Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sensors" wg kryterium: Temat


Tytuł:
The sensitivity of sensor structures with oxide graphene exposed to selected gaseous atmospheres
Autorzy:
Pustelny, T.
Drewniak, S.
Setkiewicz, M.
Maciak, E.
Urbańczyk, M.
Procek, M.
Gut, K.
Opilski, Z.
Jagiello, J.
Lipinska, L.
Powiązania:
https://bibliotekanauki.pl/articles/200229.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
graphene
graphene oxide
gas sensors
resistive sensors
Opis:
The paper presents the results of investigations on the resistive structure with a graphene oxide (GO) sensing layer. The effects of dangerous gases (hydrogen and nitrogen dioxide) on the structure were studied; the resistance changes were examined during the flow of the selected gas in the atmosphere of synthetic air. Measurements were performed with a special emphasis on the detection of low concentrations of the analyzed gases. The reactions of the sensing structure to the effect of nitrogen and synthetic air at different humidity were also tested. Much attention was also paid to the fast response of the sensor to the changes in the gas atmosphere. The thin palladium layer (~2 nm) has been applied in order to improve the sensing properties of the structure. The investigations were performed in the temperature range from RT to 120°C and the analyzed gases in synthetic air were batched alternately with pure synthetic air.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 3; 705-710
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas sensors based on nanostructures of semiconductors ZnO and TiO2
Autorzy:
Pustelny, T.
Procek, M.
Maciak, E.
Stolarczyk, A.
Drewniak, S.
Urbańczyk, M.
Setkiewicz, M.
Gut, K.
Opilski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/201719.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas sensors
nanostructures
TiO2
ZnO
Opis:
The paper presents a resistance structures with sensor layers based on nanostructures elaborated on the base of TiO2 and ZnO. The structures were tested concerning their sensitivities to the effects of nitrogen dioxide in the atmosphere of synthetic air. The TiO2 and ZnO nanostructures played the role of sensor layers. Investigations have proved that the elaborated resistance structures with TiO2 and ZnO layers are sensitive to the presence of NO2 in the atmosphere of synthetic air. The resistance of the structure amounted to about 20 in the case of ZnO structures and to about 200 in the case of TiO2 structures. The investigations confirmed that resistance structures with ZnO and TiO2, exposed to the effect of nitrogen dioxide in the atmosphere of synthetic air changes their resistances relatively fast. This indicates that such structures might be practically applied in sensors of nitrogen dioxide ensuring a short time of response.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 4; 853-859
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of Surface Acoustic Wave Sensors for the Detection and Identification of Toxic Environmental Gases/Vapours
Autorzy:
Panneerselvam, G.
Thirumal, V.
Pandya, H. M.
Powiązania:
https://bibliotekanauki.pl/articles/176789.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
toxic gases
SAW
surface acoustic wave
SAW sensors
E-Nose
electronic nose
gas sensors
selective coating
Opis:
Detection and identification of toxic environmental gases have assumed paramount importance precisely in the defense, industrial and civilian security sector. Numerous methods have been developed for the sensing of toxic gases in the environment ever since surface acoustic wave (SAW) technology came into existence. Such SAW sensors called electronic nose (E-Nose) sensor use the frequency response of a delay line/resonator. SAW device is focused and given importance. The selective coating between input and output interdigital transducers (IDTs) in the SAW device is responsible for corresponding changes in operating frequency of the device for a specific gas/vapour absorbed from the environment. A suitable combination of well-designed SAW delay lines with selective coatings not only help to improve sensor sensitivity and selectivity but also leads to the minimization of false frequency alarms in the E-Nose sensor. This article presents a comprehensive review of design, development, simulation and modelling of a SAW sensor for potential sensing of toxic environmental gases.
Źródło:
Archives of Acoustics; 2018, 43, 3; 357-367
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Correction of gas sensor dynamic errors by means of neural networks
Autorzy:
Roj, J.
Urzędniczok, H.
Powiązania:
https://bibliotekanauki.pl/articles/114150.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
gas sensors
artificial neural networks
dynamic correction
Opis:
The paper presents a method based on artificial neural network (ANN) technique applied for correction of dynamic error of gas concentration measuring transducer. Its response time is about 8 minutes. The results obtained in the research of this transducer were used for learning and testing ANN, which were implemented in the dynamic correction task. The described method allowed for significant reduction of the transducer’s response time – the output signal was practically fixed after a time equal to one sampling period of output signal provided that the stimulus is a step function. In addition, the use of ANN allows reducing the impact of the transducer dynamic non-linearity on the correction effectiveness.
Źródło:
Measurement Automation Monitoring; 2015, 61, 12; 538-541
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perovskite La1-xSrxFeO3 Thin Films Deposited by Laser Ablation Process
Autorzy:
Cyza, A.
Cieniek, Ł.
Kopia, A.
Powiązania:
https://bibliotekanauki.pl/articles/352657.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Perovskite LaFeO3
thin films
gas sensors
PLD
Opis:
The aim of the research was to investigate the influence of strontium on the structure of thin films La1-xSrxFeO3 (x = 0; 0,1; 0,2). The LaFeO3 and Sr-doped LaFeO3 films were produced by pulsed laser deposition (PLD) on Si (100) substrate using the Nd-YAG (λ = 266 nm) laser. SEM, AFM and XRD methods were used to characterize the structure and morphology of the thin films. X-Ray Diffraction analysis showed only the LaFeO3 phase in the undoped thin film and the La0.9Sr0.1O3 and La0.8Sr0.2O3 phases in thin films doped by Sr. The mean crystallite size, calculated by Williamson-Hall method, was smaller (of the order of 18 nm) in films doped by Sr. SEM analysis showed small droplets in thin films doped by Sr. Highly developed surface layer was observed using the AFM microscope for thin films doped by Sr.
Źródło:
Archives of Metallurgy and Materials; 2016, 61, 2B; 1063-1067
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical investigations of ZnO layers affected by some selected gases in the aspect of their application in optical gas sensors
Autorzy:
Struk, P.
Pustelny, T.
Gołaszewska, K.
Borysiewicz, M. A.
Piotrowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/200967.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ZnO
semiconductor
gas sensors
Zno
czujniki gazu
półprzewodnik
Opis:
The paper presents the results of investigations of zinc oxide (ZnO) layers as a potential sensing material, being affected by certain selected gaseous environments. The investigations concerned the optical transmission through thin ZnO layers in wide spectral ranges from ultraviolet to the near infrared. The effect of the gaseous environment on the optical properties of zinc oxide layers with a thickness of ~ 400 nm was analyzed applying various technologies of ZnO manufacturing. Three kinds of ZnO layers were exposed to the effect of the gaseous environment, viz.: layers with relatively slight roughness (RMS several nm), layers with a considerable surface roughness (RMS some score of nm) and layers characterized by porous ZnO structures. The investigations concerned spectral changes in the transmission properties of the ZnO layers due to the effect of such gases as: ammonia (NH3), hydrogen (H2), and nitrogen dioxide (NO2) in the atmosphere of synthetic air. The obtained results indicated the possibility of applying porous ZnO layered structures in optical gas sensors.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 4; 829-836
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of quantum cascade lasers to trace gas detection
Autorzy:
Bielecki, Z.
Stacewicz, T.
Wojtas, J.
Mikołajczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/201703.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
absorption spectroscopy
biomarkers
sensors
gas sensors
cavity enhanced spectroscopy
photoacoustic spectroscopy
spektroskopia absorpcyjna
biomarkery
czujniki gazu
spektroskopia wzmocniona
spektroskopia fotoakustyczna
Opis:
The potential of Quantum Cascade Laser technology has been recently harnessed in industry, medicine and military to create a range of original infrared gas sensors. These sensors have opened up many new applications due to compact size, excellent sensitivity, robust construction and low power requirements. They rely on infrared absorption spectroscopy to determine identity and quantity of gases. The measurement of these gases has relied on different technologies including multi-pass spectroscopy, photoacoustic spectroscopy, cavity ring down spectroscopy, and their various modifications. In this review paper some technologies are described in terms of its advantages/disadvantages in many application. The results of own works about methane, ammonia, nitric oxide, nitrous oxide, and carbonyl sulfide detection are presented as well.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 2; 515-525
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Finite Element Analysis of SAW Sensor with ZnO Substrate for Dichloromethane (DCM) Gas Detection
Autorzy:
Moustafa, Mohamed
Laouini, Ghaylen
Alzoubi, Tariq
Powiązania:
https://bibliotekanauki.pl/articles/1945651.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
surface acoustic wave
SAW
gas sensors
VOCs
FEM modelling
Opis:
A SAW gas sensor based on Zinc Oxide (ZnO) piezoelectric substrate is simulated and evaluated for the detection of the dichloromethane (DCM) volatile organic compound (VOC). The study is performed based on the finite element method (FEM) using COMSOL Multiphysics software. The obtained device response using the ZnO substrate is compared to the one using the typical lithium niobate (LiNbO3) piezoelectric substrate. A thin film of polyisobutylene (PIB) membrane is selected to act as the sensing layer. The obtained results reveal a linear behaviour of the resonance frequency downshift (i.e., the sensor sensitivity) versus the investigated gas concentrations varying from 10 ppm to 100 ppm of DCM gas. Additionally, the sensor response is investigated by applying several thicknesses of PIB ranging from 0.3 µm to 1.0 µm. The observed sensor response shows less dependence on the PIB thickness using the ZnO substrate than the LiNbO3 one.
Źródło:
Archives of Acoustics; 2021, 46, 3; 419-426
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detection of Gaseous Compounds with Different Techniques
Autorzy:
Mikołajczyk, J.
Bielecki, Z.
Stacewicz, T.
Smulko, J.
Wojtas, J.
Szabra, D.
Lentka, Ł.
Prokopiuk, A.
Magryta, P.
Powiązania:
https://bibliotekanauki.pl/articles/220919.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
gas sensors
laser absorption spectroscopy
CEAS
MUPASS
breath analyses
medical screening
Opis:
Sensing technology has been developed for detection of gases in some environmental, industrial, medical, and scientific applications. The main tasks of these works is to enhance performance of gas sensors taking into account their different applicability and scenarios of operation. This paper presents the descriptions, comparison and recent progress in some existing gas sensing technologies. Detailed introduction to optical sensing methods is presented. In a general way, other kinds of various sensors, such as catalytic, thermal conductivity, electrochemical, semiconductor and surface acoustic wave ones, are also presented. Furthermore, this paper focuses on performance of the optical method in detecting biomarkers in the exhaled air. There are discussed some examination results of the constructed devices. The devices operated on the basis of enhanced cavity and wavelength modulation spectroscopies. The experimental data used for analyzing applicability of these different sensing technologies in medical screening. Several suggestions related to future development are also discussed.
Źródło:
Metrology and Measurement Systems; 2016, 23, 2; 205-224
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uproszczona metoda kalibracji przetworników do pomiaru stężenia gazów z czujnikami półprzewodnikowymi rezystancyjnymi
A simplified calibrating method for gas concentration measuring transducers with solid- state resistive sensors
Autorzy:
Urzędniczok, H.
Powiązania:
https://bibliotekanauki.pl/articles/153602.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
czujniki gazów
zmiany czasowe
kalibracja przetwornika
gas sensors
aging effects
transducer calibration
Opis:
W artykule opisano wyniki badań zmian czasowych typowego półprzewodnikowego rezystancyjnego czujnika gazów przeprowadzone w odstępie dwóch lat. Ze względu na znaczne zmiany charakterystyk, konieczna jest częsta kalibracja przetworników z takimi czujnikami. Opisano skrótowo metodę wyznaczania współczynników modelu odwrotnego uwzględniającego podstawowe wielkości wpływające. Wykazano, że pomimo znacznych zmian charakterystyk czujnika z upływem czasu, nie jest konieczna pełna ponowna kalibracja. Możliwa jest kalibracja uproszczona, zmierzająca do wyznaczenia mniejszej liczby współczynników niż liczba współczynników modelu pierwotnego. Pozwala to znacznie ograniczyć czasochłonność i pracochłonność kalibracji, co ma istotne znaczenie w przypadku przetworników do pomiaru stężenia gazów będących w ciągłej eksploatacji.
A very important feature of the resistive semiconductor gas sensors is ageing effect, sometimes very considerable. From a practical point of view, this results in the need for frequent calibration of gas concentration (C) measuring transducers equipped with such sensors. Calibration is typically laborious and time-consuming, due to the long response times of sensors [2], and to the impact of influence quantities (mainly temperature T and humidity H [3, 4]). The results of studies of temporal changes of a typical SnO2 based gas sensor carried out at an interval of two years are described in this paper. They indicate the possibility of a simplified calibration when the previously calibrated transducer is recalibrated after a long period of operation. Determination of all the coefficients of the complete model (formula 1), which allows the calculation of the measurement result, requires at least nine points of calibration in space (C, T, H). The simplification consists in the introduction of four additional correction factors determined in each recalibration, which allows scaling the output voltage of the converter according to the formula 4. The nine main coefficients in model (1), which was determined in the first calibration, remain constant. As a result, it is enough to recalibrate four points in space (C, T) instead nine points. The comparison of characteristics of Figure 5 shows that the proposed method is effective.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 5, 5; 269-271
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Deposition of Polymer Sensor Films on SAW Surface by Electrospraying Technology
Autorzy:
Jasek, K.
Pasternak, M.
Grabka, M.
Neffe, S.
Zasada, D.
Powiązania:
https://bibliotekanauki.pl/articles/177125.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Surface Acoustic Wave
SAW
gas sensors
deposition of chemosensitive films
Nafion® films
Opis:
One of the most important problems with regard to the Surface Acoustic Wave (SAW) gas sensors technology is the deposition of chemosensitive films exhibiting desirable chemical and physical properties. The electrospraying technology seems to be a very promising method of the film deposition in this case. It allows the chemosensitive layers to be obtained out of almost any chemicals and their mixtures in a controllable way. The process gives the possibility to generate specific films with properties unattainable if other methods were to be applied. For example, it allows to deposit solutions of polymers and suspensions of solids in polymer solutions which can degrade in the process of thermal evaporation deposition. The paper describes the results of experiments with electrospraying technique in order to obtain Nafion® films. The influence of the process parameters on film sensitivity has been studied.
Źródło:
Archives of Acoustics; 2017, 42, 3; 507-513
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary zanieczyszczeń odorowych wieloczujnikowym urządzeniem z tlenkowymi czujnikami gazu
Measurement of odour pollutants with multisensor device with TGS gas sensor
Autorzy:
Sobczuk, H.
Guz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/1819434.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
pomiar zanieczyszczeń
czujniki gazu
zanieczyszczenia odorowe
measurement of pollutants
gas sensors
odorous pollution
Opis:
Pomiary zapachowej jakości powietrza za pomocą urządzeń elektronicznych opartych na czujnikach gazów realizowane są już wielu gałęziach przemysłu. Stosuje się je w medycynie [1], w przemyśle spożywczym [6]. Znajdują też coraz szersze zastosowanie do monitoringu jakości powietrza w środowisku [10]. I tak np. zastosowane są na składowiskach odpadów, spalarniach, kompostowniach itp. [3÷5, 14]. Analiza zapachowa jest zadaniem wymagającym wcześniejszej kalibracji urządzeń i porównania ich wskazań z odczuciem zapachowym grupy osób testujących. Często stosowane czujniki TGS służą do detekcji zanieczyszczeń powietrza. Jest to możliwe dzięki zjawisku zmiany przewodnictwa elektrycznego półprzewodnikowego elementu pomiarowego w zależności od stężenia zanieczyszczenia, na które czujnik jest uczulony [8]. W czujnikach gazu TGS elementem pomiarowym jest elektroda wykonana z półprzewodnikowego dwutlenku cyny SnO2, wykazującego duże zmiany przewodnictwa pod wpływem redukujących zanieczyszczeń atmosfery. W zależności od przeznaczenia czujnika sensor zawiera różne domieszki, najczęściej metale szlachetne, powodujące jego uczulenie na specyficzny związek lub grupę związków chemicznych.
Measurement of odour quality of air with electronic devices is a task that requires calibration of the apparatus in advance. Calibration uses olfactory measurement results performed with the group of trained people. TGS sensors are often applied to detect the pollution of air with various pollutants. It is possible due to variation of electrical resistivity of the semiconducting sensor in response to the concentration of pollutants. Produced sensors are sensitized to specific pollutants but normally are not very specific. In a paper the measurement stand for measurement of odor pollutants concentration with multisensory device is presented and tested. Calibration measurements with the application of n-butanol is shown. Applied set of eight sensors allows to measure n-butanol samples with good accuracy. The setup allows measurements of both static, with a fixed concentration or dynamic by tracking changes in sensor response due to changes in odour pulse concentration change. Dynamic response of sensors makes it possible, in accordance with the literature, to measure with application of gas samples of a small volume. For the analysis of measurement results and comparison of different odours PCA method was used, which allows reduction of dimensionality of signal from multi-sensor devices.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1531-1542
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Automated system for fluctuation enhanced gas sensing
Zautomatyzowany system do poprawy czułości detekcji gazów z wykorzystaniem zjawisk fluktuacyjnych
Autorzy:
Trawka, M.
Smulko, J.
Hasse, L.
Powiązania:
https://bibliotekanauki.pl/articles/266568.pdf
Data publikacji:
2014
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
gas sensors
fluctuation-enhanced sensing
automation
czujniki gazu
szumy
poprawa czułości
automatyzacja pomiaru
Opis:
Resistance gas sensors exhibit random phenomena (resistance noise) which can be utilized to improve gas sensitivity and selectivity. That new emerging technique has to be investigated to recognize optimal parameters for gas detection. It means that a measurement system has to have ability of numerous parameters adjustment (e.g., sampling frequency, heater voltage, polarization current, voltage noise amplification). That fact induced design of a new setup which limits a number of external power sources and reduces time of gas sensors characterization. The newly prepared system comprises two digitally controlled voltage and current sources, and a control unit to select polarization current of the investigated gas sensor. The system is controlled by the dedicated PC software used for data acquisition and communication. The system allows characterizing of prototype gas sensors having a very high resistance, up to tens of M?. Additionally, the measured sensors can be irradiated by the UV diode to induce photocatalytic effect influencing their gas sensing properties. All these operation have been automated. An every action is automatically logged and state of the system is visualized using windows PC environment. Output files are batch-processed by means of commercial software, such as MATLAB®. Additionally, some exemplary results of recent experimental data for selected gas sensors, such as their noise spectra at various sensors temperatures has been presented.
W rezystancyjnych czujnikach gazu występują zjawiska losowe (np. szumy rezystancji), które mogą być wykorzystane do poprawy czułości i selektywności detekcji gazu. Aplikacja tej stosunkowo nowej techniki wymaga przeprowadzenia badań w celu ustalenia optymalnych parametrów detekcji gazów, co oznacza, że system pomiarowy powinien posiadać możliwość zmiany szeregu parametrów (np. częstotliwości próbkowania, napięcia grzałki, prądu polaryzacji, wzmocnienia napięcia szumów). Implikowało to konieczność zaprojektowania systemu z ograniczoną liczbą zewnętrznych źródeł zasilania i minimalizacji czasu charakteryzowania czujników gazu. Zbudowany system zawiera dwa cyfrowo sterowane źródła prądu i napięcia oraz układ sterujący wyborem prądu polaryzacji badanego czujnika gazu. System jest sterowany z komputera PC za pomocą opracowanego, dedykowanego oprogramowania i umożliwia charakteryzowanie prototypowych czujników gazu o rezystancji aż do dziesiątek M?. Czujnik może być ponadto poddany promieniowaniu przez diodę UV w celu wywołania efektu fotokatalizy, co wpływa na czułość detekcji gazu. Wszystkie wymienione czynności zostały zautomatyzowane w jak największym stopniu. Wszystkie wykonywane operacje są automatycznie rejestrowane, a aktualny stan systemu jest wizualizowany w postaci graficznej na monitorze PC. Pliki wyjściowe są przetwarzane wsadowo przy wykorzystaniu komercyjnego software’u takiego jak MATLAB®. Ponadto, przedstawiono przykładowe wyniki pomiarów uzyskane przy wykorzystaniu zaprojektowanego automatycznego stanowiska pomiarowego.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2014, 40; 133-136
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O pewnej metodzie wyznaczania czułości sensora gazuz AFP pracującego z akustycznie grubą warstwą chemioczułego polimeru
An approach to mass sensitivity prediction of SAW gas sensor with acoustically thick chemisensitive polymer layer
Autorzy:
Pasternak, M.
Powiązania:
https://bibliotekanauki.pl/articles/210681.pdf
Data publikacji:
2006
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
detekcja gazów
akustyczne fale powierzchniowe
czułość masowa
surface acoustic waves
gas sensors
mass sensitivity
Opis:
Opublikowane dotąd analizy czułości detektorów gazu z akustyczną falą powierzchniową (AFP) zakładają, że warstwa chemoczułego polimeru leżąca na powierzchni detektora jest akustycznie cienka, tzn. charakteryzuje się grubością znacznie mniejszą od długości sondującej ją fali akustycznej [1]. Takie założenie umożliwia bowiem przyjęcie dogodnych uproszczeń rachunkowych i jest uzasadnione przy stosunkowo niskich częstotliwościach pracy detektorów z AFP, kiedy to długość fali jest rzędu kilkunastu lub nawet kilkudziesięciu um. Przestaje ono jednak obowiązywać, jeśli częstotliwość pracy czujnika ulegnie radykalnemu zwiększeniu (uzasadnionemu potrzebą poprawy czułości). Już bowiem przy częstotliwościach rzędu setek MHz AFP charakteryzują się długościami rzędu pojedynczych um. Oznacza to, że konieczne jest opracowanie technik nakładania cieńszych warstw bądź rozszerzenie istniejących analiz na przypadek warstw akustycznie grubych. Niniejsza praca prezentuje pewien sposób takiego rozszerzenia.
In most of surface acoustic waves (SAW) sensors mass sensitivity analyses an acoustically thin chemisensitive layer deposited at the SAW substrate is assumed. Generally, the assumption mentioned above is physically justified for the sensors working in low frequency range where the acoustic waves are long enough. For high frequency range of SAW sensors (an order of GHz) such simplification may be not valid because the wavelength is then very short (um). For this reason, it is necessary to improve the layer deposition technology or extend the existing analyses. In the paper, an approach to such extension has been described. As a result, the mass sensitivity formula for SAW sensors with acoustically thick layers has been obtained. The formula derived in the paper confirms that mass sensitivity increases as a function of frequency.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2006, 55, 1; 113-123
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numeryczna korekcja dynamiki półprzewodnikowych czujników gazów
Numerical correction of dynamic properties of solid state gas sensors
Autorzy:
Urzędniczok, H.
Powiązania:
https://bibliotekanauki.pl/articles/157778.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
czujniki gazów
czas odpowiedzi
właściwości dynamiczne
korekcja dynamiczna
gas sensors
response time
dynamic properties
dynamic correction
Opis:
W artykule przedstawiono metodę oraz wyniki badań właściwości dynamicznych typowego półprzewodnikowego rezystancyjnego czujnika gazów. W oparciu o uzyskane wyniki zaproponowano model dynamiczny czujnika, wyznaczono jego współczynniki oraz przedstawiono dopasowaną do tego modelu numeryczną procedurę korekcji dynamicznej zapewniającą istotne skrócenie czasu odpowiedzi przetwornika do pomiaru stężenia gazu. Pokazano skuteczność zaproponowanej metody korekcji.
Solid state gas sensors have generally disadvantageous dynamic properties - their response time can reach several minutes or more. This is due to the fact that the chemical adsorption phenomena in the sensitive layer occur relatively slowly [1, 2]. In many measurement applications such a long response time is not acceptable. It is necessary to apply effective methods of dynamic correction. This paper presents a method and results of investigations of the dynamic properties of a typical semiconductor gas sensor with tin sensing layer. A numerical correction method is proposed, too. There were determined responses of the sensor to step changes in gas concentration by means of a measuring system shown schematically in Fig. 2. The results (see Figs. 3, 4 and 5) show that the first order inertia may be sufficient as an averaged dynamic model of the sensor. With respect to this model, the dynamic correction method is proposed. The procedure is illustrated in Fig. 6, and the calculation method is given in formula (3). Shortening of the step response time is expressed by the coefficient (0, 1). Examples of application of that algorithm to reproduce the abruptly and sinusoidally varying gas concentration are shown in Figs. 7 and 8 ( was assumed equal to 1/3, which was the postulated 3-fold reduction of the step response time). The waveforms confirm the effectiveness of the proposed dynamic correction method.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 2, 2; 80-82
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies