Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "laser interferometer" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Impact of the technological conditions of plane surface machining on a triangular milling cutter on the residual hysteresis of the movement axis of the machine
Autorzy:
Stejskal, T.
Kráľ, J.
Rudy, V.
Melko, J.
Rjabušin, A.
Pavliková, L.
Powiązania:
https://bibliotekanauki.pl/articles/957896.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
machine tools
laser interferometer
hysteresis
Opis:
The paper deals with the possibilities of measuring the residual displacement or hysteresis on the lateral direction of the movement forces caused by the cutting forces of the machining. A special adjustment of laser interferometry assemblies was used for measurement. The measurement results indicate that the positioning accuracy in addition to the cutting forces also influences the position of the displaced moving substances and the temperature. The complex effect of these parameters is greatly dependent on the design of the machine.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 3; 240-245
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elimination of thermal drift in measuring the positioning accuracy of a three axis milling machine
Autorzy:
Stejskal, T.
Dovica, M.
Demeč, P.
Svetlík, J.
Rajťuková, V.
Powiązania:
https://bibliotekanauki.pl/articles/102352.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
accuracy
laser interferometer
positioning
machine tool
Opis:
The aim of this paper is to draw attention to more reliable verification method of positioning accuracy. The improvement lies in mathematical elimination of thermal impact during the measurement process. This thermal impact, always present during the motion of movable parts, is of a special systemic character. It increases the indefiniteness of measurement of the classic measurement method. This measurement uncertainty can be reduced by implementing the procedure introduced in this paper. The reduction can be achieved by separating the temperature impact from other sources of inaccuracy. Such separation is a very new solution. The methodology relies on mathematical processing and does not depend on the manner of accuracy measurement. The evaluation method also yields diagnostic information on the machine’s condition. The experiments were performed with the use of laser interferometer.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 159-167
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Angular positioning accuracy of rotary table and repeatability of five-axis machining centre dmu 65 monoblock
Autorzy:
Józwik, J.
Czwarnowski, M
Powiązania:
https://bibliotekanauki.pl/articles/103390.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
positioning
diagnostics
accuracy
CNC machine tool
laser interferometer
Opis:
The study aims to evaluate angular positioning accuracy and repeatability of DMU 65 monoBLOCK numerically controlled machine tool. The measurements were carried out with XL-80 Laser Interferometer with XR20-W attachment. The measurements were conducted according to the standard PN-ISO230-2. Test methodology and measurement results analysis are presented in a form of figures and tables. The final part presents conclusions from the analysis.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 28; 89-95
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja przesuwu karetki pomiarowej na stanowisku komparatora interferencyjnego do wzorcowania wzorców kreskowych
Development of air-bearing stage for line scale interferometric comparator
Autorzy:
Sosinowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/155396.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorce kreskowe
pomiary interferencyjne
stolik powietrzny
line scales
laser interferometer
air-bearing stage
Opis:
W referacie przedstawiono budowę oraz zasadę pomiaru wykorzystywaną na komparatorze interferencyjnym do wzorcowania wzorców kreskowych oraz opisano modernizację posiadanego przez Laboratorium Długości Zakładu Długości i Kąta GUM stanowiska pomiarowego, która polegała na zaprojektowaniu i wykonaniu stolika powietrznego, zbudowanego z prowadnicy granitowej i łożysk powietrznych, napędzanego przez silnik krokowy. W artykule przedstawiono zalety zastosowanego rozwiązania, wyniki pomiarów wraz ze sposobem wyznaczenia błędów geometrycznych stolika powietrznego i ich wpływ na niepewność pomiaru wzorców kreskowych.
The line scales are important physical standards of length used for accurate positioning or measurement in one, two or three dimensions [1]. It plays an important role in ensuring the traceability of measurements made with instruments such as microscopes, measuring projectors, length measuring machines, measuring magnifiers or, more commonly used, vision systems for length measurements. The growing need for calibration of this type instruments and the need to ensure the accurate calibration of the line scales require maintaining and continuous upgrading of the line scale interferometric comparator. The calibration accuracy largely depends on the accuracy of the measuring carriage motion of the attached line scale in both the visual system and the laser interferometer, as the reference standard. The accuracy of measurement is affected by a number of factors, which causes that the measured value differs from the actual one. These factors are inaccurate execution and transmission wear, such as screw – nut system or the guide wear. By replacing the previously used mechanical movement with the precision air-bearing stage, a much smaller uncertainty of calibration of the line scales was achieved. The paper presents the modernized by the Length Laboratory of the Department of Length and Angle of GUM measuring station which allows the calibrations of the line scales of the nominal lengths from 1 mm to 500 mm, and describes the impact of angular errors of the measuring carriage on the measurement results.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 5, 5; 452-455
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wzrokowego ustalania środka kreski na niepewność wyników wzorcowania wzorców kreskowych na komparatorze interferencyjnym w GUM
The impact of visual assessment of the line centre on the uncertainty of measurements of line scales on the interferometric comparator in GUM
Autorzy:
Sosinowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/156605.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wzorce kreskowe
pomiary interferencyjne
system wizyjny
środek kreski
line scales
laser interferometer
vision system
line center
Opis:
W referacie przedstawiono stosowany w Laboratorium Długości Zakładu Długości i Kąta GUM sposób wzorcowania wzorców kreskowych na komparatorze interferencyjnym. Przedstawiono budowę zmodernizowanego stanowiska pomiarowego z przesuwnym stolikiem łożyskowanym na poduszkach powietrznych. W artykule zaprezentowano zalety i wady stosowanego sposobu określenia środka kreski oraz wynikające z tego ograniczenia pełnej automatyzacji stanowiska pomiarowego. Ponadto przedstawiono przykładowe wyniki pomiarów odchylenia długości zmierzonej od długości nominalnej podczas symetrycznego ustawiania kreski metodą wzrokową i ich udział w budżecie niepewności wzorcowania wzorców kreskowych.
In the paper a method for calibration of line scales on the interferometric comparator, used in the Length Laboratory of the Length and Angle Division of Central Office of Measures, is described. The construction of the modernized set up with air bearing stage is presented. This measuring station allows the calibrations of glass or metal line scales with nominal lengths up to 500 mm with the expanded uncertainty equal to [wzór], where L is the nominal length of the line scale, expressed in mm. The paper focuses on the way of line center detection using a CCD camera with an optical microscope system. The camera captures a magnified image of the line scale and then forward it to a computer via the USB port, so that the image is displayed on the screen. The position of the line center is determined by visual assessment of the line settings between two parallel lines. In the next part the advantages and disadvantages of the method used to determine the center line and the consequent restriction of full automation of the measuring station are presented. Some results of deviation of the measured length from the nominal length of the line scale symmetrical setting using the visual method are shown and contribution of the line center detection in the uncertainty budget of line scale calibration is presented. An overview of numerical algorithms used for determining the line center, thereby facilitating the process of measuring and improving its accuracy and repeatability is presented. Development of a new method using digital image analysis of line scale would eliminate the subjective role of the observer and thus reduce the measurement uncertainty associated with line center detection and repeatability of measurement results at least three times. In addition, such a solution makes it possible to automate the process of calibration of the line scales.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 537-540
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kalibracja wzorców liniowych do systemu fotogrametrycznego DPA Pro firmy AICON 3D Systems
Calibration of measurement standards for a DPA Pro photogrammetric system produced by AICON 3D Systems
Autorzy:
Frukacz, M.
Szczutko, T.
Powiązania:
https://bibliotekanauki.pl/articles/155524.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kalibracja
współczynnik rozszerzalności termicznej
interferometr laserowy
wzorzec pomiarowy
calibration
coefficient of thermal expansion
laser interferometer
measure standard
Opis:
W artykule zaprezentowano unikalną metodologię i wyniki wyznaczenia współczynnika rozszerzalności termicznej oraz kalibracji pary wzorców liniowych do sytemu fotogrametrycznego DPA Pro firmy AICON 3D Systems GmbH o długości 1,34 m. Stosowne badania przeprowadzono w Geodezyjnym Laboratorium Metrologicznym Wydziału Geodezji Górniczej i Inżynierii Środowiska AGH w Krakowie na zlecenie firmy MAN Bus Sp. z o.o., Oddział w Starachowicach.
The paper presents a unique methodology and results of determining the coefficient of thermal expansion and calibration of a pair of measurement standards of a DPA Pro photogrammetric system (Fig. 1) produced by AICON 3D Systems. The tests were carried out in the Geodetic Metrology Laboratory at Department of Mining Surveying and Environmental Engineering, AGH University of Science and Technology in Krakow, on behalf of MAN Bus, Branch Starachowice. Determination of the coefficient of thermal expansion was performed in a specially adapted thermal chamber (Fig. 2). The temperatures obtained in the thermal chamber during measurements of changes of the length caused by thermal factor ranged from 7 °C to 37 °C, at the average temperature of 22 °C (Fig. 3). The resulting thermal expansion coefficient was 0.31 μm/m/°C with the measurement uncertainty at 95% confidence level (2 sigma) of ± 0.06 μm/m/°C. Calibration of a pair measurement standards was made in a vertical (Fig. 5) and horizontal (Fig. 6) position twice, independently. As a master of lenght there was used the Hewlett-Packard HP 5529 laser interferometer. A two-axis measurement system of a vertical comparator allowed simultaneous measurement of microscope inclination (Fig. 4). Length of the measurement standards in the horizontal and vertical positions differs by about 8 μm, because the pattern in the horizontal position is shorter due to sagging under its own weight (Table 1). The measurement uncertainty of the DPA Pro standard length at the 95% confidence level was ± 3.9 μm.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 6, 6; 511-513
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Interferometr laserowy GBI300 do pomiarów materialnych wzorców długości - płytek wzorcowych
GBI300 laser interferometer for measuring of material standards of length - gauge blocks
Autorzy:
Szumski, R.
Powiązania:
https://bibliotekanauki.pl/articles/151697.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
płytki wzorcowe
interferometr laserowy GBI300
metoda interferencyjna
niepewność
walidacja
gauge blocks
laser interferometer GBI300
interferometry
uncertainty
validation
Opis:
Laboratorium Długości Zakładu Długości i Kąta GUM posiada najdokładniejszy w kraju, automatyczny interferometr laserowy do wzorcowania płytek wzorcowych o zakresie pomiarowym 305 mm. Interferometr GBI300 służy do wzorcowania płytek wzorcowych o przekroju prostokątnym, kwadratowym i okrągłym, służących następnie jako wzorce odniesienia przy pomiarach metodą porównawczą. Umożliwia on wyznaczenie takich parametrów płytek wzorcowych, jak odchylenie długości środkowej od długości nominalnej, zmienność długości oraz odchylenie od płaskości powierzchni pomiarowych. GBI300 jest zbudowany na bazie klasycznego interferometru "Twymana-Greena" z wykorzystaniem wysokiej jakości laserów stabilizowanych częstotliwościowo i oprzyrządowania sterowanego komputerowo. Układ pomiarowy działa w oparciu o metodę kroku fazowego (ang. phase stepping) wykorzystując techniki numerycznego przetwarzania obrazu do analizowania interferogramów otrzymanych z kamery CCD. źródem wzorcowych długości fal światła są dwa stabilizowane częstotliwościowo lasery helowo neonowe o długościach fal promieniowania: 633 nm (czerwony) i 543 nm (zielony). Dzięki zastosowaniu napędu do stolika pomiarowego możliwe jest wykonanie pomiarów do dwunastu płytek wzorcowych w krótkim okresie czasu, co znacznie zwiększa wydajność i pozwala na wykonanie większej ilości pomiarów każdej płytki. Stanowisko pomiarowe umieszczone jest w klimatyzowanym pomieszczeniu, zapewniającym stabilizację temperatury wewnątrz komory w zakresie (19,9 ÷ 20,1) °C. Komora pomiarowa umieszczona jest na stole z układem wibroizolacyjnym i połączona z jednostką sterująco-pomiarową, wyposażoną w urządzenia i komputer, sterujące pracą całego stanowiska oraz przyrządy pomiarowe do monitorowania warunków środowiskowych. Walidacja stanowiska pomiarowego i szacowanie niepewności pomiaru przeprowadzone zostały na podstawie badań przeprowadzonych w laboratorium oraz przy wykorzystaniu płytek wzorcowych posiadających świadectwo wzorcowania z National Physical Laboratory - Anglia.
Length Laboratory of Length and Angle Division of GUM uses the most accurate in Poland automatic laser interferometer for calibration of gauge blocks, with measurement range of 305 mm. The GBI300 interferometer can be used for calibration of both rectangular or square (Hoke) gauge blocks and round (British) length bars. The GBI300 allows to calculate of central deviation, flatness and variation in length of measured gauge blocks. The Automatic Gauge Block Interferometer combines a conventional Twyman-Green Interferometer with high quality frequency stabilised lasers and computer interfaced instrumentation. The combination of phase-stepping method, image processing and computing techniques for analysis of the interferogram makes the instrument less dependent on operator skills. Two frequency-stabilized He-Ne lasers provide the light sources for the interferometry (633 nm and 543 nm). During the measurement up to twelve gauges can be wrung to a platen that has servo motor rotation control. It allows to measure gauge blocks faster and more accurate. The interferometer is placed in air conditioned laboratory with temperature change in interferometer chamber in range (19,9 ÷ 20,1) °C. The measuring chamber is placed on the granite table with vibroisolation system. The control cabinet houses the control equipment and instrumentation for measuring ambient conditions. The calibration method validation was performed by comparing measurement results with results from calibration certificate issued by National Physical Laboratory in United Kingdom. The uncertainty was evaluated on the basis of tests and measurements carried out in the laboratory.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 58-60
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies