Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ramos, P." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Effect of microwave power on EPR spectra of thermally sterilized eucerinum anhydricum
Autorzy:
Ramos, P.
Pepliński, P.
Pilawa, B.
Powiązania:
https://bibliotekanauki.pl/articles/148715.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
EPR
microwave saturation
free radicals
eucerinum anhydricum
thermal sterilization
Opis:
Free radicals formed during thermal sterilization of eucerinum anhydricum – the pharmaceutical base were examined by an X-band (9.3 GHz) spectrometer. Eucerinum anhydricum was sterilized at different physical conditions according to the Polish Pharmacopeia norms. The samples were heated at temperatures: 160°C (120 min), 170°C (60 min), and 180°C (30 min). The aim of this study is to compare free radical concentration and effect of microwave power on EPR spectra of eucerinum anhydricum base thermally sterilized at different temperatures and periods of time. The effect of time storage on the free radicals in the heated samples was tested. Free radical concentrations in the sample stored 15 min strongly decreased with the increasing of sterilization temperature, probably as the result of recombination. Storage caused strong decrease of free radical concentrations in the samples, probably as the result of interactions with oxygen. It was observed to be independent of sterilization conditions from 2 days of storage and longer. Because of the lowest free radical concentration, for eucerinum anhydricum thermal sterilization at 180°C for 30 min is recommended. The sterilized samples should be stored at inert atmosphere without oxygen molecules. Fast spin-lattice relaxation processes existed in sterilized eucerinum anhydricum. The character of changes of amplitudes and linewidths of EPR lines with increasing of microwave power was the same for different storage times. The parameters of thermal sterilization and storage time influenced free radical concentration in eucerinum anhydricum, but magnetic spin-lattice interactions were unchanged. The usefulness of EPR spectroscopy in optimization of thermal sterilization process of eucerinum anhydricum was confirmed.
Źródło:
Nukleonika; 2015, 60, No. 3, part 1; 439-442
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of microwave power on EPR spectra of natural and synthetic dental biocompatible materials
Autorzy:
Adamczyk, J.
Ramos, P.
Pilawa, B.
Powiązania:
https://bibliotekanauki.pl/articles/147235.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
EPR
microwave saturation
paramagnetic centers
dental biocompatible materials
Opis:
Paramagnetic centers in the two exemplary synthetic and natural dental biocompatible materials applied in implantology were examined by the use of an X-band (9.3 GHz) electron paramagnetic resonance (EPR) spectroscopy. The EPR spectra were measured in the range of microwave power 2.2–70 mW. The aims of this work were to compare paramagnetic centers concentrations in different dental biocompatible materials and to determine the effect of microwave power on parameters of their EPR spectra. It is the very fi rst and innovatory examination of paramagnetic centers in these materials. It was pointed out that paramagnetic centers existed in both natural (~1018 spin/g) and synthetic (~1019 spin/g) dental biocompatible materials, but the lower free radical concentration characterized the natural sample. Continuous microwave saturation of EPR spectra indicated that faster spin-lattice relaxation processes existed in synthetic dental biocompatible materials than in natural material. Linewidths (ΔBpp) of the EPR spectra of the natural dental material slightly increased for the higher microwave powers. Such effect was not observed for the synthetic material. The broad EPR lines (ΔBpp): 2.4 mT, 3.9 mT, were measured for the natural and synthetic dental materials, respectively. Probably strong dipolar interactions between paramagnetic centers in the studied samples may be responsible for their line broadening. EPR spectroscopy is the useful experimental method in the examination of paramagnetic centers in dental biocompatible materials.
Źródło:
Nukleonika; 2015, 60, No. 3, part 1; 449-453
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania FT-IR i EPR zmian struktury chemicznej ampicyliny podczas sterylizacji termicznej
FT-IR and EPR studies of changes of chemical structure of ampicyline during thermal sterilization
Autorzy:
Krztoń, A.
Liszka, B.
Ramos, P.
Pilawa, B.
Powiązania:
https://bibliotekanauki.pl/articles/284230.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
ampicylina
sterylizacja termiczna
FTIR
wolne rodniki
EPR
ampicyline
thermal sterilization
free radicals
Opis:
Zbadano zmiany struktury chemicznej oraz generowanie wolnych rodników w ampicylinie podczas sterylizacji w temperaturach 160 stopni C, 170 stopni C i 180 stopni C. Jako metody badawcze zastosowano spektroskopię FT-IR i EPR.. Wykazano, że sterylizacja w temperaturach od 160 stopni C do 180 stopni C powadzi do zmian struktury chemicznej ampicyliny oraz powoduje powstawanie dużej ilości wolnych rodników w próbce. Widma FT-IR uwidaczniają częściową degradację grupy karboksylowej w trakcie ogrzewania leku. Zależność kształtu widm EPR od mocy mikrofalowej wskazuje na złożony charakter układu centrów paramagnetycznych sterylizowanej ampicyliny.
Changes of chemical structure and formation of free radicals in ampicyline during sterilization at temperatures 160 degrees of C, 170 degrees of C, and 180 degrees of C were studied. FT-IR and EPR were applied as experimental methods. It was proved that sterilization at temperatures from 160 degrees of C to 180 degrees of C lead to changes of chemical structure of the ampicyline and causes formation of high amount of free radicals. FT-IR spectra show that carboxyl groups are partly evolved during heating of this drug. Dependence of lineshape of EPR spectra on microwave power indicates complex character of paramagnetic centers system of ampicyline.
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 154-157
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie właściwości wolnych rodników w streptomycynie sterylizowanej radiacyjnie i termicznie
Comparison of free radicals properties in radiosterilised and thermal sterilized streptomycin
Autorzy:
Wilczyński, S.
Ramos, P.
Pilawa, B.
Ptaszkiewicz, M.
Swakoń, J.
Olko, P.
Powiązania:
https://bibliotekanauki.pl/articles/283986.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
wolne rodniki
sterylizacja termiczna
sterylizacja radiacyjna
streptomycyna
EPR
free radicals
thermal sterilization
radiosterilization
streptomycin
Opis:
Sterylność substancji leczniczej jest niezwykle istot-na z punktu widzenia bezpieczeństwa farmakoterapii. Sterylizacja leków może powodować powstawanie wolnych rodników. Porównano właściwości wolnych rodników powstających pod wpływem promieniowania termicznego (180°C/30 minut) i promieniowania gamma (25kGy) w streptomycynie. Badania prze-prowadzono przy użyciu techniki elektronowego rezonansu paramagnetycznego EPR na pasmo X. Zarówno dla próbek sterylizowanych termicznie jak i radiacyjnie zarejestrowano szerokie linie EPR. Obydwie metody sterylizacji prowadzą do powstania wysokich koncentracji wolnych rodników (1016–1018 spin/g). Porównanie parametrów linii EPR dla sterylizacji termicznej i radiacyjnej wskazuje na podobne właściwości wolnych rodników w sterylizowanej próbce – niesparowane elektrony zlokalizowane na atomie tlenu. Więcej wolnych rodników, w przypadku zastosowanych parametrów sterylizacji, powstaje w próbkach sterylizowanych radiacyjnie.
Sterility of medical substances plays significant role from the point of view of pharmacotherapy safety. Drugs sterilization can cause free radicals forming. It was compared free radicals properties forming in streptomycin under the influence thermal radiation (180°C/30 minutes) and gamma radiation (25kGy). Presented studies were performed by use of X band electron paramagnetic spectrometer. Both for thermal sterilized samples as well as for radiosterilized broad EPR lines were recorded. Both methods of sterilization lead to forming of high concentrations of free radicals (1016–1018spin/g). Comparing of EPR lines parameters for thermal sterilization and radiosterilization point at similar free radicals properties in the studied samples – unpaired electrons located on oxygen atoms. More free radicals, in case of used sterilization parameters, create in radiosterilized samples.
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 171-173
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości paramagnetyczne biomateriałów
Paramagnetic properties of biomaterials
Autorzy:
Pilawa, B.
Adamczyk, J.
Zdybel, M.
Wilczyński, S.
Ramos, P.
Czyżyk, D.
Kościelniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/283897.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
biomateriały
paramagnetyzm
centra paramagnetyczne
wolne rodniki
EPR
biomaterials
paramagnetism
paramagnetic centers
free radicals
Opis:
Paramagnetyczne biomateriały mogą być wysoce reaktywne oraz mogą ulegać destrukcji w wyniku reakcji wolnorodnikowych. W pracy przedstawiono znane z literatury naukowej badania właściwości paramagnetycznych biomateriałów z zastosowaniem spektroskopii elektronowego rezonansu paramagnetycznego (EPR). Wskazano także paramagnetyczne biomateriały, które nie były dotąd analizowane metodą EPR.
Paramagnetic biomaterials may be very reactive and they may be destroyed by free radical reactions. In this work the known from scientific publications electron paramagnetic resonance (EPR) studies of paramagnetic properties of biomaterials are presented. Unexamined by EPR paramagnetic biomaterials were also described.
Źródło:
Engineering of Biomaterials; 2009, 12, no. 89-91; 166-168
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies