Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "EDS," wg kryterium: Temat


Wyświetlanie 1-8 z 8
Tytuł:
A methodology for identifying the chemical composition of the surface of solids using the XPS and SEM/EDS techniques
Metodyka identyfikacji składu chemicznego powierzchni ciał stałych technikami XPS i SEM/EDS
Autorzy:
Bednarska, A.
Osuch-Słomka, E.
Grądkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/256723.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
SEM/EDS
XPS/ESCA
sputtering
vertical profile
SEM-EDS
profil głębokościowy
Opis:
In many fields of science and technology, it is necessary to apply non-destructive methods of analysis. Such non-destructive methods include scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (SEM/EDS) and X-ray photoelectron spectroscopy (XPS), and the results obtained with this set are often regarded as complementary. These methods were used in this study to research the chemical composition of the top layer of a model made with gold on a ceramic coating produced by the PVD technique on the surface of steel. The gold layer was ion sputtered until its complete removal and was studied by means of X-ray photoelectron spectroscopy and X-ray micro-analysis. It was found that the analytical data for an identical specimen obtained by SEM/EDS and XPS might differ significantly. This necessitates very careful consideration in treating these techniques as complementary, and during the interpretation of the results, one should take into account the physical essence of each method.
W wielu dziedzinach nauki i techniki niezbędne jest zastosowanie nieniszczących metod analizy. Do takich metod należy skaningowa spektroskopia elektronów sprzężona z mikroanalizą rentgenowską (SEM/EDS) oraz rentgenowska spektroskopia fotoelektronów (XPS), a wyniki uzyskiwane za ich pomocą często są traktowane jako uzupełniające się. W pracy zastosowano te metody do badania składu chemicznego modelowej warstwy wierzchniej, utworzonej ze złota na podłożu powłoki ceramicznej wytworzonej techniką PVD na powierzchni stali. Warstwę złota trawiono jonowo aż do jej całkowitego usunięcia i badano za pomocą rentgenowskiej spektroskopii fotoelektronów oraz mikroanalizy rentgenowskiej. Stwierdzono, że dane analityczne dla identycznej próbki uzyskiwane metodami SEM/EDS oraz XPS mogą dość istotnie różnić się. Oznacza to konieczność dużej ostrożności przy traktowaniu tych technik jako komplementarne, podczas interpretacji wyników należy uwzględniać fizyczną istotę obydwu metod.
Źródło:
Problemy Eksploatacji; 2015, 3; 39-48
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern Semi-Majolica and Glazed Ceramics from Rzeszów – Research on the Findings from the Archaeological Sites on 3 Maja Street
Autorzy:
Trąbska, Joanna
Kocańda, Paweł
Trybalska, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/958152.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Rzeszowski. Instytut Archeologii Uniwersytetu Rzeszowskiego. Muzeum Okręgowe w Rzeszowie
Tematy:
Podkarpacki
Rzeszów
semi-maiolica
glazed pottery
SEM/EDS
Opis:
Steadily growing collection of modern ceramics of the present Podkarpackie Voivodeship, has not yet been fully documented. Historical research demonstrates that Rzeszów, located on the communication route with Russia, occupied a very important position in trade relations with the East and West. The archaeometric study was performed on two fragments of semi-majolica plates and six fragments of glazed jugs, pots and tripod vessels. Vessels were made of fine-grained paste of smectite/illite, kaolinite/illite and kaolinite/illite/smectite clay. The richness of colours and shades is surprising. In the case of semi-majolica, the underglaze paintings were made with the use of frit pigments, while the overglaze ornament was made with the use of Pb-P-Ca-Si paste. ‘Slip-painting’ technique was also used. Glazes were coloured with iron, copper and cobalt compounds of various combinations and concentrations which provided different shades. In the case of semi-maiolica quartz-argillaceous primer with a potassium-bearing substance was applied, surfaces under glazes were covered with flux-bearing substances
Źródło:
Analecta Archaeologica Ressoviensia; 2019, 14; 109-136
2084-4409
Pojawia się w:
Analecta Archaeologica Ressoviensia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ilościowa i jakościowa analiza mieszanin pirotechnicznych – SEM/EDS
Quantitatvie and qualitative analysis of pirotechnical mixtures – SEM/EDS
Autorzy:
Łasińska, Anna
Barszcz, Krystyna
Powiązania:
https://bibliotekanauki.pl/articles/501617.pdf
Data publikacji:
2014
Wydawca:
Agencja Bezpieczeństwa Wewnętrznego
Tematy:
Mieszaniny pirotechniczne
skaningowa mikroskopia elektronowa
SEM
mikroanaliza rentgenowska
EDS
Pyrotechnic mixtures
scanning electron microscopy
energy-dispersive spectrometry
SEM/EDS
Opis:
Rozwój techniki pozwala na tworzenie nowszych i doskonalszych sposobów identyfikacji śladów przestępstw. Przez samą naturę różnych przestępstw objętych dochodzeniem kryminalistycznym mikroskop elektronowy SEM/EDS musi zapewnić najwyższą wszechstronność i wydajność. Metoda ta pozwala jednocześnie na obserwację badanego obiektu przy dużych powiększeniach oraz oznaczenie jego składu pierwiastkowego. W publikacji zaprezentowano analizę powierzchni ziaren mieszanin pirotechnicznych za pomocą skaningowego mikroskopu elektronowego SEM. Na podstawie map rozkładu stężenia pierwiastków w wybranych obszarach skanowania podjęto próbę identyfikacji konkretnych związków chemicznych, które były użyte do sporządzenia mieszanin pirotechnicznych. Było to możliwe dzięki określeniu pewnych cech wspólnych widocznych na mapach, takich jak rozkład i intensywność zabarwienia. Metoda ta w pewnych przypadkach nie zawsze jednak dawała jednoznaczne wyniki. Wyraźne zróżnicowanie ilościowego udziału danego pierwiastka w mieszaninie w istotny sposób wpływało na wynik analizy EDS.
The development of technology allows to create newer and better ways to identify traces of crime. Due to the nature of the various crimes under forensic investigation, the electron microscope SEM / EDS must provide the very highest flexibility and performance. Our method allows the observation of the object at high magnifications while simultaneously indicating its elemental composition. We describe the use of the SEM scanning electron microscope to analyze the morphological surface of grains of pyrotechnic mixtures. Based on mapping the distribution of the concentration of elements in selected areas the scan attempts to identify specific chemical compounds used in the preparation of pyrotechnic mixtures. This was made possible by defining certain common features shown on the maps, such as the distribution and intensity of color. In certain situations, however, our method did not always produce unequivocal results. Significant differences in the proportion of a given element in the mixture significantly affected the outcome of the analysis using EDS.
Źródło:
Przegląd Bezpieczeństwa Wewnętrznego; 2014, 6, 11; 177-205
2080-1335
2720-0841
Pojawia się w:
Przegląd Bezpieczeństwa Wewnętrznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inhibitive tendency of zinc gluconate for aluminium alloy in sulphuric acid solution
Autorzy:
Sanni, O.
Loto, C. A.
Popoola, A. P. I.
Powiązania:
https://bibliotekanauki.pl/articles/780091.pdf
Data publikacji:
2013
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
aluminium
zinc gluconate
inhibition
weight loss
potentiodynamic polarization
SEM/EDS
Opis:
The corrosion inhibition of aluminium alloy in 0.5M H2SO4 solution in the presence of zinc gluconate at 301 K was investigated using weight loss and an electrochemical method. Surface analysis of the aluminium alloy sample was reviewed by a high resolution scanning electron microscope equipped with energy dispersive spectroscopy (HRSEM/ EDS). The readings were taken after 48 h for 28 days while the concentration of the inhibitor was varied from 0.5 to 2.0% g/v with an interval of 0.5. The result of the investigation shows that zinc gluconate has a good corrosion inhibition effect for aluminium alloy in 0.5 molar sulphuric acid solution and its efficiency attains more than 67% at 1.5% g/v concentration of zinc gluconate at 301 K. The potentiodynamic polarization data showed that zinc gluconate acts as a mixed type corrosion inhibitor. The adsorption of zinc gluconate on aluminium alloy has been found to obey Freundlich adsorption isotherm at all the concentration of zinc gluconate studied. The results obtained from different methods are in good agreement.
Źródło:
Polish Journal of Chemical Technology; 2013, 15, 4; 60-64
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structural, morphological and photoluminescent properties of Nd-coated silicon nanostructures
Autorzy:
Mefoued, Amine
Mahmoudi, Bedra
Benrekaa, Nasser
Tiour, Faiza
Menari, Hamid
Naitbouda, Abdelyamine
Manseri, Amar
Brik, Afaf
Mezghiche, Salah
Debbab, Moustafa
Powiązania:
https://bibliotekanauki.pl/articles/2204154.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Elektryków Polskich
Tematy:
silicon nanostructures
silicon nitride
neodymium
SEM/EDS
SIMS
Raman spectroscopy
photoluminescence
Opis:
The structural, morphological and photoluminescent properties of thermally evaporated neodymium oxide (Nd₂O₃) thin films deposited onto nanostructured silicon (Si-ns) are reported. Si-ns embedded in silicon nitride (SiN) thin films are prepared by plasma-enhanced chemical vapour deposition (PECVD). SiN and Nd₂O₃ thin films uniformity and Si-ns formation are confirmed by atomic force microscopy (AFM) and scanning electron microscopy (SEM). The presence of neodymium (Nd), silicon (Si), oxygen (O), and phosphorus (P) is investigated by energy-dispersive spectroscopy (EDS) and secondary ion mass spectrometry (SIMS). Post-annealing SIMS profile indicates an improvement of the homogeneity of activated P distribution in Si bulk. The X-ray diffraction (XRD) combined with Raman spectroscopy and Fourier-transform infrared spectroscopy (FTIR) have been employed to determine amorphous silicon (a-Si), crystalline silicon (c-Si), Nd₂O₃ and SiN phases present in the Nd₂O₃-SiN bilayers with their corresponding chemical bonds. After annealing, a Raman shift toward lower wavenumbers is recorded for the Si peak. XPS data reveal the formation of Nd₂O₃ thin films with Nd-O bonding incorporating trivalent Nd ions (Nd3+). Strong room-temperature photoluminescence is recorded in the visible light range from the Si-ns. Nd-related photoluminescent emission in the near infrared (NIR) range is observed at wavelengths of 1025-1031 nm and 1083 nm, and hence is expected to improve light harvesting of Si-based photovoltaic devices.
Źródło:
Opto-Electronics Review; 2023, 31, 1; art. no. e145096
1230-3402
Pojawia się w:
Opto-Electronics Review
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of lithium nitrate on the reaction between opal aggregate and sodium and potassium hydroxides in concrete over a long period of time
Autorzy:
Zapała-Sławeta, J.
Owsiak, Z.
Powiązania:
https://bibliotekanauki.pl/articles/200662.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
alkali-silica reaction
lithium nitrate
ettringite formation
expansion
SEM/EDS
azotan litu
ekspansja
Opis:
Alkali-silica reaction (ASR) is a reaction between amorphous or poorly crystallized siliceous phase, present in aggregates, and sodium and potassium hydroxides in the pore solution of concrete. Chemical admixtures such as lithium compounds are known to have high potential of inhibiting ASR. The aim of this study was to determine the effect of lithium nitrate on ASR in mortars containing high reactive opal aggregate over a long period of time. Mortar bar expansion tests were performed and microstructures of mortar bars were observed by scanning electron microscopy coupled with an energy dispersive X-ray microanalyser. Results from this study showed that effectiveness of lithium nitrate in mitigating ASR was limited over a long period of time. A larger amount of ASR gel which was formed in the presence of lithium nitrate indicated that the deterioration processes intensify within longer periods of time, which so far has not been observed in literature. Microscopic observation confirmed the presence of alkali-silica gel and delayed ettringite in mortars with lithium nitrate.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2017, 65, 6; 773-778
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Tribological Properties of the TI6AL4V Alloy with Nitrogen Ion Implantation
Ocena właściwości tribologicznych stopu tytanu TI6AL4V implantowanego jonami azotu
Autorzy:
Piotrowska, Katarzyna
Baranowicz, Paweł
Wysokińska-Miszczuk, Joanna
Madej, Monika
Skóra, Monika
Powiązania:
https://bibliotekanauki.pl/articles/190823.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
titanium alloys
ion implantation
friction
wear
SEM/EDS
contact angle
stopy tytanu
implantacja jonowa
tarcie
zużycie
kąt zwilżania
Opis:
The article presents the analysis of the influence of ion implantation on the properties of titanium alloy used in biotribological systems. The object of the study was the titanium alloy Ti6Al4V implanted with nitrogen ions. Tribological model tests were carried out in combination with a sphere with Al2O3 – a Ti6Al4V alloy disc implanted with N+ ions. Experimental friction tests were carried out on pin-on-disc testers in conditions of technically dry conditions and in conditions of lubrication with the Ringer’s solution. The tests on the TRB tester were carried out in a swinging motion, while on the T-01 tester in a sliding movement. Friction coefficient and wear were determined for all tests. Surface morphology testing and chemical composition analyses were performed using the Jeol JSM-7100F scanning electron microscope, equipped with an EDS microanalyzer. Surface geometry measurements prior to and after tribological tests were performed on a Taylor Hobson’s Talysurf CCI contactless optical profilometer. The optical tensiometer was used to determine the contact angles with demineralized water and Ringer’s solution. The tribological tests of the titanium alloy Ti6Al4V lead to the conclusion that implantation of N+ ions results in better tribological properties of the alloy. The best tribological characteristics were obtained for a titanium alloy implanted with nitrogen ions under technically dry friction conditions. The influence of the tribological system on Ringer’s fluid influenced the reduction of coefficients of friction in the oscillating movement (Tribometer TRB) and sliding motion (Tester T-01M). In the case of a oscillating movement, higher wear of the tested friction pair was observed under friction conditions with the Ringer solution lubrication.
W artykule przedstawiono analizę wpływu implantacji jonowej na właściwości stopu tytanu stosowanego w systemach biotribologicznych. Przedmiotem badań był stop tytanu Ti6Al4V implantowany jonami azotu N+. Tribologiczne badania modelowe przeprowadzono w skojarzeniu kula z Al2O3–tarcza ze stopu Ti6Al4V implantowana jonami azotu. Eksperymentalne testy tarciowe zrealizowano na testerach typu pin-on-disc w warunkach tarcia technicznie suchego oraz tarcia ze smarowaniem roztworem Ringera. Badania na testerze TRB przeprowadzono w ruchu wahadłowym, natomiast na testerze T-01 w ruchu ślizgowym. Dla wszystkich testów określono współczynnik tarcia oraz zużycie. Przy użyciu skaningowej mikroskopii elektronowej SEM wraz z analizą składu chemicznego EDS oraz profilometrii interferometrycznej obserwowano morfologię oraz topografię powierzchni badanych próbek przed i po testach tribologicznych. Tensjometr optyczny posłużył do wyznaczenia kątów zwilżania wodą demineralizowaną oraz roztworem Ringera. Uzyskane wyniki badań pozwoliły na stwierdzenie, że zastosowanie implantacji jonowej istotnie poprawia właściwości tribologiczne stopu tytanu zarówno w warunkach tarcia technicznie suchego, jak i w warunkach smarowania roztworem Ringera. Najlepsze charakterystyki tribologiczne uzyskano dla stopu tytanu implantowanego jonami azotu w warunkach tarcia technicznie suchego. Oddziaływanie systemu tribologicznego z płynem Ringera wpłynęło na zmniejszenie współczynników tarcia w ruchu wahadłowym (Tribometr TRB) i ślizgowym (Tester T-01M). W przypadku ruchu wahadłowego większe zużycie badanych par trących zaobserwowano w warunkach tarcia ze smarowaniem roztworem Ringera.
Źródło:
Tribologia; 2019, 283, 1; 37-47
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the surface geometry of the orthodontic archwire and their influence on the bacterial adhesion
Autorzy:
Ziębowicz, B.
Woźniak, A.
Ziębowicz, A.
Ziembińska-Buczyńska, A.
Powiązania:
https://bibliotekanauki.pl/articles/366963.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
archwires
b-Ti
AFM
atomic force microscope
SEM/EDS
confocal microscopy
pitting corrosion
łuk ortodontyczny
mikroskop sił atomowych
mikroskopia konfokalna
korozja wżerowa
Opis:
Purpose: The aim of this work is to characterize the surface geometry of the orthodontic archiwire and their influence of the pitting corrosion resistance and bacterial adhesion. Design/methodology/approach: In the paper, the results of the SEM/EDS analysis and microscopic observation of the samples surface and analysis of geometrical structure with the use Atomic Force Microscope (AFM) and Confocal Microscopy were presented as well as the pitting corrosion test and surface roughness and microhardness measurements were performed. Additionally the microbiological study after bacterial breeding with the use Scanning Electron Microscope was carried out. Findings: In the basis of the investigation, it can be concluded that the surface geometry of archwire has a significant impact on their pitting corrosion resistance in artificial saliva solution and on the bacterial adhesion. The obtained results show satisfactory properties and surface geometry of the tested orthodontic wires for use in the human oral environment. Research limitations/implications: In the future, it is planned to extend the research with physicochemical properties and the influence of oral hygiene products on the corrosive behaviour of the material. Limitations in the conducted tests refer to archwire design – a small diameter making measurements difficult. Practical implications: The oral environment is an extremely aggressive corrosive environment. The orthodontic elements should have very good corrosion resistance and biocompatibility. The focus should be on continuously improving orthodontic wires in terms of material quality and topography of its surface topography. Originality/value: The research is conducted in the field of biomedical engineering, which is part of material engineering and is used for the field of dentistry and microbiology.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2019, 93, 1-2; 32-40
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies