Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "concrete compressive strength" wg kryterium: Temat


Tytuł:
Assessment of the concrete strength used in structures, using the destructive method
Ocena wytrzymałości betonu stosowanego w konstrukcjach, przy zastosowaniu metody niszczącej
Autorzy:
Michałowska-Maziejuk, Dorota
Goszczyńska, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/1403634.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
concrete
testing machine
concrete compressive strength
destructive method
water-cement ratio
beton
maszyna testująca
wytrzymałość betonu na ściskanie
metoda niszcząca
współczynnik wodno-cementowy
Opis:
This paper presents the analysis of the results of research on concrete compressive strength on cubic samples, in the early stage of its curing (after 7, 14, and 28 days). The analysis considers the variable water-cement ratio. Statistical and strength parameters were assessed, estimating the quality of the obtained concrete at the same time. Verification of the expected C25/30 concrete grade was carried out from the recipe provided by the prefabrication plant. Then, the grammage of individual components was adjusted to obtain the grade of concrete assumed by the authors. The article estimates the concrete grade based on strength parameters in three stages of concrete curing. The concrete was then compared with the concrete class calculated based on standard procedures (EC2 procedures), which could be reached after 28 days. The paper also provides an overview of the most used methods of testing concrete compressive strength.
W artykule przedstawiono analizę wyników uzyskanych z badania wytrzymałości betonu na ściskanie na próbkach sześciennych we wczesnej fazie jego dojrzewania (po 7, 14 i 28 dniach), z uwzględnieniem zmieniającej się wartości stosunku wodno-cementowego. Dokonano oceny parametrów zarówno statystycznych jak i wytrzymałościowych, szacując przy tym jakość produkcji otrzymanego betonu. Przeprowadzono weryfikację oczekiwanej klasy betonu C25/30, z udostępnionej przez zakład prefabrykacji receptury, a następnie zmieniono gramaturę poszczególnych jej składników w celu uzyskania założonej przez autorów klasy betonu równej C20/25. W artykule oszacowano klasę betonu na podstawie parametrów wytrzymałościowych w trzech stadiach czasowych i porównano ją z wyznaczoną według przepisów normowych wartością, która mogłaby zostać osiągnięta po 28 dniach. Otrzymane wyniki badań porównano z wyznaczonymi zgodnie z normą Eurokod 2 wartościami wytrzymałości, które mogłaby zostać osiągnięte po 28 dniach i oszacowaną na tej podstawie klasą betonu. W pracy dodatkowo przedstawiono przegląd najczęściej stosowanych metod badań wytrzymałości betonu na ściskanie.
Źródło:
Budownictwo i Architektura; 2021, 20, 2; 5-14
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of incorporating granite powder in the mechanical properties of concrete
Autorzy:
Muñoz Pérez, Socrates Pedro
Atoche Zamora, Jorge Jr.
Powiązania:
https://bibliotekanauki.pl/articles/36061575.pdf
Data publikacji:
2023
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
concrete
granite powder
compressive strength
flexural strength
workability
Opis:
This study analyzes the effects of the incorporation of the granite powder (GP) as a partial replacement of the sand in the concrete in percentages of 10%, 15%, 20% and 30% to carry out a mix design of 210 kg·cm–2. Seeking to find an optimal proportion to increase its mechanical properties where the geotechnical characteristics of the aggregates were identified, workability, temperature, beams and concrete specimens were elaborated. The results of bending and compression tests were compared after 7, 14 and 28 days from setting between the standard concrete and the concrete incorporated with the GP. It is concluded that the optimal result was at 20% GP with 268.6 kg·cm–2, where the compressive strength increases by 13%, while its flexural property rupture modulus of 35 kg·cm–2 and workability are in an optimal range according to the stipulated parameters, thus allowing an important application for this waste in the construction industry, therefore contributing to recycling, environmental quality and the development of the usage of new materials.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2023, 32, 1; 18-33
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wytrzymałości na ściskanie betonów różnego rodzaju wyznaczanej na próbkach prostopadłościennych
Assessment of the compressive strength of various kinds of concrete tested on cuboid samples
Autorzy:
Garbalińska, H.
Marciniak, B.
Powiązania:
https://bibliotekanauki.pl/articles/2068010.pdf
Data publikacji:
2017
Wydawca:
Politechnika Częstochowska
Tematy:
wytrzymałość na ściskanie
beton
beton lekki
beton wysokowytrzymały
compressive strength
concrete
lightweight concrete
high-strength concrete
Opis:
Przedmiotem artykułu jest ocena wzajemnych relacji ilościowych między wytrzymałościami na ściskanie, wyznaczonymi na próbkach prostopadłościennych o różnej wielkości. Eksperyment obejmował cztery grupy betonów o zróżnicowanym składzie. Był to beton zwykły, beton wysokiej wytrzymałości oraz dwie grupy betonów lekkich. Badaniom poddano kompozyty betonowe o szerokim spektrum wytrzymałości.
The purpose of this study was to assess the mutual quantitative relationships between the compressive strengths, designated on the rectangular samples, of different sizes. The experiment consisted of four groups of different concrete composites. The groups were ordinary concrete, high strength concrete, and two lightweight concretes. The concrete composites were broad-spectrum resistance.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2017, 23 (173); 78-85
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Świadectwo identyczności dostawy betonu - paszportem, wystawionym przez wykonawcę robót budowlanych
Evidence of identity issued by contractor - as passport of concrete delivery to construction site
Autorzy:
Kohutek, Z. B.
Powiązania:
https://bibliotekanauki.pl/articles/348997.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
beton
wytrzymałość na ściskanie
identyczność
concrete
compressive strength
identity
Opis:
W niniejszym artykule po raz pierwszy - poza normą - użyto sformułowania "identyczność" w odniesieniu do dostawy betonu. Uzasadniono celowość oceny identyczności. Omówiono zakres, procedury oraz kryteria. Kryterium dla uśrednienia rozbudowano korzystając z rozwiązania niemieckiego. Podano przykład liczbowy testu identyczności dostawy betonu, wytworzonego pod zakładową kontrolą produkcji - z certyfikatem i bez certyfikatu zewnętrznej jednostki notyfikowanej. Bazą są wyniki badania wytrzymałości na ściskanie. Wg normy EN 206-1 - ocenę zgodności prowadzi producent betonu [7, 8], zaś ocenę identyczności - wykonawca robót budowlanych, dla którego jest ona wiążąca. Ocenę identyczności można traktować jako niezależne uzupełnienie oceny zgodności.
In this article the notion of "identity" has been used for first time in relation to delivery of concrete (except for having used this notion in the norm). Advisability of the assessement of identity has been motivated. The criterion of average have been broadened basing on German solution. The article includes also numerical example of the identity test of delivery of concrete made under production control - with and without certificate of notification body. The base constitute the results of compressive strength inquiry. According to EN 206-1 norm - evaluation of conformity is realized by the concrete producer, and the evaluation of identity - by the contractor; this evaluation is binding on him. The evaluation of identity can be treated as an autonomous supplement of evaluation of conformity.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 2; 381-388
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelirovanie dinamiki izmenenia energeticeskogo potenciala pod vlianiem tehnologiceskih faktorov
Autorzy:
Bobko, T.
Powiązania:
https://bibliotekanauki.pl/articles/2068407.pdf
Data publikacji:
2009
Wydawca:
Politechnika Częstochowska
Tematy:
beton
wytrzymałość na ściskanie
mrozoodporność
concrete
compressive strength
frost resistance
Opis:
V nastoasej stat'e rassmatrivaetsa metod modelirovania vzaimosvazi mezdu osnovnymi faktorami, vliausimi na nabor procnosti betona pri ponizennyh i otricatel'nih temperaturah naruznogo vozduha.
W niniejszym opracowaniu omówiono metodę i algorytm modelowania współzależności pomiędzy głównymi czynnikami procesu uzyskania przez beton wytrzymałości na ściskanie, zapewniającej odporność mrozową w temperaturach obniżonych i zimowych za pomocą ciepła uwodnienia cementu.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2009, 15 (165); 97-106
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of ground waste glass addition on concrete prepared with their participation properties
Autorzy:
Jeleniewicz, Katarzyna
Rutkowska, Gabriela
Żółtowski, Mariusz
Kula, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/29521052.pdf
Data publikacji:
2023
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
sustainable development
glass waste
concrete
properties
frost resistance
compressive strength
Opis:
Caring for the environment, in accordance with the principles of sustainable development, as well as the increase in the standard of living of society, introduces the need to conduct proper waste management. Construction is an industry with great potential for the management of glass waste as part of material recycling. The construction sector is characterized by high material consumption, with a limited amount of natural resources, meaning that research is constantly being performed on the possibility of replacing them with other common ingredients. A feature of the building materials industry is also the pursuit of continuous improvement of the properties of manufactured materials. The paper presents the research results on the impact of the partial replacement of Portland cement and aggregate with glass waste on strength parameters and frost resistance. For the purpose of experimental work, a concrete mix based on the C20/25 standard concrete with CEM I 42.5R Portland cement, in which from 0 to 20% of the cement or aggregate weight is replaced with glass waste (i.e., glass flour and glass cullet), is designed. In the test range, the glass flour slightly affected the deterioration of the compressive strength, while the glass cullet had no effect on the compressive strength after 56 days of maturation. Moreover, the addition of glass flour increases the bending strength, while the addition of glass cullet maintains a comparable bending strength compared to the reference concrete. The obtained concretes are frost-resistant concrete F150.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2023, 73 (145); 46-53
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An investigation into structural strengths of laterized concrete
Badanie wytrzymałości betonu z zastosowanym laterytem
Autorzy:
Tsado, T. Y.
Powiązania:
https://bibliotekanauki.pl/articles/2068331.pdf
Data publikacji:
2013
Wydawca:
Politechnika Częstochowska
Tematy:
beton
lateryt
piasek
wytrzymałość betonu
wytrzymałość na ściskanie
wytrzymałość na rozciąganie
concrete
laterite
sand
concrete strength
compressive strength
tensile strength
Opis:
This paper presents the results of an investigation into the characteristics of concrete containing laterite as a full or partial replacement of sand. Sand in a concrete mix proportion of 1:2:4:0.6 and 1:2:2:0.6 (cement: sand: coarse aggregate: water-cement ratio) was replaced with 0, 20, 40, 60, 80, and 100% laterite. The concrete strength was confined to characteristic concrete strength grade of 20 and 25 N/mm². Experimental results based on qualitative and quantitative data shows that, concrete produced at 28-day hydration period with up to 40%> replacement level of sand by laterite attained the designed concrete compressive strength of 20.48 N/mm² for concrete strength grade of 20 N/mm² but fell slightly below 25 N/mm² for concrete strength of grade 25 N/mm². This indicates the possibility of using laterite as a partial replacement for sand up to 40%>. It was also observed from the results obtained that the workability - of laterite concrete increased with increase in the replacement level of sand by laterite, while the cube compressive strength, split cylinder tensile strengths and the percentage water absorption of the concrete decreased with increase in the replacement level of sand. Regression models relating the split cylinder tensile strength and cube compressive strength of concrete strength grade of 20 and 25 N/mm² of partial sand replacement with laterite in the various percentage, yielded predictive models ƒt(C20) = 0.2093 (ƒcu)0.5259 and ƒt(C25) = 0.4961 (ƒcu)0.2945 with correlation coefficients R² = 0.8946 and R² = 0.947 respectively.
W artykule przedstawiono wyniki badań w zakresie właściwości betonu zawierającego lateryt jako całkowity lub częściowy substytut piasku. Piasek z mieszanki betonowej o proporcji 1:2:4:0.6 i 1:2:2:0.6 (cement : piasek : kruszywo grube : stosunek cementowo-wodny) zastąpiono układem 0, 20, 40, 60, 80 i 100% laterytu. Wytrzymałość betonu została ograniczona do charakterystycznej wytrzymałości betonu - 20 i 25 N/mm². Eksperymentalne wyniki oparte na danych ilościowych i jakościowych pokazują, że beton po 28-dniowym okresie dojrzewania, w którym na poziomie do 40% zastąpiono piasek laterytem, osiągnął wytrzymałość na ściskanie 20,48 N/mm² dla zaprojektowanej klasy 20 N/mm², ale wartość wytrzymałości na ściskanie dla zaprojektowanej klasy 25 N/mm² spadła poniżej 25 N/mm². Wskazuje to na możliwość wykorzystania laterytu do częściowego zastąpienia piasku do 40%. Na podstawie otrzymanych wyników stwierdzono również, że urabialność betonu z wykorzystaniem laterytu wzrosła wraz ze wzrostem poziomu zastąpienia piasku przez lateryt, zaś wytrzymałość na ściskanie, wytrzymałość na rozciąganie i procent zużycia wody w betonie zmniejszyły się wraz ze wzrostem poziomu zastąpienia piasku. Modele regresji odnoszące się do wytrzymałości na rozciąganie i wytrzymałości na ściskanie betonu klasy 20 N/mm² i 25 N/mm², w którym piasek w różnych procentach częściowo zastąpiono laterytem, pozwoliły przyjąć modele analityczne: ƒt(C20) = 0.2093 (ƒcu)0.5259 oraz ƒt(C25) = 0.4961 (ƒcu)0.2945 ze współczynnikami R² = 0.8946 i R² = 0.947.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2013, 19 (169); 192--203
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kryterium zgodności wytrzymałości betonu na ściskanie opracowane na podstawie statystyk porządkowych
The study of the conformity criterion for compressive strength of concrete based on order statistics
Autorzy:
Szczygielska, E.
Tur, W.
Powiązania:
https://bibliotekanauki.pl/articles/390669.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
beton
wytrzymałość
kryterium zgodności
statystyki porządkowe
concrete
compressive strength
conformity criterion
order statistics
Opis:
Kontrola zgodności wytrzymałości betonu na ściskanie według obowiązujących przepisów normowych PN EN 206-1:2003 jest kontrolą wyrywkową opartą na ocenie liczbowej. Spełnienie podwójnych kryteriów z uwzględnieniem przyjętego planu statystycznej kontroli jakości potwierdza zgodność badanej partii betonu z deklarowaną klasą wytrzymałości, zdefiniowaną przez wytrzymałość charakterystyczną. Zalecane według tej normy kryteria zgodności na etapie produkcji początkowej nie są pozbawione wad i są krytycznie oceniane przez wielu autorów. W artykule przedstawiono nowe kryterium zgodności oparte na statystykach porządkowych. Dokonano wstępnej oceny opracowanego kryterium dla serii o małej liczbie wyników z wykorzystaniem prawdopodobieństwa akceptacji wyznaczonego metodą Monte Carlo przy założonej stałej wadliwości 5%. Analiza wyników wykazała, że przedstawione kryterium nie zależy od dyspersji wyników a prawdopodobieństwo akceptacji utrzymuje się na stałym poziomie, zbliżonym do poziomu właściwego na etapie produkcji ciągłej.
The test of concrete compressive strength conformity with current regulations PN EN 206-1:2003 is the sampling inspection based on a numerical evaluation. Satisfying the compound criteria, including the adoption of statistical quality control plan, confirms the conformity of the examined batch of concrete defined by the declared class of compressive strength defined by characteristic value of compressive strength. The conformity criteria recommended by EN 206-1 for the initial production are not without flaws and they are critically evaluated by many authors. This paper presents a new criterion of conformity based on order statistics. A preliminary evaluation of the criterion was made for the series with a small number of the test results with the use of probability of acceptance determined by means of the Monte Carlo method with the assumed 5% fraction defective. The analysis of the results showed that the presented criterion does not depend on the dispersion of results whereas the probability of acceptance is maintained at a constant level approached to the appropriate one at the stage of continuous production.
Źródło:
Budownictwo i Architektura; 2013, 12, 3; 223-230
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of Fly Ash from Thermal Treatment of Sewage Sludge According to the Applicable Standards
Autorzy:
Rutkowska, Gabriela
Powiązania:
https://bibliotekanauki.pl/articles/24201787.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
fly ash
sewage sludge
physical and chemical properties
concrete
compressive strength
heavy metals
Opis:
The restrictions on carbon dioxide emissions introduced by the European Union encourage experimental work on new generation materials containing smaller amounts of clinker. Currently, silica fly ash from the combustion of hard coal is widely used in cement and concrete technology in Europe and in Poland. Their wide application is mainly determined by their chemical and phase composition, especially pozzolanic activity, their high fineness, similar to cement. The aim of the research was to assess the properties of fly ash from thermal treatment of sewage sludge in terms of use in concrete technology in relation to EN 450-1, ASTM-C618-03 and ASTM C379-65T. The obtained test results confirm that the tested material has a different physicochemical composition and does not meet the requirements related to the use of ash in the production of concrete. In addition, the research showed the possibility of producing ordinary concrete, modified with fly ash from thermal treatment of sewage sludge. The average compressive strength for concrete containing 15% of ash from Cracow was set at 48.1 MPa and 49.2 MPa after 28 and 56 days of maturation, for ash from Warsaw at 42.0 MPa and 45.1 MPa, and for ash from Łódź at 36.2 MPa and 36.2 MPa. The determined concentrations of heavy metals are below the maximum values to be met when discharging waste water into the ground or water, the leaching limits required for accepting inert waste for disposal and for substances particularly harmful to the aquatic environment. On this basis, it was found that the migration of heavy metals from concretes with ash addition to the aquatic environment is insignificant and should not be a significant problem.
Źródło:
Journal of Ecological Engineering; 2023, 24, 3; 20--34
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przykład praktycznego skalowania funkcji dojrzałości betonu
Autorzy:
Bajorek, Grzegorz
Barć, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/342910.pdf
Data publikacji:
2020
Wydawca:
Stowarzyszenie Producentów Cementu
Tematy:
beton
beton dojrzewający
badanie
czas dojrzewania
wytrzymałość na ściskanie
concrete
early age concrete
testing
heat treatment
compressive strength
Opis:
Artykuł przedstawia metodę praktycznego wyznaczania zależności pomiędzy wytrzymałością betonu i jego dojrzałością, którą następnie zweryfikowano do szacowania aktualnej wytrzymałości betonu w konstrukcji poprzez ciągłe rejestrowanie jej temperatury. Zwrócono uwagę na potencjalnie małą wiarygodność szacowania wytrzymałości w początkowej fazie dojrzewania betonu na podstawie wyznaczonej w badaniach wstępnych krzywej korelacji.
The article presents a method of practical determination of the relationship between the strength of concrete and its maturity, which was then verified to estimate the current strength of concrete in the structure by continuously recording its temperature. Attention was drawn to the potentially low reliability of estimating the strength in the initial stage of concrete maturation on the basis of the correlation curve determined in the preliminary tests.
Źródło:
Budownictwo, Technologie, Architektura; 2020, 3; 62-65
1644-745X
Pojawia się w:
Budownictwo, Technologie, Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of maturing conditions of steel-fibre reinforced concrete on its selected parameters
Autorzy:
Czajkowska, Agnieszka
Raczkiewicz, Wioletta
Bacharz, Magdalena
Bacharz, Kamil
Powiązania:
https://bibliotekanauki.pl/articles/2065615.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
concrete
compressive strength
Young's modulus
steel fibre
fibre reinforced concrete
beton
włókno stalowe
beton zbrojony włóknami
wytrzymałość na ściskanie
moduł Younga
Opis:
In the article the impact of varying humidity conditions on selected strength properties of hardened steel fibre-reinforced concrete (such as Young’s modulus and the compressive strength of concrete) were analysed. The analysis shows that the value of the Young’s modulus of concrete cured under 100% humidity conditions is the highest; 35% higher compared to concrete hardening in the laboratory hall and about 18% higher than modulus measured in the concrete samples maturing in the chamber. A much higher compressive strength of approx. 25% was observed in samples hardening under 100% humidity conditions than in the other two environments. It was also observed that the non-uniform distribution of samples in the chamber and opening and closing the chamber during sample maturation had an impact on the dispersion of the results and due to the coefficient of variation, results can be even worse than in free-maturing samples.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2020, 9, 1; 47--54
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strengths of recycled concrete added with steel fiber
Autorzy:
Su, Q.
Powiązania:
https://bibliotekanauki.pl/articles/231177.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
kruszywo z recyklingu
włókno stalowe
konsystencja
wytrzymałość na ściskanie
wytrzymałość na zginanie
recycled aggregate
concrete
steel fiber
slump
compressive strength
flexural strength
Opis:
The strength of recycled aggregate (RA) is low, which makes the performance of recycled aggregate concrete (RAC) poor, and the addition of fiber can make up for the shortcoming of RAC. In this paper, the mechanical properties of RAC which was added with steel fiber were studied. The specimens with RA content of 0%, 40%, 70% 100% and steel fiber content of 0%, 0.5% and 1% were prepared, and their mechanical properties were tested. The results showed that the slump reduced 73.75% after the addition of 100% RA and 37.5% after the addition of 1% steel fiber compared to R0S0; from the perspective of mechanical properties, the larger the content of steel fiber, the better the mechanical properties of the specimen; the improvement of the tensile strength was the most obvious after the addition of steel fiber. The experimental results show that steel fiber can improve the performance of RAC and make it perform better in practical application.
Źródło:
Archives of Civil Engineering; 2020, 66, 3; 693-703
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie pyłu bazaltowego, jako substytutu piasku w zaprawie i betonie cementowym
Use of basalt powder in a cementitious mortar and concrete as a substitute of sand
Autorzy:
Dobiszewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/390735.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
odpadowy pył bazaltowy
zaprawa cementowa
beton
wytrzymałość na ściskanie
mrozoodporność
waste powder basalt
cementitious mortar
concrete
compressive
strength
freeze resistance
Opis:
W pracy przedstawiono wyniki badań dotyczących możliwości zastosowania odpadowego pyłu bazaltowego do produkcji zapraw oraz betonów cementowych. Wykorzystane w badaniach pyły stanowią odpad powstający podczas obróbki kruszywa stosowanego do produkcji mas mineralno-asfaltowych (MMA). Utylizacja tych odpadów stanowi obecnie duży problem w wielu wytwórniach MMA. Celem określenia wpływu dodatku pyłu bazaltowego na wybrane właściwości zapraw przeprowadzono badania wytrzymałości na zginanie i ściskanie po 2, 28 i 56 dniach dojrzewania próbek, określono mrozoodporność zapraw a także zdolność do kapilarnego podciągania wody, nasiąkliwość oraz współczynnik rozmiękania zapraw. Wpływ dodatku pyłu bazaltowego na parametry termoizolacyjne zapraw określono na podstawie pomiaru współczynnika przewodzenia ciepła w aparacie płytowym TCA 300. Przeprowadzone badania dotyczyły również analizy wpływu dodatku pyłu bazaltowego na wybrane właściwości betonu. W tym celu zbadano wytrzymałość betonu na ściskanie, po 28, 90 i 180 dniach oraz mrozoodporność. Odpadowy pył bazaltowy stanowił częściowy zamiennik piasku w ilości 0-30% masy piasku w przypadku zapraw oraz w ilości 0-20% masy piasku w przypadku betonów. Wyniki przeprowadzonych badań wskazują na to, że pył bazaltowy może być stosowany do produkcji zapraw i betonów cementowych, jako substytut piasku naturalnego. Zastąpienie części piasku przez pył bazaltowy wpłynie na poprawę niektórych właściwości tych materiałów oraz pozwoli na zagospodarowanie odpadu przemysłowego.
The present study shows the results of the possibility of using basalt powder in cementitious mortar and concrete. Asphalt mixture production leads to formation of significant amounts of mineral powder. It is used in a present research. Utilization of this waste is a problem in Asphalt Batch Mix Plant. Experiments were carried out to determine an influence of powder basalt on some properties of cementitious mortar. The compressive and flexural strength at 2, 28 and 56 days of curing, freeze resistance, absorptivity, capillary rise of water and softening factor were conducted. Thermal conductivity factor was determined by means of Thermal Conductivity Measuring Instrument TCA 300 to assess a thermal insulation parameters of mortars. Secondly, experiments were also carried out to determine an influence of addition of powder basalt on some properties of concrete. The compressive strength at 28, 90, 180 days of curing and freeze resistance were conducted. Cementitious mortars and concrete were prepared with powder basalt as a partial substitute of sand in amount of 0-30% and 0-20% sand mass respectively. The results show that powder basalt can be use as an effective substitute of fine aggregate in cementitious mortar and concrete. Use of the powder basalt as a partial substitution of sand improves some properties of cementitious mortar and concrete and anable for the management of industrial waste.
Źródło:
Budownictwo i Architektura; 2016, 15, 4; 75-85
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Współczynnik intensywności naprężeń w betonie a jego wytrzymałość na ściskanie
The stress intensity factor and compression strength of concrete
Autorzy:
Plechawski, S.
Powiązania:
https://bibliotekanauki.pl/articles/162260.pdf
Data publikacji:
2014
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
beton
naprężenie
odporność na rozciąganie
współczynnik intensywności naprężeń
wytrzymałość na ściskanie
współczynnik wodno-cementowy
concrete
stress
tensile strength
stress intensity factor
compressive strength
water-cement ratio
Opis:
Beton, który jest materiałem uniwersalnym, wieloskładnikowym, heterogenicznym i anizotropowym, jest jednym z podstawowych materiałów konstrukcyjnych powszechnie stosowanym w budownictwie. Wpływa na to łatwy dostęp do jego składników, dość niskie koszty wytworzenia, możliwość stosowania w zmiennych warunkach atmosferycznych, możliwość wznoszenia budowli i wykonywania konstrukcji w różnych technologiach. Eksploatacja konstrukcji budowlanych powoduje ich fizyczne zużycie, elementy betonowe i żelbetowe ulegają destrukcji. Z powodu bardzo wysokich kosztów budowy nowych obiektów użytkowane konstrukcje muszą być naprawiane i wzmacniane różnymi metodami. Zdarza się, że konstrukcje zaprojektowane poprawnie ulegają katastrofalnemu zniszczeniu w wyniku nagłego pękania. Wspólnym mianownikiem takich sytuacji jest obecność pęknięć pierwotnych. W konstrukcjach stalowych mogą być one efektem np. błędnego spawania, w betonowych – np. zjawisk skurczowych. Nagłe pękanie jest spowodowane, zachodzącym z szybkością dźwięku, wzrostem propagacji istniejących pęknięć, które nagle stają się niestabilne. Przekroczone zostaje krytyczne naprężenie, przy którym jest dostatecznie dużo energii na to, aby wykonać pracę rozrywania materiału.
Concrete is a universal, multi-component, heterogeneous, anisotropic material, and is one of the basic materials widely used in construction. Reasons for this include the easy availability of its components, relatively low production costs, usability in variable weather conditions, and the possibility of making structures using various different technologies. When structures are in use they are subject to physical wear, and concrete and reinforced concrete elements suffer degradation. Because of the very high costs of constructing new buildings, various methods must be applied to repair and reinforce existing structures. Sometimes even correctly designed structures suffer catastrophic damage as a result of sudden cracking. A common feature of such situations is the presence of primary cracks. In steel structures these may result from faulty welding, for example, while in the case of concrete the cause may be shrinkage effects. Sudden cracking is caused by growth, propagated at the speed of sound, in existing cracks, which rapidly become unstable. This involves the exceeding of the critical stress, where there is sufficient energy available to tear the material apart.
Źródło:
Przegląd Budowlany; 2014, R. 85, nr 7-8, 7-8; 50-53
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of compressive failure of concrete under static and dynamic loads
Autorzy:
Liu, L.
An, H. M.
Powiązania:
https://bibliotekanauki.pl/articles/230225.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
wytrzymałość na ściskanie jednoosiowe
dynamiczne ładowanie
szybkość odkształcania
pęknięcie
fragmentacja
concrete
uniaxial compressive strength
dynamic load
strain rate
fracture
fragmentation
Opis:
The fracture and fragmentation of concrete under static and dynamic loads are studied. The uniaxial compressive strength test is employed to study the concrete behavior under static loads while the split Hopkinson pressure bar is used to study the dynamic behavior of the concrete under static loads. The theories for acquiring the stress, strain and strain rate of the concrete in the dynamic test by Hopkinson pressure bar has been introduced. The fracture patterns of the concrete in the uniaxial compressive test have been obtained and the static concrete compressive strengths have been calculated. The fracture patterns of the concrete in the uniaxial compressive test have been obtained and the static concrete compressive strengths have been calculated. The fracture and fragmentation of the specimen under dynamic loads have been acquired and the stress-strain curves of concrete under various impact loads are obtained. The stress-strain curve indicates a typical brittle material failure process which includes existing micro-fracture closure stage, linear-elastic stage, nonlinear-elastic stage, and post-failure stages. The influence of the loading rate for the compressive strength of the concrete has compared. Compared with the concrete under static loads, the dynamic loads can produce more fractures and fragments. The concrete strength is influenced by the strain rate and the strength increases almost linearly with the increase of the strain rate.
Źródło:
Archives of Civil Engineering; 2020, 66, 3; 427-441
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies