Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "transients" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Comparison of transformer modeling on riser pole arresters behavior during switching transients
Autorzy:
Abbaszadeh, A.
Abedi, M.
Doustmohammadi, A.
Powiązania:
https://bibliotekanauki.pl/articles/140474.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arresters
ATP software
ferroresonance
transformer
power system transients
Opis:
Arresters are widely used in power systems to protect other equipment against overvoltages. However, in some conditions, they can’t operate successfully. One of the disturbances leading to the failure of the riser pole arresters is the ferroresonance overvoltages. In this paper, at first the influence of different transformer simulation models of ATP software on the occurrence of ferroresonance is studied and then the effect of ferroresonance on the riser pole arrester has been scrutinized through the thermal and electrical performance of the arrester in an underground distribution system. The results show that the arrester temperature rises due to energy dissipation in a ferroresonance circumstance, which indeed may result into the explosion of the arrester. Also, applying different models of the transformer in the ATP software and comparing the results, it is shown that the available models do not show the same effect on the arrester.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 717-730
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation on ferroresonance due to power transformer energization in high voltage 400 kV transmission grid
Autorzy:
Polewaczyk, Mateusz
Robak, Sylwester
Szewczyk, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/141509.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ferroresonance
high voltage
Poincaré map
power system transients
PSCAD
Opis:
This paper presents a study on ferroresonance occurring in a high voltage 400 kV transmission grid due to energization of power transformer under no-load conditions. The system scenarios analyzed in the present paper are considered as critical for development and modernization plans as currently announced by the national grid operator in Poland. The PSCAD simulation model was developed and applied for several study cases of a system with double-circuit arrangement of a transmission line. It is shown that the ferroresonant oscillations can be initiated by two-phase switching operation of a line circuit breaker. The impact of the double-circuit length on the ferroresonance mode and severity is demonstrated with the use of the Poincaré map analysis and Short Time Fourier Transform. It is demonstrated that the length of the transmission line that is mutually coupled in the double-circuit arrangement has a significant impact on the ferroresonance occurrence and on its mode. As the ferroresonance can pose severe threat to the power system components due to the severe overvoltage and overcurrent oscillations, the analysis presented in this paper demonstrates the necessity of the ferroresonance analyses for any re-designed transmission system.
Źródło:
Archives of Electrical Engineering; 2019, 68, 4; 771-786
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies