Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "treatment." wg kryterium: Temat


Tytuł:
Dewatering of conditioned sludge in small wastewater treatment plants
Autorzy:
Wolny, L.
Powiązania:
https://bibliotekanauki.pl/articles/207409.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
wastewater treatment
dewatering
filtration
polyelectrolytes
sewage sludge
sewage treatment
sewage treatment plants
water treatment plants
municipal wastewater treatment plants
wastewater treatment plants
oczyszczanie ścieków
odwadnianie
filtrowanie
polielektrolity
osady ściekowe
oczyszczalnie ścieków komunalnych
oczyszczalnie ścieków
Opis:
Parameters characterizing the dewatering process of sewage sludge in small wastewater treatment plants (WWTPs) have been analyzed. Two municipal wastewater treatment plants of comparable capacity and similar technology of sewage treatment were selected to the analysis. Comparison of dewaterability of unprepared and conditioned sludge was made. During preliminary tests, the capillary suction time (CST) of sludge conditioned with cationic polyelectrolyte was determined. Next, for the optimal doses of selected polyelectrolyte, more detailed technological experiments were conducted such as vacuum filtration and susceptibility to the gravitational thickening. Tested sludge had very low susceptibility to thickening. The final volume of unprepared tested samples after 2 hour thickening was 977.0 cm3, while the initial volume of thickened sludge was 1000 cm3.The lowest value of final hydration for conditioned sludge was 64.0%.
Źródło:
Environment Protection Engineering; 2015, 41, 2; 99-105
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sewage gardens – constructed wetlands for single family households
Autorzy:
Obarska-Pempkowiak, H.
Gajewska, M.
Wojciechowska, E.
Kołecka, K.
Powiązania:
https://bibliotekanauki.pl/articles/208217.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
przydomowa oczyszczalnia hydrofitowa
przydomowe oczyszczalnie
oczyszczanie hydrofitowe
roślinne oczyszczalnie ścieków
domy jednorodzinne
oczyszczanie ścieków
household sewage treatment wetland
household sewage
wetland treatment
treatment wetland (TWs)
wastewater treatment plant
single family
wastewater treatment
Opis:
During the last 30 years the increase of interest in low-cost decentralized and small wastewater treatment plants (WWTP) is observed in Europe. For this purpose, sand filters, stabilization ponds, mini reactors with activated sludge, trickling filters and treatment wetlands are used. Among the listed facilities, treatment wetlands (TWs) offer effective and reliable treatment efficiency, being at the same time low-cost and simple in operation. This is a sustainable treatment technology which does not generate secondary sewage sludge. In the paper, design concept and performance of nine TWs constructed in 2009 for single-family households in Kashubian Lake District is discussed. The treatment efficiency of three different TW configurations is compared. The findings of the study provide a basis for future design and implementation of TWs in agricultural areas.
Źródło:
Environment Protection Engineering; 2015, 41, 4; 71-82
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydrobotaniczne oczyszczalnie ścieków
Autorzy:
Gołąb, M.
Nocoń, W.
Michalski, R.
Powiązania:
https://bibliotekanauki.pl/articles/273982.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
oczyszczanie ścieków
oczyszczalnia ścieków
hydrobotaniczna oczyszczalnia ścieków
system Lemna
wastewater treatment
wastewater treatment plant
hydrobotanic wastewater treatment plant
Lemna-type
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 4; 6-10
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena pracy przydomowych oczyszczalni ścieków BIO-DUO w pierwszych miesiącach eksploatacji
Evaluation sewage treatment plants BIO-DUO in the first months of operation
Autorzy:
Jakubaszek, A.
Stadnik, A.
Powiązania:
https://bibliotekanauki.pl/articles/371857.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
przydomowe oczyszczalnie ścieków
wskaźniki zanieczyszczeń
wastewater treatment
sewage treatment plants
Opis:
W artykule przedstawiono wyniki badań podstawowych wskaźników zanieczyszczeń w ściekach z przydomowych oczyszczalni ścieków BIO-DUO firmy Sotralentz. Obiektami badań były oczyszczalnie zlokalizowane w województwie dolnośląskim na terenie gminy Bardo. Badania prowadzono w pierwszym półroczu eksploatacji obiektów. Analizie poddano ścieki oczyszczone odprowadzane do odbiorników, którymi są studnie chłonne lub rowy melioracyjne. Na podstawie uzyskanych wyników badań wykazano, że w większości przebadanych obiektów już po 4 tygodniach eksploatacji wartości wskaźników zanieczyszczeń w ściekach oczyszczonych nie przekraczały stężeń dopuszczalnych. Część oczyszczalni wymagała dłuższego okresu wypracowania i regulacji ilości powietrza dostarczanego do reaktora. Ponowne badania wykazały poprawę pracy oczyszczalni oraz spełnienie wymagań określonych w Rozporządzeniu Ministra Środowiska.
The article presents the results of the basic indicators of pollutants in sewage from domestic wastewater treatment plants BIO-DUO company Sotralentz. Research sewage treatment facilities were located in the Dolnośląskie Province in the municipality of Bardo. The study was conducted in the first half operation of facilities. We analyzed effluent discharged into the receivers, which are cesspools or drainage ditches. Based on the results of research it has shown that in most studied objects after 4 weeks of life indicator values of pollutants in treated wastewater does not exceed concentration limits. Part of the sewage require a longer period and regulating the amount of air supplied to the reactor. Re study showed improvement in plant operation and fulfillment of requirements specified in the Ordinance of the Minister of the Environment.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2015, 160 (40); 45-55
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effectiveness of Pollutant Removal At the Wastwewater Treatment Plant in Goleniów
Autorzy:
Jakubaszek, Anita
Powiązania:
https://bibliotekanauki.pl/articles/2051690.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
wastewater treatment
modernization
wastewater treatment plant
Wastwewater Treatment Plant in Goleniów
oczyszczanie ścieków
modernizacja
oczyszczalnia ścieków
Oczyszczalnia Ścieków w Goleniowie
Opis:
The article assesses the efficiency of pollutant removal at the sewage treatment plant in Goleniów after modernization of the technological system. The extension and modernization of the existing installation resulted from the need to adapt the treatment plant to accept larger loads of pollutants, improve the parameters of treated sewage discharged to the receiver, and the poor technical condition of the equipment. Before the modernization of the treatment plant, an increase in the loads of COD, BOD5, and periodic total suspended solids in raw sewage was observed as well as a reduction in the efficiency of removing pollutants from the sewage. The efficiency of removing pollutants after modernization was in the range of BOD5 - 94.4 ÷ 99.8%, COD - 89.3 ÷ 98.9%, total suspended solids TSS - 95.3 ÷ 99.7%, total nitrogen - 64.1 ÷ 95.4%, and total phosphorus - 75.4 ÷ 99.4%.
Źródło:
Civil and Environmental Engineering Reports; 2021, 31, 3; 251-264
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania ścieków bytowo-gospodarczych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych
The efficiency of domestic sewage tretment in ground-plant and soil-plant treatment units
Autorzy:
Czyżyk, F.
Pulikowski, K.
Strzelczyk, M.
Pawęska, K.
Powiązania:
https://bibliotekanauki.pl/articles/338757.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnie glebowo-roślinne
oczyszczanie ścieków
reed bed system
soil-plant treatment
wastewater treatment
Opis:
Celem badań prezentowanych w pracy było rozpoznanie zmian efektywności oczyszczania ścieków bytowych w oczyszczalniach gruntowo-roślinnych i glebowo-roślinnych w zależności od czasu i warunków ich eksploatacji. W pracy przedstawiono wyniki badań skuteczności oczyszczania ścieków w złożach gruntowo-trzcinowych, zbudowanych wg systemu Kickutha, oraz oczyszczalni glebowo-roślinnej w początkowym okresie eksploatacji (na 4 obiektach) i po 15 latach (na 2 obiektach). Zaskakujące były zdecydowanie różniące się wyniki, uzyskane w pierwszych latach eksploatacji, z dwóch podobnych złóż gruntowo-trzcinowych, których eksploatację rozpoczęto w tym samym roku. Na jednym skuteczność oczyszczania zwiększała się z upływem czasu, a na drugim wystąpiły objawy braku tlenu w złożu i słabej nitryfikacji azotu, co przejawiało się dużym stężeniem N-NH4 w odpływach z oczyszczalni. Przyczyną tego była błędna lokalizacja oczyszczalni - w miejscu silnie zacienionym, co wpłynęło na bardzo słaby rozwój trzciny i jej systemu korzeniowego, a tym samym na słabe napowietrzanie złoża. Z upływem lat eksploatacji pogarszała się przepuszczalność złóż dwóch badanych oczyszczalni gruntowo-trzcinowych i wystąpiło ich zakolmatowanie, powodowane głównie niedostatecznym oczyszczaniem wstępnym doprowadzanych ścieków. Stwierdzono znacznie wyższy stopień oczyszczania ścieków w oczyszczalni glebowo-roślinnej, zarówno w początkowym okresie eksploatacji, jak i po 15 latach. Uzyskane zmniejszenie głównych wskaźników zanieczyszczenia po 15 latach eksploatacji gruntowo-trzcinowych było następujące (w %): Nog - 47, Pog - 63, BZT5 - 93, ChZTCr - 81, natomiast na oczyszczalni glebowo-roślinnej: Nog - 84, Pog - 99, BZT5 - 95, ChZTCr - 74.
The aim of this study was to trace changes in the efficiency of domestic sewage treatment in soilplant and ground-plant systems in relation to the time and conditions of use. The paper presents results of testing the effectiveness of sewage treatment in ground reed beds constructed according to Kickuth system and in soil-plant treatment units, in the beginning of utilization period (in 4 objects) and after 15 years (in 2 objects). Surprising were the definitely different results obtained during the first years of utilization in two similar reed beds, which started operating in the same year. In one, the efficiency of treatment increased with time and in the other the symptoms of oxygen deficit and weak nitrification were observed in the bed which manifested itself in high N-NH4 concentrations in the outflow from the treatment unit. The reason was in faulty location of the treatment unit in an intensely shaded place resulting in poor development of reed and its root-rhizome system and, consequently, in poor aeration of the bed. In the two examined ground reed treatment units, the beds lost their permeability and became silted with time due mainly to insufficient primary sewage treatment. The soil-plant treatment unit showed considerably higher degree of sewage purification, both during the initial period of utilization and after 15 years. In ground reed beds, after 15 years of their utilization, the reduction of main pollutants was (in %): Ntot - 47, P - 63, BOD - 93, CODCr - 81, whereas in soil-plant treatment units it was: Ntot - 84, P - 99, BOD - 95, CODCr - 74.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 4; 97-108
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektywności procesu koagulacji ścieków włókienniczych w warunkach przemysłowych
Effectiveness of textile wastewater coagulation treatment under industrial conditions assessment
Autorzy:
Bilińska, L.
Biliński, K.
Ledakowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/2073257.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ścieki włókiennicze
oczyszczanie ścieków
koagulacja
textile wastewater
wastewater treatment
coagulation-flocculation treatment system
Opis:
W pracy przedstawiono wyniki oczyszczania strumienia ścieków włókienniczych o wysokim stężeniu zanieczyszczeń za pomocą koagulacji. Na podstawie wskaźników charakteryzujących oczyszczone w skali laboratoryjnej ścieki (pH, indeksu osadu, temperatury, stężenia chlorków, ChZT, BZT) oceniono efektywność działania badanych koagulantów i flokulantów. Wybrano najlepszą parę środków. Efekty oczyszczania potwierdzono w skali przemysłowej. Udało się osiągnąć parametry oczyszczonych ścieków pozwalające na zrzut do miejskiej sieci kanalizacyjnej.
The paper presents the results of "high-loaded" wastewater stream coagulation-flocculation treatment. On the basic of indicators that characterized treatedin labolatory scale wastewater (pH, sludge index, temperature, chlorides, COD and BOD) the effectiveness of tasted coagulants and flocculants was assessed. The best coagulant-flocculant pair was chosen. Treatment effects were confirmed on an industrial scale. Limiting emission factors were achieved so dumping into municipal sewer was possible.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 4; 143--145
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Denitrifying phosphorus accumulating organisms enrichment and their characteristics in a denitrifying enhanced biological phosphorus removal system
Autorzy:
Zou, H.
Wang, Y.
Powiązania:
https://bibliotekanauki.pl/articles/206936.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biological water treatment
wastewater treatment
nitrogen
phosphorus
biologiczne uzdatnianie wody
oczyszczanie ścieków
azot
fosfor
Opis:
Denitrifying phosphorus accumulating organisms (DPAOs) play an important role in simultane-ous removal denitrifying nitrogen (N) and phosphorus (P). Their enrichment and characteristics were investigated. A denitrifying EBPR reactor, performing continuous anaerobic/anoxic conditions, was used to enrich DPAOs in this study. Through 60 days operation, DPAOs was successfully cultivated in the denitrifying EBPR system and P concentration in the effluent was stable and low with less than 0.5 mg/dm3. Energy dispersive spectroscopy (EDS) analysis showed that P content in anoxic end sludge gradually increased with enrichment operation, which accounted for 2.9, 4.7, 6.2, and 7.9 wt. % in sludge samples at day 0 (i.e., seed sludge), and days 20, 40 and 60, respectively. Based on the batch test, a significant positive correlation was found between COD consumption and P release in anaerobic conditions and between nitrogen removal and phosphorus uptake in anoxic conditions. Furthermore, in anaerobic conditions, the P release rate was 4.2 mg P/(g MLSSh) being higher than the P uptake rate (2.8 mg P/(g MLSS h)) in anoxic conditions. Despite this, total anaerobic P release (8.5 mg P/(g MLSS)) was lower than anoxic P uptake total amount (11.2 mg P/(g MLSS)), implying an excess P uptake in anoxic environment. One whole cycle displayed the obviously denitrifying simultaneous nitrogen and phosphorus removal with more than 95% removal efficiencies in the denitrifying EBPR system.
Źródło:
Environment Protection Engineering; 2017, 43, 3; 225-237
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania ścieków w przydomowej hybrydowej oczyszczalni hydrofitowo-biologicznej
The efficiency of wastewater treatment with the household hybrid (biological-constructed wetland) wastewater treatment plant
Autorzy:
Bergier, T.
Włodyka-Bergier, A.
Powiązania:
https://bibliotekanauki.pl/articles/339038.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnie hydrofitowe
oczyszczanie ścieków
przydomowe oczyszczalnie
constructed wetlands
household wastewater treatment plant
wastewater treatment
Opis:
W artykule przedstawiono wyniki badań nad skutecznością usuwania zanieczyszczeń w przydomowej oczyszczalni ścieków komunalnych firmy Enko, zainstalowanej przy Urzędzie Gminy w Zawoi. Badaniom poddano ścieki surowe, ścieki po wstępnym oczyszczeniu i ścieki oczyszczone. Próbki pobierano co miesiąc, w okresie od listopada 2010 r. do czerwca 2011 r. Przeanalizowano zdolność usuwania w oczyszczalni Enkosystem substancji rozpuszczonych w postaci jonów (przewodność elektryczna właściwa), zawiesiny ogólnej, ogólnego węgla organicznego, BZT5, azotu ogólnego i fosforu ogólnego. Na podstawie uzyskanych wyników stwierdzono dużą, dochodzącą aż do 99%, skuteczność usuwania związków organicznych podatnych na biochemiczny rozkład (BZT5). Również dużą skuteczność usuwania zanieczyszczeń zaobserwowano dla zawiesiny ogólnej - od 74 do 95%. Ogólny węgiel organiczny również był usuwany ze stosunkowo dużą skutecznością (30-81%). Średnia skuteczność usuwania substancji rozpuszczonych w postaci jonów (mierzonych jako przewodność elektryczna właściwa) wynosiła 28%, natomiast fosforu ogólnego 41%. Najgorzej oczyszczalnia Enkosystem usuwała związki azotu - średnio o 27%. Oczyszczalnia Enkosystem pracowała prawidłowo, a wartości badanych wskaźników w zasadzie nie przekraczały wartości dopuszczalnych, zdefiniowanych w polskich przepisach prawnych.
The paper presents results of a study on the efficiency of a household hybrid wastewater treatment plant (WWTP) made by the Enko company, installed for the Town Hall in Zawoja. Samples of raw, pre-treated and treated sewage were analysed. The samples were taken every month, since November 2010 till June 2011. The following parameters were analysed: electrolytic conductivity, suspended solids, total organic carbon, BOD5, total nitrogen and total phosphorus. A high BOD removal efficiency of up to 99% was observed. Suspended solids were also removed with a high efficiency between 74% and 95%. Total organic carbon was removed with a relatively high efficiency (30-81%). The average removal efficiency for electric conductivity was 28%, and 41% for total phosphorus. The worst effects were noted for total nitrogen, the average removal efficiency of which was 27%. Enkosystem WWTP was characterized by proper performance, the values of analysed parameters did not in general exceed the standards defined by Polish legal regulations.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 1; 25-36
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność pracy oczyszczalni ścieków w Hajnówce i propozycja jej modernizacji
Effectiveness of wastewater treatment plants in Hajnówka and its modernization proposal
Autorzy:
Bartkowska, I.
Dzienis, L.
Wawrentowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/401024.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
oczyszczanie ścieków
unieszkodliwianie osadów ściekowych
projektowanie oczyszczalni
autotermiczna termofilna stabilizacja
sewage treatment
sewage sludge treatment
designing sewage treatment plant
Autoheated Thermophilic Aerobic Digestion
Opis:
W artykule przedstawiono charakterystykę dopływających ścieków surowych oraz ścieków oczyszczonych w oczyszczalni w Hajnówce. Dokonana analiza efektywności pracy przedmiotowej oczyszczalni stała się podstawą do zaprojektowania jej rozbudowy. W pracy przedstawiono opis aktualnej technologii oczyszczania ścieków oraz stan gospodarki osadowej. Przedstawiony został także zaproponowany zakres rozbudowy, który jest wynikiem wcześniej przeprowadzonych analiz wyników badań z lat 2003-2010 oraz wizji lokalnych.
The article presents characteristics of untreated sewage flowing into the sewage treatment plant in Hajnówka, as well as characteristics of treated sewage. An analysis of the sewage treatment plant operation efficiency has become the basis for development design for the plant. The paper describes present sewage treatment technology and state of sludge management. The article also presents a proposed design for development which results from previous research analyses made in 2003-2010 and from site inspections.
Źródło:
Inżynieria Ekologiczna; 2011, 24; 226-235
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka chalcedonitu ze złoża Teofilów pod kątem możliwości wykorzystania w technologii uzdatniania wody i oczyszczania ścieków
Characteristics of chalcedonite from Teofilów deposit for possible use in technology of water and wastewater treatment
Autorzy:
Michel, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/216553.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
chalcedonit
skała krzemionkowa
uzdatnianie wody
oczyszczanie ścieków
chalcedonite
siliceous rock
water treatment
wastewater treatment
Opis:
Chalcedonit jest to krzemionkowa skała osadowa, która ze względu na bardzo niewielki obszar występowania zalicza się do skał unikalnych. Występuje w złożach Dęborzynka, Gapinin, Lubocz i Teofilów na Wysoczyźnie Rawskiej w rejonie Tomaszowa Mazowieckiego i Nowego Miasta. Złoże Teofilów jako jedyne jest udokumentowane i obecnie eksploatowane. Powierzchnia złoża wynosi 577 437 m2, a jego zasoby geologiczne zostały określone na 21,587 ź 106 kg (21 587,0 tys. ton). Głównym składnikiem skały jest chalcedon (69,0-96,6% obj.), natomiast kwarc, opal, wodorotlenki żelaza, piryt, związki manganu oraz minerały ilaste występują w niewielkich ilościach. Powierzchnia właściwa chalcedonitu jest stosunkowo mała i została określona na 3-6 m2/g. Chalcedonit posiada strukturę mezoporowatą o stosunkowo dużej jednorodności porów, których całkowita objętość wynosi 0,03-0,04 cm3/g. Z racji niewielkiego rozprzestrzenienia chalcedonit jest skałą unikalną, która posiada właściwości wielosurowcowe. Wykazuje przydatność w wytwarzaniu tworzywa perlitopodobnego, krystobalitu, wollastonitu oraz mullitu. Uznany został za dobry surowiec do produkcji past, proszków do szorowania, nasypowych narzędzi ściernych oraz dobry wypełniacz do produkcji farb, lakierów, emalii, kitów i szpachlówek. Ze względu na mezoporowatą strukturę oraz rozbudowaną zewnętrzną powierzchnię ziaren chalcedonit może znaleźć zastosowanie w technologii uzdatniania wody głównie jako skuteczny materiał filtracyjny. Wysoka przydatność złoża chalcedonitowego do odżelaziania i odmanganiania wody przejawia się głównie występowaniem w filtrze strefy odżelaziania o małej wysokości, stosunkowo niedługim czasem wpracowania do efektywnego usuwania manganu(II), a także dobrymi właściwościami hydraulicznymi materiału, pozwalającymi na uzyskanie dużych pojemności masowych na filtrze oraz długich cykli filtracyjnych. Chalcedonit jest bardzo dobrym nośnikiem tlenków manganu, a modyfikacja jego powierzchni prowadzi do wytworzenia złoża aktywnego chemicznie, które umożliwia usuwanie manganu(II) z wody z wysoką efektywnością bez konieczności wpracowania filtru. Na złożu chalcedonitowym zachodzi skuteczne usuwanie azotu amonowego z wody w procesie nitryfikacji oraz oczyszczanie ścieków komunalnych. Chalcedonit również może być brany pod uwagę jako sorbent do usuwania rozlewów olejowych.
Chalcedonite is a diatomaceous sedimentary rock, which, on account of a very small occurrence area, is included into a group of unique rocks. It occurs at Dęborzynka, Gapinin, Lubocz and Teofilów deposits, located on the Rawska Plateau in the region of Tomaszów Mazowiecki and Nowe Miasto. The deposit in Teofilów is the only documented one and it is now being exploited. The surface of this deposit is 577 437 m2 and its geological resources were determined to be 21.587 - 106 kg (21 587.0 thousand tones). The main component of this rock is chalcedon (69.0-96.6 vol.%), however quartz, opal, iron hydroxides, pyrite, manganese compounds and clay minerals occur in small quantities. The active surface of chalcedonite is relatively small and it was determined as 3-6 m2/g. Chalcedonite had a mesoporous structure of a significantly high pore homogeneity, and the total volume of these pores was 0.03-0.04 cm3/g. On account of its small spatial distribution chalcedonite is a unique rock, which has multi-resource properties. It is useful for manufacturing perlite-like material, crystobalite, wollastonite and mullite. It was also found to be a valuable raw material for the production of pastes, scouring powders, grinder tools and also as good filler for the production of : paints, varnishes, enamel ware, lute and putty materials. Because of its mesoporous structure and due to extended outer surface of the grains, chalcedonite is utilized in water treatment technology, mostly as an effective filtration material. A high usefulness of chalcedonite bed for manganese and iron removal from water shows mostly the presence of a low height of iron removal zone in the filter, and it is also manifested by a relatively short time of introduction into effective manganese(II) removal, as well as by good hydraulic properties of the material, which enable to achieve high mass capacities of the filter and to reach long filtration cycles. Chalcedonit is a very good carrier of manganese oxides and its surface modification of leads to the creation of chemically active bed, which enables removal of manganese(II) from water with high efficiency and without the introduction process. Chalcedonite bed effective removes of ammonia nitrogen from the water in the process of nitrification and waste water treatment. Chalcedonite can be also taken into account as a sorbent for the removal of oil spills.
Źródło:
Gospodarka Surowcami Mineralnymi; 2011, 27, 1; 49-67
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza procesu oczyszczania ścieków poprodukcyjnych w zakładzie SAPA Aluminium Trzcianka
Analysis of post-production wastewater treatment process in the SAPA Aluminium Trzcianka plant
Autorzy:
Ochowiak, M.
Sadowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/2071667.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
oczyszczanie ścieków
anodowanie
wastewater treatment
anodizing
Opis:
W pracy przedstawiono wyniki badań doświadczalnych procesu oczysz-czania ścieków poprodukcyjnych w dziale anodowania zakładu SAPA Aluminium. W pracy wykonano szereg badań w celu ustalenia odpo-wiedniego czasu neutralizacji strumienia ścieków, a następnie wpływu różnych flokulantów na proces sedymentacji oraz na zawartość siarcza-nów w ściekach. Na podstawie wyników badań doświadczalnych sformułowano warunki zastosowania dostępnych surowców odpadowych, aby spełniały one w sposób stabilny normy ochrony środowiska zapisane w pozwoleniu wodno-prawnym.
The experimental results of post-production wastewater treatment process in the anodizing department of SAPA Aluminum plant are presented. Several tests for the determination of appropriate neutralization time of wastewater stream were carried out in the study. An influence of different flocculants on sedimentation process and a content of sulfates in wastewater were also established. The conditions of using available waste materials, satisfying stable environmental standards according to the license related to the water status permission, were formulated on the experimental bases.
Źródło:
Inżynieria i Aparatura Chemiczna; 2012, 3; 65-67
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza kosztów funkcjonowania przydomowych oczyszczalni ścieków
Analysis of Operating Costs of Domestic Sewage Treatment Plants
Autorzy:
Nowak, R.
Wawryca, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818125.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
przydomowe oczyszczalnie ścieków
ocena ekonomiczna
wastewater treatment
domestic sewage treatment plants
economic analysis
Opis:
The economics aspects of the operation of household wastewater treatment plants are discussed in the paper. Three selected individual wastewater treatment systems offered by HABA are presented, such as (1) system with drainage tunnel (HABA DT), (2) treatment plant of SBR type (HABA SBR PRIMO) and (3) constructed wetland wastewater treatment plant (HABA ORS). In the work the analytical procedures for determining the costs are presented. Next, a comparative economics analysis of these systems is carried out. The level of annual costs as well as unit costs of wastewater disposal and treatment are determined for these systems. The annual unit cost in presented small sewage treatment facilities ranged from 4.83 to 6.00 zł per m3. The calculations showed that the lowest annual cost of wastewater treatment is characterized by a system with drainage tunnel. Of the three systems included in the work of the highest costs of wastewater treatment plant generates system HABA ORS.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 680-691
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zintegrowana chemiczno-biologiczna oczyszczalnia ścieków włókienniczych
Integrated chemical-biological textile sewage treatment plant
Autorzy:
Bilińska, L.
Bemska, J.
Biliński, K.
Ledakowicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/2071692.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ścieki włókiennicze
oczyszczanie ścieków
zamykanie obiegów wody
textile wastewater
wastewater treatment
water reuse
effluent treatment plant
Opis:
W pracy przedstawiono chemiczno-biologiczną oczyszczalnię ścieków włókienniczych pracującą w jednym z zakładów włókienniczych okręgu łódzkiego. Szczegółowo opisano poszczególne etapy oczyszczania i przybliżono związane z nimi rozwiązania instalacyjne. Scharakteryzowano także ścieki chodzące z farbiarni. W wyniku pracy instalacji uzyskano 86% redukcji ZT, 52% redukcji azotu, 50% redukcji OW i 90% redukcji OWO. Dzięki temu udało się zawrócić oczyszczoną wodę do procesów produkcyjnych.
The paper presents the chemical-biological textile wastewater treatment plant working in one of textile companies in the district of Lodz. The subsequent stages of purification in reference to installation design arc described. The effluent from the dye house is also characterized. As a result of the treatment 86% COD removal, 52% nitrogen removal, 50% TC removal and also 90% TOC removal were achieved. Thanks to that, the treated water was reused in the production processes.
Źródło:
Inżynieria i Aparatura Chemiczna; 2012, 4; 95-97
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba oceny możliwości wykorzystania osadów z procesów klarowania wody do strącania związków fosforu w oczyszczalniach ścieków komunalnych
An attempt at assessment of possibilities for utilization of sludge produced during water clarification for phosphorus precipitation in municipal wastewater treatment plants
Autorzy:
Balcerzak, W.
Łuszczek, B.
Powiązania:
https://bibliotekanauki.pl/articles/236614.pdf
Data publikacji:
2015
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
osady z oczyszczania wody
koagulanty
oczyszczanie ścieków
usuwanie fosforu
water treatment sludge
coagulants
wastewater treatment
phosphorus removal
Opis:
Przedstawiono wyniki badań laboratoryjnych mających na celu ocenę możliwości zagospodarowania osadów powstających w zakładach wodociągowych w oczyszczalniach ścieków komunalnych. W tym celu wykonano analizę składu osadów pochodzących z układów oczyszczania wód powierzchniowych w Krakowie, z uwzględnieniem specyfiki osadów pokoagulacyjnych i osadów z wód popłucznych. Próbki tych osadów wykorzystano w testach laboratoryjnych do strącania związków fosforu w ściekach komunalnych i przefermentowanych osadach ściekowych pochodzących z krakowskich oczyszczalni. Wyznaczone dawki badanych osadów wskazują na znacznie większe możliwości praktycznego wykorzystania osadów pokoagulacyjnych niż osadów z wód popłucznych. Uzyskane w tym zakresie rezultaty były korzystne zwłaszcza w przypadku ścieków komunalnych i wskazują na możliwość ograniczenia zużycia klasycznych koagulantów stosowanych do strącania związków fosforu. W badaniach stwierdzono także usuwanie siarczków ze ścieków. Uzyskane wyniki wskazują na celowość rozważenia możliwości wykorzystania osadów z klarowania wody zarówno w samych oczyszczalniach ścieków, jak i przez ich wprowadzenie bezpośrednio do strumienia ścieków w sieci kanalizacyjnej. Dalsze prace w tym zakresie, oprócz pogłębienia wiedzy o mechanizmach badanego procesu, powinny koncentrować się na ocenie ewentualnych negatywnych skutków związanych na przykład ze zwiększeniem masy osadów kierowanych do dalszej przeróbki, a także na ocenie aspektów ekonomicznych i eksploatacyjnych tego procesu.
The results of laboratory studies aimed at an assessment of possibilities for utilization of water treatment sludge produced in municipal plants were presented. For this purpose, content analysis was performed for the sludge coming from surface water treatment systems of Krakow, taking account of post-coagulation sludge and filter backwash sludge specifics. The sludge samples were used in the laboratory tests for phosphorus precipitation in municipal sewage and digested sewage sludge from Krakow treatment plants. The amounts of sludge tested indicated much wider possibilities for management of the post-coagulation compared to the backwash sludge. The results were clearly beneficial especially in case of the municipal sludge and pointed to a possible reduction in the amount of commercial coagulants applied to phosphorus precipitation. Additionally, sulfide removal from the sludge was noted. The study results indicate that it is purposeful to consider the possibility of utilization of sludge from water clarification, both in treatment plants alone and by introducing it directly into the sludge stream in a sewer system. Further studies should, beside extending the knowledge on the mechanisms of studied processes, focus on the evaluation of potential adverse effects related to e.g. increase in the amount of sludge directed for further processing as well as on the assessment of economic and operating aspects of the process.
Źródło:
Ochrona Środowiska; 2015, 37, 3; 57-60
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies