Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "young's modulus" wg kryterium: Temat


Wyświetlanie 1-11 z 11
Tytuł:
Mechanical properties of Si3N4 – graphene composites sintered by SPS method
Autorzy:
Klimczyk, P.
Jaworska, L.
Cygan, S.
Morgiel, J.
Major, Ł.
Olszyna, A.
Powiązania:
https://bibliotekanauki.pl/articles/391862.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
silicon nitride
graphene
Young's modulus
hardness
friction coefficient
wear rate
Opis:
Silicon nitride powder with a small addition of magnesium oxide and yttria stabilized tetragonal zirconia fine particles was used as a starting material. Multilayer graphene nanoplatelets were used as filler for silicon nitride based composites. Graphene content in the mixtures was 0‒2 wt. %. The composites were obtained by the Spark Plasma Sintering method at 1650°C under 35 MPa of uniaxial pressure. Separation of the agglomerated graphene platelets in the matrix was observed for these materials. Insufficient dispersity of graphene slightly decreased the mechanical properties of Si3N4 ceramics. The SEM and TEM microstructural analysis of sintered materials show that the applied pressure during the sintering process leads to the orientation of the graphene phase and in consequence causes anisotropy of properties. The differences of friction coefficients were examined with the Ball-on-Disc method for the two directions (parallel and perpendicular to the pressing axis). Also the specific wear rate of the ball for the direction parallel to pressing axis differ significantly in comparison to the wear for the direction perpendicular to the pressing direction.
Źródło:
Prace Instytutu Odlewnictwa; 2017, 57, 4; 235-239
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Study of Selected Properties of Ti EB PVD Coating Deposited Onto Inner Tube Surface at Low Temperature
Autorzy:
Kottfer, D.
Ferdinandy, M.
Kaczmarek, L.
Trebuňa, P.
Hvizdoš, P.
Powiązania:
https://bibliotekanauki.pl/articles/354943.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ti coating
properties
hardness
Young's modulus
growth direction of coating columns
Opis:
This study investigates the selected properties of the thin Ti coating applied by activated evaporation EB PVD technique. This technique was used for the deposition of Ti thin coating onto inner surface of OKhN3 MFA steel tubes. Deposition process was carried out at temperature 200°C. Conventional type of coatings - monolayer Ti - was analyzed by standard techniques for surface status and quality assessment - coating thickness, chemical composition by EDX analysis, adhesion, hardness, roughness, and growth direction of columns at room temperature. Ti monolayer achieved roughness Ra equal from 0.42 μm to 0.47 μm. The resulting hardness was from 2 GPa to 8.5 GPa depending on the sample location inside the vacuum chamber. Placing of the coated surface also affected the direction of grain growth of Ti coating columns. The angles α of grain growth were found to be from 40° to 60°. Angle α increased two to three times more than the incidence angle β (from 12° to 28°) of evaporated Ti particles. Values of the adhesion measured along the Ti growth direction were mostly higher (up to 10%) or the same as those measured perpendicular to it.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 1; 67-74
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of the Bias on Mechanical Properties of a-C:H CVD Thin Films
Autorzy:
Kottfer, D.
Marton, M.
Kaczmarek, Ł.
Kuffova, M.
Powiązania:
https://bibliotekanauki.pl/articles/403717.pdf
Data publikacji:
2018
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
mechanics
a-C:H thin film
hardness
Young's modulus
7075 Al alloy
Opis:
In this study a-C:H (hydrogenated amorphous carbon) thin films were deposited on the 7075 Al alloy without an interlayer using a DC CVD (direct current chemical vapor deposition) method with varied negative substrate bias in order to improve the hardness and Young´s modulus. The highest values of films hardness and Young´s modulus were 25.6±3.5 GPa and 140.3±4.6 GPa, respectively. The measured results show a promising potential of the a-C:H coated 7075 Al alloy for low load (up to 10 N) applications.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2018, 9, 1 (31); 23-30
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deposition and Analysis of DLC Thin Films Obtained on 7075 Aluminum Alloy
Autorzy:
Kuffova, M.
Marton, M.
Kottfer, D.
Rehak, F.
Powiązania:
https://bibliotekanauki.pl/articles/403871.pdf
Data publikacji:
2017
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
a-C:H film
CN film
hardness
Young's modulus
7075 aluminum alloy
Opis:
In this study a-C:H (hydrogenated amorphous carbon) thin films were deposited on the 7075 Al alloy without and with admixture gas (N2) using a DC CVD (direct current chemical vapor deposition) method. The structural and mechanical properties were analyzed using Raman spectroscopy, SEM and nanoindentation. We obtained hardness of a-C:H thin film without and with N2 equal to 27.3 GPa and 21.4 GPa, respectively. Values of the Young’s modulus were equal to 135.5 GPa and 205.2 GPa, respectively.
Źródło:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa; 2017, 8, 3 (29); 33-42
2081-5891
Pojawia się w:
Problemy Mechatroniki : uzbrojenie, lotnictwo, inżynieria bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effects of Grain Boundary Structures on Mechanical Properties in Nanocrystalline Al Alloy
Autorzy:
Jang, Jin Man
Lee, Wonsik
Ko, Se-Hyun
Powiązania:
https://bibliotekanauki.pl/articles/2049173.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
nanocrystalline Al alloy
Young’s modulus
hardness
nanoindentation
low and high angle grain boundary
Opis:
This study investigates the effects of grain boundary structures on mechanical properties of nanocrystalline Al-0.7Mg-1.0Cu alloy using nanoindentation system. Grain boundary structure transforms to high angle grain boundaries from low angle ones with increase of heat treatment temperature and the transformation temperature is about 400°C. Young’s modulus and hardness are higher in sample with low angle grain boundaries, while creep length is larger in sample with high angle ones. These results indicate that progress of plastic deformation at room temperature is more difficult in sample with low angle ones. During compression test at 200°C, strain softening occurs in all samples. However, yield strength in sample with low angle grain boundaries is higher twice than that with high angle ones due to higher activation energy for grain boundary sliding.
Źródło:
Archives of Metallurgy and Materials; 2021, 66, 4; 971-975
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical properties of colored acrylonitrile-butadiene-styrene injection molded parts
Właściwości mechaniczne barwionych wyprasek z kopolimeru akrylonitryl-butadien-styren
Autorzy:
Trzaskalska, M.
Palutkiewicz, P.
Bociąga, E.
Powiązania:
https://bibliotekanauki.pl/articles/945806.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
ABS
coloring agent
injection molding
hardness
impact strength
tensile strength
Young's modulus
koncentrat barwiący
wtryskiwanie
twardość
udarność
wytrzymałość na rozciąganie
moduł sprężystości
Opis:
This article presents the results of examination of processing conditions such as mold Tf and injection Tw temperature influence on mechanical properties of the moldings made of copolymer ABS (acrylonitrilebutadiene-styrene) without and with a coloring agent in the form of a pigment and its masterbatches. The pigment was added in the amount of 1 wt ‰ and 2 wt ‰, while the masterbatches were added in the amount of 1 wt % and 2 wt %. The mechanical properties of the molded parts were determined in hardness, impact strength and tensile strength tests. The analysis of the obtained results allowed to state that the addition of the coloring agent in a form of pigment does not significantly affect the values of hardness and impact strength. However, the change of the processing conditions, e.g., increasing the mold temperature, contributed to the decrease of hardness and, at the same time, to the increase of impact strength. The tensile strength of the moldings made of ABS without and with the addition of the masterbatch is similar, regardless of the injection molding parameters, whereas their strain at break and Young’s modulus change, depending on the injection molding parameters. When using the low values of the mold temperature (30 °C) and injection temperature (230 °C), lower values of Young’s modulus were found, however, the aforementioned temperatures allow for obtaining a higher strain at break (noticed for colored samples).
Oceniano wpływ warunków przetwórstwa: temperatury wtryskiwania Tw oraz temperatury formy Tf na właściwości mechaniczne wyprasek wytworzonych z kopolimeru akrylonitryl-butadien-styren (ABS) bez dodatku i z dodatkiem środka barwiącego w postaci koncentratu lub pigmentu. Koncentrat dozowano w ilości 1 % mas. i 2 % mas., a pigment w ilości 1 ‰ mas. i 2 ‰ mas. Badania właściwości mechanicznych wyprasek obejmowały twardość, udarność i statyczną próbę rozciągania. Na podstawie analizy otrzymanych wyników stwierdzono, że dodatek środka barwiącego nie wpływa w istotnym stopniu na twardość i udarność wyprasek. Natomiast zmiana parametrów przetwórstwa, np. podwyższona temperatura formy, przyczynia się do zmniejszenia twardości, a jednocześnie zwiększenia udarności. Bez względu na warunki przetwórstwa wytrzymałość na rozciąganie próbek z tworzywa ABS bez dodatku oraz z dodatkiem koncentratu barwiącego była zbliżona, natomiast w zależności od warunków wtryskiwania następowała zmiana ich odkształcenia przy zerwaniu oraz modułu sprężystości przy rozciąganiu. W wypadku wyprasek barwionych zastosowanie niskiej temperatury formy wtryskowej (30°C) oraz niskiej temperatury wtryskiwania (230°C) powodowało zmniejszenie wartości modułu sprężystości oraz, na ogół, zwiększenie wartości odkształcenia przy zerwaniu.
Źródło:
Polimery; 2018, 63, 11-12; 791-798
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ modyfikacji radiacyjnej i termicznej na właściwości funkcjonalne polietylenu
The influence of radiation and thermal modification on the functional properties of GUR 1050 polyethylene
Autorzy:
Maszybrocka, J.
Cybo, J.
Barylski, A.
Czaja, P.
Powiązania:
https://bibliotekanauki.pl/articles/189949.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMW
modyfikacja radiacyjna
obróbka termiczna
twardość
moduł sprężystości
zużycie liniowe
UHMW polyethylene
radiation modification
thermal treatment
Young's modulus
hardness
linear wear
Opis:
W pracy przedstawiono metodę poprawy trwałości eksploatacyjnej UHMWPE przy jednoczesnym zapewnieniu wysokiej odporności oksydacyjnej polimeru. Materiał wyjściowy GUR 1050 (Poli Hi Solidur Medi TECH) został poddany sekwencyjnemu procesowi, który składał się z etapu modyfikacji radiacyjnej oraz obróbki termicznej. Ocenę skuteczności zastosowanej metody przeprowadzono za pomocą badań mikromechanicznych oraz testów tribologicznych na testerze T-01 (polimer/stop Vitalium). Stwierdzono nieznaczne zmniejszenie się charakterystyk mikromechanicznych (twardość i moduł Younga) wariantów poddanych sekwencyjnemu procesowi modyfikacji w stosunku do tylko napromieniowanych. Wyniki testów tribologicznych wykazują jednak wzrost odporności na zużycie w porównaniu z materiałem niemodyfikowanym i jej niezmienioną wartość w stosunku do polimeru napromieniowanego.
This paper presents a method of improving the operational durability of UHMWPE, while ensuring high oxidation resistance of the polymer. The initial material, GUR 1050 (Poly Hi Solidur Medi TECH), underwent a sequential process consisting of a stage of modification through radiation, and a stage of thermal processing. The assessment of the effectiveness of the applied method was performed using micromechanical examination and tribological tests using a T-01 (polymer/Vitalium alloy) tester. It was found that there was a slight decrease in the micromechanical characteristics (hardness and Young's modulus) for the variants subjected to the sequential modification process compared to the variants only irradiated. However, the tribological test results show an increase in resistance to wear compared to unmodified material, and unchanged resistance to wear compared to the irradiated polymer.
Źródło:
Tribologia; 2012, 4; 167-173
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of dental materials on hardness and Young’s modulus of the surface layers of tooth enamel formed as a result of friction
Autorzy:
Wojda, Sylwia
Sajewicz, Eugeniusz
Powiązania:
https://bibliotekanauki.pl/articles/306812.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
szkliwo
twardość
materiał stomatologiczny
tarcie
moduł Younga
enamel
hardness
dental material
wear
nanoindentation
Young’s modulus
Opis:
The purpose of this work was to determine the influence of dental materials used as permanent fillings on the mechanical properties of the tooth enamel surface layer subjected to friction with these materials. Methods: Dental composite materials (five types) were differentiated in terms of size and shape of the filler particles and matrix type over the course of tests on the chewing simulator under two different loads set during friction. Next, it was measured values of wear and nanoindentation for the resulting friction rates on the enamel (3 different load ranges). Results: It was found that the enamel’s resistance to tribological wear is significantly higher than that of the tested dental materials. It is also important to note that, depending on the penetration depth of the indenter (depends on the indenter pressure), different hardness values and Young’s modulus of enamel were obtained after friction with different dental materials. This demonstrates the formation of a surface layer with different properties than the native material. Conclusions: Analysis of the obtained results suggests the existence of different tribological wear mechanisms, as evidenced by significant differences in the wear values of dental materials and enamel. The data show that the enamel surface layer modified by the contacting dental material is shaped to a certain depth, and different thickness ranges of the changed layer have different properties.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 1; 129-139
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności napromieniowania wiązką elektronów w aspekcie podwyższania odporności na zużycie polietylenów GUR 1020 i GUR 1050 stosowanych na panewki endoprotez
Evaluation of electron beam irradiation effectiveness in view of increasing wear resistance of GUR 1020 and GUR 1050 polyethylenes used for endoprosthesis cups
Autorzy:
Barylski, A.
Cybo, J.
Maszybrocka, J.
Czaja, P.
Powiązania:
https://bibliotekanauki.pl/articles/189986.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMW
modyfikacja radiacyjna
odkształcenie polimeru
twardość
moduł sprężystości
zużycie masowe i liniowe
UHMW polyethylene
radiation modification
polymer deformation
Young's modulus
hardness
mass wear
linear wear
Opis:
W celu zwiększenia odporności polietylenu GUR 1020 i GUR 1050 na odkształcenie plastyczne i zużycie ścierne przeprowadzono modyfikację radiacyjną. Stosowano napromieniowanie elektronami o dawce 26-156 kGy. Wraz ze wzrostem dawki napromieniowania odnotowano zwiększenie twardości i modułu sprężystości podłużnej. Stwierdzono również, że GUR 1050 (o ciężarze cząsteczkowym 9,2•106 g/mol) cechuje się 1,86 razy większą odpornością na trwałą deformację. Wskazuje to na ścisły związek właściwości polimerów z ciężarem cząsteczkowym, który dla GUR 1020 wynosi 5•106 g/mol. Potwierdzenie stanowi mniejsza wartość zużycia tribologicznego GUR 1050 niż GUR 1020, która już w stanie wyjściowym polimerów przekracza 20%. Testy tribologiczne przeprowadzone na testerach T-05 i T-01 dowodzą, że napromieniowanie elektronami (6×26 kGy) obu polimerów powoduje 4-krotne zmniejszenie zużycia w stosunku do polietylenów niemodyfikowanych. Uzyskane wyniki dowodzą skuteczności modyfikacji radiacyjnej, która rokuje możliwość wydłużenia czasu użytkowania panewek endoprotez.
Radiation modification was conducted in order to increase the resistance of GUR 1020 and GUR 1050 polyethylenes to plastic deformation and abrasive wear. Electron irradiation of 26-156 kGy dose was applied. It was determined that the hardness and longitudinal elasticity module increase along with the increase in the dose of radiation. It was also found that GUR 1050 (of a molecular weight of 9.2•106 g / mol) is characterised by a 1.86 times greater resistance to permanent deformation. This indicates a close relationship between the properties of polymers and molecular weight, which for the GUR 1020 is 5•106 g/mol. This is corroborated by a lower value of tribological wear of GUR 1050 compared to GUR 1020, which already exceeds 20% in the initial state of polymers. Tribological tests conducted on the T-05 and T-01 testers have shown that electron irradiation (6x26 kGy) of both polymers result in a four-fold reduction in wear as compared to unmodified polyethylenes. The obtained results demonstrate the effectiveness of radiation modification, which promises the possibility of extending the service life of endoprosthesis cups.
Źródło:
Tribologia; 2012, 4; 17-23
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ modyfikacji radiacyjnej elektronami na deformację plastyczną, właściwości mechaniczne oraz zużycie polietylenu GUR 1050, stosowanego na panewki endoprotez
The influence of e-beam radiation on plastic deformation, mechanical properties and wear of the polyethylene GUR 1050 for acetabular cups
Autorzy:
Barylski, A.
Cybo, J.
Maszybrocka, J.
Czaja, P.
Powiązania:
https://bibliotekanauki.pl/articles/189777.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
polietylen UHMWPE
modyfikacja radiacyjna
obciążenie eksploatacyjne
odkształcenie polimeru
twardość
moduł Younga
zużycie masowe
zużycie liniowe
UHMW polyethylene
radiation modification
operational load
polymer deformation
hardness
Young's modulus
mass wear
linear wear
Opis:
Odporność polietylenu na zużycie i deformację trwałą wpływa na trwałość polimerowo-metalowych układów kinematycznych. Z myślą o zwiększeniu trwałości zabiegów alloplastyki został wprowadzony polimer GUR 1050 o ciężarze cząsteczkowym 9,2*106 g/mol, który przeznaczony jest zwłaszcza na implanty medyczne. Uzasadnia to celowość oceny odporności tego materiału na zużycie i odkształcenie, a także stwierdzenie, czy jego właściwości użytkowe można podwyższyć poprzez modyfikację radiacyjną. Próbki polimeru wyjściowego (bazowego) napromieniowano elektronami, stosując krotność napromieniowania I = 1–6 dawką 26 kGy. Analiza zmian wartości odkształcenia pod wpływem obciążeń eksploatacyjnych wykazała wzrost odporności polietylenu na deformację trwałą w wyniku zastosowanego napromieniowania. Poprawa właściwości mechanicznych została potwierdzona badaniami mikroindentacyjnymi. Stwierdzono wzrost twardości i modułu Younga. Efekt ten jest zachowany mimo przeciwnego trendu, który wywołuje rosnący stopień deformacji plastycznej polimeru pod wpływem obciążenia. Badania tribologiczne wykazały znaczący wzrost (ok. 4 razy) odporności na zużycie ścierne polietylenu modyfikowanego radiacyjnie. Znaczne ograniczenie zużycia rokuje dłuższy okres współpracy węzła tarcia, co wydłuży czas użytkowania panewki w ludzkim organizmie. Przedstawione w pracy wyniki dowodzą skuteczności modyfikacji radiacyjnej, która podwyższa badane właściwości funkcjonalne proporcjonalnie do zastosowanej dawki napromieniowania elektronami.
The resistance of polyethylene to wear and permanent deformation influences the durability of polymer-metal kinematic systems. The recently introduced polyethylene, GUR 1050, of a molecular weight of 9.2 * 106 g/mole is intended especially for medical implants. This justifies the need for evaluating the resistance of this material to wear and deformation and for determining if its functional properties can be improved by radiation modification. Samples of the initial (base) polymer were electron-irradiated with applying an irradiation multiplication factor I = 1–6 and a dose of 26 kGy. An analysis of changes in the deformation value under the influence of operational loads has shown an increase in the polyethylene resistance to permanent deformation as a result of the irradiation applied. The improvement of mechanical properties has been confirmed in micro-indentation tests. An increase in the hardness and Young's modulus was identified. This effect has been preserved despite an opposite trend that causes a growing level of plastic deformation of the polymer under the influence of load. Tribological tests have shown a significant increase (by ca. 4 times) in the resistance to abrasive wear of the polyethylene modified through irradiation. The significant wear reduction prognosticates a longer life of the friction couple, which will prolong the durability of acetabular cups in the human organism. The test results presented in the paper prove the effectiveness of modification through irradiation that enhances the tested functional properties proportionally to the applied dose of electron irradiation.
Źródło:
Tribologia; 2011, 5; 11-20
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The evaluation by means of microindentation and sclerometry of changes in properties after electron beam irradiation of polyethylene GUR 1050
Diagnozowanie metodą mikroindentacji i sklerometrii zmian właściwości po napromieniowaniu strumieniem elektronów polietylenu GUR 1050
Autorzy:
Barylski, A.
Cybo, J.
Maszybrocka, J.
Powiązania:
https://bibliotekanauki.pl/articles/187925.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
modyfikacja radiacyjna
obciążenie eksploatacyjne
odkształcenie polimeru
mikromechanizm zużycia ściernego
wskaźnik odporności na zużycie
twardość
moduł Younga
radiation modification
operational load
polymer deformation
abrasive wear micromechanism
resistance to wear ratio
hardness
Young's modulus
Opis:
With the aim to increase the resistance of GUR 1050 polyethylene to plastic deformation and abrasive wear, modification through radiation was applied. Compression tests of up to 300 MPa showed an increase in resistance to permanent deformation. This has been confirmed with microindentation and sclerometry tests. Scratch test indicated a lower tendency of the carved material to chipping than to uplift in all operational deformations. The domination of the micromechanism of the formation of ridges allows the material to retain a small decrease in resistance to wear. The parameters of microtests may be used for the purpose of the evaluation and selection of the polymers used in friction joints in medicine and technology.
W celu podwyższenia odporności polietylenu GUR 1050 na odkształcenie plastyczne i zużycie ścierne zastosowano modyfikację radiacyjną. Badania w zakresie naprężeń do 300 MPa wykazały wzrost odporności na deformację trwałą. Potwierdzono to testami mikroindentacyjnymi i sklerometrycznymi. Scratch test wykazał, że w całym zakresie odkształceń eksploatacyjnych występuje mniejsza skłonność do wykruszania materiału wyżłobionego niż do jego plastycznego wypiętrzania. Dominacja mikromechanizmu bruzdowania pozwala zachować niewielki spadek odporności na zużycie. Parametry mikrotestów mogą być wykorzystywane do diagnozowania i selekcji polimerów stosowanych w medycznych oraz technicznych węzłach tarcia.
Źródło:
Tribologia; 2012, 2; 23-29
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies