Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kaczmarczyk, E" wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Experimental investigation on a rotodynamic pump operating in the cogeneration system with a low-boiling working medium
Autorzy:
Kaczmarczyk, T.
Żywica, G.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/175328.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
organic rankine cycle
micro-CHP
rotodynamic peripheral pump
low-boiling medium
HFE7100
Opis:
The article presents the research carried out on the circulating rotodynamic pump (peripheral pump) operating in the organic Rankine cycle with or without regeneration. The low-boiling solvent HFE7100 was used as the working fluid. Its boiling point is around 61 ◦C at atmospheric pressure. An expansion valve, which simulated the operation of an expansion machine, was used to load the tested pump. The flow characteristics were given for the working media: a solution of glycol and HFE7100 in the condenser, thermal oil and HFE7100 in the evaporator and HFE7100 in the regenerator. The research results concerning the PK70 pump operating in an ORC cycle are reported for the HFE7100 temperature range 15-60 ◦C and the dynamic viscosity range of 0.132 to 0.66 mPas. The maximum flow rate and pressure of the pump during its operation in the ORC system were assessed. The analysis of the results demonstrates that the maximum efficiencies of the pump operating with or without regeneration were 44% and slightly below 37%, respectively. The impact of the selected physicochemical parameters of the working mediums on the pressure drops occurring in the ORC cogeneration installation was discussed. Based on the research conducted and the measurement results, the possibility to apply a PK70 unit as a circulating pump for the working medium in an ORC cycle was checked.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 134; 63-87
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermographic investigation of the cogenerative ORC system with low-boiling medium
Badania termowizyjne układu kogeneracyjnego ORC z czynnikiem niskowrzącym
Autorzy:
Kaczmarczyk, T. Z.
Żywica, G.
Ihnatowicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/329692.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
organic Rankine cycle
low-boiling medium
thermographic
obieg organiczny Rankine’a
czynnik niskowrzący
termografia
Opis:
The paper presents the results of experimental investigations of the ORC system equipped with the expansion valve simulating microturbine operation. The aim of the research was to verify the correct functioning of the installation components and to access the technical condition of the thermal insulation in the heating and cooling mode with regard to the design assumptions. The research was conducted for different values of medium flow rates. The images were acquired using the thermal imaging camera FLIR E50, which is equipped with a specialized software. On the basis of the experimental results, the heat losses have been estimated, together with the places which were the major source of loss (the so-called thermal bridges). It was shown experimentally that the application of a thermal imaging camera can constitute a simple and fast thermal diagnostics method for installations of this type.
W pracy przedstawiono wyniki badań eksperymentalnych układu ORC z zaworem rozprężnym symulującym pracę mikroturbiny. Badania miały na celu sprawdzenie poprawności działania podzespołów instalacji oraz ocenę stanu technicznego izolacji termicznej podczas procesów grzania, chłodzenia i regeneracji w stosunku do założeń projektowych. Badania przeprowadzono dla wybranych natężeń przepływów mediów roboczych. W badaniach wykorzystano kamerę termowizyjną FLIR E50 wraz ze specjalistycznym oprogramowaniem. Na podstawie wyników badań oszacowano straty ciepła instalacji oraz określono miejsca, w których występowały największe straty (tzw. mostki termiczne). Wykazano, że zastosowanie kamery termowizyjnej może być szybką i prostą metodą diagnostyki termicznej tego typu instalacji energetycznych.
Źródło:
Diagnostyka; 2015, 16, 3; 25-32
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies