Tytuł:
Downtime Measurements of Generator-Powered Microgrid During Planned and Unplanned Transfer to Island Mode
Autorzy:
Prokop, Kamil
Bień, Andrzej
Barczentewicz, Szymon
Powiązania:
https://bibliotekanauki.pl/articles/27311940.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
islanding
Smart grid
power grid communication
power quality
distributed computing
Opis:
Growing popularity of distributed generation is drawing special attention to communication technologies in smart power grids. This paper provides a detailed overview of the communication protocols utilized in the modern distributed grid laboratory. It describes both wired and wireless technologies used in Smart Grid and presents the remote operation of switching the subsystem from grid mode to island mode operating under nominal conditions. It shows the duration of power outages during a transfer to island mode with diesel generator running on idle - which simulates planned islanding and diesel generator stationary, which simulates unplanned islanding. Latency between registration of disturbance and executing control command is measured. The results obtained are compared with current legislation. The consequences to the power system that are possible in both scenarios are highlighted. Obtained results and description of the communication technologies can be useful for the design of distributed power grids, island-mode power grids, and Smart Grids, as well as for further research in the area of using combustion fuel generators as a primary power supply in the microgrid.
Źródło:
International Journal of Electronics and Telecommunications; 2023, 69, 3; 493--498
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring sieci elektroenergetycznej w środowisku przemysłowym
Electrical power grid monitoring in industrial environment
Autorzy:
Pędzisz, K.
Powiązania:
https://bibliotekanauki.pl/articles/320284.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
system monitoringu
sieć elektroenergetyczna
jakość energii
monitoring system
power grid
power quality
Opis:
Postępująca automatyzacja procesów produkcyjnych, a także wzrastający stopień skomplikowania systemów technicznych sprawiają, że w wielu przedsiębiorstwach problemem zasadniczym jest zapewnienie ciągłości procesu produkcyjnego oraz optymalnych parametrów energomediów zasilających urządzenia i instalacje technologiczne. Zagadnienie jakości energii elektrycznej i monitorowania jej parametrów nabierają szczególnego znaczenia w zakładach produkcyjnych pracujących w reżimie produkcji ciągłej, jak również w systemie wieloetapowym, gdzie krótkie przerwy w zasilaniu mogą zakłócić pracę maszyn i doprowadzić do zniszczenia operacji zrealizowanych na poprzednich etapach, powodując znaczne straty produkcyjne. W artykule zaprezentowano system monitoringu i nadzoru rozdzielni średniego napięcia, służący do kontroli wewnątrzzakładowej sieci elektroenergetycznej i głównych zasilaczy zakładu przemysłowego. Podstawowe elementy wchodzące w skład systemu to: stacja operatorska i podłączone do niej urządzenia obiektowe, którymi są zabezpieczenia w sieci średnich napięć. W skład systemu wchodzą również analizatory sieci kontrolujące parametry zasilania. Stacja operatorska systemu wyposażona jest w specjalizowane oprogramowanie, które pozwala monitorować sieć, oceniać wydajność jej pracy i optymalizować rozpływy mocy. Dodatkowo obejmuje nadzór poboru mocy i zużycia energii elektrycznej. Jego zaletą jest moduł kontroli parametrów jakości energii elektrycznej i analizy zakłóceń w sieci elektroenergetycznej.
The main problems of many companies are: assuring the continuity of production and the best energy sources which are supplied to technological devices. These problems are caused by the progressive automatization of manufacturing processes and more and more complicated technical systems. Power quality is particularly important in companies where there is a continuous or multistages production. Unexpected disturbances called sags and interruptions may cause lost production and productivity due to eąuipment failures and unexplained shutdowns which can be very costly as well. In fact a huge manufacturing loss can be met by a company. In the paper power monitoring system adapted to medium voltage industrial power grid is presented and discussed. This system can be used in all electrical distribution systems. The system is made up of three main parts: communicating devices, communication interfaces and special software. Mentioned in the article system is the answer to power management needs concerning: the cost, quality and reliability of electrical power.
Źródło:
Elektrotechnika i Elektronika; 2007, 26, 1--2; 61-68
1640-7202
Pojawia się w:
Elektrotechnika i Elektronika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Logistyka identyfikacji i lokalizacji zdarzeń awaryjnych w systemie elektroenergetycznym
Logistics of identification and location of emergency events in the power system
Autorzy:
Gubański, A.
Kostyła, P.
Rezmer, J.
Szymańda, J. M.
Powiązania:
https://bibliotekanauki.pl/articles/376755.pdf
Data publikacji:
2016
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
system elektroenergetyczny
jakość energii elektrycznej
propagacja zaburzeń
logistyka
power grid
power quality
propagation of disturbance
logistics
Opis:
W artykule przedstawiono możliwość identyfikacji zdarzeń awaryjnych występujących w systemie elektroenergetycznym oraz propagacji zaburzeń na podstawie rejestracji synchronicznych w wybranym obszarze sieci. Badania wykorzystują rejestracje wykonane w sieci elektroenergetycznej Tauron Dystrybucja S.A. oraz Tauron Ekoenergia Sp. z o.o. Prezentowane wyniki obejmują wybrane elementy badań w ramach prac podstawowych dotyczących obszarowej oceny jakości energii w rozproszonych sieciach dystrybucyjnych z udziałem energetyki odnawialnej. Obszar badań obejmuje elektrownie wodne o mocach rzędu 1 MW oraz linie WN 110 kV, SN 10/20 kV i odbiorcę nN 0.4 kV. Potwierdzono możliwość skutecznej identyfikacji zdarzeń awaryjnych na podstawie uzyskanych rejestracji w systemie monitorowania działającego od stycznia 2012 r. Analiza umożliwia czasową lokalizację awarii w systemie el-en oraz określanie propagacji zaburzeń. Opracowana procedura monitorowania zaburzeń może stanowić uzupełnienie algorytmów związanych z systemami sieci inteligentnych (smart grid).
The article describes the possibility of identification and distribution of events registered in the power stations of the system belonging to Tauron Distribution SA and Tauron Ekoenergia sp. z o.o. The presented results contain selected elements of basic research on the evaluation of the energy quality monitoring system in the scattered distribution networks. The area of this research includes two hydroelectric plants, each delivering power of the order of 1 MW through 110 kV high voltage and 10/20 kV medium voltage power lines, respectively, as well as a 0.4 kV low voltage end user. The system in question has been monitored since January 2012. From the data obtained, it has been determined that it is possible to quickly identify synchronous events. This makes the temporal analysis of both failure location and disturbance propagation possible. The procedure developed for monitoring the propagation of disturbance may complement the algorithms implemented in smart grids.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2016, 86; 21-31
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grid synchronization and symmetrical components extraction with PLL algorithm for grid connected power electronic converters - a review
Autorzy:
Bobrowska-Rafał, M.
Rafał, K.
Jasiński, M.
Kaźmierkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/200073.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase locked loop PLL
symmetrical component extraction
grid synchronization
grid-connected converter
smart grid
renewable energy sources (RES)
voltage dip
higher harmonics
power quality
Opis:
In this paper, a review of Phase Locked Loop (PLL) algorithms and symmetrical component extraction methods intended for grid-connected power electronic converters are presented. Proposed classification is based on voltage representation in three coordinates: natural (abc), stationary (alfa beta) and rotating coordinates (dq). The three selected algorithms are described in details: Dual Second Order Generalized Integrator (DSOGI-PLL), Dual Virtual Flux – both in stationary coordinates. The third one, in rotating dq coordinates, is Dual Synchronous Reference Frame PLL (DSRF-PLL). A comparison of PLL algorithms is presented. Also, selected experimental results are given to verify practical application of discussed algorithms.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 485-497
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of Proportional-Integral Controllers of Grid-Connected Wind Energy Conversion System Using Grey Wolf Optimizer Based on Artificial Neural Network for Power Quality Improvement
Autorzy:
Alremali, Fathi Abdulmajeed M.
Yaylacı, Ersagun Kürşat
Uluer, İhsan
Powiązania:
https://bibliotekanauki.pl/articles/2201727.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
artificial neural network
grey wolf optimizer
PI controller
grid connection
power quality
wind energy
Opis:
This research presents a combination of artificial neural network (ANN) with the grey wolf optimizer (GWO) to improve the power quality of a grid-connected distributed power generation system (DPGS). To assess the effectiveness of the proposed algorithm, a grid-tied of small-scale wind energy conversion system (WECS) is chosen. The term power quality refers to voltage and frequency regulation, and limited harmonics. Power quality improvement is achieved through the cascaded control system's optimal tuning of three proportional-integral (PI) controllers of the grid-side inverter (GSI). However, because the DPGS model is computationally costly, the Artificial Neural Network (ANN) model is utilized as an alternative model for DPGS. Furthermore, the ANN model is employed in conjunction with the GWO to boost the optimization precision and minimize the execution time of GWO. The considered power system was repetitively simulated to obtain the input-output datasets, which validate and train the ANN model. According to the ANN model's performance evaluation, the correlation coefficient (R) is close to one, while the mean squared error (MSE) is near zero. These findings demonstrate the ANN model's great accuracy in approximating the DPGS model. Using MATLAB/Simulink, the system's performance is evaluated using the optimum values obtained using GWO-ANN for various wind speed profiles. It showed the suggested power quality method’s improved stability, convergence behavior, the effectiveness of the control mechanism, and the robustness of the proposed topology.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 3; 295--305
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zaawansowane systemy monitorowania i sterowania siecią SN i nN podstawą do poprawy jakości zasilania – projekt pilotażowy upgrid
Advanced systems for monitoring and control MV and LV network as a basic element for improve quality of power – pilot project upgrid
Autorzy:
Falkowski, D.
Noske, S.
Powiązania:
https://bibliotekanauki.pl/articles/267127.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
sieci inteligentne
automatyzacja sieci
AMI
smart grid
Upgrid
Horyzont 2020
network automatization
Horizon 2020
power quality
Opis:
Wprowadzona w 2015 roku przez URE regulacja jakościowa sprawia, że kwestia niezawodności zasilania jest priorytetową sprawą dla OSD. Dodatkowo przyłączanie coraz większej ilości mikroźródeł do sieci nN może powodować pogorszenie się jakości energii. W celu sprostania tym wyzwaniom konieczne jest podnoszenie poziomu obserwowalności i kontroli sieci dystrybucyjnej. Integrując stosowane obecnie rozwiązania automatyzacji sieci SN z infrastrukturą AMI możliwe jest osiągnięcie nowej jakości w zakresie pozyskiwanych danych, będące podstawą do wdrażania nowych rozwiązań systemowych. ENERGA-OPERATOR realizuje projekt pilotażowy Upgrid, którego celem jest rozwój narzędzi do kontroli i nadzoru sieci SN oraz nN. W artykule przestawiono informacje nt. opracowanej nowej koncepcji rozwiązań dla stacji SN/nN oraz wdrażanego w ramach projektu Upgrid systemu DMS nN.
Improving the reliability and efficiency of the network is one of the main challenges that DSOs face. Implementation of new technical solutions from Smart Grid area, like Advanced Metering Infrastructure (AMI) or advanced automation of the secondary substation (SS) and LV network, can provide new information about the state of the MV and LV network. As a result, it is possible to build the functionalities that bring a new quality to the network operations and management. ENERGA-OPERATOR SA gathered experience in the field of Smart Grid for several years. After the completion of several smart grid pilot projects in the MV network and deployment of AMI it is time to focus on LV network management and challenges that can arise in the future i.e. high saturation of microgeneration the need for rapid response to failures, large quantity of data from RTUs and smart meters. By integrating existing systems and adding new functionality, it is possible to meet these challenges. The paper will present: the concept of the new solution for secondary substation, the impact of the solution on the grid and using data form AMI and automation to improve power quality.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 50; 23-26
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reparation of voltage disturbance using PR controller-based DVR in Modern power systems
Autorzy:
Danalakshmi, D.
Prathiba, Srividya
Ettappan, M.
Krishna, Mohan D.
Powiązania:
https://bibliotekanauki.pl/articles/1839555.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
smart grid
jakość energii elektrycznej
regulator PI i PR
ewolucja
DVR
współczynnik zawartości harmonicznych
power quality
PI and PR controller
self balanced differential
evolution
dynamic voltage restorer
total harmonic distortion
Opis:
The Smart Grid environment gives more benefits for the consumers, whereas the power quality is one of the challenging factors in the smart grid environment. To protect the system equipment and increase the reliability, different filter technologies are used. Even though, consumers’ expectations towards the power quality are not fulfilled. To overcome these drawbacks and enhance the system reliability, a new Custom Power Devices (CPD) are introduced in the system. Among different CPDs, the Dynamic Voltage Restorer (DVR) is one of the voltage compensating devices that is used to improve the power quality during distortions. When the distortions such as voltage swell and sag occur in the distribution system, the control strategy in the DVR plays a significant role. In this article, the DVR performance using Proportional Integral (PI), Proportional Resonant (PR) controllers are analyzed. A robust optimization algorithm called Self Balanced Differential Evolution (SBDE) is used to find the optimal gain values of the controllers in order to reach the target of global minimum error and obtain fast response. Then, a comparative analysis is performed between different controllers and verified that the performance of PR controller is superior than the other controllers. It has been found that the proposed PR controller strategy reduces the Total Harmonic Distortion (THD) values for all types of faults. The proposed SBDE optimized DVR with PR controller reduces the THD value less than 4% under voltage distoration condition. The DVR topology is validated in MATLAB/SIMULINK in order to detect the disturbance and inject the voltage to compensate the load voltage.
Źródło:
Production Engineering Archives; 2021, 27, 1; 16-29
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies