ATP/EMTP study of ferroresonance involving HV inductive VT and circuit breaker capacitance
Autorzy:
Stosur, M.
Piasecki, W.
Florkowski, M.
Fulczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/262758.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
inductive voltage transformer
transformer core
ferroresonance
ATP-EMTP
simulation
Opis:
Ferroresonance is a phenomenon usually initiated by transients in power networks resulting from e.g. switching operations or ground faults. Non linear behavior of the core of an inductive voltage transformer results in magnetic saturation. long-lasting ferroresonant state is dangerous to the equipment due to prolonged overvoltage and large overcurrents in HV windings.in the present article numerical simulations of the ferroresonance phenomenon in a HV inductive Vare presented. the ferroresonant oscillations analyzed result from interaction between the voltage transformer and a grading capacitance of a circuit breaker.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2008, 14, 2; 49-52
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ zjawisk ferrorezonansowych na pracę bezpiecznika przekładnika średniego napięcia
The effect of ferroresonance phenomena on operation of the fuse to medium voltage measuring transformer
Autorzy:
Tłustochowicz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/267582.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ferrorezonans
bezpiecznik przekładnika
przekładnik napięciowy
ferroresonance
voltage transformer’s fuse
voltage transformer
Opis:
Bezpieczniki przekładnikowe stanowią zabezpieczenia obwodów uzwojeń pierwotnych przekładników napięciowych od skutków zwarć. W praktyce eksploatacji sieci elektroenergetycznych średnich napięć z przekładnikami obserwowane są przypadki zadziałań bezpieczników przekładnikowych w następstwie zjawisk ferrorezonansowych. Przyczyną zjawisk ferrorezonansowych w przekładniku jest najczęściej nagły wzrost napięcia na jego uzwojeniu pierwotnym, wywołany przez przepięcia łączeniowe lub atmosferyczne. Wobec zmniejszenia się w tych warunkach indukcyjności magnesowania przekładnika może wystąpić sytuacja, w której indukcyjność ta z pojemnością doziemną systemu elektroenergetycznego stworzą obwód rezonansowy. W większości przypadków skutkuje to niekontrolowanym wzrostem prądu w obwodzie pierwotnym przekładnika, czego konsekwencją może być zadziałanie bezpiecznika przekładnika. Wieloletnia eksploatacja przekładników w systemach elektroenergetycznych średnich napięć z izolowanym punktem neutralnym potwierdza przypadki takich zdarzeń.
Measuring transformer fuses are used to the protection of primary winding of voltage measuring transformers against the ef-fects of short-circuits. In practice, under operating conditions of medium voltage networks with voltage measuring transfor-mers, there have been observed some cases of fuse maloperation resulting from the ferroresonance phenomena. The reason of ferroresonance phenomena in voltage measuring transformer is mostly a step-wise change of voltage across its primary winding, due to switching overvoltages or lightning surges. Under these circuimstances, the magnetizing inductance of vol-tage measuring transformer is significantly diminished, so a resonance circuit may be formed with the capacitance of power system versus earth. In most cases it results in an uncontrolled rise of the current in primary winding of voltage measuring transformer and consequently-maloperation of the fuse protection. Long-lasting observations on operation of voltage measur-ing transformers in medium voltage power system with isolated neutral point have confirmed the events of cases being considered in this paper.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2010, 28; 131-134
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca bezpiecznika przekładnika średniego napięcia w warunkach ferrorezonansu
Operation of fuses to medium voltage measuring transformers under ferroresonance condictions
Autorzy:
Tłustochowicz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/268080.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ferrorezonans
bezpiecznik przekładnikowy
przekładnik
przepięcie
ferroresonance
voltage transformer's fuse
voltage transformer
overvoltage
Opis:
Obserwowane są przypadki działania bezpieczników średnich napięć chroniących przekładniki napięciowe od skutków przetęSeń podczas ferrorezonansu napięć. W artykule przed-stawiono wyniki badań symulacyjnych wpływu zjawisk ferrorezonansowych na pracę bezpiecznika SN. Ferrorezonans moSe wystąpić w wyniku nagłej zmiany napicia pracy przekładnika, której przyczynami mogą być przepięcia łączeniowe lub atmosferyczne. Wyniki badań symulacyjnych nie wykluczają moSliwości działania bezpiecznika przekładnika SN w następstwie zjawisk ferrorezonansowych, powodowanych przepięciem. Przypadki takich zdarzeń są rejestrowane w praktyce eksploatacji sieci średnich napięć i potwierdzone badaniami laboratoryjnymi.
There are observed some cases of maloperation of fuses, which are used to the protection of medium voltage measuring transformers against results of overcurrents at voltage ferroresonance. The paper presents results of simulation study of the effect of ferroresonance phenomena upon medium voltage fuse operation. The ferroresonance may occur at a sudden change of measuring transformer operation voltage, which may result, e.g. from switching overvoltages or lightning surges. Simulation study has not excluded maloperation of a fuse to medium voltage measuring transformer resulting from ferroresonance phenomena. Such events have been registered in practice, in operation of medium voltage networks and confirmed by laboratory experiments.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2009, 26; 117-120
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Susceptibility of electrical network to ferroresonance occurrence
Autorzy:
Wiśniewski, J.
Anderson, E.
Karolak, J.
Powiązania:
https://bibliotekanauki.pl/articles/97465.pdf
Data publikacji:
2010
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electric network
ferroresonance
voltage transformer
EMTP-ATP
Opis:
The calculations of electrical network susceptibility of chosen 110 kV, 220 kV and 400 kV networks to ferroresonance occurrence, its type and parameters were performed in the study. The influence of such parameters as voltage transformer (VT) magnetization characteristic, equivalent network capacitance, and the breaker grading capacitance on ferroresonance was investigated. The calculations were performed using the EMTP/ATP program. Some of the results were presented in this paper.
Źródło:
Computer Applications in Electrical Engineering; 2010, 8; 46-52
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitivity of Power Station Auxiliary Network to the Possibility of Ferroresonance Occurrence
Wrażliwość sieci potrzeb własnych elektrowni na możliwość wystąpienia ferrorezonansu
Autorzy:
Wiśniewski, J.
Anderson, E.
Karolak, J.
Powiązania:
https://bibliotekanauki.pl/articles/397560.pdf
Data publikacji:
2014
Wydawca:
ENERGA
Tematy:
ferrorezonans
przekładniki napięciowe
bifurkacja
ferroresonance
voltage transformer
bifurcation
Opis:
Implementation of the new class of 1000 MW power units to a power system creates new problems associated with the operation of its individual components and circuits. One such issue is the phenomenon of ferroresonance in the internal load network. This is not a new problem but it requires examination due to the higher level of supply voltage (10 kV). This paper examines the possibility of ferroresonance occurrence and its character depending on the extent of the network, voltage transformers’ load, the effect of grounding resistors in the star point of the power transformer and the presence of varistor surge arresters. The results are presented in the form of ferroresonance maps. They allow assessing the impact of various parameters on the phenomenon, explaining the reasons for possible failure and properly programming the network conditions in order to avoid the risk of ferroresonance.
Wprowadzanie do systemu elektroenergetycznego bloków energetycznych klasy 1000 MW rodzi nowe problemy związane z eksploatacją poszczególnych jego podzespołów i obwodów. Jednym z takich zagadnień jest zjawisko ferrorezonansu w sieci potrzeb własnych. Nie jest to problem nowy, ale ze względu na wyższy od dotychczasowych poziom napięcia zasilania (10 kV) wymaga zbadania. W artykule autorzy przeanalizowali możliwość wystąpienia ferrorezonansu i jego charakter w zależności od rozległości sieci i obciążenia przekładników napięciowych, wpływ rezystorów uziemiających w punkcie neutralnym transformatora odczepowego oraz obecności ograniczników przepięć. Wyniki zaprezentowano w postaci wykresów bifurkacyjnych i map ferrorezonansu. Pozwalają one ocenić wpływ poszczególnych parametrów pracy na zjawisko, wyjaśnić przyczyny możliwej awarii i prawidłowo zaprogramować warunki pracy sieci tak, aby unikać zagrożenia ferrorezonansem.
Źródło:
Acta Energetica; 2014, 4; 171-182
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wrażliwość sieci potrzeb własnych elektrowni na możliwość wystąpienia ferrorezonansu
Sensitivity of power station auxiliary network to the possibility of ferroresonance occurrence
Autorzy:
Wiśniewski, J.
Anderson, E.
Karolak, J.
Powiązania:
https://bibliotekanauki.pl/articles/267445.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ferrorezonans
przekładniki napięciowe
bifurkacja
ferroresonance
voltage transformer
bifurcation
Opis:
Wprowadzanie do systemu elektroenergetycznego bloków energetycznych klasy 1000 MW rodzi nowe problemy związane z eksploatacją poszczególnych jego podzespołów i obwodów. Jednym z takich zagadnień jest zjawisko ferrorezonansu w sieci potrzeb własnych. W artykule przeanalizowano możliwość wystąpienia ferrorezonansu i jego charakter w zależności od rozległości sieci i obciążenia przekładników napięciowych, wpływ rezystorów uziemiających w punkcie neutralnym transformatora odczepowego oraz obecności ograniczników przepięć. Wyniki zaprezentowano w postaci wykresów bifurkacyjnych i map ferrorezonansu.
Implementation of the new class of 1000 MW power units to a power system creates new problems associated with the operation of its individual components and circuits. One of such issues is the phenomenon of ferroresonance in the internal load network. This is not a new problem but it requires examination due to the higher level of supply voltage (10 kV). This paper examines the possibility of ferroresonance occurrence and its character depending on the extent of the network, voltage transformers load, the effect of grounding resistors in the star point of power transformer and the presence of varistor surge arresters. The results are presented in the form of ferroresonance maps. They allow to assess the impact of various parameters on the phenomenon, explain the reasons for possible failure and properly program the network conditions in order to avoid the risk of ferroresonance.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 33; 111-114
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of transformer modeling on riser pole arresters behavior during switching transients
Autorzy:
Abbaszadeh, A.
Abedi, M.
Doustmohammadi, A.
Powiązania:
https://bibliotekanauki.pl/articles/140474.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
arresters
ATP software
ferroresonance
transformer
power system transients
Opis:
Arresters are widely used in power systems to protect other equipment against overvoltages. However, in some conditions, they can’t operate successfully. One of the disturbances leading to the failure of the riser pole arresters is the ferroresonance overvoltages. In this paper, at first the influence of different transformer simulation models of ATP software on the occurrence of ferroresonance is studied and then the effect of ferroresonance on the riser pole arrester has been scrutinized through the thermal and electrical performance of the arrester in an underground distribution system. The results show that the arrester temperature rises due to energy dissipation in a ferroresonance circumstance, which indeed may result into the explosion of the arrester. Also, applying different models of the transformer in the ATP software and comparing the results, it is shown that the available models do not show the same effect on the arrester.
Źródło:
Archives of Electrical Engineering; 2017, 66, 4; 717-730
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of ferroresonance oscillations in capacitive voltage transformer
Autorzy:
Iżykowski, J.
Rosołowski, E.
Pierz, P.
Powiązania:
https://bibliotekanauki.pl/articles/410537.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
capacitive voltage transformer
ferroresonance
suppression circuit
chaotic behaviour
simulation
Opis:
Analysis of ferroresonance oscillations in capacitive voltage transformer is presented. For this purpose an analytical approach to ferroresonance is firstly introduced. With use of the harmonic balance method the condition for avoiding stable subharmonic oscillations of the 3rd mode is stated. In the next step the ATP-EMTP simulation based investigations are carried out to find the suppression circuit parameter (or parameters) which assure damping of the nonlinear oscillations in accordance to the requirements of the standards. Two kinds of suppression circuits designed for the considered capacitive voltage transformer construction are investigated. The possible chaotic phenomena resulting from nonlinear oscillations are also examined. The obtained results are pr esented and discussed.
Źródło:
Present Problems of Power System Control; 2015, 6; 43-66
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies