Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Air" wg kryterium: Temat


Tytuł:
The measuring position designed to determine the metrological properties of air gauges
Autorzy:
Jakubowicz, M.
Derezynski, J.
Powiązania:
https://bibliotekanauki.pl/articles/102919.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
air gauges
static characteristics
metrology
Opis:
This article describes the measurement system designed in order to determine the metrological properties of air gauges. The said scientific study makes it possible to determine the static pk = f(s) and flow qv = f(s) characteristics. It consists of three modules: a mechanical module, a control and register data module and a special software module. Apart from the possibility of determining the static and flow characteristics, the presented study makes it possible to measure the temperature in the duct that supplies the compressed air to the transducer as well as in the measuring chamber. The above-mentioned measurement system makes it possible to determine the pressure applied on the surface measured by an air stream coming from the nozzle. Apart from a detailed description of a test station and the software, the article also contains sample results of tests performed on air gauges.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 198-205
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilny system monitoringu jakości powietrza
Mobile Monitoring System for Air Quality Control
Autorzy:
Katulski, R.
Namieśnik, J.
Sadowski, J.
Stefański, J.
Wardencki, W.
Szymańska, K.
Powiązania:
https://bibliotekanauki.pl/articles/153758.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
systemy monitoringu
monitoring powietrza
kontrola jakości powietrza
monitoring systems
air monitoring
air quality control
Opis:
Zaprezentowano mobilny system monitoringu, który umożliwia kontrolę zanieczyszczeń powietrza atmosferycznego wzdłuż ciągów komunikacyjnych. W opracowanym systemie stacja monitorująca charakteryzuje się stosunkowo niewielkimi rozmiarami i zawiera układ elektroniczny autorskiego rozwiązania do pomiaru, zapisu i transmisji drogą radiową na serwer www pomierzonych stężeń związków chemicznych. Opracowane rozwiązanie jest stosunkowo tanie w budowie i eksploatacji, gdyż należy do tzw. urządzeń bezobsługowych. Przedstawiono przykładowe wyniki z przeprowadzonych testów funkcjonalnych w warunkach rzeczywistych.
The paper presents a mobile monitoring system for main air pollutants in the cities. The novelty of the proposed system is connected with the fact that it can be used to monitor emissions from urban traffic along roads and those areas, where traditional monitoring stations cannot be placed. In the proposed system, a mobile monitoring station may be attached to private cars, buses, trucks etc. Stations in this system are small, have portable structures and contain an electronic instrument used to measure, record and transmit the concentration of various pollutants to the Website. The proposed station should be cheap, reliable, not requiring frequent routine maintenance procedures like calibration and filter changes. The test results in the real conditions are presented.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 3, 3; 126-129
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Thermography to Locate Air Leakages through the envelope of a Building in the summer season
Autorzy:
Stachniewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/114210.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
termography
envelope air-leakness
airtightness test
Opis:
The article presents how to use thermography to locate leakages through the air envelope of three selected single-family houses. Identification of air leakage was possible using differential analysis of thermal images recorded during a pressure test of the buildings as thermovision sequences. This enabled the detection of leakages through envelopes of the buildings at small summer internal and external temperature differences from 2 to 5(C.
Źródło:
Measurement Automation Monitoring; 2015, 61, 6; 261-264
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mobilny monitoring zanieczyszczeń powietrza w aglomeracjach miejskich - koncepcja systemu
A concept of a mobile measurement system for air pollution monitoring in urban area
Autorzy:
Dziadak, B.
Makowski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/154248.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mobilne systemy pomiarowe
zanieczyszczenia atmosfery
monitorowanie zanieczyszczenia atmosfery
mobile measurement systems
air pollutants
air quality monitoring
Opis:
W artykule przedstawiony jest projekt mobilnego systemu pomiarowego funkcjonującego w ramach koncepcji tak zwanego „inteligentnego miasta”. Jednym z kluczowych czynników kształtujących jakość życia na obszarze metropolii jest skład i parametry powietrza. Wiadomo, że w wielu polskich aglomeracjach, dopuszczalne stężenia zanieczyszczeń powietrza są przekraczane. Powszechnie prowadzi to do licznych i poważnych problemów zdrowotnych wśród mieszkańców. Mobilny system rozproszony do pomiarów stanu powietrza byłby narzędziem do analizy źródeł tych problemów i mógłby pełnić rolę informacyjna zarówno dla lokalnej społeczności jak i dla władz miasta.
A project of a mobile measurement system functioning as a part of a "smart city" is presented in this paper. One of the key factors shaping the quality of life in the urban area is composition and parameters of the air. It is widely known than in many Polish cities allowable concentrations of air pollutants are exceeded. Generally, it leads to numerous and serious health problems in the population [1]. In the concept presented, measurements of environmental factors are based on mobile, multisensor measurement devices. The measurements are simultaneously taken in many points. The mobility of measurement devices can be achieved by attaching them to public transportation or similar vehicles such as cabs or public (rented) bicycles (Fig. 2). The data processing should be done with IT back-end. Based on a data-centric approach it should provide features such as: gathering, integration, processing, modeling, visualization and providing insight to information about the state and changes of the air quality in the city. IT and a computational system by integrating data from mobile sources are a tool in decision making process performed by the authorities responsible for city development and current functioning. Thanks to deployment of this solution, strategic decisions could include actions aimed at improving the quality of life of city residents.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 9, 9; 682-685
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigations of the vibration effect in a measurement system for air flow phenomena in large pipelines
Autorzy:
Kabaciński, M.
Pawliczek, R.
Powiązania:
https://bibliotekanauki.pl/articles/114391.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
air flow
vibration
strain gauge
virtual instrument
Opis:
A measuring system for investigation of the air flow phenomena in large tubes is presented in this paper. The main goal is to measure and analyze the vibration effect of a sensing element used for air velocity and air stream measurement. It was observed that some vibrations occurred and involved damage effect in the flow sensor. The measuring system is based on the strain gauge technology with the use of a virtual instrument in the laboratory equipment. The presented system allows measuring, identifying and analyzing vibrations of the sensor in time and frequency domains. It was created as a virtual instrument, very easy to implement into the entire control system of the stand. It was found that the load of the sensing element was asymmetric and the mean load value, compared to variable loads, arose from disturbances of the air flow around the sensor. It was observed for the examined velocities of the air stream in the range up to 35 m/s.
Źródło:
Measurement Automation Monitoring; 2016, 62, 3; 96-99
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
EGNOS - use of GPS system for approach procedures
Autorzy:
Wajszczak, E
Galas, D
Powiązania:
https://bibliotekanauki.pl/articles/102307.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
GPS system
aviation
air navigation
approach procedure
Opis:
Since GPS system became available for common use, a it has been applied in many areas, including aviation. The development of portable GPS receivers provided immeasurable aid in air navigation. The paper presents EGNOS system that ensures the possibility of using GPS system for approach procedure. The article addresses the following issues: the history of creation and development of GPS, principle of system operation, accuracy in relation for GPS system, comparison with conventional radio navigation ILS system and potential benefits from implementing EGNOS.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 17; 62-65
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie strat ciśnienia w instalacji sprężonego powietrza
Determination of pressure losses in a compressed air system
Autorzy:
Perz, K.
Rewolińska, A.
Grześkowiak, K.
Powiązania:
https://bibliotekanauki.pl/articles/2072001.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
sprężone powietrze
straty ciśnienia
instalacja sprężonego powietrza
straty energii
compressed air
pressure losses
compressed air system
energy losses
Opis:
Celem pracy było określenie wartości strat ciśnienia w instalacji sprężonego powietrza. Oprócz charakterystyki sprężonego powietrza podano także informacje dotyczące sieci pneumatycznej - jej budowy, elementów składowych, a także strat ciśnienia, które powstają w takich instalacjach. Przedstawiono autorski program FINCH, który pozwala na szybkie i kompleksowe obliczanie strat ciśnienia w instalacji sprężonego powietrza.
The aim of this study was to determine the pressure losses in a compressed air system. In addition to the characteristics of compressed air, information concerning the pneumatic network, its structure, components, and pressure losses that arise in such installations are also given. The paper presents authors' own program FINCH, which allows the quick and comprehensive calculation of pressure losses in compressed air systems.
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 2; 101--102
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania hydrodynamiki w kolumnie air-lift z zewnętrzną cyrkulacją cieczy
Experimental studies of hydrodynamics in an external-loop air-lift column
Autorzy:
Karcz, J.
Bitenc, M.
Kacperski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/2070975.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kolumna air-lift
kolumna z zewnętrzną cyrkulacją cieczy
hydrodynamika
roztwór sacharozy
external-loop air-lift column
hydrodynamics
sucrose solutions
Opis:
Badania przeprowadzone w kolumnie air-lift z zewnętrzną cyrkulacją cieczy miały na celu określenie wpływu stężenia sacharozy w roztworach wodnych na: udział gazu zatrzymanego w cieczy, prędkości płynu w strefach opadania i wznoszenia, a także na czas cyrkulacji. Wyniki pomiarów opracowano matematycznie.
The aim of studies carried out in an external-loop air-lift column was to determine an effect of sucrose concentration in aqueous solutions on gas hold-up, liquid velocity in the downcomer and riser, and circulation time of liquid. The experimental results were approximated mathematically.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 1; 57-58
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of a Primary Air Distribution in a Plenum Chamber of the 700 MWth Circulating Fluidized Bed Boiler
Autorzy:
Mirek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2201878.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
windbox
circulating fluidized bed boiler
fluidization
primary air
Opis:
The windbox is a compressed air chamber installed directly beneath the fluidized bed boiler grid and is designed to evenly distribute air across the entire cross-section of the air distributor. Due to the large volume of the plenum chambers, it is very difficult to experimentally determine the flow conditions within them. Therefore, the analysis of airflow in these devices is usually performed using computational fluid dynamics tools. The article presents the results of modeling primary air distribution in the plenum chamber of the 700 MWth circulating fluidized bed boiler operating in PGE GiEK S.A. Turów Power Plant Division. Based on the results of calculations performed using the ANSYS Fluent software, the basic problems of the design windbox geometry were identified and a method for improving the uniformity of the gas flow under the grid was proposed. As can be seen from the results obtained, the design geometry of the windbox does not provide the required uniformity of air distribution under the grid.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 5; 86--99
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja przepływu pęcherzyków powietrza za pomocą tomografii optycznej : przegląd metod
Identification of air bubble flow with optical tomography : a review of methods
Autorzy:
Rząsa, M. R.
Powiązania:
https://bibliotekanauki.pl/articles/2070960.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pęcherzyki powietrza
tomografia optyczna
air bubbles
optical tomography
Opis:
W pracy charakteryzowano trzy metody wyznaczania parametrów pęcherzyków gazu poruszających się w cieczy. Metody pomiarowe oparte są na tomografii optycznej. W zwięzły sposób omówiono zasadę działania, a następnie zwrócono na wady i zalety tych rozwiązań. Podano przykładowe wyniki badań oraz odniesiono się do zakresu stosowalności omówionych metod. W podsumowaniu zwrócono uwagę na istotne elementy będące pomocne przy wyborze optymalnej metody pomiarowej w zastosowaniu do badanego procesu.
The paper presents three methods for the determination of parameters of gas bubbles moving in liquid. The measuring methods are based on optical tomography. Advantages and disadvantages of technical solutions are described. Exemplary test results are given and a range of their applicability is defined. Finally, a special attention was taken to select a proper measurement method for the process tested.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 2; 107-108
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania ruchu powietrza i rozkładu stężenia nanocząstek podczas obróbki nanomateriałów
Application of modifying elements of turbulent air velocity field in studies of air distribution during processing of nanomaterials
Autorzy:
Jankowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/2072880.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
nanomaterials
local exhaust ventilation
air distribution
turbulence intensity
Opis:
Opisano opracowaną metodę badania ruchu powietrza i emisji pyłów na stanowiskach do obróbki nanomateriałów z użyciem termoanemometrii i znacznika SF6 . Przedstawiono wyniki badania rozkładów prędkości powietrza, stężenia pyłów oraz natężenia ich emisji ze źródeł w zależności od modelu modyfikującego turbulentne pole prędkości przepływu. Wyniki potwierdzają, że zastosowanie efektywnego współdziałania wentylacji ogólnej z miejscową wywiewną może powodować wzrost sprawności wychwytu nanoobiektów.
Application of thermoanemometry and tracer gas method (SF6) for testing the air distribution and dust emission at workplaces with machining of nanomaterials is described in the paper. An influence of the model modifying turbulent air velocity field on the air velocity distribution, dust concentration and emission mass flow rate from a pollutant source was investigated. The results confirm the possibility of effective employment of the cooperation of general and local exhaust ventilation leading to the increase of nanoobjects’ capture efficiency.
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 4; 253--254
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling Hydrocarbons Cold-Start Emission from Passenger Cars
Autorzy:
Laskowski, Piotr
Zasina, Damian
Zimakowska-Laskowska, Magdalena
Orliński, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2123276.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
air pollution
road transport
hydrocarbon emissions
cold start
Opis:
The aim of this paper is to present the results of mathematically modelling the influence of ambient temperature on hydrocarbons (HCs, comprised of methane and non-methane volatile organic compounds) in cold-start emissions from passenger cars (PCs) for different fuel types, vehicle segments including hybrid vehicles, and the Euro standard. In this article the simulations are performed using COPERT software, assuming ambient temperatures from 20◦C to +30◦C, with 5◦C intervals. The modelling results presented show that a change in ambient temperature has a significant effect on hydrocarbons in cold-start emissions. Furthermore, our results show that hydrocarbons emissions are sensitive to ambient temperature fluctuations, and dependent on fuel type, vehicle segment, and the Euro standard.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 3; 117--125
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ konstrukcji hybrydowego aparatu fluidyzacyjnego na jego charakterystykę hydrodynamiczną
Influence of hybrid lluidized-bed apparatus design on its hydrodynamic characteristics
Autorzy:
Boroń, D.
Bizon, K.
Powiązania:
https://bibliotekanauki.pl/articles/2073229.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
fluidyzacja
aparat
airlift
hydrodynamika
fluidization
air-lift device
hydrodynamics
Opis:
Omówiono sposób obliczania granicznych prędkości napowietrzania hybrydowych aparatów fluidyzacyjnych zależny od ich właściwości hydrodynamicznych. Wartości graniczne odnoszą się istnienia złoża fluidalnego i braku porywania pęcherzy gazowych do strefy opadania, a zależą od konstrukcji aparatu. Zaproponowano korzystną i prostą modyfikację aparatu z wewnętrzną cyrkulacją cieczy, która zwiększa intensywność napowietrzania, (lepsze natlenienie fazy ciekłej). Wykazano, że zastosowanie dodatkowej strefy odgazowania cieczy powoduje inny sposób obliczania górnej granicznej wartości prędkości gazu.
A method for calculation of critical aeration velocities for hybrid fluidized-bed apparatuses is discussed from the point of view of their hydrodynamic properties. The critical values refer to the fluidized bed and to the lack of entrainment of gas bubbles into a down-comer. They depend on the apparatus design. An advantageous and simple modification of the apparatus with the liquid internal circulation is proposed. The circulation increases the aeration intensity resulting in better oxygenation of liquid phase. It is demonstrated that the use of additional liquid degassing zone leads to a different method of calculation of upper critical gas velocity.
Źródło:
Inżynieria i Aparatura Chemiczna; 2016, 6; 220--222
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Concept of a Collection System for Gas Mixture from the Interior of Chimney Openings for Unmanned Flying Systems
Autorzy:
Klimczyk, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2123293.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
drone
UAV
air pollution
quality
environment
smog
probe
chimney
Opis:
Today, one of the most topical issues related to the quality and safety of life on Earth is the monitoring of air quality in terms of its pollution that is harmful to human health and life. The activities undertaken as part of monitoring carried out include, among others, analysis of the composition of exhaust fumes from emission sources, such as households and industrial entities, in terms of the presence therein of potentially hazardous substances, indirectly in order to detect violations of the applicable environmental standards. In order to conduct this type of analysis, unmanned aerial systems are commonly used, which allow sampling in the immediate vicinity of the emission source. However, the currently functioning solutions do not allow for exhaust fume sampling in a way that allows a mixture for testing to be taken directly from an emission source. This leads to questioning of the reliability of the conducted research, as it is uncertain in terms of the origin of the tested mixture, indicating that the test takes place not at the source of the emission, but in its surroundings. This study proposes a technical solution to sample exhaust fumes directly from the emission source - from the interior of chimney openings.
Źródło:
Advances in Science and Technology. Research Journal; 2021, 15, 3; 191--196
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie układu regulacji temperatury powietrza ogrzewanego w próżniowym kolektorze słonecznym
The study of a temperature control system for the air heated in a vacuum solar collector
Autorzy:
Śmierzchalski, R.
Mikulski, P.
Powiązania:
https://bibliotekanauki.pl/articles/151132.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
kolektor słoneczny powietrzny
metody regulacji temperatury
badanie układu sterowania
solar collector for heating air
air mixing
methods of control output temperature
controllers
Opis:
W pracy przedstawiono badanie układu regulacji temperatury powietrza na zmodernizowanym stanowisku badawczym kolektora słonecznego. Zaprezentowano metody regulacji temperatury wyjściowej kolektora oraz wyniki z przeprowadzonych pomiarów. Na ich podstawie stwierdzono, że najbardziej efektywną metodą regulacji temperatury wyjściowej jest mieszanie powietrza z wykorzystaniem regulatora proporcjonalno-całkującego (PI).
The paper describes the study of a control system of a solar collector in the modernized station. The technical parameters and details of this innovative solution of collectors as well as the test results are presented in [1]. The basis of the solution is to use a novel method of mixing air to the control output temperature. The medium (air) heated by the collector at the output is mixed with the ambient air passing into the fan. The output temperature varies depending on the rotational speeds of the fans. The first section of the paper concerns the possibility of replacing fossil fuels with renewable energy development. It presents some aspects of the use of solar collectors for heating the air in the construction market in Poland. The second section contains the description of the modernized station for testing the control system of the solar collector (Fig.2). In the third section there is the block diagram of the control system of the solar collector (Fig.3) with its description. The fourth section contains the results of studies of the control system of the solar collector. There are presented the graphs of the output and setpoint temperature for heating and cooling processes, with one and two fans (air mixing). For each controller there is determined the setpoint by the method of manual tuning (engineering). On the basis of the studies it was found that the most effective method of output temperature control was the method of air mixing with a PI controller. For the air heating process the operation of one fan at the maximum speed is sufficient.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 560-563
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies