Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "retardants" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Assessment of the impact of the storage time of fire retardant and heating of the protected wood on the effectiveness of fireproofing
Autorzy:
Grześkowiak, Wojciech Ł.
Moliński, Krzysztof
Molińska-Glura, Marta
Cofta, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/2010790.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Drewna
Tematy:
fire retardants
Mini Fire Tube
wood protection
effectiveness
Opis:
It was investigated whether and how the storage time of a fireproof salt preparation affects the effectiveness of fire retardance. The impact of long-term heating of the treated wood on the effectiveness was also determined. Statistical methods were used to determine the significance of changes related to the age of the preparation and the effect of heating of treated wood on flame retardant effectiveness. A commercial fire retardant was used for the tests, with three different storage times and in five concentrations. The flammability tests were performed using the Mini Fire Tube method. It was concluded that the storage time of the preparation does not significantly affect the effectiveness values.
Źródło:
Drewno. Prace Naukowe. Doniesienia. Komunikaty; 2021, 64, 207; 145-157
1644-3985
Pojawia się w:
Drewno. Prace Naukowe. Doniesienia. Komunikaty
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of flame- retardant efficiency conservation term of thermo-foaming flame- retardant paints
Autorzy:
Yatsukovich, A.
Powiązania:
https://bibliotekanauki.pl/articles/136763.pdf
Data publikacji:
2011
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
endurance period
fire retardants
fire - retardant efficiency
activation energy
Opis:
The article defines the endurance period of fire protection efficacy as one of the most important characteristics for quality assessment of fire retardants. Experimental methods for determination of endurance period of fire protection efficacy for fire retardant coatings and endurance period of fire protection efficacy for impregnating compounds as well as endurance of fireproof wood are given. It is shown that modern fire retardant compounds represent complicated systems of non -organic and organic components and because of that the existing ex press methods for determination of endurance period of fire protection efficacy for paint coatings are not suitable for that. Endurance period of fire protection efficacy under natural conditions can be predicted by reproduction under simulated conditions of external factors with certain intensity and duration.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2011, 42; 227-229
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu cynianów cynku i mączki keratynowej na właściwości palne materiału epoksydowego
Analysis of the influence of zinc stannates and keratin powder on the flammability properties of epoxy material
Autorzy:
Półka, M.
Kukfisz, B.
Kulik, A.
Powiązania:
https://bibliotekanauki.pl/articles/945867.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
materiały epoksydowe
uniepalniacze
modyfikacja ogniochronna
szybkość wydzielania ciepła
epoxy materials
fire retardants
flame retardant modification
heat release rate
Opis:
Oceniano wpływ wybranych środków uniepalniających na właściwości pożarowe kompozytów na bazie żywicy epoksydowej Epidian 5 (Ep 5). Żywicę epoksydową modyfikowano ogniochronnie za pomocą hydroksycynianu(IV) cynku (ZHS), cynianu(IV) cynku (ZS) oraz materiału odpadowego – mączki keratynowej (KR). Metodą kalorymetru stożkowego wyznaczano szybkości wydzielania ciepła i dymu z palących się próbek kompozytów poddanych działaniu strumienia cieplnego o gęstości 30 kW/m2 i 50 kW/m2. Przeprowadzono też analizę termograwimetryczną otrzymanych niemodyfikowanych oraz modyfikowanych ogniochronnie materiałów. Stwierdzono, że dodatki ZS i ZHS, wprowadzone do utwardzonej żywicy Ep 5, skutecznie zmniejszają szybkość wydzielania ciepła z palących się próbek i mogą w istotnym stopniu ograniczyć rozprzestrzenianie się pożaru.
This paper analyses the impact of selected flame retardant additives on the combustibility and fire properties of epoxy materials based on Epidian 5 (Ep 5). The prepared epoxy resin was modified to increase its fire resistance using zinc hydroxystannate(IV) (ZHS), zinc stannate(IV) (ZS) and waste material – keratin powder (KR). The cone calorimeter was used to determine the heat and smoke release rates of burning composite samples using heat flux density of 30 and 50 kW/m2. Also, thermogravimetric analysis of the flame retardant modified and non-modified epoxy materials was performed. It was found that fire retardant additives ZS and ZHS added to the epoxy resin Ep 5 effectively decreased the heat release rate of the burning samples of cured resin and could significantly limit the spread of fire.
Źródło:
Polimery; 2017, 62, 10; 764-771
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Synthesis and performance of organophosphorus fire retardants from the reaction of trimethylolpropane and dimethyl methylphosphonate
Synteza fosforoorganicznych substancji ogniouodporniających w wyniku reakcji trimetylopropanu i dimetylo metylofosfonianu
Autorzy:
Quagliano, J. C.
Cruz, G.
Bocchio, J. A.
Witkiewicz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/209795.pdf
Data publikacji:
2011
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
fosforoorganiczne substancje ogniouodporniające
oligomery fosfonianowe
tlenek propylenu
różnicowa kalorymetria skaningowa
spektroskopia podczerwieni
fire retardants
oligomeric phosphonates
propylene oxide
differential scanning
infrared spectroscopy
Opis:
Organophosphorus fire retardants were synthetised from transesterification reaction of a bicyclic phosphite and dimethylmethyl phosphonate. Different reaction times were tested with the aim to reduce duration of the reactions. It was observed that 11 hours of heating at 200°C was enough for reaction completion, in contrast to previous studies where heating was performed for 24 hours at the same temperatures. Differential scanning calorimetry studies were performed and relevant thermal changes were identified. Infrared spectra were also registered and compared for the obtained substances. Finally, fire retardancy of oligomer phosphonates synthetised was verified testing polyurethane treated samples.
Wykonano syntezę fosforoorganicznych substancji ogniouodporniających. Synteza polegała na reakcji transestryfikacji dicyklicznych fosfonianów. Badano wpływ różnych czasów reakcji w celu zminimalizowania tego czasu. Stwierdzono, że 11 godzin ogrzewania w 200°C było wystarczające do zakończenia reakcji. Z wcześniejszych badań wynikało, że reakcję należy prowadzić przez 24 godziny. Przeprowadzono badania za pomocą różnicowej kalorymetrii skaningowej i określono zmiany zachodzące w otrzymanych substancjach w wyniku ich ogrzewania. Zarejestrowano też i porównano widma w podczerwieni tych substancji. W końcu sprawdzono działanie otrzymanych oligomerów fosfonianowych jako substancji przeciwzapalnych na próbkach poliuretanów w standardowych warunkach.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2011, 60, 2; 393-405
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of the influence of impregnation on the pine timber combustion using flow through tests
Badanie wpływu impregnacji ogniochronnej na skład i ilość produktów toksycznych powstałych podczas spalania drewna sosnowego
Autorzy:
Gałaj, J.
Jaskółowski, W.
Karpovic, Z.
Sukys, R.
Powiązania:
https://bibliotekanauki.pl/articles/373319.pdf
Data publikacji:
2011
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
amoniak
chlorowodór
cyjanowodór
drewno sosnowe
pożar
produkty spalania
środek ogniochronny
tlenek węgla
toksyczność
carbon monoxide
combustion products
fire
fire retardants
heat source
pine timber
toxicity
treatment
Opis:
Millions of people have lost their lives during fire in the recent decades, the majority died from inhalation of toxic fire effluents. Toxic fire effluents cause death in fire, as any incapacitation is likely to impede escape, and increase the chance of becoming trapped. Better understanding of this problem will contribute to the reduction in the number of such deaths in the future. This paper analyses emissions of carbon monoxide (CO), hydrogen chloride (HCl), hydrogen cyanide (HCN) and ammonia (NH3) during the combustion of non-impregnated and impregnated pine timber with fire retardants in research equipment for toxic combustion products emitted from solid materials after the impact of the heat source (e.g. flow through test). The toxicity of pine timber specimens was investigated at two powers of external heat source of 8 kW/m2 and 10 kW/m2.
Co roku wielu ludzi traci życie w czasie pożaru. Większość ginie z powodu wdychania toksycznych produktów rozkładu termicznego i spalania. Produkty te stanowią nie tylko bezpośrednią przyczynę śmierci ale także mogą utrudniać skuteczną ewakuację. Lepsze zrozumienie problematyki toksyczności produktów spalania przyczyni się do zmniejszenia liczby tych zgonów w przyszłości. Artykuł ten przedstawia wyniki badań emisji tlenku węgla (CO), chlorowodoru (HCl), cyjanowodoru (HCN) i amoniaku (NH3) podczas spalania bezpłomieniowego drewna naturalnego sosnowego, jak i impregnowanego przeciwogniowo dwoma komercyjnymi środkami ogniochronnymi produkowanym na Litwie. Do badań eksperymentalnych wykorzystano nie normatywną technikę pomiarową. Próbki poddano oddziaływaniu strumienia promieniowania cieplnego o gęstości 8 i 10 kW/m2.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2011, 3; 55-62
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanizm działania aerozolu gaśniczego
Mechanism of Fire-extinguishing Aerosol’s Action
Autorzy:
Izak, P.
Kidoń, A.
Mastalska-Popławska, J.
Powiązania:
https://bibliotekanauki.pl/articles/373967.pdf
Data publikacji:
2017
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
reakcje spalania
inhibitory palenia
aktywne rodniki wody
środki gaśnicze
aerozol gaśniczy
ochrona pożarowa eksponatów muzealnych
combustion reactions
fire retardants
active radicals of water
extinguishing agents
fire-extinguishing aerosol
fire protection of museum exhibits
Opis:
Cel: Celem artykułu jest dyskusyjne omówienie reakcji fizykochemicznych zachodzących w trakcie pożaru oraz przedstawienie mechanizmu działania inhibitorów palenia stosowanych w aerozolowych środkach gaśniczych. W artykule opisano również wyniki badań wpływu aerozolu gaśniczego na przedmioty muzealne. Wprowadzenie: Zazwyczaj w środkach gaśniczych wykorzystywany jest jeden z dwóch mechanizmów działania – obniżenie temperatury źródła pożaru (np. poprzez zastosowanie wody, proszków) albo odcięcie dostępu tlenu lub znaczne obniżenie jego ilości (np. za pomocą pian gaśniczych, z wyjątkiem tzw. gazów chlorowcopochodnych). Jednak w przypadku aerozoli gaśniczych zasada działania jest inna. Opiera się ona na przerwaniu reakcji fizykochemicznych zachodzących podczas spalania poprzez związanie wolnych rodników palenia prawdopodobnie powstałych z przekształcenia cząsteczek wody. Odbywa się to przy udziale aktywnych powierzchni nanoziaren aerozolu, który, w zależności od sposobu wyzwalania generatorów, może działać miejscowo lub objętościowo. Metoda ta jest bardzo efektywna. Mimo że nie zmniejsza poziomu tlenu w przestrzeni objętej pożarem, to w przeciwieństwie do proszków gaśniczych pozostawia śladową ilość zanieczyszczeń. Przede wszystkim nie wpływa negatywnie na środowisko poprzez zubożanie warstwy ozonowej i wzmożenie efektów cieplarnianych, gdyż w nowych aerozolach gaśniczych nie stosuje się halogenowych retardantów palenia. Metodologia: W pierwszej części artykułu dokonano przeglądu literatury z zakresu mechanizmów reakcji spalania, z uwzględnieniem udziału wody w tego typu procesach. W drugiej części artykułu skupiono się na przedstawieniu dyskusyjnego mechanizmu działania aerozolu gaśniczego, popierając te rozważania analizą wstępnych wyników badań dotyczących wykorzystania aerozolowych środków gaśniczych typu AGS 11/1 w celach ochrony eksponatów muzealnych, tj. figur drewnianych oraz starodruków. Wnioski: Przeprowadzona analiza literatury z zakresu mechanizmów reakcji spalania oraz działania aerozoli gaśniczych, a także wstępne wyniki badań pozwoliły na sformułowanie poniższych tez: – w początkowej fazie pożaru woda stanowi efektywny inhibitor palenia, jednak w późniejszych etapach aktywne rodniki powstałe na skutek jej rozkładu mogą podtrzymywać reakcję spalania płomieniowego, – aerozole gaśnicze nie wpływają na zmianę barwy figur drewnianych, ani nie zmieniają właściwości starodruków, przez co z powodzeniem mogą być stosowane w muzeach i budowlach zabytkowych.
Aim: The aim of this article is to discuss the physicochemical reactions which occur during a fire and to present the mechanism of action of fire inhibitors used in fire-extinguishing aerosols. The article also presents the results of research into the impact of fire-extinguishing aerosols on museum items. Introduction: Typically, there are two mechanisms used to extinguish fire, i.e. by lowering the temperature of the fire (e.g. by applying water or powders) or by cutting off the supply of oxygen or its significant reduction (with the exception of so-called chlorinated gases) by blanketing it with fire-extinguishing foams. However, in the case of fire-extinguishing aerosols, their action principle is different. It is based on the stopping of combustion reactions by binding active radicals which probably result from the conversion of water molecules through the active surface effect (whether local or by volume) of aerosol nanograins. This method is very efficacious. It does not reduce the level of oxygen in the air but, in contrast to the powders, leaves a trace amount of impurities. Most of all, however, it does not adversely affect the environment by ozone depletion or enhance the greenhouse effect due to there being no release of halogen-based fire retardants (in the latest type of aerosols). Methodology: The first part of the article includes a review of the literature on fire mechanisms, with the involvement of water in these processes. The second part focuses on the presentation of the mechanism of action of fire-extinguishing aerosols. This presentation is supported by an analysis of the preliminary research results concerning the use of aerosols type AGS 11/1 for the purposes of museum exhibits protection, i.e. wooden figures and old prints. Conclusions: The literature analysis in the field of combustion reactions mechanisms and action of fire-extinguishing aerosols, as well as the preliminary results of the research, allowed us to draw the following conclusions: – water is an effective inhibitor of combustion at the initial stage of the fire, but at later stages, active radicals generated by its decomposition can maintain the flame combustion reaction; – fire-extinguishing aerosols do not affect the colour of wooden figures, nor change the properties of old prints, which is why they can be successfully used in museums and historical buildings.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2017, 46, 2; 56-71
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies