
Instytut Kolejnictwa
Tematy:
zasilanie trakcyjne
linie kolejowe
monitoring
Smart Grid
podstacja trakcyjna
wyposażenie elektryczne
konserwacja
naprawy
diagnostyka
niezawodność systemu
rzeczywisty stan techniczny
electric power supply
electrified railways
smart grid
railway sub-station
power equipment
technical servicing
repair
diagnosis
reliability
system
condition monitored maintenance
Opis:
W artykule pokazano teoretyczne i metodologiczne podejście w celu zwiększenia jakości i efektywności monitorowania i diagnozowania wyposażenia elektrycznego podstacji trakcyjnych w eksploatacji. W celu zwiększenia niezawodności zasilania linii kolejowych i ograniczenia awaryjności wyposażenia elektrycznego podstacji trakcyjnych, prześledzono doświadczenia spółek energetycznych w technologii sieci inteligentnych Smart Grid. Przeprowadzono także analizę głównych metod monitorowania i diagnozowania urządzeń podstacji trakcyjnych. Proponowana koncepcja monitorowania i diagnostyki elektrycznego wyposażenia podstacji ma na celu poprawę niezawodności sprzętu i jego optymalnej pracy w całym cyklu życia, a także obniżenie kosztów eksploatacji urządzeń energetycznych przez wykorzystanie konserwacji i naprawy rzeczywistego stanu technicznego.
Theoretical approaches and methodological support of the solution the actual scientific and technical problem of quality improvement and monitoring efficiency and electric equipment diagnosing of railroads railway substations while in operation are offered. In order to improve electric power supply reliability and reduce the power equipment fault rate undertook a study experience of the energy companies for high quality problem solution of electric power supply based on the ideology of Smart Grid technologies. Also, the analysis of the monitoring main methods and diagnosing TP devices of electrified railways is carried out. The offered concept of monitoring and diagnosing of electric equipment of railway substations of the electrified railroads is focused on reliability growth of equipment operation and achievement of optimum use it throughout life cycle, and also expenditures lowering on operation of the power equipment due to application of technical servicing and repair on the condition monitored maintenance.
Źródło:
Problemy Kolejnictwa; 2015, 167; 43-49
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies