Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Lentka, G." wg kryterium: Wszystkie pola


Wyświetlanie 1-6 z 6
Tytuł:
A family of new generation miniaturized impedance analyzers for technical object diagnostics
Autorzy:
Hoja, J.
Lentka, G.
Powiązania:
https://bibliotekanauki.pl/articles/220894.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
technical object diagnostics
impedance spectroscopy
impedance analyzer
Opis:
The paper presents the family of three analyzers allowing to measure impedance in the range of 10 Ω<|Zx|<10 GΩ in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzer family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of an impedance measurement method based on digital signal processing (DSP). The miniaturization and other above-mentioned features of the analyzers were obtained thanks to the use of the newest generation of large-scale integration chips: e.g. "system on a chip" microsystems (AD5933), 32-bit AVR32-family microcontrollers and specialized modules for wireless communication using the ZigBee standard. When comparing metrological parameters, the developed instrumentation can equal portable analyzers offered by top worldwide manufacturers (Gamry, Ivium) but outperforms them on smaller dimensions, weight, a few times lower price and the possibility to work in a distributed telemetric network. All analyzer versions are able to be put into medium-volume production.
Źródło:
Metrology and Measurement Systems; 2013, 20, 1; 43-52
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analizator do spektroskopii wysokoimpedancyjnej z wykorzystaniem CPS
High impedance spectroscopy analyzer using DSP
Autorzy:
Hoja, J.
Lentka, G.
Powiązania:
https://bibliotekanauki.pl/articles/153824.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar impedancji
spektroskopia impedancyjna
cyfrowe przetwarzanie sygnałów
impedance measurement
impedance spectroscopy
digital signal processing
Opis:
W artykule przedstawiono opracowany i wdrożony do produkcji seryjnej analizator do spektroskopii wysokoimpedancyjnej. Dzięki zastosowaniu obwodu wejściowego w postaci sondy pomiarowej (2 i 3 zaciskowej) analizator umożliwia pomiary w zakresie 100 Ω < |Zx| < 100 GΩ. Do wyznaczania składowych ortogonalnych sygnałów pomiarowych wykorzystano technikę cyfrowego przetwarzania sygnałów. Pozwoliła ona na pomiary w szerokim zakresie częstotliwości od bardzo niskich 100 ΜHz do 1 MHz. Analiza rzeczywistych parametrów sond, umożliwiła wyznaczenie zależności korygujących wyniki pomiaru, które zaimplementowane w oprogramowaniu analizatora, zwiększyły dokładność pomiaru impedancji.
The paper presents the developed high impedance spectroscopy analyzer which was putted into production. The analyzer allows to measure in the range of 100Ω < |Zx| < 100 GΩ thanks to the usage of the input circuitry in form of the measurement probe (2 and 3 terminal). The digital signal processing technique was used to determine orthogonal parts of the measurement signals. This allows measuring in a wide frequency range from very low 100 ΜHz up to 1 MHz. The analysis of the real-life parameters of the probes made possible evaluation of correction formulas which were implemented in analyzer software and increased accuracy of the impedance measurement.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 3, 3; 102-105
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System do bezprzewodowego monitorowania jakości powłok antykorozyjnych obiektów trudnodostępnych
System for wireless monitoring of quality of anticorrosion coatings on objects difficult-to-reach
Autorzy:
Hoja, J.
Lentka, G.
Powiązania:
https://bibliotekanauki.pl/articles/157556.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spektroskopia impedancyjna
analizator impedancji
telemetria bezprzewodowa
impedance spectroscopy
impedance analyzer
wireless communication
Opis:
W artykule przedstawiono zminiaturyzowany analizator impedancji przeznaczony do spektroskopii impedancyjnej powłok antykorozyjnych obiektów trudnodostępnych znajdujących się w terenie (np. na stalowych konstrukcjach mostu). Przewidziano jego pracę w systemie z komunikacją bezprzewodową opartą na standardzie Bluetooth, w odległości do 100 m od komputera sterującego. Realizuje on pomiary impedancji w zakresie 10 Ω |Zx| 10 G Ω na częstotliwości pomiarowej z przedziału 0,01Hz 100 kHz. W konstrukcji analizatora zastosowano oryginalne rozwiązanie wykorzystujące dwa specjalizowane mikrosystemy AD5933. Błąd względny pomiaru modułu impedancji mieści się w przedziale š1 %, a bezwzględny argumentu š1°.
The paper presents a miniaturised impedance analyzer for impedance spectroscopy of anticorrosion coatings on objects difficult-to-reach located directly in the field (e.g. on the steel construction of the bridge). The analyzer is designed to be used in a system with wireless communication based on the Bluetooth standard on the distance up to 100 m from a controlling computer. It measures impedance in a range of 10 Ω |Zx| 10 G Ω at the measurement frequency in a range of 0,01Hz 100 (10 frequencies in each decade). The analyzer construction is based on original solution using two specialized microsystems (SoC) AD5933 eliminating the need of calibration measurement which is necessary in the configuration proposed by the manufacturer. The tests of the realized analyzer prototype were performed. To do this, the reference RC two-terminal network of configuration and component values representing typical equivalent circuit of the anticorrosion coating in the early stage of exploitation was used. The relative error of the impedance modulus measurement is in the range of š1 %, whereas the impedance argument absolute error is in the range of š1°. The important advantage of the proposed solution based on SoC is reduction of power consumption down to ca. 0,7 W, which is very profitable in case of the impedance analyzer designed to work directly in the field.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 9, 9; 1100-1103
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fast high-impedance spectroscopy method using sinc signal excitation
Autorzy:
Kowalewski, M.
Lentka, G.
Powiązania:
https://bibliotekanauki.pl/articles/220740.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
impedance spectroscopy
sinc signal
Fourier transform
impedance analyzer
Opis:
In this paper the method of fast impedance spectroscopy of technical objects with high impedance (|Zx| ≥ 1 GΩ) is evaluated by means of simulation and a practical experiment. The method is based on excitation of an object with a sinc signal and sampling the response signals proportional to current flowing through and voltage across the measured impedance. The object’s impedance spectrum is obtained with the use of continuous Fourier transform on the basis of linear approximations between samples in two acquisition sections, connected with the duration of the sinc signal. The method is first evaluated in MATLAB by means of simulation. An influence of the sinc signal duration and the number of samples on impedance modulus and argument measurement errors is explored. The method is then practically verified in a constructed laboratory impedance spectroscopy measurement system. The obtained acceleration of impedance spectroscopy in the low frequency range (below 1 Hz) and the decrease of the number of acquired samples enable to recommend the worked out method for implementation in portable impedance analyzers destined for operation in the field.
Źródło:
Metrology and Measurement Systems; 2013, 20, 4; 645-654
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przenośny analizator impedancji z detektorem fazoczułym
Portable impedance analyzer using phase-sensitive detector
Autorzy:
Hoja, J.
Lentka, G.
Powiązania:
https://bibliotekanauki.pl/articles/157876.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spektroskopia impedancyjna
analizator impedancji
detektor fazoczuły
impedance spectroscopy
impedance analyzer
phase sensitive detector
Opis:
W artykule przedstawiono prototyp analizatora impedancji, w którym zastosowano dwa mikrosystemy AD5933 do wydzielania składowych ortogonalnych sygnałów pomiarowych w zakresie częstotliwości od 0,01 Hz do 1 kHz i detektory fazoczułe dla częstotliwości z przedziału 1 kHz - 100 kHz. Przyjęte rozwiązanie pozwoliło wyeliminować błędy pomiaru argumentu impedancji wprowadzane przez AD5933 w górnym zakresie częstotliwości. Uzyskany błąd względny pomiaru modułu impedancji mieści się w przedziale š1%, a bezwzględny argumentu š1° w całym zakresie częstotliwości.
The paper presents a prototype of an impedance analyzer in which two AD5933 microsystems (Fig. 1) for determination of measurement signal orthogonal parts in the frequency range from 0,01 Hz up to 1 kHz and phase-sensitive detectors for the frequency range 1 kHz ? 100 kHz (Fig. 2) are employed. The phase-sensitive detectors (Fig. 3) were realized using operational amplifiers (AD8065) whose gain was changed from -k to +k and vice-versa, depending on the state (shorted or open) of switches (ADG451) driven by the reference signal. Separate generators AD9833 were used for generation of the excitation signal of the measured impedance and the reference signal. The generators were synchronized by means of the common signal used also by the phase-sensitive detectors. The assumed solution allowed eliminating the impedance argument errors caused by AD5933 in the high frequency range (Fig. 5), while simultaneously minimizing the time required for impedance spectroscopy of the object under test. The relative error of the impedance modulus measurement is in the range of š1%, and the absolute error of the impedance argument is in the range of š1° (Fig. 4).
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 9, 9; 761-763
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Woltomierz wektorowy z wykorzystaniem DFT na bazie układu FPGA dla analizatora spektroskopii impedancyjnej
A vector voltmeter using DFT based on the FPGA chip for the impedance spectroscopy analyzer
Autorzy:
Lentka, G.
Kościński, P. A.
Smużyński, K. D.
Powiązania:
https://bibliotekanauki.pl/articles/154373.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
spektroskopia impedancyjna
pomiary impedancji
impedance spectroscopy
impedance measurement
Opis:
W pracy zaproponowano i przetestowano nową koncepcję woltomierza wektorowego z wykorzystaniem cyfrowego przetwarzania sygnałów. Obliczenia prowadzone są sukcesywnie z akwizycją próbek sygnałów pomiarowych, bez gromadzenia ich w pamięci, przy zachowaniu wysokiej częstotliwości próbkowania. Wymaganej mocy obliczeniowej dostarcza układ FPGA. Do obliczania transformaty użyto pamięci wzorca sinusa umieszczonej w układzie FPGA oraz 4 identycznych bloków pracujących równolegle: mnożnika i akumulatora.
In the paper, a new concept of a vector voltmeter for the impedance spectroscopy analyzer is proposed. The voltmeter uses the digital signals processing method for determination of orthogonal parts of measurement signals. The Discrete Fourier Transform calculations are performed “on-the-fly”, successively with acquisition of measurement signals samples, without the need of storing samples in a memory, while assuring the high sampling frequency. The required processing power was supplied by a Spartan 3 FPGA chip. For Fourier transform calculation, the sine pattern stored in the FPGA and 4 identical block sets, a multiplier and an accumulator, were created by Core Generator and used. The previously used vector voltmeter solution was based on a DSP processor with additional circuits (CPLD chip, memories, buffers) and was replaced by a single FPGA chip solution. The selected FPGA offers enough resources and allows reducing the number of additional external components. The prototype of the proposed solution was realized using the FPGA evaluation board with an added module of A/D and D/A converters (Fig. 3). The analyzer was realized in a form of a virtual instrument, the control panel was created by software. The tests were performed on the reference resistors (Figs. 8 and 9). The prototype proved the concept. However, it requires further works. It is necessary to look for a more energy-efficient FPGA chip as well as to optimize the project in terms of powerconsumption minimization.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 9, 9; 694-697
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies